Alberta Infrastructure and Transportation. Roadside Design Guide. November
2007. Appendix B. Reference Drawings. TABLE OF CONTENTS. Appendix. Title.
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B REFERENCE DRAWINGS
APPENDIX B
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
Appendix B Reference Drawings TABLE OF CONTENTS Appendix
Title
B1
Alberta Weak Post and Strong Post W‐Beam Guardrail
B2
High Tension Cable System
B3
Weak Post Box Beam Guardrail
B4
Precast F‐Shape and NJ Shape Concrete Barriers
B5
Thrie Beam Guardrail
B6
Cast‐in‐Place or Extruded F‐Shape Concrete Barrier and Single Slope Concrete Barrier
B7
Miscellaneous Drawings
APPENDIX B-i
TABLE OF CONTENTS
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS
APPENDIX B-ii
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B1 ALBERTA WEAK POST AND STRONG POST W‐BEAM GUARDRAIL
APPENDIX B1
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B1
Alberta Transportation Roadside Design Guide
March 2016
Appendix B1 Alberta Weak Post and Strong Post W-Beam Guardrail TABLE OF CONTENTS Dwg. No.
Drawing Title
Page Number
TEB 3.01
W-Beam Guardrail Hardware Wood Spacer Block and Post
H-APP-B1-1
TEB 3.02
W-Beam Guardrail Hardware Rail Detail
H-APP-B1-2
TEB 3.03
W- Beam Guardrail Hardware End Section – Wing
H-APP-B1-3
TEB 3.04
W-Beam Guardrail Hardware End Section – Buried
H-APP-B1-4
TEB 3.05
W-Beam Guardrail Hardware Terminal Connector
H-APP-B1-5
TEB 3.06
W-Beam Guardrail Hardware Bolt, Nut and Washer
H-APP-B1-6
TEB 3.09
Strong Post W-Beam Blocked-Out Guardrail
H-APP-B1-7
TEB 3.10 TEB 3.12 TEB 3.15a TEB 3.15b TEB 3.16a TEB 3.16b TEB 3.17a TEB 3.18a
W-Beam Guardrail Strong Post End Treatment Turn Down (1.9m Spacing – With blocks) W-Beam Guardrail Weak Post End Treatment Turn Down (3.8m Spacing – No Block) Typical W-Beam Strong Post or Modified Thrie Beam Guardrail Placement Roadside Hazards (Two and Four Lane Highways) Typical W-Beam Weak Post Guardrail Placement Roadside Hazards
H-APP-B1-8 H-APP-B1-9 H-APP-B1-10 H-APP-B1-11
Typical Strong Post W-Beam or Modified Thrie Beam Guardrail Placement at Bridge Approaches (Two-Lane Highway) Typical W-Beam Weak Post Guardrail Placement at Bridge Approaches (Two-Lane Highway) Typical Strong Post W-Beam or Modified Thrie Beam Guardrail Placement at Bridge Approaches (Four-Lane Divided Highway) Typical Strong Post W-Beam or Modified Thrie Beam Guardrail Placement for Median Hazards
H-APP-B1-12 H-APP-B1-13 H-APP-B1-15 H-APP-B1-17
TEB 3.53
W-Beam Guardrail Turn Down End Hardware
H-APP-B1-18
TEB3.56a
Weak Post W-Beam Installation on First Stage Paving Projects
H-APP-B1-19
RDG-B1.1 RDG-B1.2 RDG-B1.3
W-Beam Cable Anchor Terminal (Exit End Treatment for Divided Highways) Hardware Details for W-Beam and Thrie Beam Guardrail Cable Anchor Terminal Foundation Tube and Foundation Tube Soil Plate Details for W-Beam and Thrie Beam Cable Anchor Terminal
H-APP-B1-20 H-APP-B1-21 H-APP-B1-22
RDG-B1.4
W-Beam Strong Post TL-3 ET-Plus Extruder Energy Absorbing Terminal
H-APP-B1-23
RDG-B1.5
W-Beam Strong Post TL-3 FLEAT 350 Energy Absorbing Terminal
H-APP-B1-24
RDG-B1.6
W-Beam Strong Post TL-3 FLEAT-MT Energy Absorbing Terminal for Median Applications
H-APP-B1-25
APPENDIX B1-i
TABLE OF CONTENTS
Alberta Transportation Roadside Design Guide
March 2016
Appendix B1 Alberta Weak Post and Strong Post W-Beam Guardrail TABLE OF CONTENTS Dwg. No.
RDG-B1.7 RDG-B1.8 RDG-B1.9 RDG-B1.10 RDG-B1.11
Drawing Title
W-Beam Strong Post Median or Gore Area Termination TL-3 CAT 350 Terminal W-Beam Strong Post to Modified Thrie Beam Guardrail Transition at Roadside Structure Transition of Weak Post W-Beam Guardrail to Strong Post W-Beam Guardrail Strong Post W-Beam Guardrail for Mountable and Semi-Mountable Curb Typical Strong Post W-Beam Guardrail TL-3 End Treatment with Curb and Gutter Transition
Page Number
H-APP-B1-26 H-APP-B1-27 H-APP-B1-28 H-APP-B1-29 H-APP-B1-30
TEB 3.11a
Strong Post W-Beam Blocked Out Terminal End Treatment, Wing End
H-APP-B1-31
TEB 3.11b
Weak Post W-Beam Terminal End Treatment, Wing End
H-APP-B1-32
RDG-B1.12
Typical Material Widening for W-Beam and Thrie Beam Barrier Installations
H-APP-B1-33
TABLE OF CONTENTS
APPENDIX B1-ii
4
152
NUT 152X203 POST
WASHER 203 203
BOLT
3
152X203X360 SPACER BLOCK
4 2
PLAN 2
3810 1905
1905
GROUND LEVEL
ELEVATION
7
320
7
52 108
52 108
LAP IN DIRECTION OF ADJACENT TRAFFIC MOVEMENT (8 SPLICE BOLTS PER LAP) 4
5
6
FACE OF RAIL
POST BOLT
SLOTS 23 X 29 ONE SPLICE BOLT REQUIRED FOR EACH SLOT
REFLECTOR TO BE INSTALLED ON EVERY 6th POST. REFER TO DRAWING TEB 3.01 FOR REFLECTOR DETAILS
POST
SPACER BLOCK
EDGE OF PAVEMENT
89 mm LONG GALVANIZED NAIL
7
24
RAIL SPLICE DETAIL
550
203 4
Dimensions, revised. Galvanized nail and 360
7
notes 2 and 3 added Reflector Note Revised
6
4
S HOUL DE R
MIN. 10:1 SLOPE
NO R SL MA L OP E
PM
8 JUL 09
5
03/23/07
4
Reflector Note and Added Post Dimensions BK
08/11/06
2
0.6m
HC 11 MAR 2016
Reflector Note Revised (Include Type IX) BK
203
1830
2
706
180
3
3
Dimensions and Reflector Detail
BK
12/07/05
2
Notes and Dimensions
BK
12-04
REVISIONS
BY
06-95
1 No.
DATE
BACK FILL AND FIRMLY TAMPED
Approved:
2
Original signed by A.D. Cherwenuk
POST AND SPACER DETAILS
Executive Director, Technical Standards Branch
Transportation Date:
2
3
DECEMBER 11, 1992
7
NOTE: 1. THE STANDARD POST LENGTH FOR STRONG POST SYSTEM IS 1830mm (6'0"). OTHER POST LENGTHS MAY BE USED IF
STRONG POST W-BEAM
DIRECTED BY THE ENGINEER. 2. REFER TO DRAWING TEB 3.01 FOR SPACER BLOCK AND POST DETAILS
BLOCKED-OUT GUARDRAIL
3. 89 mm LONG GALVANIZED NAIL TO PREVENT BLOCK ROTATION
All dimensions are in millimetres unless otherwise indicated.
APPENDIX B1
Prepared
Checked
By: M.T
By: B.K
Scale: N.T.S.
Dwg No.:
TEB 3.09
H-APP-B1-7
...\Revisions_2013\teb3_015b.dgn 6/27/2013 1:26:30 PM
...\Revisions_2013\teb3_016b.dgn 6/27/2013 1:31:57 PM
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B1-14
APPENDIX B1
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
_____________________________________________________________________________________________________________________________________________________
THIS PAGE LEFT INTENTIONALLY BLANK
H-APP-B1-16
APPENDIX B1
C POST L
C POST L
C POST L LENGTH OF NEED
1905
76
1905
1905
TYPICAL STRONG POST SPACING
(TYP)
1 L 75 x 75 x 6 152 x 203 TREATED
ANGLE STRUT
WOOD POST (SEE NOTE 8)
19 DIA ANCHOR CABLE
1
152 x 203 WOOD POST
152 x 203 x 360 LONG
(TYP)
TREATED TIMBER SPACER (SEE NOTE 8)
WING END TERMINAL SECTION
BCT CABLE ANCHOR BRACKET
W-BEAM GUARDRAIL
TRAFFIC FLOW
SEE TEB 3.11a
WOOD, STEEL OR PLASTIC POSTS
PLAN
MAY BE USED
1080 LONG TREATED
(SEE NOTE 8)
1080 LONG TREATED
BREAKAWAY
4 -16 DIA SPLICE BOLTS
TIMBER POST
WITH NUTS
1
TIMBER POST
W-BEAM GUARDRAIL
C RAIL L
PLATE
L75 x 75 x 6
20 x 40 SLOTTED
ANGLE STRUT
HOLE IN ANGLE
75
BCT BEARING
M AX
550
BCT CABLE ANCHOR BRACKET
GROUND LINE
SCHEDULE PIPE SLEEVE
16 DIA x 250 LONG
INSIDE 64 DIA HOLE
BOLT, NUT AND WASHER 230
ON EACH SIDE
430
50 DIA x 150 STANDARD
BOTTOM OF WOOD POST
610 x 460 x 6 SOIL PLATE C/W 2 - 19 DIA x 240 LONG BOLT, NUT,
TREATED TIMBER
AND 2 HIGH STRENGTH WASHERS
POST
(TYP) FOUNDATION TUBE
1525 LONG
1525 LONG
FOUNDATION TUBE
ELEVATION
NOTES: 1.
1
THIS END TREATMENT IS ACCEPTABLE FOR USE ON THE LEAVING END OF DIVIDED ROADWAYS ONLY. USE IN MEDIAN APPLICATIONS ARE LIMITED TO
2
INSTALLATIONS OUTSIDE THE CLEAR ZONE OF OPPOSING TRAFFIC. 2.
POSTS ARE TO BE SET BY INSTRUMENT FOR ALIGNMENT AND GRADE.
3.
BCT CABLE ANCHOR HARDWARE SHALL CONFORM TO AASHTO TASK FORCE 13
4.
LAP ALL GUARDRAIL SECTIONS IN THE DIRECTION OF TRAFFIC FLOW.
REPORT "A GUIDE TO STANDARDIZED HIGHWAY BARRIER HARDWARE."
5.
ALL REQUIRED FITTINGS AND HARDWARE SHALL BE GALVANIZED.
6.
CABLE ANCHOR SHALL BE TIGHTENED DURING INSTALLATION
7.
REFER TO RGD-B1.2 AND RDG-B1.3 FOR STANDARD HARDWARE DETAILS.
8.
TYPICAL STRONG POST SYSTEM CAN BE WOOD, STEEL OR PLASTIC POST WITH
NOTE 8 ADDED
1 No.
HC 11 MAR 2016 BY
REVISIONS
DATE
Approved:
TO TAKE OUT ANY SLACK.
Moh Lali
WOOD SPACER BLOCK. REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS.
For Executive Director, Technical Standards Branch
INFRASTRUCTURE AND TRANSPORTATION
Date:
NOVEMBER, 2007
W-BEAM CABLE ANCHOR TERMINAL (EXIT END TREATMENT FOR DIVIDED HIGHWAYS) ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
H-APP-B1-20
Prepared
Checked
Scale:
By: MO
By: WS
N.T.S.
