Cold & Refrigerated Environments Brochure

46 downloads 5961 Views 3MB Size Report
To lower overall facility utility costs, Cooper Lighting features a broad offering of energy ... Accord luminaires provide soft, even ... lamp and ballasts to ..... Installation into a cold .... (10)Must be listed in the order shown and separated by a dash. ..... 226. $5.86. 28. HB-432-CL-UNV-EB81/PLUS-NUA. 4. 3100. 94%. 70 %. 1.15.
F L U O R E S C E N T H I G H B AY S PULSE START METAL HALIDE HIGH BAYS F L U O R E S C E N T L O W B AY S COMPLEX ENVIRONMENT

Cold & Refrigerated Environments Industrial Industrial Lighting LightingEnergy EnergySolutions Solutions

The Opportunity

Cold storage facilities can serve as mixed use environments with the capability to support such functions as warehouse, assembly and offices. To lower overall facility utility costs, Cooper Lighting features a broad offering of energy efficient lighting fixtures for -20°F (-29°C), as well as, general ambient temperatures. & Parking 1 Area Comprehensive offering of area and site lighting, including the Tribute, who’s rugged die-cast construction and userfriendly features, coupled with Pulse Start Metal Halide source, provide an energy efficient outdoor luminaire.

2 3

Manufacturing & Assembly The industry-leading fluorescent high bay, HB & 2HB series, features specification grade full body housing for structural integrity and optimal performance with two optical distributions.

Bay 4 Arctic 5 The Arctic Bay’s

Dry Storage Areas & Aisles

5 Aisle 6 The Micro-Bay

enclosed full body housing and sealed & gasketed door frame provide optimal lamp operation – 60% rated light output down to -20°F (-29°C).

I5 & I8 series narrow 11" specification grade body with two optical distributions and shielding options are ideal aesthetic upgrades for industrial applications.

series offers unprecedented light levels and energy savings from a compact luminaire perfect for aisles with higher mounting heights.

Dock & Loading Bays Energy efficient compact fluorescent Docklights consume up to 80% less energy than traditional incandescent.

1 1

& Security 7 Outdoor Full line of wall pack and floodlight security lighting equipped with energy efficient lamp sources.

1

& General Office 8 8 Private Accord luminaires provide soft, even distribution with shallow 3" depth in T5, T5HO and T8 configurations available with step dimming or occupancy sensors for additional savings and are an ideal retrofit for 3 and 4 lamp troffer and parabolic installations.

Entrance and Eaves Energy efficient Vaportite fixture featuring T8 and T5 lamps ideal for entrance areas and freezer environments down to -20°F (-29°C).

9

Break Rooms, Reception Areas & Corridors High efficiency T8 fluorescent recessed and surface luminaires use high performance lamp and ballasts to balance light output and energy savings.

Safety 10 Life Full line of energy efficient UL Listed and NFPA 101 rated life safety products for cold temperatures as low as -20°F (-29°C) and complex environments where electrical power is unavailable.

In today’s competitive environment, lower costs, higher productivity and increased quality are requirements for survival. While lighting is a necessity, high performance lighting can be a competitive weapon that can allow you to dramatically reduce energy costs, improve worker productivity and provide a safer working environment for your employees. From the parking lot and offices to the freezers, warehouses and back docks, Cooper lighting’s comprehensive approach to cold and refrigerated environments provides the products, tools and support you need to maximize efficiency for your facility and provide you with the competitive edge.

Index The Opportunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 1-6 Cooper Lighting is a proud member of the International Association of Refrigerated Warehouses.

Product Index ARCTIC BAY AB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 7-10 HID High Bays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 11-14 F-Bay HB/2HB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 15-18 Hosedown HBHD Series . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 19-20 Vaportite VT3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 21-24 MICRO-BAY MB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 25-26 Lamp Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 27 Emergency Options Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 27 F-Bay Mounting Accessories Matrix . . . . . . . . . . . . . . . . . . . . .pg. 27 Packaging Options Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 27 HB/2HB Lens, Door Frames and Wireguards . . . . . . . . . . . . . .pg. 28 Occupancy Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 29 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 30 Mounting Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 31-32 Programs & Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 33

2

Energy Savings Comparison in 0°F (-18°C) Environment

Reducing Energy Consumption Lighting represents one of the largest operating costs in a refrigerated environment; second only to refrigeration. Advancements in lighting technology for colder environments provide a means to reduce energy consumption up to 50% providing a simple payback in as little as two years.

500

455

400

Fluorescent technology offers more efficient lighting systems for ambient environments down to -20°F (-29°C). Fluorescent lighting system upgrades provide longer useful illumination, control capability, and better quality of light than traditional lighting systems for cold and refrigerated environments.

300 200

209

100 0

400 Watt MH

The Metalux Arctic Bay can reduce energy usage over 50% in freezer applications down to -20°F (-29°C).

AB-454T5

kWH

$56.16 $74.88 $93.60 $112.32

$0.06 $0.08 $0.10 $0.12

Annual Energy Savings

(based on 4000 hrs.)

Thermal Performance Cooper Lighting thermally tested each configuration to determine the optimal luminaire operating temperature range. When specifying luminaires use the lowest temperature the luminaire will be exposed to during operating hours. However, facility temperatures fluctuate and luminaires exposed to temperatures less than stated are not recommended. Freezer Temperature Ranges To maximize energy efficiency, some facilities will operate chillers only during offpeak hours. in this case the facility will chill the space -40°F (-40°C) to maintain the targeted temperature during operating hours. Fluorescent luminaires exposed to -40°F (-40°C) temperatures are not recommended. Energy efficient HID sources may be a better alternative.

40 ft. 35 ft. @ -40°F (-40°C)

30 ft.

20 ft.

10 ft.

20 ft. @ -20°F (-29°C)

10 ft. @ -10°F (-23°C)

Reduced Heat Contribution Lighting systems are a source of heat. Reducing the heat contribution of a lighting system will lower the cooling costs of the facilities refrigeration system. The ASHRAE Handbook provides allowance factors to calculate the heat gain from different light sources. HID source factors are more than 20% higher than linear fluorescent. However, actual savings are dependent on the lighting system and building configuration. Computer simulation tools are available (supplied by others) to assist in making an estimation.

Cooper Lighting’s 3 lamp T8 VT3 maintains 97% of light output in -15°F environments. The VT3 is an ideal solution for lower mounting height freezer applications.