Dwg No.:
RDG-B1.1
APPENDIX B1
POST1 C L EM RUDERSYST USEXT PL ET
POST6 C L
5 0 9 1
5 0 9 1
STRONG POST GUARDRAIL
SIDE SLOPE TRANSITION
POST3 C L
5 0 9 1 SI TESPECI FI C
5 0 9 1
STANDARD W-BEAM
POST5 C L
POST4 C L
POST2 C L
5 0 9 1
3 000 MINIMUM
5 0 9 1
SI DE SLOPE
POST7 C L
6 1
CABLE ANCHOR
GROUND LINE
BRACKET
STRUT
CABLE
GUIDERAIL EXIT SLOT TO BE
ASSEMBLY
POINTED AWAY FROM TRAFFIC
10H ( MI N):1V
(600 MIN OFFSET FROM BACK OF POSTS)
ET-PLUS IMPACT HEAD W - BEAM GUARDRAIL
INSTALL GUARDRAIL PARALLEL TO EDGE OF
1
SHOULDER. WHEN FLARE IS REQUIRED BY
C L POST 7
C L POST 6
EDGE OF FINISHED PAVEMENT
EXTRUDER TERMINAL PLAN
ENGINEER A 25:1 OR FLATTER FLARE IS ALLOWED
C L POST 5
C L POST 4
TRAFFIC FLOW
C L POST 3
C L POST 1
C L POST 2 DO NOT BOLT W-BEAM
SPLICE (TYP)
ET-PLUS IMPACT HEAD
GUARDRAIL AT POST 1
W - BEAM GUARDRAIL
550
C RAIL L TOP OF FINISHED ROADWAY AT EDGE OF PAVEMENT
2
REFER TO THE MANUFACTURER FOR
EXTRUDER TERMINAL ELEVATION
THE LATEST DRAWINGS AND SPECIFICATIONS
NOTES:
C POST 1 L BREAKAWAY TREATED
1.
TIMBER POST
THE ET PLUS EXTRUDER SYSTEM DEPICTED ON THIS DRAWING IS PROPRIETARY TO TRINITY INDUSTRIES, INC. AND MEETS THE
W-BEAM GUARDRAIL C/W BOLT, HEX NUT AND WASHER (TYP)
REQUIREMENTS OF NCHRP REPORT 350 FOR TEST LEVEL 3 (TL-3).
BREAKAWAY
THE INSTALLATION OF THIS SYSTEM SHALL BE AS PER THE TRINITY
TREATED TIMBER POST
152 x 203 x 1830 LONG PIPE SLEEVE
2.
(SEE NOTE 4)
INSERTED INTO
19 DIA x 240
POST
HIGH STRENGTH CABLE BEARING
GROUND LINE
PLATE
64 DIA BREAK AWAY
CABLE END FITTING
SIDE SLOPE
WITH HEX NUT
(TYP.)
THIS DRAWING SHOWS THE INSTALLATION OF THE RIGHT SHOULDER EXTRUDER TERMINAL IS INVERTED FOR
HC
11 MAR 2016
1
REVISED FLARE NOTE
PM
2 JUL 13
BY
DATE
No.
REVISIONS
UNIDIRECTIONAL TRAFFIC.
(TYP)
3.
10 (MIN) :1
HOLE
STRUT
REFER TO MANUFACTURER NOTE ADDED
SHOULDER EXTRUDER TERMINAL. INSTALLATION OF THE LEFT
600 MIN
BOLT
2
INSTALLATION INSTRUCTIONS MANUAL.
TREATED TIMBER POST
Approved:
RAIL SECTIONS ARE TO BE LAPPED IN THE DIRECTION OF TRAFFIC FLOW.
SITE SPECIFIC SIDE SLOPE
SITE SPECIFIC SIDE SLOPE
4.
ALTERNATE POST SIZES AND TYPES FOR POSTS 1 TO 7 INCLUSIVE MAY BE USED AS SPECIFIED IN THE TRINITY INSTALLATION
AND WASHER
Allan Kwan
INSTRUCTIONS MANUAL.
(TYP EACH END) 5. HEX HEAD BOLT C/W
BOTTOM OF
SOIL BEARING PLATE
19 DIA x 240 LONG
C/W BOLTS, NUTS AND
HEX HEAD BOLT WITH
WASHERS
2 HIGH STRENGTH WASHERS (TYP x 2)
MUST BE MAINTAINED STRAIGHT OVER THE LENGTH OF THE
90 DIA BREAKAWAY
2 WASHERS (TYP)
WOOD POST
SYSTEM. REFER TO THE TRINITY INSTALLATION INSTRUCTIONS
HOLES
TO ENSURE PROPER DELINEATION, REFLECTIVE SHEETING ON THE
TRANSPORTATION
Date: NOVEMBER, 2007
FRONT FACE OF THE EXTRUDER HEAD SHALL BE PROVIDED AS PART OF THE INSTALLED SYSTEM.
SOIL BEARING PLATE C/W 7.
ALL FITTINGS AND HARDWARE SHALL BE GALVANIZED.
8.
POST 3 MARKS THE BEGINNING OF THE CALCULATED LENGTH OF
W-BEAM STRONG POST
NEED. 9.
STEEL
A MAXIMUM FLARE RATE OF 25 TO 1 IS ACCEPTABLE TO OFFSET THE IMPACT HEAD AWAY FROM EDGE OF SHOULDER.
FOUNDATION TUBE (SEE NOTE 4)
10. POSTS SHALL BE SET BY INSTRUMENT FOR ALIGNMENT AND GRADE. 11. TOP OF FOUNDATION TUBES SHALL BE SET BETWEEN 64 AND 76 ABOVE
POST 1 ELEVATION
INFRASTRUCTURE AND
OFFSETS.
STEEL (SEE NOTE 4)
Executive Director, Technical Standards Branch
MANUAL FOR LIMITATIONS, INCLUDING MAXIMUM TERMINAL
6.
BOLTS, NUTS AND WASHERS
FOUNDATION TUBE
FOR INSTALLATION ON A CURVE, THE ET PLUS EXTRUDER SYSTEM
POST 2 SECTION
DO NOT BOLT W-BEAM
POSTS 3, 4, 5, 6 AND 7 SECTION
THE TOP OF PAVED SHOULDER EDGE AND SHALL NOT PROJECT MORE
TL-3 ET-PLUS EXTRUDER ENERGY ABSORBING TERMINAL
THAN 100 ABOVE THE FINISHED SIDE SLOPE GRADE AT POST.
GUARDRAIL TO POST 1
POST DETAILS ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
APPENDIX B1
Prepared
Checked
Scale:
By: MO
By: WS
N.T.S.
Dwg No.:
RDG-B1.4 H-APP-B1-23
OST1 C LP
OST2 C LP
EM NALSYST ERMI 0T 5 EAT3 L F 4 T S O P C L
OST7 C LP
OST5 C LP
STANDARD W-BEAM STRONG POST
OST6 C LP
GUARDRAIL SPACING
OST3 C LP
5 0 9 1
5 0 9 1
5 0 9 1
5 0 9 1
5 0 9 1
3 000 MINIMUM
5 0 9 1
1 SI DE SLOPE
(600 MIN OFFSET FROM
CABLE ASSEMBLY
STRUT
FLEAT IMPACT HEAD W - BEAM GUARDRAIL
FLEAT-350 PLAN
C L POST 7
C L POST 6
C L POST 5
TRAFFIC FLOW
EDGE OF FINISHED PAVEMENT
C L POST 4
C L POST 3
10H ( MI N):1V
GROUND LINE
BRACKET
VARI ES
CABLE ANCHOR
760 -1220
10H ( MI N):1V
BACK FACE OF POSTS)
10H ( MI N):1V
SI TE SPECI FI C
6 SIDE SLOPE TRANSITION
C L POST 2
C L POST 1 FLEAT IMPACT HEAD
W - BEAM GUARDRAIL
SPLICE (TYP)
DO NOT BOLT W-BEAM
DO NOT BOLT W-BEAM
GUARDRAIL AT POST 3
GUARDRAIL AT POST 1
550
C LRAIL GROUND LINE STRUT
TOP OF FINISHED ROADWAY AT EDGE OF PAVEMENT
1
FLEAT-350 ELEVATION
REFER TO THE MANUFACTURER FOR THE LATEST DRAWINGS AND SPECIFICATIONS
NOTES:
C POST 1 L BREAK AWAY TREATED TIMBER POST TREATED TIMBER
TREATED TIMBER POST
SPACER
152 x 203 x 1830 LONG
1. THE FLEAT 350 SYSTEM DEPICTED ON THIS DRAWING IS PROPRIETARY TO ROAD SYSTEMS INC (RSI) AND
BREAKAWAY
MEETS THE REQUIREMENTS OF NCHRP REPORT 350
TREATED TIMBER W-BEAM GUARDRAIL C/W BOLT, NUT AND PIPE SLEEVE
SYSTEM SHALL BE AS PER THE RSI INSTALLATION MANUAL.
W-BEAM GUARDRAIL SIDE SLOPE VARIES TO ACCOMODATE PROJECTION OF FOUNDATION TUBE (TYP) (SEE NOTE 4)
WASHER
INSERTED INTO POST 64 DIA BREAK AWAY HOLE CABLE BEARING PLATE
GROUND LINE
FOR TEST LEVEL 3 (TL-3). THE INSTALLATION OF THIS
POST C/W BOLT, NUT AND WASHER
2.THIS DRAWING SHOWS THE INSTALLATION OF THE RIGHT
2
REFER TO MANUFACTURER NOTE ADDED
1
INSTALLATIONS, SUCH AS FOR UNIDIRECTIONAL TRAFFIC
(TYP)
No.
REVISIONS
TERMINAL SHOWN IS INVERTED. SITE SPECIFIC SIDE SLOPE
SITE SPECIFIC SIDE SLOPE
HEX NUT AND WASHER
11 MAR 2016
BY
DATE
OR DIVIDED HIGHWAYS WITH WIDE MEDIANS, THE EXTRUDER
STRUT CABLE END FITTING C/W
HC
SHOULDER EXTRUDER TERMINAL. FOR LEFT SHOULDER
600 MIN
Approved:
3.RAIL SECTIONS ARE TO BE LAPPED IN THE DIRECTION OF TRAFFIC FLOW.
(TYP EACH END)
4.TOP OF FOUNDATION TUBES SHALL BE SET BETWEEN
Allan Kwan
64 AND 76 ABOVE THE TOP OF PAVED SHOULDER EDGE BOTTOM OF WOOD POST
HEX HEAD BOLT C/W
90 DIA BREAKAWAY
2 WASHERS (TYP)
HOLES
AND SHALL NOT PROJECT MORE THAN 100 ABOVE THE FINISHED SIDE SLOPE GRADE AT POST. 5.FOR POSTS 1 AND 2, THE FOLLOWING FOUNDATION TUBES
Executive Director, Technical Standards Branch
MAY BE USED: SOIL BEARING PLATE
INFRASTRUCTURE AND TRANSPORTATION
a. 1830 LONG SPLIT OR SOLID FOUNDATION TUBES
C/W BOLTS, NUTS
19 DIA x 240 LONG
AND WASHERS
HEX HEAD BOLT WITH
WITHOUT SOIL BEARING PLATES.
2 HIGH STRENGTH WASHERS
SOIL BEARING PLATE C/W
(TYP x 2)
BOLTS, NUTS AND WASHERS
b. 1524 LONG SOLID OR 1370 LONG SOLID FOUNDATION
Date:
NOVEMBER, 2007
TUBES WITH SOIL BEARING PLATES. 6.TO ENSURE PROPER DELINEATION, REFLECTIVE SHEETING ON THE FRONT FACE OF THE FLEAT 350 HEAD SHALL BE
STEEL FOUNDATION TUBE (SEE NOTE 5)
PROVIDED AS PART OF THE INSTALLED SYSTEM. STEEL FOUNDATION TUBE
W-BEAM STRONG POST
7.POST 3 MARKS THE BEGINNING OF THE CALCULATED
(SEE NOTE 5)
LENGTH OF NEED. 8.ALL FITTINGS AND HARDWARE SHALL BE GALVANIZED.
POST
1 ELEVATION
POST 2 SECTION
AND GRADE.
ENERGY ABSORBING TERMINAL
POST DETAILS ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
H-APP-B1-24
TL-3 FLEAT 350
9. POSTS SHALL BE SET BY INSTRUMENT FOR ALIGNMENT
(DO NOT BOLT W-BEAM GUARDRAIL TO POST 3)
DO NOT BOLT W-BEAM GUARDRAIL TO POST 1
POSTS 3, 4, 5, 6, AND 7 SECTION
Prepared
Checked
Scale:
By: MO
By: WS
N.T.S.
Dwg No.:
RDG-B1.5
APPENDIX B1
CPOST L 1
1 9 0 5
CPOST L 2
1 9 0 5
C LPOST 4
C LPOST 5
1905
C LPOST 6
1905
MEDIAN GUARDRAIL
SIDE SLOPE TRANSITION
CABLE ASSEMBLY
FLEAT-MT IMPACT HEAD
SHORT 1905
6 GROUND LINE
CABLE ANCHOR
STRUT
BRACKET
CABLE ANCHOR
W - BEAM
W - BEAM
BRACKET
GUARDRAIL
GUARDRAIL
1
REFER TO THE MANUFACTURER FOR W - BEAM
THE LATEST DRAWINGS AND SPECIFICATIONS
GUARDRAIL 610
10H ( MI N):1V
STANDARD W - BEAM STRONG POST
1905
600
1
SEE NOTE 2
WI DE M EDI AN
3 000 MIN
C LPOST 7
FLEAT MT TERMINAL SYSTEM
CPOST L 3
SI DE SLOPE
SI TE SPECI FI C
1 9 0 5
CABLE ASSEMBLY
FLEAT-MT IMPACT HEAD
W - BEAM EDGE OF FINISHED PAVEMENT
NOTES:
GUARDRAIL
FLEAT-MT TERMINAL PLAN
TRAFFIC FLOW
1.
THE FLEAT MT SYSTEM DEPICTED ON THIS DRAWING IS PROPRIETARY TO ROAD SYSTEMS, INC (RSI) AND MEETS THE
FOR WIDE MEDIANS ONLY
REQUIREMENTS OF NCHRP REPORT 350 FOR TEST LEVEL 3 (TL-3). THE INSTALLATION OF THIS SYSTEM SHALL BE AS PER THE RSI INSTALLATION MANUAL.
C L POST 2
C L POST 1
C L POST 3
C L POST 4
C L POST 5
DO NOT BOLT W-BEAM
C L POST 6
C L POST 7
2.
APPLICATION OF THIS SYSTEM SHALL ONLY BE USED FOR WIDE MEDIANS SUCH THAT THE INSTALLED SYSTEM CAN BE
SPLICE (TYP)
PHYSICALLY LOCATED OUTSIDE THE CLEAR ZONE FOR THE
GUARDRAIL AT POST 1
OPPOSING TRAFFIC.
TOP OF FINISHED ROADWAY
550
C RAIL L
3.
RAIL SECTIONS ARE TO BE LAPPED IN THE DIRECTION OF TRAFFIC FLOW.
4.
TOP OF FOUNDATION TUBES SHALL BE SET BETWEEN 64 AND 76 ABOVE TOP OF PAVED SHOULDER EDGE AND SHALL NOT
AT EDGE OF PAVEMENT
PROJECT MORE THAN 100 ABOVE THE FINISHED SIDE SLOPE GRADE AT POST. 5.
FOR POSTS 1, 2 AND 4 THE FOLLOWING FOUNDATION TUBES MAY BE USED: a. 1830 LONG SPLIT OR SOLID FOUNDATION TUBES WITHOUT SOIL BEARING PLATES. b. 1524 LONG SOLID OR 1370 LONG SOLID FOUNDATION TUBES WITH SOIL BEARING PLATES.
6.
FOR POSTS 3, 5, 6 AND 7, PLUG WELDED STEEL BREAKAWAY POSTS MAY BE USED IN LIEU OF TREATED TIMBER POSTS AS PER RSI GUIDELINES, PROVIDED THAT THE APPROPRIATE INSTALLATION HARDWARE IS USED TO MAINTAIN COMPLIANCE WITH TL-3.
FLEAT-MT TERMINAL ELEVATION
7.
TO ENSURE PROPER DELINEATION, REFLECTIVE SHEETING OBJECT MARKER ON THE FRONT FACE OF THE FLEAT MT HEAD SHALL BE PROVIDED AS PART OF THE INSTALLED SYSTEM.
C POST 1 L BREAKAWAY
BREAKAWAY
DO NOT ATTACH W-BEAM
152 x 203 x 1830 LONG (TYP)
GUARDRAIL TO POST 4
8.
OF NEED. 9.
TREATED TIMBER POST
POST W-BEAM GUARDRAIL
TREATED TIMBER
CRT TREATED TIMBER POST
SPACER (TYP)
152 x 203 x 1830 LONG
POST 3 MARKS THE BEGINNING OF THE CALCULATED LENGTH
FLEAT IMPACT HEAD
ON THIS SIDE ONLY
TREATED TIMBER
TREATED TIMBER POST
TREATED TIMBER POST
ALL FITTINGS AND HARDWARE SHALL BE GALVANIZED.
10. POSTS SHALL BE SET BY INSTRUMENT FOR ALIGNMENT AND GRADE.
152 x 203 x 1830 LONG
C/W BOLT, NUT AND WASHER
W-BEAM GUARDRAIL
2 W-BEAM GUARDRAIL
PIPE SLEEVE
C/W BOLT, HEX NUT
INSERTED INTO POST 1
64 DIA BREAK AWAY HOLE
CABLE BEARING
GROUND LINE
PLATE
STRUT
CABLE END FITTING
REFER TO MANUFACTURER NOTE ADDED
1
HC
11 MAR 2016
BY
DATE
AND WASHER SIDE SLOPE VARIES TO ACCOMODATE PROJECTION OF FOUNDATION TUBE (TYP) (SEE NOTE 4)
No.
REVISIONS
64 DIA BREAK AWAY HOLE
Approved: 10 (MIN) : 1 SIDE SLOPE
WITH HEX NUT AND WASHER (TYP EACH END)
Allan Kwan
HEX HEAD BOLT C/W 2 WASHERS
BOTTOM OF
(TYP)
WOOD POST 19 DIA x 240 LONG
SOIL BEARING PLATE C/W
HEX HEAD BOLT WITH
BOLTS, NUTS AND WASHERS
90 DIA BREAKAWAY
90 DIA BREAKAWAY
HOLE (TYP)
HOLE (TYP)
SOIL BEARING PLATE C/W
SOIL BEARING PLATE C/W
BOLTS, NUTS AND WASHERS
BOLTS, NUTS AND WASHERS
STEEL
STEEL
STEEL
FOUNDATION TUBE
FOUNDATION TUBE
FOUNDATION TUBE
(SEE NOTES 4 AND 5)
(SEE NOTES 4 AND 5)
(SEE NOTES 4 AND 5)
POST 1 ELEVATION DO NOT BOLT W-BEAM GUARDRAIL TO POST 1
POST 2 SECTION
POST 3 SECTION
POST 4 SECTION
Date:
NOVEMBER, 2007
W-BEAM STRONG POST
POSTS 5, 6, AND 7 SECTION
DO NOT BOLT W-BEAM GUARDRAIL TO POST 3
TL-3 FLEAT MT ENERGY ABSORBING TERMINAL FOR MEDIAN APPLICATIONS
POST DETAILS ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
APPENDIX B1
INFRASTRUCTURE AND TRANSPORTATION
2 HIGH STRENGTH WASHERS (TYP x 2)
Executive Director, Technical Standards Branch
Prepared
Checked
Scale:
By:MO
By: WS
N.T.S.
Dwg No.:
RDG-B1.6 H-APP-B1-25
C POST 6 L CAT-350 TERMINAL CRASH CUSHION
TRAFFIC FLOW
W-BEAM STRONG POST MEDIAN GUARDRAIL SYSTEM
END TREATMENT
C POST 1 L
C POST 2 L
C POST 3 L
C POST 4 L
1905
1905
(FOR TRANSITION TO CONCRETE MEDIAN BARRIER SEE DRAWING RDG-B6.12)
C POST 5 L
1905
C POST 7 L
1905
1905
C POST 8 L
1905
1905 (SEE NOTE 7)
SLEEVE CHANNEL STRUT RESTRAINING SPACER
POST PLATES
ROD
CHANNEL
RESTRAINING ROD
KNOCK-OUT BLOCK
2.7 SLOTTED GUARDRAIL
TRAFFIC FLOW
CAT-350 TERMINAL
C POST 1 L
C POST 2 L
SIDE PLATE
CABLE ANCHOR REQUIRED ONLY
3.4 SLOTTED GUARDRAIL
CAT-350 TERMINAL PLAN
(TYP BOTH SIDES)
C POST 3 L
FOR SHOULDER APPLICATIONS.
(TYP BOTH SIDES)
C POST 4 L
(SEE NOTE 7)
C POST 5 L
C POST 6 L
C POST 7 L
C POST 8 L
NOSE
550
C LRAIL
TOP OF FINISHED ROADWAY
CABLE ANCHOR
AT EDGE OF PAVEMENT
CHANNEL STRUT
NOTES: 1.
THE CAT-350 SYSTEM DEPICTED ON THIS DRAWING IS PROPRIETARY TO TRINITY INDUSTRIES, INC AND MEETS THE REQUIREMENTS OF NCHRP REPORT 350 FOR TEST LEVEL 3 (TL-3). THE INSTALLATION OF THIS SYSTEM SHALL BE AS PER THE TRINITY INSTALLATION INSTRUCTIONS MANUAL.
2.
SUBSTITUTION OF PARTS (POSTS, FOUNDATION TUBES AND CHANNEL STRUT) SHOWN ON THIS DRAWING IS PERMITTED WITH OTHER APPROVED CAT SYSTEM PARTS AS SPECIFIED IN THE TRINITY INSTALLATION INSTRUCTIONS MANUAL, PROVIDED THAT THE APPROPRIATE INSTALLATION HARDWARE IS USED TO MAINTAIN COMPLIANCE WITH TL-3.
CAT-350 TERMINAL ELEVATION
1
3.
MAXIMUM PROJECTION OF FOUNDATION TUBE ABOVE FINISHED GRADE SHALL NOT EXCEED 100.
4.
CAT RAIL SPLICE BOLTS SHALL BE USED AT POSTS 4 AND 6 TO ENSURE PROPER PERFORMANCE OF THE SYSTEM DURING IMPACT. THESE BOLTS ARE DESIGNED TO ALLOW TELESCOPING ACTION OF RAIL SLIDING ON RAIL.
REFER TO THE MANUFACTURER FOR THE LATEST DRAWINGS AND SPECIFICATIONS
5.
RAIL SECTIONS ARE TO BE LAPPED IN THE DIRECTION OF TRAFFIC FLOW.
6.
DO NOT ATTACH RAIL ELEMENTS TO POSTS 3, 5 AND 6.
7.
A 3810 LONG CAT-350 TAIL-END SECTION SHALL BE PROVIDED FROM POST 6 TO POST 8 WHEN LESS THAN 11 430 OF W-BEAM MEDIAN GUARDRAIL IS INSTALLED BEYOND POST 6. FOR SHOULDER APPLICATIONS WHEN TRANSITIONING THE CAT-350 TERMINAL TO A SINGLE SIDED
TREATED TIMBER
NOTCHED BREAKAWAY
BREAKAWAY TREATED
TREATED TIMBER POST
TIMBER POST (TYP)
W-BEAM GUARDRAIL, A CABLE ATTACHMENT AND ANCHORAGE ASSEMBLY IS REQUIRED BETWEEN POSTS 6 AND 7. DETAILS FOR BOTH TYPES OF TRANSITIONS MAY BE OBTAINED FROM
POST PLATE
KNOCKOUT BLOCK
TRINITY.
KNOCKOUT
BENT PLATE SLEEVE
SPACER (TYP)
BOLTS AND NUTS WITH 2 RECTANGULAR WASHERS
SPLICE BOLTS, NUTS,
BOLTS, NUTS
SPLICE BOLTS, NUTS
AND WASHERS
AND WASHERS,
AND WASHERS
(TYP)
(TYP)
(TYP)
BLOCK
8.
ALL FITTINGS AND HARDWARE SHALL BE GALVANIZED.
9.
POST 4 MARKS THE BEGINNING OF THE CALCULATED LENGTH OF NEED.
10. TO ENSURE PROPER DELINEATION, REFLECTIVE SHEETING SHALL BE PLACE ON THE NOSE AND SHALL BE PROVIDED AS PART OF THE INSTALLED SYSTEM.
2 CABLE BEARING
PIPE INSERTED
PLATE
BREAKAWAY
IN POST
HEX HEAD BOLT
PIPE INSERTED
WITH 2 WASHERS
IN POST
REFER TO MANUFACTURER NOTE ADDED
1
BACKING PLATE
HOLE (TYP)
HC
11 MAR 2016
BY
DATE
WELDED TO GUARDRAIL
CHANNEL
No.
(BOTH SIDES)
STRUT
REVISIONS
(TYP)
Approved:
Allan Kwan
Executive Director, Technical Standards Branch
SOIL BEARING PLATE
INFRASTRUCTURE AND
C/W BOLTS, NUTS AND
TRANSPORTATION
WASHERS (TYP)
Date:
NOVEMBER, 2007
STEEL FOUNDATION (TYP)
W-BEAM STRONG POST POST 1
POST 2
POSTS 3 AND 5
POST 4
MEDIAN OR GORE AREA
POST 6
TERMINATION POST DETAILS
TL-3 CAT 350 TERMINAL ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
H-APP-B1-26
Prepared
Checked
Scale:
By:MO
By: WS
N.T.S.