3

Lower Maintenance Costs As a total system solution, T5 and T8 fluorescent systems provide more light output over their rated life up to twice as long as HID or outdated T12 fluorescent systems. Cooper Lighting’s fluorescent systems feature multiple lamps, so if a lamp burns out, the others stay lit. Fluorescent lighting systems with extended rated lamp life and multiple lamp configurations offer a safe operating environment and an opportunity to dramatically reduce maintenance expenditures. Lamp Life & Lumen Maintenance 400 Watt High Bay T5 HO 6-Lamp LIGHT OUTPUT

T8 HO Ballast 6-Lamp T5 HO 4-Lamp End of Lamp Life

The Metalux F-Bay can reduce maintenance intervals by up to 50%.

Initial

5000

10000

15000

20000

25000

30000

35000

HOURS

Controlling Energy Consumption Fluorescent systems offer instant on/off capabilities that, when utilized with occupancy controls, can help to reduce energy consumption. Colder ambient environments can affect warm up and restrike times. Refer to Cooper Lighting’s control recommendations throughout the product selection guide to optimize fixture performance.

The Micro-Bay can provide up to 75% energy savings over traditional HID systems when used with occupancy sensors.

Quality of Visible Light Our eyes use both rods and cones to see light. The rods are more sensitive to blue light (scotopic vision) and cones to yellow light (photopic vision). A traditional light meter measures only photopic lumens, which are the stated lumens referenced in lamp catalogs. The S/P Ratio acts as an adjustment to the existing photopic measurement by multiplying the standard lumens of a source with the S/P ratio or a factor thereof to replicate how our eyes perceive brightness. As a result, an environment illuminated with warmer light sources, such as high pressure sodium, may appear darker than an environment illuminated with cooler light sources, like high CCT fluorescent lamps. S/P Comparison of Fluorescent vs. HID 77°F (25°C)

LUMEN OUTPUT

50000

Initial System Lumens

25000

S/P Adjusted Initial Lumens

While an increasing number of lighting designers are endorsing the use of S/P ratios, this has not yet been endorsed by the Illuminating Engineering Society (IES). Cooper Lighting provides S/P adjusted lumen values throughout the product specification sections as reference information only and maintains no formal position on its application. Always test proposed products to validate results to your expectations.

0 6L 54W T5HO

400W HPS

4

Environmentally Friendly Cooper Lighting fluorescent luminaires are environmentally friendly. Housings and reflector assemblies are manufactured of recyclable steel and aluminum substrates. Corrugated packaging is both recyclable and optimized in design to reduce waste on the job site. The use of low mercury fluorescent lamps also offers an attractive alternative to HID systems. Low mercury T5HO fluorescent lamps can contain as little as 1.4 Mg of mercury compared with up to 70 Mg for a 400 watt metal halide lamp.

Energy efficient lighting upgrades can decrease facilities carbon footprint, since less fossil fuels are used to support savings achieved by the system upgrade.

5

6

Freezer & Refrigerated Areas

AB Series A R C T I C B AY I N D U S T R I A L L U M I N A I R E

Fluorescent high bay for cold and refrigerated storage from -20°F (-29°C) to 32°F (0°C).

Die formed reflectors are faceted for 4 and 6 lamp configurations with (2) optical distributions – medium and wide. Medium beam optical modules utilize 95% specular aluminum substrate while the wide distribution utilizes a high performance reflective polyester powder coat finish.

Enclosed, full bodied steel housing utilizes captive fasteners to protect optical assembly and assure structural integrity of housing while retaining heat for optimal system performance.

UL/CUL listed. Suitable for damp locations.

Housing is “Post” painted with a high performance polyester powder coat finish to protect against contaminants and oxidation.

Factory installed code compliant disconnect for safe and convenient means of disconnecting power. Allows easy ballast maintenance in colder environments.

Sealed and gasketed door frame provides a thermal environment for optimal lamp operation. Optional clear or prismatic shielding available.

Recommended Operating Range

Optional Occupancy Sensor: High humidity, low temperature provides 1400 sq. ft. of coverage in mounting heights up to 40'. MS/OB option keeps two inner lamps illuminated full time using outer lamps for occupancy control. MS/AO option relay rotates on/off cycle between 2 lamp and 4 lamp ballasts to minimize lamp degradation.

Temperature Control Capability Cooper Lighting recommends the following lamp operation when implementing a control system in colder ambient environments.

50˚F

10˚C

45˚F

7˚C

Arctic Bay (AB) Series

40˚F

4˚C

-20°F (-29°C)

35˚F

2˚C

30˚F

–1˚C

25˚F

–4˚C

20˚F

–7˚C

15˚F

–9˚C

10˚F

–12˚C

Fixture

# Lamps

Lamp Type

Routine Use (1)

Occasional Use (2)

5˚F

–15˚C

AB-454T5

4 Lamp

T5HO

2

ALL

0˚F

–18˚C

2AB-654T5

6 Lamp

T5HO

2

4

–5˚F

–21˚C

32°F (0°C) – 50°F (10°C)

–10˚F

–23˚C

–15˚F

–26˚C

–20˚F

–29˚C

Motion Sensor Options (Number of Lamps Controlled)

Fixture

# Lamps

Lamp Type

AB-454T5

4 Lamp

T5HO

Not Recommended

2

2AB-654T5

6 Lamp

T5HO

Not Recommended

2

0°F (-18°C)

Routine Use

Occasional Use (3)

Motion Sensor Options (Number of Lamps Controlled)

Motion Sensor Options (Number of Lamps Controlled)

Fixture

# Lamps

Lamp Type

Routine Use (1)

Occasional Use (2)

AB-454T5

4 Lamp

T5HO

2

ALL

2AB-654T5

6 Lamp

T5HO

2

(1) Luminaire

NOTES: achieves 40% or greater of relative light output at the indicated temperature in under 60 seconds. of relative light output at the indicated temperature in under 7 minutes. (3) Consult factory.

7

4 (2) Luminaire

achieves 40% to 80%

Mounting Accessories

TCB=Top Connector Box

AYC-Mounting chain set

Shielding Options

FH-1=Fixture Hook 2-1/2" (must be used with TCB)

Y-TOGGLE=Mounting Toggle and 10' or 25' cable

FL-1=Fixture Loop 2-1/2" (must be used with TCB)

RH-1=Retrofit Hanger (must be used with TCB)

SC-_-_=Stem Sets (fixed, Swivel or Adjustable SCF=Fixed SCA=Adjustable SCS=Swivel

WG=Wireguard and prismatic acrylic lens in doorframe

SWG=Heavy duty wireguard.

HB-SPS=Single or Two Point Suspension Cable Kit (Hook not included)

Arctic Bay System Performance -15°F (-26°C)

0°F (-18°C)

Mounting Ht.