Dwg No.:
RDG-B1.7
APPENDIX B1
C L POST CENTRE FOR LENGTH OF HAZARD
C L POST 953
C L POST
C L POST
C L POST 1905
953
953
POSTS AT 1905 ON CENTRE (LENGTH OF NEED OF W-BEAM STRONG POST
HAZARD
SIDE SLOPE TRANSITION (600 MIN OFFSET FROM BACK FACE OF MODIFIED THRIE BEAM POSTS)
10H ( MI N):1V
= 600 MIN
AS DETERMINED BY THE CONSULTANT) SI DE SLOPE
AS DETERMINED BY THE CONSULTANT
C L POST 953
SI TE SPECI FI C
POSITION POSTS AT 1905 ON
HAZARD
C L POST 4 SPACES AT 1 905 = 7 620
LENGTH OF GUARDRAIL
W - BEAM GUARDRAIL
THRIE BEAM GUARDRAIL
EDGE OF FINISHED PAVEMENT
PLAN
C L POST
ROADSIDE
C L POST
STRUCTURE
C L POST
MODIFIED THRIE BEAM GUARDRAIL
TRANSITION
HEIGHT TRANSITIONING FROM 550 TO 610
(SEE DRAWING RDG-B5.5)
(SEE DRAWING RDG-B5.5 FOR DETAILS) 1905 (TYP)
C L POST 953
C L POST
C L POST 1905
953
C L POST
C L POST 1905 (TYP)
1905 (TYP)
A HAZARD
HAZARD
-
W-BEAM STRONG POST GUARDRAIL
B
1 LAYER OF 2.7 THICK
1 LAYER 2.7 THICK
THRIE BEAM GUARDRAIL
SPLICE
BACK-UP PLATE
(TYP)
(TYP)
(TYP)
-
W - THRIE BEAM TRANSITION SECTION
W - BEAM GUARDRAIL
C THRIE BEAM L 550
610
C L W-BEAM
TOP OF FINISHED ROADWAY
610
550
AT EDGE OF PAVEMENT
ELEVATION
(SEE NOTE 8)
M360 x 25.6 STEEL OFFSET BLOCK REFLECTIVE TAB
152 x 203 x 360 LONG
(SEE NOTE 7)
TREATED TIMBER
180
25
REFLECTIVE TAB
SPACER
EDGE OF SHOULDER
W - BEAM GUARDRAIL
1 2
1. FOR GENERAL LAYOUT REFER TO TEB DRAWINGS 3.15a AND 3.18. 2. WHERE GUARDRAIL IS ADJACENT TO CURB, HEIGHT OF RAIL SHALL BE MEASURED
600 MIN
a.VERTICALLY AT FACE OF GUARDRAIL WHEN FACE OF GUARDRAIL IS MORE THAN
10 (MIN) : 1 SIDE SLOPE
SITE SPECIFIC SIDE SLOPE
No.
REVISIONS
BY
DATE
Approved:
b.VERTICALLY AT GUTTER LINE WHEN FACE OF GUARDRAIL IS 300 OR LESS BEYOND SITE SPECIFIC SIDE SLOPE
GUTTER LINE. 3. POSTS SHALL BE SET BY INSTRUMENT FOR ALIGNMENT AND GRADE, WITH TOP PARALLEL TO PAVEMENT GRADE. 4. THE ACCEPTABLE TOLERANCE FOR HEIGHT OF GUARDRAIL AT TIME OF
1100
RECENT SPECIFICATIONS. 1170
8 JUL 09
300 BEYOND GUTTER LINE.
CONSTRUCTION OR MAINTENANCE SHALL BE IN ACCORDANCE WITH THE MOST
5. LAP ALL JOINTS IN THE DIRECTION OF TRAFFIC FLOW. 6. ALL FITTINGS AND HARDWARE REQUIRED SHALL BE GALVANIZED. 7. FASTEN REFLECTOR TO TOP OF EVERY SIXTH GUARDRAIL STRONG POST SPACER BY MECHANICAL MEANS SUCH AS NAILING OR STAPLING. ADHESIVES ALONE WILL NOT BE ACCEPTED. REFER TO DRAWING TEB 3.01 FOR REFLECTOR DETAILS. 8. FASTEN REFLECTOR TO TOP OF EVERY SIXTH GUARDRAIL STEEL OFFSET BLOCK WITH APPROVED ADHESIVE. REFER TO DRAWING TEB 3.01 FOR REFLECTOR DETAILS. 9. THIS TRANSITION SATISFIES NCHRP REPORT 350 REQUIREMENTS FOR TEST LEVEL 3 (TL3).
SECTION A
SECTION B
( FOR DETAILS SEE TEB DRAWING 3.70)
(FOR DETAILS SEE TEB DRAWING 3.09 )
POST DETAILS ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
APPENDIX B1
PM
NOTES 7 AND 8 REVISED
1
AS FOLLOWS:
(TYP) EDGE OF SHOULDER
1830
10 (MIN) : 1 SIDE SLOPE
NOTES:
152 x 203 TREATED TIMBER POST
550
730
610
890
W150 x 13.5 STEEL POST THRIE BEAM GUARDRAIL WITH BACK-UP PLATE
Allan Kwan
D E D6 0 E 1 1 0 . S 2 POST 5 W-BEAM STRONG RCH G-B E TO MODIFIED THRIE BEAM P AR RD GUARDRAIL AT U 1 M rtTRANSITION o S 1 ROADSIDE e STRUCTURE f Executive Director, Technical Standards Branch
Transportation
Date:
NOVEMBER, 2007
Re
Prepared
Checked
Scale:
By: MO
By: WS
N.T.S.
Dwg No.:
RDG-B1.8 H-APP-B1-27
C POST L
C POST L
C POST L
1 905
C POST L
1 905
C POST L
SI TE SPECI FI C SI DE SLOPE
1 905
1 905
STRONG POST
WEAK POST
W-BEAM GUARDRAIL
W-BEAM GUARDRAIL
C POST L
C POST L
1 905
3 810
SIDE SLOPE TRANSITION (600 MIN OFFSET FROM
10H ( MI N):1V
BACK FACE OF POSTS)
152 x 203 TREATED TIMBER POST 152 x 203 152 x 203 x 360 LONG
TREATED TIMBER POST
TREATED TIMBER SPACER
W-BEAM GUARDRAIL
TRAFFIC FLOW
TRANSITION PLAN
REFER TO DRAWING TEB 3.01 FOR REFLECTOR DETAILS. WOOD, STEEL OR PLASTIC POSTS MAY BE USED C L POST
(SEE NOTE 6) 2
C POST L
B
C POST L
C POST L
SPLICE (TYP)
C POST L
STRONG POST
WEAK POST
W-BEAM GUARDRAIL
W-BEAM GUARDRAIL
-
A
C POST L
C POST L
W - BEAM GUARDRAIL
540
C L W-BEAM TOP OF FINISHED ROADWAY AT EDGE OF PAVEMENT
TRANSITION ELEVATION
REFLECTOR TAB SEE NOTE 3
REFLECTOR TAB SEE NOTE 3
GENERAL NOTES:
152 x 203 x 360 LONG TREATED TIMBER SPACER
1
2
1. LAP ALL JOINTS IN THE DIRECTION OF TRAFFIC. 2. THE ACCEPTABLE TOLERANCE FOR HEIGHT OF
2
152 x 203 TREATED
152 x 203 TREATED
TIMBER POST
TIMBER POST
GUARDRAIL AT TIME OF CONSTRUCTION OR MAINTENANCE SHALL BE IN ACCORDANCE WITH THE MOST RECENT SPECIFICATIONS. 3. REFLECTOR TO BE INSTALLED ON EVERY 3RD POST AND
600 MIN (TYP)
1 520
EDGE OF SHOULDER
W - BEAM GUARDRAIL
6TH POST FOR WEAK POST AND STRONG POST RESPECTIVELY 600 MIN
4.POSTS SHALL BE SET BY INSTRUMENT FOR
NOTE 3 REVISED NOTE 6 ADDED
HC
11 MAR 2016
1
NOTE 3 REVISED
PM
8 JUL 09
BY
DATE
ALIGNMENT AND GRADE. EDGE OF SHOULDER
10 (MIN) : 1 SIDE SLOPE
2
REFER TO DRAWING TEB 3.01 FOR REFLECTOR DETAILS.
(TYP)
540
720
W - BEAM GUARDRAIL 540
720
(SEE NOTE 6)
5. ALL FITTINGS AND HARDWARE REQUIRED 10 (MIN) : 1 SIDE SLOPE
SITE SPECIFIC SIDE SLOPE
No.
REVISIONS
SHALL BE GALVANIZED. SITE SPECIFIC SIDE SLOPE
Approved:
6. TYPICAL STRONG POST SYSTEM CAN BE WOOD, STEEL OR
1 830
PLASTIC POST WITH WOOD SPACER BLOCK. REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS.
790
Allan Kwan
1 100
Executive Director, Technical Standards Branch
Transportation Date:
NOVEMBER, 2007
TRANSITION OF WEAK POST SECTION A
W-BEAM GUARDRAIL TO STRONG POST
SECTION B
W-BEAM GUARDRAIL ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
H-APP-B1-28
Prepared
Checked
By:NSP
By: WS
Scale:
Dwg No.:
RDG-B1.9
APPENDIX B1
Alberta Transportation Roadside Design Guide
October 2016
APPENDIX B2 HIGH TENSION CABLE SYSTEM
APPENDIX B2
COVER PAGE
Alberta Transportation October 2016
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B2
Alberta Transportation Roadside Design Guide
October 2016
Appendix B2 High Tension Cable Barrier TABLE OF CONTENTS Dwg. No.
Drawing Title
Page Number
RDG-B2.1
Typical HTCB Median Installation, Slopes 6H:1V or Flatter
H-APP-B2-3
RDG-B2.2
Typical HTCB Median Installation, 6H:1V Slopes 4H:1V
H-APP-B2-4
RDG-B2.3
Typical HTCB Median Installation, Slopes Steeper Than 4H:1V
H-APP-B2-5
RDG-B2.4
Typical HTCB Roadside Installation
H-APP-B2-6
TABLE OF CONTENTS
APPENDIX B2-i
Alberta Transportation October 2016
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
APPENDIX B2-ii
TABLE OF CONTENTS
Alberta Transportation Roadside Design Guide
October 2016
High Tension Cable Barrier System Product Development and Acceptance Testing The Alberta Transportation Products List of proven, trial and potential products for HTCB (including vendor information) is available at the link indicated below.
http://www.transportation.alberta.ca/689.htm As of September 8, 2016 there are five proprietary HTCB systems in North America that have passed NCHRP 350 and/or MASH 2009. They are listed below in alphabetical order. Not all of the tested systems are on the Alberta Transportation Products List.
Brifen Canada 15521 Marine Drive White Rock, BC V4B 1C9, Canada
http://www.brifen.ca
Gibraltar 4303 Innovation Loop Marble Falls, TX 78654, USA
http://gibraltarus.com
Nucor Steel Marion, Inc. 912 Cheney Avenue Marion, Ohio 43302, USA
http://www.nucorhighway.com (Note: Not on Alberta Transportation’s Products List dated September 8, 2016)
SAFENCE (Gregory Industries, Inc.) 4100 13th Street, SW Canton, Ohio 44710, USA
http://www.gregorycorp.com
Trinity Highway Safety Products 2525 North Stemmons Freeway Dallas, Texas 75207, USA
http://www.highwayguardrail.com
APPENDIX B2
H-APP-B2-1
Alberta Transportation October 2016
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B2-2
APPENDIX B2
APPENDI X B2
* PREFERRED PLACEMENT ZONE SUBJECT TO OTHER REQUIREMENTS
TRAVEL LANE
SHOULDER
1.2*
1.2*
SHOULDER
TRAVEL LANE
REFER TO NOTE 5 2.4
2.4
2.4
2.4
NO ZONE
NO ZONE
NO ZONE
NO ZONE
REFER TO NOTE 4
REFER TO NOTE 4
REFER TO NOTE 4
REFER TO NOTE 4
0.3
0.3 0.3
2.4 NO ZONE
6:1 OR FLATTER
2.4 NO ZONE TOE OF SLOPE
TOE OF SLOPE
0.3 0.3
6:1 OR FLATTER
EDGE OF PAVEMENT (SHOULDER BREAKPOINT)
0.3
6:1 OR FLATTER
MEDIAN DITCH WIDTH REFER TO NOTE 4
6:1 OR FLATTER
PREFERRED LOCATION FOR BARRIER BARRIER PERMITTED
V-DITCH MEDIAN SECTION NOTES
1
FLAT BOTTOM DITCH MEDIAN SECTION
1
BARRIER NOT PERMITTED
1
1. HIGH TENSION CABLE BARRIERS (HTCB) ARE PROPRIETARY PRODUCTS AND THEREFORE MUST BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S AND/OR VENDOR'S SPECIFICATIONS. CABLE BARRIER PRODUCTS VARY SUBSTANTIALLY IN DETAILS, SPECIFICATION AND METHOD OF INSTALLATION, ETC. DESIGNERS SHOULD REVIEW THE FHWA (UNITED STATES FEDERAL HIGHWAY ADMINISTRATION) ELIGIBILITY LETTERS IN CONJUNCTION WITH THE MANUFACTURER AND/OR VENDOR'S PRODUCT DETAILS AND SPECIFICATIONS. 2. DESIGNERS SHALL REVIEW THE FHWA ELIGIBILITY LETTERS AND THE TEST DOCUMENTATION UPON WHICH THE LETTERS ARE BASED IN DETAIL. THIS INCLUDES THE SUMMARY RESULTS (E.G. TEST DEFLECTION), TEST SITE CONDITIONS (E.G. POST SPACING, SOIL DATA, ETC.), PRODUCT DETAILS, PROVISIONS, ETC., UNDER WHICH THE PRODUCT WAS TESTED AND ACCEPTED. 3. FHWA ELIGIBILITY LETTERS ARE NORMALLY BASED ON THE HTCB SYSTEM BEING TESTED ON TANGENT IN A
4 3 2 NOTES 1 - 6 AND CROSS SECTIONS
1 No.
REVISIONS
HC BY
28 OCT 16 DATE
CONTROLLED ENVIRONMENT. THE SLOPE PLACEMENT, POST SPACING AND SPECIFIED MAXIMUM
Approved:
DEFLECTION, ETC., MAY NEED TO BE ADJUSTED DUE TO SITE-SPECIFIC CONDITIONS. 4. ACCORDING TO NCHRP REPORT 711, THE HTCB MAY BE PLACED AS FOLLOWS: - ON THE MEDIAN SIDESLOPE, BUT NOT IN THE AREA BETWEEN 0.3 AND 2.4 METRES FROM THE TOE OF THE SLOPE
Steve Otto
- IN THE MEDIAN DITCH WITHIN 0.3 OF THE TOE OF SLOPE, IF THE MEDIAN DITCH IS 2.4 METRES OR WIDER - IF THE MEDIAN DITCH IS LESS THAN 2.4 METRES WIDE, THE HTCB MAY NOT BE PLACED IN ANY PORTION OF THE DITCH BOTTOM 5. HTCB LONGITUDINAL RUNS ARE NORMALLY INSTALLED TO PROTECT BOTH DIRECTIONS OF TRAFFIC. HTCB PLACEMENT AND/OR DESIGN MUST PREVENT INTRUSION OF OPPOSING VEHICLES INTO THE TRAVEL LANE
For Executive Director, Technical Standards Branch
Date: 17 February, 2012
CAUSED BY THE IMPACT TO THE CABLE SYSTEM ON THE BACK-SIDE AFTER CROSSING THE MEDIAN. 6. NO ZONE AREA IN THE MEDIAN WHERE HTCB TYPICALLY MAY NOT BE INSTALLED. 7. POSTS CAN BE PLACED IN SOCKETS IN CONCRETE FOUNDATIONS OR SOCKETS DRIVEN INTO THE
HAPPB23
GROUND DEPENDING ON THE SOIL CONDITION, MANUFACTURER'S SPECIFICATION AND FHWA
TYPICAL HIGH TENSION CABLE BARRIER MEDIAN INSTALLATION
APPROVALS. POSTS DRIVEN DIRECTLY INTO THE GROUND ARE NOT PERMITTED. 8. THE DITCH MAY BE SUBJECT TO WEAK SOILS (OFTEN UNCOMPACTED), PERIODIC FLOODING AND/OR WET SOIL CONDITIONS. THE SOIL STRENGTH MUST BE TAKEN INTO ACCOUNT WHEN
SLOPES 6(H):1(V) OR FLATTER
DESIGNING THE POST FOUNDATIONS AND END ANCHOR FOUNDATIONS.
Prepared 9. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE NOTED.
By: GEC.
Checked By: PM
Scale: N.T.S.
Dwg No.:
RDG-B2.1
HAPPB24
HTCB MAY BE INSTALLED WITHIN 1.2m OF THE EDGE OF THE SHOULDER BREAKPOINT OR GREATER THAN 6.0 METRES FROM THE SHOULDER BREAKPOINT BUT CANNOT BE INSTALLED IN THE NO ZONE AREAS. SEE NOTES 4 AND 5. 6.0 TRAVEL LANE
SHOULDER
1.2
6.0
NO ZONE
2.4
2.4
NO ZONE
NO ZONE
SHOULDER
1.2
NO ZONE
TRAVEL LANE
(REFER TO NOTE 5)
EDGE OF PAVEMENT (SHOULDER BREAKPOINT)
4:1 OR FLATTER
4:1 OR FLATTER
BUT STEEPER THAN 6:1
BUT STEEPER THAN 6:1
TOE OF SLOPE
V-DITCH MEDIAN SECTION NOTES
2.4
2.4
2.4
2.4
NO ZONE
NO ZONE
NO ZONE
NO ZONE
1
1
1. HIGH TENSION CABLE BARRIERS (HTCB) ARE PROPRIETARY PRODUCTS AND THEREFORE MUST BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S AND/OR VENDOR'S
TOE OF SLOPE
SPECIFICATIONS. CABLE BARRIER PRODUCTS VARY SUBSTANTIALLY IN DETAILS, SPECIFICATION
TOE OF SLOPE
FLAT BOTTOM DITCH MEDIAN SECTION
AND METHOD OF INSTALLATION, ETC. DESIGNERS SHOULD REVIEW THE FHWA (UNITED STATES
1
FEDERAL HIGHWAY ADMINISTRATION) ELIGIBILITY LETTERS IN CONJUNCTION WITH THE MANUFACTURER AND/OR VENDOR'S PRODUCT DETAILS AND SPECIFICATIONS.
PREFERRED LOCATION FOR BARRIER BARRIER PERMITTED
2. DESIGNERS SHALL REVIEW THE FHWA ELIGIBILITY LETTERS AND THE TEST DOCUMENTATION
BARRIER NOT PERMITTED
UPON WHICH THE LETTERS ARE BASED IN DETAIL. THIS INCLUDES THE SUMMARY RESULTS (E.G. TEST DEFLECTION), TEST SITE CONDITIONS (E.G. POST SPACING, SOIL DATA, ETC.), PRODUCT DETAILS,
4
PROVISIONS, ETC., UNDER WHICH THE PRODUCT WAS TESTED AND ACCEPTED.
3 3. FHWA ELIGIBILITY LETTERS ARE NORMALLY BASED ON THE HTCB SYSTEM BEING TESTED ON TANGENT IN A CONTROLLED ENVIRONMENT. THE SLOPE PLACEMENT, POST SPACING AND SPECIFIED MAXIMUM DEFLECTION, ETC., MAY NEED TO BE ADJUSTED DUE TO SITE-SPECIFIC CONDITIONS. 4. ACCORDING TO NCHRP REPORT 711, THE HTCB MAY BE PLACED AS FOLLOWS:
2 NOTES 1 - 6 AND CROSS SECTIONS
1 No.
REVISIONS
HC BY
28 OCT 16 DATE
- ON THE SIDESLOPE WITHIN 1.2 METRES OF THE SHOULDER BREAKPOINT (EDGE OF PAVEMENT)
Approved:
- DOWN THE SIDESLOPE AT AN OFFSET GREATER THAN 6.0 METRES FROM THE SHOULDER BREAKPOINT AND GREATER THAN 2.4 METRES FROM THE TOE OF THE SIDESLOPE - IN THE MEDIAN DITCH BOTTOM AT AN OFFSET GREATER THAN 2.4 METRES FROM THE TOE OF THE SIDESLOPE - THE OPTION OF TWO SEPARATE LONGITUDINAL RUNS OF HTCB WITHIN 1.2 METRES OF THE EDGE OF
Steve Otto
BOTH SHOULDER BREAKPOINTS MAY ALSO BE CONSIDERED WHERE SECTIONS OF THE ROADWAY HAVE SLOPES THAT ARE SHARPER THAN 4:1, THE DITCH IS VERY NARROW (NOT ALLOWING THE SPECIFIED OFFSETS AND DEFLECTIONS) OR THERE ARE FIXED HAZARDS IN THE MEDIAN.
For Executive Director, Technical Standards Branch
5. HTCB LONGITUDINAL RUNS ARE NORMALLY INSTALLED TO PROTECT BOTH DIRECTIONS OF TRAFFIC. HTCB PLACEMENT AND/OR DESIGN MUST PREVENT INTRUSION OF OPPOSING VEHICLES INTO THE TRAVEL LANE
Date: 17 February, 2012
CAUSED BY THE IMPACT TO THE CABLE SYSTEM ON THE BACK-SIDE AFTER CROSSING THE MEDIAN. 6. NO ZONE AREA IN THE MEDIAN WHERE HTCB TYPICALLY MAY NOT BE INSTALLED.
APPENDI X B2
7. POSTS CAN BE PLACED IN SOCKETS IN CONCRETE FOUNDATIONS OR SOCKETS DRIVEN INTO THE GROUND DEPENDING ON THE SOIL CONDITION, MANUFACTURER'S SPECIFICATION AND FHWA
TYPICAL HIGH TENSION CABLE BARRIER MEDIAN INSTALLATION
APPROVALS. POSTS DRIVEN DIRECTLY INTO THE GROUND ARE NOT PERMITTED. 8. THE DITCH MAY BE SUBJECT TO WEAK SOILS (OFTEN UNCOMPACTED), PERIODIC FLOODING AND/OR WET SOIL CONDITIONS. THE SOIL STRENGTH MUST BE TAKEN INTO ACCOUNT WHEN DESIGNING THE POST FOUNDATIONS AND
6(H):1(V)> SLOPES > 4(H):1(V)
END ANCHOR FOUNDATIONS.
Prepared 9.
ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE NOTED.
By: GEC.
Checked By: PM
Scale: N.T.S.
Dwg No.:
RDG-B2.2
HAPPB25 TRAVEL LANE
SHOULDER
SHOULDER
NO ZONE
TRAVEL LANE
"HTCB" (3 OR 4 CABLES)
2
2
EDGE OF PAVEMENT (SHOULDER BREAKPOINT) STEEPER THAN 4:1
1
STEEPER THAN 4:1
TOE OF SLOPE
NOTES
1
1. HIGH TENSION CABLE BARRIERS (HTCB) ARE PROPRIETARY PRODUCTS AND THEREFORE MUST BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S AND/OR VENDOR'S SPECIFICATIONS. CABLE BARRIER PRODUCTS VARY SUBSTANTIALLY IN DETAILS, SPECIFICATION AND METHOD OF INSTALLATION, ETC. DESIGNERS SHOULD REVIEW THE FHWA (UNITED STATES FEDERAL HIGHWAY ADMINISTRATION) ELIGIBILITY LETTERS IN CONJUNCTION WITH THE MANUFACTURER AND/OR VENDOR'S PRODUCT DETAILS AND SPECIFICATIONS. 2. DESIGNERS SHALL REVIEW THE FHWA ELIGIBILITY LETTERS AND THE TEST DOCUMENTATION UPON WHICH THE LETTERS ARE BASED IN DETAIL. THIS INCLUDES THE SUMMARY RESULTS (E.G. TEST
4 3 2
CABLES ON MEDIAN SIDE REMOVED
BK
24 AUG 17
1
NOTES 1 - 5 AND CROSS SECTION
HC
28 OCT 16
No.
REVISIONS
BY
DATE
DEFLECTION), TEST SITE CONDITIONS (E.G. POST SPACING, SOIL DATA, ETC.), PRODUCT DETAILS, PROVISIONS, ETC., UNDER WHICH THE PRODUCT WAS TESTED AND ACCEPTED.
Approved:
3. FHWA ELIGIBILITY LETTERS ARE NORMALLY BASED ON THE HTCB SYSTEM BEING TESTED ON TANGENT IN A CONTROLLED ENVIRONMENT. THE SLOPE PLACEMENT, POST SPACING AND SPECIFIED MAXIMUM DEFLECTION, ETC.,
Steve Otto
MAY NEED TO BE ADJUSTED DUE TO SITE-SPECIFIC CONDITIONS. 4. HTCB TYPICALLY SHOULD BE PLACED UNDER THE FOLLOWING CONDITIONS: - AT THE SHOULDER BREAKPOINT (0.0 m LATERAL OFFSET FROM THE EDGE OF PAVEMENT).
For Executive Director, Technical Standards Branch
- THE OPTION OF TWO SEPARATE LONGITUDINAL RUNS OF HTCB SHOULD ALSO BE CONSIDERED WHERE THE MEDIAN WIDTH IS NARROW, DESIRABLE DEFLECTION SPACE IS GREATER THAN THE SHOULDER WIDTH, AND/OR GENERAL
Date: 17 February, 2012
RE-GRADING IS NOT AN OPTION, ETC. 5. NO ZONE AREA IN THE MEDIAN WHERE HTCB TYPICALLY MAY NOT BE INSTALLED.