40'

30' 400W MH

400W HPS

400W MH

400W HPS

20' 250W MH

250W HPS

250W MH

250W HPS

Energy Savings

29%

30%

42%

% Light Gain/Loss

43%

29%

30%

39%

40%

17%

-8%

17%

-6%

25%

2%

31%

12%

Part Number

AB-454T5-CLEBTL1

2AB-654T5-CLEBTL2

AB-454T5-CLEBTL1

2AB-654T5-CLEBTL2

T5

T5

T5

T5

10'

% Light gain/light loss utilize S/P adjusted lumens.

Arctic Bay System Efficiency The design of the Arctic Bay luminaire is optimized so that the internal components achieve maximum efficiency. Arctic Bay luminaires average 40% better lumens per watt (efficiency) than traditional HID high bay luminaires in -15°F (-26°C) and 0°F (-18°C) environments. At -15°F (-26°C) Arctic Bay provides up to 90% of light output and at 0°F (-18°C) a 6 lamp T5HO Arctic Bay provides over 100% of light output.

System Efficiencies 120

Lumens Per Watt

100

AB-454T5-CL-UNV-EBTL1

80

2AB-654T5-CL-UNV-EBTL2

60

400 Metal Halide High Bay

40

400 High Pressure Sodium High Bay

20 0

-15°F (-26°C)

0°F (-18°C)

8

AB Series

A R C T I C B AY I N D U S T R I A L L U M I N A I R E

Ordering Information

Sample Number: 2AB-654T5-UNV-EBTL2-MS/0B-U

Width Blank=15" 2=24" Series AB=Arctic Bay Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No. of Lamps 4=4 Lamps (AB) 6=6 Lamps (2AB) Lamp Type 54T5=54W T5HO Lamp Distribution Blank=Medium (Specular Aluminum) G=Wide (White Painted)

Ballast Type EBTL =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% Minimum Start Temp. -20°F (-29°C) No. of Ballast 1, 2 or 3 DIM=Consult Factory (5)

Shielding Blank=Prismatic Acrylic Lens w/Gasketed Door Frame CL=Clear Acrylic Lens w/Gasketed Door Frame Voltage (2) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt Options Lamps Installed L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (consult factory)

NOTES: (1)Requires use of voltage specific modular cord assembly. See accessories. (2)Voltage must be specified when ordered with plugs or motion sensor. (3)Specify voltage of ballast. (4)Requires (2) ballasts. Not available in 480V. (5)Dimming ballasts not recommended for use at temperature < 0°F (-18°C).

Packaging U=Unit Pack PAL=Palletized Out of Carton PALC=Job Pack In Carton

Options C3=3' White Cord Fixture Attached C6=6' White Cord Fixture Attached MS/OB=180° Aisle Modular Sensor Wired with Inner Two Lamps Constant On (3) MSO/OB=360° Modular Sensor Wired with Inner Two Lamps Constant On (3) MS/AO=180° Aisle Motion Sensor/Alternate Off (Alternate Ballast Relay) (3) (4) MSO/AO=360° Motion Sensor/Alternate Off (Alternate Ballast Relay) (3) (4) PC3-Voltage=3' Cord/Plug Fixture Attached(2) PC6-Voltage=6' Cord/Plug Fixture Attached(2) TCBP=Top Connector Box Plate (for use with TCB accessory) Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop HB-SPS=Single Point Cable Kit (13" Drop Length) Y-TOGGLE-=Y Mounting Toggle, #2 Cable (Specify 10' or 30') TCB=Top Connector Box (for use with TCBP option) SCA-48=Stem Set Adjustable 48" length SCF-=Stem Set Fixed (specify length) SCS=Stem Set 45° Swivel (specify length)

System Performance Table

-15°F (-26°C)

No. of Lamps

Lamp Lumen Fixture Ballast Lumens Maintenance 1 Efficiency Factor

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

TER 5

AB-454T5-CL-UNV-EBTL1

4

5000

93%

63%

1.00

0.86

10045

1.90

1.38

13847

210

$7.73

30

2AB-654T5-CL-UNV-EBTL2

6

5000

93%

65%

1.00

0.87

15875

1.90

1.38

21882

266

$5.95

39

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

0°F (-18°C)

No. of Lamp Lumen Fixture Ballast Lamps Lumens1 Maintenance Efficiency Factor

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

TER 5

AB-454T5-CL-UNV-EBTL1

4

5000

93%

63%

1.00

0.95

11097

1.90

1.38

15296

209

$6.96

30

2AB-654T5-CL-UNV-EBTL2

6

5000

93%

65%

1.00

1.04

18976

1.90

1.38

26157

277

$5.17

37

Comparison System 250W Metal Halide High Bay

1

20800

58%

78%

1.00



9422

1.50

1.22

11540

295

$10.47

34

250W High Pressure Sodium High Bay

1

30000

81%

78%

1.00



18978

0.62

0.79

14944

300

$8.23

50

400W Metal Halide High Bay

1

36000

58%

71%

1.00



14825

1.50

1.22

18157

455

$11.29

34

400W High Pressure Sodium High Bay

1

51000

81%

71%

1.00



29330

0.62

0.79

23095

464

$9.06

51

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data. 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor. 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA. 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^.0.5 based on 5000K lamps. 5 TER (Target Efficacy Rating) is calculated in accordance with NEMA standard LE 6 – 2008.

9

Photometrics Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Coefficients of Utilization

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 78 72 67 62 57 53 49 45 42 39 36

78 70 62 56 50 45 41 37 33 30 28

78 67 58 51 45 40 35 32 28 25 23

2AB-654T5-UNV-EBTL-U Electronic Ballasts (6) F54W T5HO lamps 4400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.1 x mounting height Efficiency 65.4% Test Report: 13590

78 65 55 47 41 36 31 28 25 22 19

73 65 59 53 48 43 39 35 32 29 27

73 64 56 49 44 38 34 31 28 25 22

20% 30% 50 30 10

73 62 53 46 40 35 31 28 24 21 19

70 63 57 51 46 42 38 34 31 28 26

70 62 54 48 43 38 34 30 27 24 22

70 60 52 45 40 35 31 27 24 21 19

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 6091 9250 14566 17260

%Lamp 23.1 35.0 55.2 65.4

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

%Fixture 35.3 53.6 84.4 100.0

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 83 77 72 66 61 57 53 49 45 42 39

83 75 67 60 54 49 44 40 37 33 30

2AB-654T5-CL-UNV-EBTL2-U Electronic Ballasts (6) F54W T5HO lamps 4400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.2 x mounting height Efficiency 69.7% Test Report: 14011

83 72 63 55 49 43 39 35 31 28 25

83 70 60 52 45 39 35 31 27 24 22

77 70 63 57 52 47 43 39 35 32 29

77 68 60 53 48 42 38 34 30 27 25

20%

77 67 58 50 44 39 34 31 27 24 21

30% 50 30 10 74 68 61 55 50 45 41 38 34 31 29

74 66 59 52 47 41 37 34 30 27 24

74 65 56 50 44 38 34 30 27 24 21

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 7014 10390 15800 18393

%Lamp 26.6 39.4 59.8 69.7

%Fixture 38.1 56.5 85.9 100.0

Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 75 70 65 60 56 51 48 44 41 38 36

75 67 61 55 49 44 40 37 33 30 28

75 65 57 50 45 39 35 32 28 25 23

AB-454T5-CL-UNV-EBTL1-U (2) Electronic Ballasts (4) 54W T5HO lamps 4400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.0 x mounting height Efficiency 62.8% Test Report: 14005

75 63 54 47 41 36 32 28 25 22 20

70 63 57 52 47 42 39 35 32 29 27

70 62 55 48 43 38 34 31 28 25 23

20%

70 60 52 46 40 35 31 28 25 22 20

30% 50 30 10 67 61 55 50 46 41 38 34 31 29 26

67 60 53 47 42 38 34 31 28 25 22

67 59 51 45 40 35 31 28 25 22 20

Relative Light Output Factors To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. The relative light output Arctic Bay (AB) factor should be applied -15°F (-26°C) 0°F (-18°C) as an additional light loss factor component. AB-454 0.86 0.95 2AB-654

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 4324 6484 9542 11049

%Lamp 24.6 36.8 54.2 62.8

0.87

1.04

%Fixture 39.1 58.7 86.4 100.0

Dimensions Arctic Bay Lamp Configurations AB 4-Lamp 4-3/4" [121mm] X=2-7/8" [74mm]

Dimensions – Top View 2AB 6-Lamp

17/64" Diameter Hole

5-1/2" [140mm] X

X

X

15-7/16" [392mm]

X=3-1/2" [89mm]

Access Plate Opening X

X

X

X

24" [610mm]

X

Mounting for Top Connector Box

24" [610mm]

11/16" [18mm] K.O. X=2-1/4" [58mm] Y=3-1/2" [89mm]

48" [1219mm]

X Y

10

Freezer, Refrigerated & Dry Storage

Pulse start metal halide operates at full light output down to -20°F (-29°C). High pressure sodium operates at full light output down to -40°F (-40°C). Wide variety of optical options for optimized performance. Fully enclosed and gasketed at three separate points to prevent entry and exit of contaminants.

Die-cast aluminum neck provides superior strength.

High performance efficacies over wide temperature ranges.

Extruded aluminum door frame features stainless steel latches eliminating the need for tools when re-lamping.

VertX

Recommended Operating Range 1 65˚F

18˚C

60˚F

16˚C

55˚F

13˚C

50˚F

10˚C

45˚F

7˚C

40˚F

4˚C

35˚F

2˚C

30˚F

–1˚C

25˚F

–4˚C

20˚F

–7˚C

15˚F

–9˚C

10˚F

–12˚C

5˚F

–15˚C

0˚F

–18˚C

–5˚F

–21˚C

–10˚F

–23˚C

–15˚F

–26˚C

–20˚F

–29˚C

Low temperature Individual fixture control (HSW-LT) allows you to save more energy. The sensor is integral to the fixture and provides 360 degree view and operates down to -40°F in 20%-90% relative humidity.

NOTES: 1 Suitable for 86°F (30°C) maximum ambient.

11

Optical Options

Mounting Options

TCB=Top Connector Box

ENSA 18 & 23= Enclosed & Gasketed Spun Aluminum

ENAV 19=Enclosed & Gasketed VerX Aisle Lighter

ENGR 16 & 21= Enclosed & Gasketed Borosilicate Glass

FH-1=Fixture Hook 2-1/2" FL-1=Fixture Loop 2-1/2" (must be used with TCB) (must be used with TCB)

ENPD 22=Enclosed & Gasketed Prismatic Acrylic. 30°C per 5009B72 1

80 4-Lamp T5 High Bay PS, MH and HPS

70

Superior Efficiency 60 Lumens Per Watt

HID’s lumens per watt (efficacy) remains consistently high over a wide temperature range. T5 and T8 systems provide lower lumens per watt as temperatures drop making them less efficient.

50 40 30 20 10 0

41°F 50°F 5°C 10°C

59°F 68°F 77°F 86°F 15°C 20°C 25°C 30°C

95°F 104°F 35°C 40°C

Ambient Environment

Lamp position: free burning (measured with constant current) 110

90

Group A: PMH, MH, HPS, Halogen, Incandescent

80

Group B: T5, PLH

100

Consistent Light Output Light output of pulse start metal halide is stable over the widest range of temperatures. Installation into a cold ambient environment has no affect on fixture performance down to -20°F making this light sources ideal for freezer applications.

70 Group C: T8, CFL

60 50 4-Lamp T5 High Bay

40

PS, MH and HPS

30 20 10 0

41°F 50°F 59°F 68°F 77°F 86°F 95°F 104°F 113°F 122°F 131°F 5°C 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C

Energy Savings Opportunities The Vertx Aisle Lighter optic allows the luminaires to be spaced further apart resulting in a reduction in the number of luminaires while still delivering higher horizontal light levels versus traditional products, or use the same number of luminaires and reduce the lamp wattage for higher vertical uniformity and equivalent horizontal illumination.

Typical High-bays vs. the VertX Horizontal Fixture Type

Qty. Req.

Avg.

Max.

Min.

Vertical Max./ Min.

Avg.

Max.

Min.

Max./ Min.

20.55

Aluminum High-Bay

11

30.25

33.8

15.4

2.19

17.5

59.6

2.9

Acrylic High-Bay

14

30.82

33.6

19.1

1.76

18.1

56.1

3.4

16.5

VertX

10

33.6

39.5

16.7

2.37

15.5

36.8

3.1

11.87

Acrylic Aluminum Aislelighter

18

29.97

35.1

12.2

2.88

20.1

55.8

2.3

24.26

Modified Aluminum High-Bay Aislelighter

18

30.5

34.6

18.6

1.86

20.8

54.7

3.1

17.65

Aisle: 8'10" x 200' x 32' Mounting Height: 30' Racks: 25' Reflectance: Ceiling: 50%, Aisle: 0%, Wall 10% • Horizontal Requirements – Fewer fixtures. • Vertical Requirements – Same number of fixtures but with lower wattage.