APPENDI X B2
6. POSTS CAN BE PLACED IN SOCKETS IN CONCRETE FOUNDATIONS OR SOCKETS DRIVEN INTO THE GROUND DEPENDING ON THE SOIL CONDITION, MANUFACTURER'S SPECIFICATION AND FHWA APPROVALS. POSTS DRIVEN DIRECTLY INTO THE GROUND ARE NOT PERMITTED.
TYPICAL HIGH TENSION CABLE BARRIER MEDIAN INSTALLATION
7. THE DITCH MAY BE SUBJECT TO WEAK SOILS (OFTEN UNCOMPACTED), PERIODIC FLOODING AND/OR WET SOIL CONDITIONS. THE SOIL STRENGTH MUST BE TAKEN INTO ACCOUNT WHEN DESIGNING THE POST FOUNDATIONS AND
SLOPES STEEPER THAN 4(H):1(V)
END ANCHOR FOUNDATIONS. 8. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE NOTED.
Prepared By: GEC.
Checked By: PM
Scale: N.T.S.
Dwg No.:
RDG-B2.3
NOTES
1
2
1. HIGH TENSION CABLE BARRIERS (HTCB) ARE PROPRIETARY PRODUCTS AND THEREFORE MUST BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S AND/OR VENDOR'S SPECIFICATIONS. CABLE BARRIER PRODUCTS VARY SUBSTANTIALLY IN DETAILS, SPECIFICATION AND METHOD OF INSTALLATION, ETC. DESIGNERS SHOULD REVIEW THE FHWA (UNITED STATES FEDERAL HIGHWAY ADMINISTRATION) ELIGIBILITY LETTERS IN CONJUNCTION WITH THE MANUFACTURER AND/OR VENDOR'S PRODUCT DETAILS AND SPECIFICATIONS. 2. DESIGNERS SHALL REVIEW THE FHWA ELIGIBILITY LETTERS AND THE TEST DOCUMENTATION UPON WHICH THE LETTERS ARE BASED IN DETAIL. THIS INCLUDES THE SUMMARY RESULTS (E.G. TEST DEFLECTION), TEST SITE CONDITIONS (E.G. POST SPACING, SOIL DATA, ETC.), PRODUCT DETAILS PROVISIONS, ETC., UNDER WHICH THE PRODUCT WAS TESTED AND ACCEPTED. 3. FHWA ELIGIBILITY LETTERS ARE NORMALLY BASED ON THE HTCB SYSTEM BEING TESTED ON TANGENT IN A CONTROLLED ENVIRONMENT. THE SLOPE PLACEMENT, POST SPACING AND SPECIFIED MAXIMUM DEFLECTION, ETC., MAY NEED TO BE ADJUSTED DUE TO SITE-SPECIFIC CONDITIONS. 4. HTCB SYSTEMS CAN TYPICALLY BE PLACED DOWN THE SIDESLOPES IF THE SLOPES ARE 4H:1V OR FLATTER. THIS SLOPE REFERS TO THE SLOPE ON THE ROADSIDE BETWEEN THE SHOULDER BREAK POINT AND THE BARRIER SYSTEM (DIMENSION "X1"). THE AREA IMMEDIATELY BEHIND THE BARRIER SYSTEM MAY BE CONSTRUCTED AT STEEPER SLOPES DEPENDING ON THE STABILITY OF THE SOIL. 5. HTCB SYSTEMS MAY NOT BE PLACED DOWN THE SLOPE ON SIDESLOPES STEEPER THAN 4H:1V UNLESS THE SYSTEM HAS BEEN SUCCESSFULLY CRASH TESTED UNDER THESE CONDITIONS (WITH AN FHWA ELIGIBILITY LETTER). HTCB MAY BE PLACED AT THE EDGE OF PAVEMENT (EDGE OF SHOULDER ON UNPAVED ROADS) AS SHOWN IN THE TABLE. 6. A CONTINUATION OF THE FLATTER SLOPE BEHIND THE BARRIER, FOR A DISTANCE OF 0.0 METRES TO 0.6 METRES (DESIRABLE SHOULD BE CONSIDERED. THE DISTANCE BEHIND THE BARRIER SYSTEM MAY VARY DEPENDING ON THE EMBANKMENT SLOPE, POST FOUNDATION/DEPTH, SOIL/GEOTECHNICAL CONDITION, POST SPACING, EXPECTED IMPACT CONDITION, ETC. 7. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE NOTED. C L ROAD TRAVEL LANE
SHOULDER
"X1"
(WIDTH VARIES)
SIDESLOPE
0 TO 0.6 (DESIRABLE)
1
REFER TO NOTE 6 "HTCB" (3 OR 4 CABLES)
H V
2
STEEPER DROP OFF PERMITTED DEPENDING
EDGE OF PAVEMENT (SHOULDER BREAKPOINT)
ON SOIL CONDITIONS
4 3 2
NOTES 1 - 6, CROSS SECTION AND TABLE
HC 28 OCT 16
1
NOTE 6 AND CROSS SECTION
PM
4 APR 12
BY
DATE
No.
REVISIONS
Approved:
ROADSIDE
MAXIMUM DIMENSION (X1)
SIDESLOPE*
FROM THE OUTSIDE EDGE OF SHOULDER (m) *
6H:1V OR FLATTER
INFINITY
6H:1V > SIDELSOPES >
0.0 TO 1.2 OR
4H: 1V
GREATER THAN 6.0
STEEPER THAN 4H:1V
0.0
Steve Otto For Executive Director, Technical Standards Branch
Date: 17 February, 2012
2
TYPICAL HIGH TENSION CABLE BARRIER ROADSIDE INSTALLATION
*SUBJECT TO GEOTECHNICAL/SOIL CONDITIONS
Prepared By: GEC.
APPENDIX B2
Checked By: PM
Scale: N.T.S.
Dwg No.:
RDG-B2.4
H-APP-B2-6
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B3 WEAK POST BOX BEAM GUARDRAIL
APPENDIX B3
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B3
Alberta Transportation Roadside Design Guide
November 2012
Appendix B3 Weak Post Beam Guardrail TABLE OF CONTENTS Table Number
Title
Page Number
TEB 3.22
Median Box Beam Barrier Installation Detail Treatment of Median Hazard
H‐APP‐B3‐1
TEB 3.23
Median Box Beam Guardrail Rail and Splice Plate Detail
H‐APP‐B3‐2
TEB 3.24
Median Box Beam Guardrail Post Detail
H‐APP‐B3‐3
TEB 3.26
Median Box Beam Guardrail Installation Detail for End Treatment
H‐APP‐B3‐4
TEB 3.27 TEB 3.27A TEB 3.28 TEB 3.28A
Standard Box Beam Guardrail Detail of Splice Plate Used at End Treatment Median Box Beam Guardrail Detail of Splice Plate Used at End Treatment Standard Box Beam Guardrail Retainer Assembly and Track Welding Details Median Box Beam Guardrail Retainer Assembly and Track Welding Details
H‐APP‐B3‐5 H‐APP‐B3‐6 H‐APP‐B3‐7 H‐APP‐B3‐8
TEB 3.30
Median Box Beam Guardrail Expansion Joint Splice Detail
H‐APP‐B3‐9
TEB 3.33
Standard Box Beam Guardrail Post Detail
H‐APP‐B3‐10
TEB 3.34
Standard Box Beam Guardrail Bracket Assembly Detail
H‐APP‐B3‐11
TEB 3.35
Standard Box Beam Guardrail Rail and Splice Plate Detail
H‐APP‐B3‐12
TEB 3.36
Standard Box Beam Guardrail Bent Splice Plate Detail
H‐APP‐B3‐13
TEB 3.37
Standard Box Beam Guardrail Installation Detail for End Treatment
H‐APP‐B3‐14
TEB 3.39
Standard Box Beam Guardrail Assembly for 0.915m and 1.83m Post Spacing
H‐APP‐B3‐15
TEB 3.40
Standard Box Beam Guardrail Expansion Joint Splice Detail
H‐APP‐B3‐16
TEB 3.46
Standard Box Beam Guardrail Bend Detail for Approach Road Radii
H‐APP‐B3‐17
APPENDIX B3-i
TABLE OF CONTENTS
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS
APPENDIX B3-ii
195
195
76
4 - 24mm dia. holes
4 - 23.8x23.8mm square holes
28 24
28 24
Box Beam 6.35mm 16
Box Beam
76
Splice Plate Tack Weld
Splice Plate M20 nut welded to plate after galvanizing
M20 Sq. nut
Retainer Assembly
2.5*
28 * 21.25 *
4.75 *
16.7 5*
0.79
M20 Sq. nut
9.50 *
3.0X13.5mm Slot
21.25 * 31 *
Tolerance +- 0.24mm
30.75*
Traffic Operations Branch
DWG. No.
TEB 3.28
Date Revision Revision
DEC 20/92 __________ __________
RETAINER ASSEMBLY AND TRACK WELDING DETAILS A.D. Cherwenuk, Director
APPENDIX B3
H-APP-B3-7
195
14mm DIA HOLE
13
735
S75 x 8
125
1635
Ground Line
50
50
900mm min 50
600
6
6 x 200 x 600mm ground plate
50 200
All dimensions are in millimetres unless otherwise indicated.
DWG. No. Traffic Enigineering Section Roadway Engineering Branch
H-APP-B3-10
Date Revision Revision
TEB 3.33 _____________ DEC.17/92 June 95 __________
APPENDIX B3
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B3-18
APPENDIX B3
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B4 PRECAST F‐SHAPE AND “NJ” SHAPE CONCRETE BARRIERS
APPENDIX B4
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDX B4
Alberta Infrastructure and Transportation Roadside Design Guide
November 2012
Appendix B4 Precast F-Shape and "NJ" Shape Concrete Barriers TABLE OF CONTENTS Table Number
Title
Page Number
CB6‐4.2M16
Precast F‐Shape Barrier NCHRP 350 Test Level 3
H‐APP‐B4‐1
CB6‐4.3M1A
Reinforced Concrete Median Barrier NJ Shape
H‐APP‐B4‐2
CB6‐4.3M12
Precast Concrete Barrier NJ Shape
H‐APP‐B4‐3
APPENDIX B4-i
TABLE OF CONTENTS
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS
APPENDIX B4-ii
H-APP-B4-2
APPENDIX B4
R O F
T E R
RO
T FI
O
Y L N
Prepared By: N.N.
Checked By: B.K
Effective Date: 1997
Scale: N.T.S.
Dwg No.:
CB6-4.3M1A
APPENDIX B4
H-APP-B4-3
R O F
T E R
RO
T FI
O
Y L N
Prepared By: N.N.
Checked By: B.K
Date: MAY, 1985
Scale: N.T.S.
Dwg No.:
CB6-4.3M12
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B4-4
APPENDIX B4
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B5 THRIE BEAM GUARDRAIL
APPENDIX B5
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B5
Alberta Transportation Roadside Design Guide
March 2016
Appendix B5 Thrie Beam Guardrail TABLE OF CONTENTS Dwg. No.