12

LUMARK

I N D U S T R I A L H I G H B AY

Ordering Information Sample Number: HPEB-ENSA18-M-400-MT-Q

Lamp Type Series HP=High EB=E&G Pressure Sodium (1) Benchmark MH=Metal Halide MP=Pulse Start MH (CWA) (2) ML=Pulse Start MH (Linear Reactor) (2), (3), (4)

Reflector Type ENSA=Enclosed & Gasketed Spun Aluminum

Reflector Diameter 18=18" 23=23"

ENAV=Enclosed & Gasketed VertX

19=19"

ENGR=Enclosed & Gasketed Glass Refractor

16=16" 21=21"

ENPD=Enclosed & Gasketed Prismatic Acrylic Refractor

22=22"

Socket Position/ Distribution (5) C=Concentrated M=Medium W=Wide

Lamp Wattage 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W 450=450W

Options & Accessories (10) (See Website)

Voltage (4) 120V 208V 240V 277V 347V 480V MT=Multi-Tap (7) TT=Triple-Tap (8) 5T=5-Tap (9)

NOTES: (1) Not available in 175, 200, 320, 350 & 450W. (2) 175, 200, 250, 320, 350 & 400W only. (3) 277V only, not available with Q or EM option. (4) Not available with HL or HC. (5) Factory set for concentrated, medium or wide distribution otherwise fixture is shipped in medium setting. (6) Products also available in non-US voltages and 50Hz for international markets. Consult your Cooper Lighting Representative for availability and ordering information. (7) Multi-tap ballast 120/208/240/277V wired 277V. (8) Triple-tap ballast 120/277/347V wired 347V. (9) 5-tap ballast 120/208/240/277/480V wired 277V. (10) Must be listed in the order shown and separated by a dash.

System Performance Table

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

250W PSMH Aluminum High Bay

1

23000

80%

84%

1.00

15537

1.50

1.22

19029

291

$5.80

55

320W PSMH Aluminum High Bay

1

32000

79%

84%

1.00

21346

1.50

1.22

26144

368

$5.33

60

350W PSMH Aluminum High Bay

1

36500

81%

84%

1.00

24965

1.50

1.22

30575

400

$4.96

65

400W PSMH Aluminum High Bay

1

41000

80%

84%

1.00

27696

1.50

1.22

33921

452

$3.05

63

400W Metal Halide High Bay

1

36000

58%

78%

1.00

16307

1.50

1.22

19972

455

$9.33

34

400W High Pressure Sodium High Bay

1

50000

81%

78%

1.00

31631

0.62

0.79

24906

464

$7.63

42

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

TER 5

70

Benchmark PSMH System Comparison

No. of Lamp Lumen Fixture Ballast Lamps Lumens1 Maintenance Efficiency Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

TER 5

Comparison System

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

750 PSMH Aluminum High Bay

1

82000

80%

84%

1.00

55366

1.50

1.22

67810

820

$4.58

750 PSMH Acrylic High Bay

1

82000

80%

90%

1.00

59106

1.50

1.22

72389

820

$4.02

80

1000 PSMH Aluminum High Bay

1

115000

80%

84%

1.00

77648

1.50

1.22

95099

1080

$4.31

74

1000 PSMH Acrylic High Bay

1

115000

80%

90%

1.00

82892

1.50

1.22

105122

1080

$3.78

85

1000W Metal Halide High Bay

1

102800

50%

85%

1.00

43690

1.50

1.22

53509

1085

$7.65

42

1000W High Pressure Sodium High Bay

1

130000

50%

85%

1.00

55250

1.50

1.22

67667

1100

$6.12

52

Benchmark PSMH System Comparison

No. of Lamp Lumen Fixture Ballast Lamps Lumens1 Maintenance Efficiency Factor

Comparison System1

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data. 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor. 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA. 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^.0.5 based on 5000K lamps. 5 TER (Target Efficacy Rating) is calculated in accordance with NEMA standard LE 6 – 2008.

13

Photometrics 90 1.0 2.7

60

4.4 6.1 7.8 30 CP/1000

MHEB-ENSA18W-400 400-Watt MH 36,000-Lumen Clear Lamp

60 12.2

18.3

CP/1000

80 75 70 65 61 56 51 47 43 40 36

Zone 0-30 0-40 0-60

6.1

MHEB-M-ENAV19-400-MT 400-Watt MH 36,000-Lumen Coated Lamp

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

30

Candlepower

Effective floor cavity reflectance 20% 80% 70% 70 50 30 10 70 50 30 10 80 73 66 60 54 49 43 39 35 31 28

80 71 63 55 49 43 38 33 29 26 22

Spacing Criterion

90

24.4

Coefficients of Utilization

80 69 60 52 45 40 34 29 25 22 19

79 74 69 64 59 55 50 46 42 39 36

79 72 65 59 53 48 43 38 34 31 27

79 70 62 55 49 43 38 33 29 25 22

79 68 59 51 45 39 34 29 25 22 19

50

50% 30 10

75 69 63 57 52 46 42 37 33 30 27

75 67 60 53 48 42 37 32 29 25 22

75 66 58 51 44 39 34 29 25 22 19

50

30% 30 10

10% 50 30 10

0% 0

72 66 61 55 50 45 41 36 32 29 26

72 65 58 52 47 42 37 32 28 25 22

69 64 59 53 49 44 40 35 32 28 25

68 61 54 48 42 37 32 27 24 20 17

72 64 57 50 44 39 34 29 25 22 19

69 63 57 51 46 41 36 32 28 24 21

69 62 55 49 43 38 33 29 25 22 19

1.7

%Lamp 19.3 35.7 64.2

Zone 0-90 90-180 Total

%Lamp 67.5 0.0 67.5

Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

86 82 76 72 67 63 59 55 52 49 46

86 77 69 62 56 50 46 42 39 36 33

Spacing Criterion Zone 0-30 0-40 0-60

%Lamp 35.6 51.9 71.0

86 75 66 58 52 47 42 38 35 32 30

84 80 75 70 65 61 58 54 51 48 45

84 78 71 65 59 55 50 47 43 40 38

84 76 68 61 55 50 46 42 39 36 33

84 74 65 58 51 46 42 38 35 32 30

50

50% 30 10

81 75 69 63 58 53 49 46 42 40 37

81 73 66 59 54 49 45 41 38 35 33

81 72 64 57 51 46 42 38 35 32 30

50

30% 30 10

10% 50 30 10

0% 0

77 72 66 61 56 52 48 45 42 39 37

77 71 64 58 53 48 44 41 38 35 33

74 69 64 59 55 51 47 44 41 38 36

73 66 60 54 48 44 40 36 33 31 29

77 70 62 56 50 45 41 38 35 32 30

74 68 62 57 52 48 44 40 37 35 32

74 68 61 55 50 45 41 38 35 32 30

1.4 Zone 0-90 90-180 Total

CP 7738 7636 7494 7586 7996 8744 9356 9456 9155 8182 6848 4444 1858 900 414 150 47 8 0

Candlepower

Effective floor cavity reflectance 20% 80% 70% 70 50 30 10 70 50 30 10 86 79 72 66 60 55 51 47 44 41 38

Degree 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

%Lamp 72.6 0 72.6

Degree 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

CP 17474 21011 24412 23040 20812 18941 17196 15536 13375 10618 7666 4318 2550 1165 312 63 14 0 0

Dimensions ESNA18

ENAV19

29-7/16" [748mm]

18" [457mm]

ENGR21

ENGR 16" Maximum Height 30-3/8" [722mm]

30" [762mm]

19" [483mm]

ENPD22

ENPD22 Maximum Height 30-1/2" [775mm] Drop Bottom Adds 3-1/2" to Overall Height

ENGR 21" Maximum Height 29-7/8" [759mm]

16" [406mm] or 21" [533mm]

22" [559mm]

14

Refrigerated & Warehouse Areas

HB/2HB Series H I G H - B AY I N D U S T R I A L L U M I N A I R E

Ideal for refrigerated storage from 32°F (0°C) and dry storage, shipping and receiving with temperatures ranging from 50°F (10°C) to 149°F (65°C) when used with high ambient ballast and uplight configuration.

Lens and door frame provides the thermal environment for optimal lamp operation down to 32°F (0°C). Optional clear or prismatic shielding available.

Full bodied steel housing utilizes captive fasteners to protect optical assembly, assure structural integrity, and retain heat for optimal thermal performance. Order NUA option for refrigerated applications less than 50°F (10°C).

Housing is “Post” painted with a high performance polyester powder coat finish to protect against contaminants and oxidation.

Optional top access plate allows service in electrical compartment without removal of lamps (T8 only).

UL/CUL listed. Suitable for damp locations.

Factory installed code compliant disconnect for safe and convenient means of disconnecting power. Allows easy ballast maintenance in colder environments. Die formed reflectors are faceted for 4 and 6 lamp configurations with two optical distributions –medium and wide. Medium beam optical modules utilize 95% specular aluminum substrate while the wide distribution utilizes a high performance reflective polyester powder coat finish.

Recommended Operating Range 50˚F

10˚C

45˚F

7˚C

40˚F

4˚C

35˚F

2˚C

30˚F

–1˚C

25˚F

–4˚C

20˚F

–7˚C

15˚F

–9˚C

10˚F

–12˚C

5˚F

–15˚C

0˚F

–18˚C

–5˚F

–21˚C

–10˚F

–23˚C

–15˚F

–26˚C

–20˚F

–29˚C

Integral occupancy sensor available and provides from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of coverage in a maximum mounting height of 40'.

Optional modular power receptacle meets UL2459 and NEC 410.73 and is UL/cUL rated for make and break under load from outside the luminaire for safe installation and speed maintenance.

Temperature Control Capability HB/2HB Series w/Non-Uplight Housing, Door Frame & Lens 32°F (0°C) – 50°F (10°C)

50°F (10°C) +

# Lamps Controlled (1)

# Lamps Controlled (1)

# Lamps

Lamp Type

4 Lamp

T8

2

ALL

4 Lamp

T5HO

2

ALL

6 Lamp

T8

2

4

6 Lamp

T5HO

2

4

NOTES: (1) Recommended minimum number of lamps for use with an occupancy sensor.

15

Cooper Lighting recommends the following lamp operation when implementing a control system in colder ambient environments.

Shielding Options

Modular F-Bay Power Supply

WG=Wireguard and prismatic acrylic lens in doorframe

G2=Optional gasketed door available

SWG=Heavy duty stock wireguard

Modular Power Cord & Plugs in 120, 277, 347 & 480V configurations

MP=Modular Power Supply Receptacle supplied mounted into fixture access plate

MP3=3' Modular Power Cord MP6=6' Modular Power Cord

MMS=Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle

Mounting Accessories

TCB=Top Connector Box

FH-1=Fixture Hook 2-1/2" FL-1=Fixture Loop 2-1/2" RH-1=Retrofit Hanger SC-_-_=Stem Sets (fixed, (must be used with TCB) (must be used with TCB) (must be used with TCB) Swivel or Adjustable SCF=Fixed SCA=Adjustable SCS=Swivel

AYC-Mounting chain set

Y-TOGGLE=Mounting Toggle and 10' or 25' cable

HB-SPS=Single or Two Point Suspension Cable Kit (Hook not included)

HB/2HB System Performance 32°F (0°C)

50°F (10°C)

Mounting Ht.

40'

30' 400W MH

400W HPS

400W MH

400W HPS

400W MH

400W HPS

400W MH

400W HPS

27%

29%

50%

51%

35%

19%

28%

10%

20' 250W MH

250W HPS

250W MH

250W HPS

400W MH

400W HPS

250W MH

250W HPS

50%

51%

47%

48%

4%

-19%

12%

-14%

10' Energy Savings

48%

49%

46%

47%

% Light Gain/Loss

23%

25%

53%

54%

9%

-13%

11%

-16%

Part Number

HB-454T5-CLEBT1-NUA

HB-432-CLEB8/PLUS-NUA

2HB-654T5-CLUNV-EBT2-NUA

43%

29%

12%

2HB-632-CLEB8/PLUS-NUA

-9%

HB-454T5-CLEBT1-NUA

HB-432-CLEB8/PLUS-NUA

2HB-654T5-CLUNV-EBT2-NUA

2HB-632-CLEB8/PLUS-NUA

T5

T8

T5

T8

T5

T8

T5

T8

% Light gain/light loss utilize S/P adjusted lumens.

HB/2HB F-Bay System Efficiency

System Efficiencies 120 100 Lumens Per Watt

The design of the enclosed HB and 2HB F-Bay luminaires is optimized so that the internal components achieve maximum efficiency. HB and 2HB Series luminaires average up to 50% better lumens per watt (efficiency) than traditional HID high bay luminaires in 32°F (0°C) through 50°F (10°C) environments. At these temperatures HB and 2HB F-Bays provide over 100% of light output.