TEB 3.15a TEB 3.16a TEB 3.17a TEB 3.18a
Title
Page Number
Typical W-Beam Strong Post or Modified Thrie Beam Guardrail Placement Roadside Hazards (Two and Four Lane Highways) Typical Strong Post W-Beam or Modified Thrie Beam Guardrail Placement at Bridge Approaches (Two-Lane Highway) Typical Strong Post W-Beam or Modified Thrie Beam Guardrail Placement at Bridge Approaches (Four-Lane Divided Highway) Typical Strong Post W-Beam or Modified Thrie Beam Guardrail Placement for Median Hazards
H-APP-B5-1 H-APP-B5-2 H-APP-B5-3 H-APP-B5-5
TEB 3.60-1
Bullnose Guardrail System Protection of Piers in Medians
H-APP-B5-7
TEB 3.60-2
Bullnose Guardrail System Protection of Piers in Medians
H-APP-B5-8
TEB 3.60-3
Bullnose Guardrail System Cable Anchor
H-APP-B5-9
TEB 3.60-4
Bullnose Guardrail System Posts & Blocks
H-APP-B5-10
TEB 3.60-5
Bullnose Guardrail System Rail Section 1
H-APP-B5-11
TEB 3.60-6
Bullnose Guardrail System Rail Section 2
H-APP-B5-12
TEB 3.60-7
Bullnose Guardrail System Rail Section 3
H-APP-B5-13
TEB 3.60-8
Bullnose Guardrail System Plates and Cable Assembly
H-APP-B5-14
TEB 3.60-9
Bullnose Guardrail System Thrie Beam and Cable Length
H-APP-B5-15
TEB 3.70
Modified Thrie Beam Guardrail
H-APP-B5-17
RDG-B5.1 RDG-B5.2 RDG-B5.3 RDG-B5.4 RDG-B5.5
Modified Thrie Beam Cable Anchor Terminal with Wing End (Exit End Treatment for Divided Highways) Bullnose Guardrail System Standard Thrie Beam Cable Anchor Terminal with Wing End (Exit End Treatment for Divided Highways) Hardware Details for W-Beam and Thrie Beam Guardrail Cable Anchor Terminal Foundation Tube and Foundation Tube Soil Plate Details for W-Beam and Thrie Beam Cable Anchor Terminal TL-3 Transition from Modified Thrie Beam Guardrail to W-Beam Strong Post Guardrail
H-APP-B5-18 H-APP-B5-19 H-APP-B5-20 H-APP-B5-21 H-APP-B5-23
RDG-B5.6
Thrie Beam Bullnose Guardrail General Layouts
H-APP-B5-24
RDG-B5.7
Thrie Beam Bullnose Guardrail General Layouts
H-APP-B5-25
RDG-B5.8
Thrie Beam Bullnose Guardrail Detailed Plans
H-APP-B5-26
RDG-B5.9
Thrie Beam Bullnose Guardrail Detailed Plans
H-APP-B5-27
RDG-B5.10
W-Beam Strong Post to Modified Thrie Beam Guardrail Transition at Roadside Structure
H-APP-B5-28
APPENDIX B5-i
TABLE OF CONTENTS
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS
APPENDIX B5-ii
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
_____________________________________________________________________________________________________________________________________________________
THIS PAGE LEFT INTENTIONALLY BLANK
H-APP-B5-4
APPENDIX B5
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B5-6
APPENDIX B5
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
_____________________________________________________________________________________________________________________________________________________
THIS PAGE LEFT INTENTIONALLY BLANK
H-APP-B5-16
APPENDIX B5
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B5-22
APPENDIX B5
C L POST CENTRE FOR LENGTH OF HAZARD
C L POST
C L POST
C L POST 1905
1905
953
POSTS AT 1905 ON CENTRE (LENGTH OF NEED OF W-BEAM STRONG POST
HAZARD
SIDE SLOPE TRANSITION (600 MIN OFFSET FROM BACK FACE OF MODIFIED THRIE BEAM POSTS)
10H ( MI N):1V
= 600 MIN
AS DETERMINED BY THE CONSULTANT) SI DE SLOPE
AS DETERMINED BY THE CONSULTANT
C L POST 953
SI TE SPECI FI C
POSITION POSTS AT 1905 ON
HAZARD
C L POST 4 SPACES AT 1 905 = 7 620
LENGTH OF GUARDRAIL
W - BEAM GUARDRAIL
1
THRIE BEAM GUARDRAIL EDGE OF FINISHED PAVEMENT
PLAN
1
WOOD OR STEEL POSTS MAY BE USED IN THIS TRANSITION ZONE
WOOD, STEEL OR PLASTIC POSTS MAY BE USED
(SEE NOTE 10) C L POST
ROADSIDE
C L POST
STRUCTURE
C L POST
MODIFIED THRIE BEAM GUARDRAIL
TRANSITION
HEIGHT TRANSITIONING FROM 550 TO 610
(SEE DRAWING RDG-B5.5)
(SEE NOTE 11)
C L POST 1905
C L POST W - BEAM STRONG POST GUARDRAIL
1905
(SEE DRAWING RDG-B5.5 FOR DETAILS) 1905 (TYP)
C L POST 1905 (TYP)
1905 (TYP)
A HAZARD
HAZARD
-
TRAFFIC FLOW
1
B
1 LAYER OF 2.7 THICK
1 LAYER 2.7 THICK
THRIE BEAM GUARDRAIL
SPLICE
BACK-UP PLATE
(TYP)
(TYP)
(TYP)
-
W - THRIE BEAM TRANSITION SECTION
W - BEAM GUARDRAIL
C THRIE BEAM L 550
610
C L W-BEAM
TOP OF FINISHED ROADWAY
610
550
AT EDGE OF PAVEMENT
1
ELEVATION
(SEE NOTE 8)
M360 x 25.6 STEEL OFFSET BLOCK REFLECTIVE TAB
152 x 203 x 360 LONG
(SEE NOTE 7)
TREATED TIMBER
180
25
REFLECTIVE TAB
SPACER
1
600 MIN (TYP)
EDGE OF SHOULDER
NOTES 7 AND 8 REVISED. NOTES 10 AND 11
TIMBER POST
1. FOR GENERAL LAYOUT REFER TO TEB DRAWINGS 3.15a AND 3.18.
(SEE NOTE 10)
2. WHERE GUARDRAIL IS ADJACENT TO CURB, HEIGHT OF RAIL SHALL BE MEASURED AS FOLLOWS: a.VERTICALLY AT FACE OF GUARDRAIL WHEN FACE OF GUARDRAIL IS MORE THAN
EDGE OF SHOULDER
ADDED. POST REMOVED FROM PLAN AND 1
ELEVATION
No.
REVISIONS
PM
11 MAR 2016
BY
DATE
300 BEYOND GUTTER LINE. 10 (MIN) : 1 SIDE SLOPE
SITE SPECIFIC SIDE SLOPE
Approved:
b.VERTICALLY AT GUTTER LINE WHEN FACE OF GUARDRAIL IS 300 OR LESS BEYOND SITE SPECIFIC SIDE SLOPE
GUTTER LINE. 3. POSTS SHALL BE SET BY INSTRUMENT FOR ALIGNMENT AND GRADE, WITH TOP
1830
10 (MIN) : 1 SIDE SLOPE
1
TREATED W - BEAM GUARDRAIL 550
THRIE BEAM GUARDRAIL WITH BACK-UP PLATE
2
NOTES:
152 x 203
730
610
890
W150 x 13.5 STEEL POST
PARALLEL TO PAVEMENT GRADE.
Allan Kwan
4. THE ACCEPTABLE TOLERANCE FOR HEIGHT OF GUARDRAIL AT TIME OF CONSTRUCTION OR MAINTENANCE SHALL BE IN ACCORDANCE WITH THE MOST
1170
1100
RECENT SPECIFICATIONS.
Executive Director, Technical Standards Branch
5. LAP ALL JOINTS IN THE DIRECTION OF TRAFFIC FLOW.
INFRASTRUCTURE AND TRANSPORTATION
6. ALL FITTINGS AND HARDWARE REQUIRED SHALL BE GALVANIZED. 7. FASTEN TO TOP OF EVERY SIXTH GUARDRAIL STRONG POST SPACER BY MECHANICAL
Date:
NOVEMBER, 2007
MEANS SUCH AS NAILING OR STAPLING. ADHESIVES ALONE WILL NOT BE ACCEPTED. 8. FASTEN TO TOP OF EVERY SIXTH GUARDRAIL STEEL OFFSET BLOCK WITH APPROVED ADHESIVE.
W-BEAM STRONG POST
9. THIS TRANSITION SATISFIES NCHRP REPORT 350 REQUIREMENTS FOR TEST LEVEL 3 (TL3). 10.TRANSITION ZONE CAN BE WOOD OR STEEL POST WITH WOOD SPACER BLOCK.
SECTION A
SECTION B
( FOR DETAILS SEE TEB DRAWING 3.70)
(FOR DETAILS SEE TEB DRAWING 3.09 )
REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS. 11.TYPICAL STRONG POST SYSTEM CAN BE WOOD, STEEL, OR PLASTIC POST WITH WOOD SPACER BLOCK. REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS.
TO MODIFIED THRIE BEAM GUARDRAIL TRANSITION AT ROADSIDE STRUCTURE
POST DETAILS ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
H-APP-B5-28
Prepared
Checked
Scale:
By: MO
By: WS
N.T.S.
Dwg No.:
RDG-B5.10 APPENDIX B5
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B6 CAST‐IN‐PLACE OR EXTRUDED F‐SHAPE CONCRETE BARRIER AND SINGLE SLOPE CONCRETE BARRIER
APPENDIX B6
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B6
Alberta Transportation Roadside Design Guide
March 2016
Appendix B6 Cast-In Place Or Extruded F-Shape Concrete Barrier and Single Slope Concrete Barrier TABLE OF CONTENTS Drw. No.
Drawing Title
Page Number
CB6-4.3M3
Slip-Formed Median Barrier F-shape
H-APP-B6-1
CB6-4.3M3A
Slip-formed Concrete Barrier Half F-Shape
H-APP-B6-2
4.3 M4 4.3 M5 RDG-B6.1 RDG-B6.3 RDG-B6.4 RDG-B6.5 RDG-B6.6 RDG-B6.7 RDG-B6.8 RDG-B6.9 RDG-B6.10 RDG-B6.11 RDG-B6.12 RDG-B6.13 RDG-B6.14 RDG-B6.15
APPENDIX B6-i
Transition End Section for Reinforced Concrete Median Barrier Curb FShape Isometric View of Transition End Section for Reinforced Concrete Median Barrier Curb
H-APP-B6-3 H-APP-B6-4
TL-4 Standard Single Slope Concrete Barrier Details
H-APP-B6-5
TL-4 Single Slope Concrete Median Barrier Transition Around Existing/New Bridge Pier – Sheet 1 of 2 TL-4 Single Slope Concrete Median Barrier Transition Around Existing Bridge Pier – Sheet 2 of 2 TL-4 Single Slope Concrete Median Barrier Transition Around New Bridge Pier – Sheet 1 of 3 TL-4 Single Slope Concrete Median Barrier Transition Around New Bridge Pier – Sheet 2 of 3 TL-4 Single Slope Concrete Median Barrier Transition Around Existing/New Bridge Pier – Sheet 3 of 3 TL-2 and TL-3 Concrete Median Barrier Termination TRACC Crash Cushion System (Bidirectional) TL-2 and TL-3 Concrete Median Barrier Termination Quadguard Crash Cushion System (Bidirectional) TL-2 and TL-3 Unidirectional Quadguard Crash Cushion System for Wide Median Hazards Quadguard and TRACC Crash Cushion Systems Concrete Pad Foundation Transition of TL-4 Single Slope Concrete Barrier to W-Beam Median Guardrail – Sheet 1 of 2 Transition of TL-4 Single Slope Concrete Barrier to W-Beam Median Guardrail – Sheet 2 of 2 TL-4 Single Slope Concrete Barrier Transition to PL-2 Standard Bridge Concrete Barrier Transition of W-Beam Guardrail to TL-4 Single Slope Concrete Roadside Barrier
H-APP-B6-7 H-APP-B6-8 H-APP-B6-9 H-APP-B6-10 H-APP-B6-11 H-APP-B6-12 H-APP-B6-13 H-APP-B6-14 H-APP-B6-15 H-APP-B6-16 H-APP-B6-17 H-APP-B6-18 H-APP-B6-19
TABLE OF CONTENTS
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS
APPENDIX B6-ii
300
R 25
810 BASIC
125 R 225 25 M REINFORCING DOWELS
180
150
150
75 200 100 150
50 50
ALLOWANCE FOR FUTURE OVERLAY MIN. KEY DEPTH
670
125
ASPHALTIC CONCRETE PAVEMENT
150
125
A SECTION 670 2-800mm 15M REINFORCING DOWEL 150 25 M REINFORCING DOWELS
A
A ROUGHENED END FACE 900
CONSTRUCTION JOINT DETAIL
150
450
16/06/05 08/04 12/03 10/03
GENERAL NOTES
PLAN VIEW
1. All concrete shall meet the requirements of the Specifications for Bridge Construction Section 4 Modified, Class C, except that slump shall be ** +-1*mm and minimum cement content shall be 335 kg/m3. 2. All reinforcement dowels shall be epoxy coated. 3. All exposed concrete shall be finished to a smooth, uniform and closed texture. 4. Exposed surfaces shall have an approved sealer applied in accordance with manufacturer's recommendations. 5. No longitudinal reinforcement required.
Approved: Original signed by Allan Kwan Executive Director, Technical Standards Branch Date:
APRIL, 1986
INFRASTRUCTURE AND TRANSPORTATION
SLIP-FORMED MEDIAN BARRIER F-SHAPE
6. Tooled or saw cut all around every 3m (min. 50mm deep x 3-6mm wide). 7. No joint sealer required.
APPENDIX B6
Prepared By: M.T
Checked By: B.K
Scale: N.T.S.
Dwg No.:
CB6-4.3M3
H-APP-B6-1
300
300 MINIMUM 2% MIN.
R 25 2:1
TRAVEL LANE
810 BASIC
SIDE
MI
NIM UM
EARTH FILL COMPACTED TO 95% OF STANDARD COMPACTION (MOISTURE-DENSITY RELATION)
125 R 225 180
25 M REINFORCING DOWELS
75 50 50
ALLOWANCE FOR FUTURE OVERLAY
150
200 ASPHALTIC CONCRETE PAVEMENT
100 100 485
100 125
MIN. KEY DEPTH
150
A SECTION
125
485
100
450
2-800mm 15M REINFORCING DOWELS
25 M REINFORCING DOWELS
899 100
A
ROUGHENED END FACE
CONSTRUCTION JOINT DETAIL
A
All dimensions in millimetres unless otherwise noted.