HB-454T5-CL-UNV-EBT2-NUA

80

2HB-632-CL-EB/PLUS-NUA

60

400 Metal Halide High Bay

40

400 High Pressure Sodium High Bay

20 0

32°F (0°C)

50°F (10°C)

16

HB/2HB Series Ordering Information

H I G H - B AY I N D U S T R I A L L U M I N A I R E

Sample Number: 2HB-632-A-UNV-EB82/PLUS-NUA-U

Series HB=High Bay Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No. of Lamps 4=4 Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamp (HB/2HB) 28T5=28W T5 Lamp (2HB) 54T5=54W T5HO Lamp (HB/2HB) Distribution Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White) Shielding Blank=None A=Prismatic Acrylic Lens & Door Frame (HB/2HB) WG=Wireguard & Door Frame (2HB) A/WG=Acrylic Lens, Wireguard & Door Frame (HB/2HB) CL=Clear Acrylic Lens & Door Frame (HB/2HB) CL/WG=Clear Lens, Wireguard & Door Frame (HB/2HB) CL/DWG=Clear Lens, Drop Wireguard & Door Frame (HB/2HB) DWG=Drop Wireguard & Door Frame (2HB) A/DWG=Acrylic Lens, Drop Wireguard & Door Frame (HB/2HB) Voltage (2) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt

Packaging Options U=Unit Pack NUA=No Uplight Apertures In Housing PAL=Palletized Out of Carton UPL=Uplight Apertures (9) PALC=Palletized In Carton PI/CPI=Plug-In (1, 2 or 3) (see pg. 30) TILW=Tandem Inline Wiring MWS=Modular Wiring System MS=180° Aisle Coverage Motion Sensor (5) MSO=360° Coverage Motion Sensor (5) C3=3' Power Cord C6=6' Power Cord G2=Gasketed Door (Requires Selection of Lensed Door Frame) MP=Modular Power Receptacle (1) PC3-=3' Power Cord & Plug (Specify Voltage) (2) PC6-=6' Power Cord & Plug (Specify Voltage) (2) TAP=Top Access Plate (11) TCBP=Top Connector Box Plate (6)

Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (2) (see table on pg. 27)

Width Blank=15" 2=24"

Ballast Type T8 Systems EB8 =T8 Electronic Instant Start.(4) Total Harmonic Distortion < 10% No. of Ballast 2 or 3 EB8 /PLUS= T8 Electronic Instant Start.(4) High Ballast Factor >1.15. No. of Ballast Total Harmonic Distortion < 10% 2 or 3 ER8 =T8 Electronic Program Rapid Start.(4) Total Harmonic Distortion < 10% No. of Ballast 2 or 3 ER8 /PLUS= T8 Electronic Program Start.(4) High Ballast Factor >1.15. No. of Ballast Total Harmonic Distortion < 10% 2 or 3

T5 Systems EBT =T5 Linear Electronic Program Rapid Start.(3) Total Harmonic Distortion < 10% No. of Ballast 2 or 3 EHT =T5 Linear Electronic Start High Ambient. Total Harmonic Distortion < 10% (7) (8) (12) No. of Ballast 2 or 3 DIM=Consult Factory (12)

Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (10) TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop HB-SPS=Single Point Cable Kit (13" Drop Length), (Hook not included) Y-TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30') MC3=3' Modular Power Cord MPC3=3' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS-CPD1200H=180° Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V) SWG/2HB-4FT-B=Heavy Duty Wireguard (2HB) SWG/HB-4FT-B=Heavy Duty Wireguard (HB)

NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs. (2) Voltage must be specified when ordered with plugs, motion or emergency ballasts. (3) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) in open uplight configuration. (4) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration. (5) Specify voltage. (6) For use with Top Connector Box accessory. See accessories. (7)2 lamp ballast configurations only in UNC versions. (8) EHT ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option. (9) Cannot be combined with cord or cord & plug option. See PI ordering information below. (10) Not for use in high abuse applications such as gymnasiums. (11) For use with T8 system with a maximum of two ballasts (including EM ballast). (12)Dimming ballasts not recommended for use at temperature < 0°F (-18°C).

System Performance Table

50°F (10°C)

No. of Lamps

Lamp Lumen Fixture Lumens Maintenance 1 Efficiency

Ballast Factor

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

TER 5

HB-454-CL-UNV-EBT2-NUA

4

5000

93%

65%

1.00

1.14

13783

1.90

1.38

18998

226

$5.86

HB-432-CL-UNV-EB81/PLUS-NUA

4

3100

94%

70%

1.15

1.00

9423

1.95

1.40

13159

156

$4.69

34

2HB-654-CL-UNV-EBT2-NUA

6

5000

93%

69%

1.00

1.05

20184

1.90

1.38

27822

330

$5.51

31

2HB-632-CL-UNV-EB82/PLUS-NUA

6

3100

94%

80%

1.15

1.12

18083

1.95

1.40

25252

226

$3.11

41

Ballast Factor

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

32°F (0°C)

No. of Lamps

Lamp Lumen Fixture Lumens Maintenance 1 Efficiency

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

28

TER 5

HB-454-CL-UNV-EBT2-NUA

4

5000

93%

65%

1.00

1.20

14508

1.90

1.38

19998

238

$5.86

HB-432-CL-UNV-EB81/PLUS-NUA

4

3100

94%

70%

1.15

0.98

9235

1.95

1.40

12896

159

$4.88

27 34

2HB-654-CL-UNV-EBT2-NUA

6

5000

93%

69%

1.00

1.20

23068

1.90

1.38

31797

350

$5.11

29

2HB-632-CL-UNV-EB82/PLUS-NUA

6

3100

94%

80%

1.15

0.92

14854

1.95

1.40

20742

213

$3.56

44

Comparison System 250W Metal Halide High Bay

1

20800

58%

78%

1.00



9422

1.50

1.22

11540

295

$10.47

34

250W High Pressure Sodium High Bay

1

30000

81%

78%

1.00



18978

0.62

0.79

14944

300

$8.23

50

400W Metal Halide High Bay

1

36000

58%

71%

1.00



14825

1.50

1.22

18157

455

$11.29

34

400W High Pressure Sodium High Bay

1

51000

81%

71%

1.00



29330

0.62

0.79

23095

464

$9.06

51

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data. 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor. 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA. 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^.0.5 based on 5000K lamps. 5 TER (Target Efficacy Rating) is calculated in accordance with NEMA standard LE 6 – 2008.