GENERAL NOTES
PLAN VIEW
06/16/05
1. All concrete shall meet the requirements of the Specifications for Bridge Construction Section 4,Modified Class C, except that slump shall be 20+- 10mm 3 and minimum cement content shall be 335 kg/m .
Approved: Original signed by Allan Kwan
2. All reinforcement dowels shall be epoxy coated. 3. All exposed concrete shall be finished to a smooth, uniform and closed texture. 4. Exposed surfaces shall have an approved sealer applied in accordance with manufacturer's recommendations.
Executive Director, Technical Standards Branch Date:
SEPTEMBER, 2004
5. Half F barrier is for use with earth fill as shown. 6. No longitudinal reinforcement required. 7. Tooled or saw cut all around every 3m (min. 50mm deep x 3-6mm wide).
SLIP-FORMED CONCRETE BARRIER HALF F-SHAPE
8. No joint sealer required. 9. Earth fill shall be suitable material as indicated under 2.3.2 of the Standard Specification for Highway Construction.
H-APP-B6-2
Prepared By: M.T
Checked By: B.K
Scale: N.T.S.
Dwg No.:
CB6-4.3M3A
APPENDIX B6
APPENDIX B6
H-APP-B6-3
H-APP-B6-4
APPENDIX B6
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
H-APP-B6-6
APPENDIX B6
C L POST
C L POST
C L POST
1905
C L POST
1905
C L POST
3 SPACES AT 953 = 2 859
5 SPACES AT 476 = 2 380
TRAFFIC FLOW
300
600
SAWCUT CONTRACTION JOINT
1
1
PLAN
1
WOOD, STEEL OR PLASTIC POSTS MAY BE USED
WOOD OR STEEL POSTS MAY BE USED IN THIS TRANSITION ZONE
(SEE NOTE 7)
(SEE NOTE 6)
W-BEAM STRONG POST MEDIAN GUARDRAIL
C L POST
TRAFFIC FLOW
C L POST
W-BEAM STRONG POST MEDIAN GUARDRAIL
C L POST
TRANSITION
STANDARD THRIE BEAM MEDIAN GUARDRAIL
C L POST
SINGLE SLOPE CONCRETE MEDIAN BARRIER
OR FOR TRANSITION TO
A W - BEAM
-
GUARDRAIL
2.7 THICK W-BEAM
2.7 THICK
B
W-THRIE BEAM
-
260 2 LAYERS OF 2.7 THICK THRIE BEAM GUARDRAIL
TRANSITION SECTION
800
3 000 (TRANSITION FROM VERTICAL TO SINGLE SLOPE)
95
CAT-350 TERMINAL SEE RDG-B1.7
BACK-UP PLATE 3.4 THICK THRIE BEAM TERMINAL CONNECTOR C THRIE BEAM L 550
550
SEE DETAIL 1
900
C W - BEAM L
RDG-B6.13 TOP OF FINISHED ROADWAY AT EDGE OF PAVEMENT
1 SEE NOTE 4
460
340
3 000
ELEVATION
2 - PL 480 x 100 x 24
2 LAYERS OF
152 x 203 x 360 LONG
ADDITIONAL SPACER
THRIE BEAM
TREATED TIMBER
PLATE
GUARDRAIL
260
1
1.
LAP GUARDRAIL SECTIONS IN THE DIRECTION OF TRAFFIC FLOW.
2.
ALL FITTINGS AND HARDWARE SHALL BE GALVANIZED.
2 - 16 DIA A307
3.
LINE AND ELEVATION OF BARRIER SHALL BE SET BY INSTRUMENT.
GUARDRAIL BOLTS
4.
ACP OR GRANULAR BASE COURSE MAY BE PROVIDED AROUND GUARDRAIL
(TYP EACH SIDE)
750
W - BEAM GUARDRAIL 550
730
110
SPACER
NOTES:
POSTS AS PER SITE SPECIFIC REQUIREMENTS. 5.
THIS TRANSITION MAY BE CONSIDERED TO SATISFY NCHRP REPORT 350 REQUIREMENTS FOR TEST LEVEL 4 (TL4)
2 - 16 DIA A307 BOLTS W 200 x 22
C/W NUTS AND
THRIE BEAM SPACER
WASHERS (TYP EACH SIDE)
2
6.
TRANSITION ZONE CAN BE WOOD OR STEEL POST WITH WOOD SPACER BLOCK.
7.
TYPICAL STRONG POST SYSTEM CAN BE WOOD, STEEL, OR PLASTIC POST WITH WOOD
1 SPACER BLOCK. REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS.
PLAN AND ELEVATION
No.
REVISIONS
HC
11 MAR 2016
BY
DATE
Approved:
152 x 203 TREATED TIMBER POST
30
Allan Kwan
INFRASTRUCTURE AND
168
Executive Director, Technical Standards Branch
TRANSPORTATION 20 DIA HOLE
194
260 110
SECTION B
480
542
110
W 150 x 14 POST
SECTION A
C L W 200 x 22 30
62
(SEE NOTE 6)
180
1
1220
1100
1970
1830
NOTE 6 AND 7 ADDED. POST REMOVED FROM
REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS.
Date: NOVEMBER, 2007
(TYP)
W 200 x 22
TRANSITION OF TL-4
(SEE TEB DRAWING 3.09 FOR DETAILS)
THRIE BEAM SPACER DETAIL POST DETAILS
SINGLE SLOPE CONCRETE BARRIER TO W-BEAM MEDIAN GUARDRAIL SHEET 1 OF 2
ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
H-APP-B6-16
Prepared
Checked
Scale:
By:MO
By:WS
N.T.S.
Dwg No.:
RDG-B6.12 APPENDIX B6
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
_____________________________________________________________________________________________________________________________________________________
THIS PAGE LEFT INTENTIONALLY BLANK
H-APP-B6-20
APPENDIX B6
Alberta Infrastructure and Transportation Roadside Design Guide
November 2007
APPENDIX B7 MISCELLANEOUS DRAWINGS
APPENDIX B7
COVER PAGE
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
COVER PAGE
APPENDIX B7
Alberta Transportation Roadside Design Guide
March 2016
Appendix B7 Miscellaneous Drawings TABLE OF CONTENTS Dwg. No.
Drawing Title
Page Number
TEB 3.19
Sand Barrel Cushion System
H-APP-B7-1
TEB 3.51
Guide Post Delineation for Guardrail
H-APP-B7-3
TEB 1.81
Typical Breakaway Wood Post
H-APP-B7-4
RDG-B7.1 RDG-B7.2 RDG-B7.3 RDG-B7.4 RDG-B7.5
APPENDIX B7-i
TL-3 W-Beam Guardrail Placement at Minor Structures and Box Culverts TL-4 Single Slope Concrete Barrier Transition at Median Light Standard – Sheet 1 of 2 TL-4 Single Slope Concrete Barrier Transition at Median Light Standard – Sheet 2 of 2 Placement and Protection of Overhead Sign Supports for Divided Roads – Sheet 1 of 2 Placement and Protection of Overhead Sign Supports for Divided Roads – Sheet 2 of 2
H-APP-B7-5 H-APP-B7-6 H-APP-B7-7 H-APP-B7-8 H-APP-B7-9
TABLE OF CONTENTS
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
THIS PAGE INTENTIONALLY LEFT BLANK
TABLE OF CONTENTS
APPENDIX B7-ii
Alberta Infrastructure and Transportation November 2007
Roadside Design Guide
_____________________________________________________________________________________________________________________________________________________
THIS PAGE LEFT INTENTIONALLY BLANK
H-APP-B7-2
APPENDIX B7
H-APP-B7-4
APPENDIX B7
A
B
C
-
-
-
TRAFFIC FLOW C L POST
C L POST STANDARD W-BEAM
C L POST
11430 NESTED 2.7 THICK W-BEAM
STRONG POST GUARDRAIL
C L POST STANDARD W-BEAM
11430 NESTED 2.7 THICK W-BEAM
TWO NESTED 2.7 THICK W-BEAM RAIL ELEMENTS
(6 - 3810 SECTIONS OR 2 - 7620 AND 2 - 3810 SECTIONS)
(6 - 3810 SECTIONS OR 2 - 7620 AND 2 - 3810 SECTIONS) 6 SPACES AT 1905
STRONG POST GUARDRAIL
6 SPACES AT 1905
POST SPACING 7620, 5715 OR 3810 (SEE NOTE 1)
WOOD, STEEL, ORPLASTIC POSTS MAY BE USED
WOOD, STEEL OR PLASTIC POSTS MAY BE USED
(SEE NOTE 8) 1
(SEE NOTE 8) 1
STANDARD W-BEAM STRONG POSTS
C L POST
C L POST
7300 OR LESS
CRT POSTS
C L POST
CRT POSTS
WITH TWO BLOCKOUTS
C POST L
STANDARD W-BEAM STRONG POSTS
WITH TWO BLOCKOUTS INTERMEDIATE LAP
ENDING LAP
2
3
4
WITH POST
5
BEGINNING LAP
6
550
1
C LW-BEAM
TOP OF FINISHED ROADWAY
PI PE CULVERT
SLAB OR
HEADW ALL
CURB OR CULVERT
AT EDGE OF PAVEMENT
ELEVATION C POST 3 L
C POST 4 L
CRT WOOD POST WITH BLOCKOUTS (TYP)
1
NOTES: 1.
7620 RAIL LENGTHS MAY BE USED TO ELIMINATE THE
2.
POST 1 THRU 6 ARE CRT POSTS WITH TWO BLOCKOUTS.
3.
INSTALL THE BACK FACE OF THE NESTED GUARDRAIL A MINIMUM
4.
MAINTAIN FLAT SIDE SLOPE GRATING AT POST LOCATIONS.
INTERMEDIATE LAP WITHOUT A POST. DO NOT PLACE A LAP
8 - M16 X 50 BUTTON HEAD
WITHOUT A POST UNLESS NEEDED DUE TO LENGTH OF GAP.
BOLTS AND RECESS NUTS NESTED W-BEAM
(TYP.)
RAIL ELEMENT
NESTED W-BEAM
(SEE SECTION B FOR DETAILS)
NESTED W-BEAM
RAIL ELEMENT
RAIL ELEMENT
OF 1500 FROM THE FACE OF THE CURB-LIKE HEADWALL.
TRAFFIC FLOW
5.
LAP ALL RAIL SECTIONS IN THE DIRECTION OF TRAFFIC FLOW.
6.
ALL FITTINGS AND HARDWARE SHALL BE GALVANIZED.
7.
THIS DESIGN MEETS NCHRP REPORT 350 EVALUATION CRITERIA FOR TL-3
8. TYPICAL STRONG POST SYSTEM CAN BE WOOD, STEEL OR PLASTIC POST WITH
ENDING LAP
WOOD SPACER BLOCK. REFER TO STANDARD DRAWING TEB 3.01 FOR POST DETAILS.
BEGINNING LAP
INTERMEDIATE LAP WITHOUT POST
1500 (MIN)
152 x 203 x 360 LONG NESTED W-BEAM
NESTED W-BEAM
GUARDRAIL
152 x 203 x 360 LONG
TREATED TIMBER
NESTED W-BEAM
TREATED TIMBER
SPACERS
GUARDRAIL
SPACER
GUARDRAIL
2 152x203 TREATED
152 x 203 TREATED TIMBER POST
HEADWALL
(SEE NOTE 8)
NOTE 8 ADDED
1
TIMBER POST 730
550
730
OR CURB
1
No.
REVISIONS
550
550
CULVERT
EDGE OF SHOULDER
HOLE
11 MAR 2016
BY
DATE
Approved:
90 DIA BREAKAWAY EDGE OF SHOULDER
HC
10 (MIN) : 1 SIDE SLOPE
(SEE NOTE 4)
400
Allan Kwan
Executive Director, Technical Standards Branch
INFRASTRUCTURE AND TRANSPORTATION
1100
1100
90 DIA BREAKAWAY HOLE
Date:
NOVEMBER, 2007
TL-3 W-BEAM GUARDRAIL PLACEMENT SECTION A (SEE NOTE 3)
SECTION B CONTROLLED RELEASE TERMINAL (CRT) POST (SEE NOTE 2)
AND BOX CULVERTS
STANDARD W-BEAM STRONG POST (FOR DETAILS SEE TEB DRAWING 3.09)
ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE INDICATED.
APPENDIX B7
AT MINOR STRUCTURES
SECTION C
Prepared
Checked
Scale:
By:MO
By: WS
N.T.S.
Dwg No.:
RDG-B7.1 H-APP-B7-5