17

Photometrics Coefficients of Utilization

Coefficients of Utilization

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

77 72 67 62 57 53 49 45 42 39 36

77 70 62 56 50 45 41 37 33 30 28

77 67 59 51 45 40 36 32 28 25 23

HB-454T5-CL-UNV-EBT1-NUA-U Electronic Ballasts (4) 54W T5HO lamps 4400 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.1 x mounting height Efficiency 65.0% Test Report: 12686

77 65 56 48 42 36 32 28 25 22 19

72 65 59 53 48 43 39 36 32 29 27

72 64 56 50 44 39 35 31 28 25 22

20% 30% 50 30 10

72 62 54 47 41 35 31 28 24 21 19

69 63 57 51 47 42 38 35 31 28 26

69 62 55 48 43 38 34 31 27 24 22

69 60 52 46 40 35 31 28 24 21 19

Lumens 4059 6300 9843 11440

%Lamp 23.1 35.8 55.9 65.0

%Fixture 35.5 55.1 86.0 100.0

Coefficients of Utilization

82 76 71 65 61 56 52 48 45 41 39

82 74 66 59 53 48 44 40 36 33 30

82 71 62 54 48 42 38 34 30 27 25

2HB-654T5-CL-UNV-EBT2-NUA-U (2) Electronic Ballasts (6) 54W T5HO lamps 4400 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 0.9 x mounting height Efficiency 68.9% Test Report: 12699

82 69 59 51 44 38 34 30 27 24 21

77 69 62 56 51 46 42 38 35 31 29

77 67 59 52 47 41 37 33 30 27 24

20%

77 66 57 49 43 38 34 30 27 23 21

30% 50 30 10

Lumens 6798 10175 15465 18187

73 67 60 54 49 45 41 37 34 31 28

73 65 58 51 46 41 36 33 29 26 24

73 64 55 49 43 37 33 30 26 23 21

%Lamp 25.8 38.5 58.6 68.9

78 70 63 57 51 45 41 37 34 30 28

78 69 60 53 46 41 36 32 29 25 23

78 67 57 49 43 37 32 29 25 22 19

75 68 61 55 49 44 40 36 33 29 27

75 66 58 51 45 40 36 32 28 25 22

75 65 56 49 42 37 32 28 25 22 19

Zone 0-30 0-40 0-60 0-90

Lumens 2573 4113 6757 8017

%Lamp 22.6 36.1 59.3 70.3

%Fixture 32.1 51.3 84.3 100.0

96 89 82 76 70 64 60 55 51 47 44

96 86 76 69 62 55 50 45 41 37 34

96 83 72 63 55 48 43 39 34 30 27

96 80 68 58 50 44 38 34 30 26 23

89 81 72 65 59 52 48 43 39 35 32

89 78 69 61 53 47 42 38 34 30 27

20%

89 77 66 57 49 43 38 34 30 26 23

30% 50 30 10 85 78 70 63 57 51 46 42 38 35 32

85 76 67 59 52 46 41 37 33 29 26

85 74 64 56 49 42 38 33 29 26 23

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 4736 7292 11564 13739

%Lamp 27.7 42.6 67.6 80.3

%Fixture 34.5 53.1 84.2 100.0

Relative Light Output Factors To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. HB/2HB Series Non-Uplight Housing, The relative light output Door Frame & Lens factor should be applied 32°F (0°C) 50°F (10°C) as an additional light loss HB-432-NUA 1.11 1.19 factor component.

HB/2HB Lamp Configurations 2HB 6-Lamp T5/T8

HB 4-Lamp T5/T8 4-3/4" [121mm]

4-3/4" [121mm] X

84 70 59 51 44 38 33 29 25 22 19

30% 50 30 10

Zonal Lumen Summary

2HB-632-CL-UNV-EB82-NUA-U Electronic Ballasts (6) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 0.9 x mounting height Efficiency 80.3% Test Report: 12697

%Fixture 37.4 55.9 85.0 100.0

Dimensions

X=2-7/8" [74mm]

84 72 63 55 48 42 37 33 29 26 23

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

84 75 67 60 53 48 43 39 35 31 29

20%

Coefficients of Utilization

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

84 78 72 66 61 56 52 48 44 41 38

HB-432-CL-UNV-EB81/PLUS-NUA-U (2) Electronic Ballasts (4) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.1 x mounting height Efficiency 70.3% Test Report: 12684

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

X

X

15-7/16" [392mm]

X

X=3-1/2" [89mm]

X

X

X

X

24" [610mm]

Top View

HB-454-NUA

1.28

1.24

2HB-632-NUA

0.82

1.02

2HB-654-NUA

1.35

1.16

17/64" Diameter Hole

2HB

Access Plate Opening

Mounting for Top Connector Box

HB 24" [610mm]

Access Plate Opening 11/16" [18mm] K.O. X=2-1/4" [58mm]

Mounting for Top Connector Box

15-7/16" [392mm]

X=2-1/4" [58mm] 11/16" [18mm] K.O.

Y=3-1/2" [89mm]

48" [1219mm]

X Y

17/64" Diameter Hole

48" [1219mm]

Y=3-1/2" [89mm]

X Y

18

Food Processing & Complex Environments

HBHD Series H O S E D O W N H I G H - B AY I N D U S T R I A L L U M I N A I R E

High performance white enamel finish improves efficiency and protects against elements. Optional brushed stainless steel finish for corrosive chemical environments. Sealed housing is enclosed and gasketed to provide 800 psi hose down protection.

White, closed cell, Flexiseal™ gasketing surrounds perimeter of lens to seal lens to door frame and around perimeter of door to seal door to housing. Another layer seals fixture to ceiling system after installation.

Factory installed code compliant disconnect for safe and convenient means of disconnecting power.

One piece, heavy gauge extruded lens in prismatic or clear acrylic.

Die formed reflectors are faceted for 4 and 6 lamp configurations with two optical distributions – medium and wide. Medium beam optical modules utilize 95% specular aluminum substrate while the wide distribution utilizes a high performance 95% reflective polyester powder coat finish.

Captive, flush mounted stainless steel fasteners secure one piece door to housing.

UL/cUL and CSA listed for wet locations. Manufactured in compliance with USDA, FDA, NSF and Federal Standard 209E in surface mount applications. IP65 rated.

System Performance Table

2HBHD System Comparison

No. of Lamps

Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

2HBHD-432-CL-EB81/PLUS

4

3100

94%

68%

1.15

9128

1.95

1.40

12747

147

$4.71

2HBHD-632-CL-EB82/PLUS

6

3100

94%

68%

1.15

13693

1.95

1.40

19121

221

$4.72

2HBHD-454T5-CL-EBT1

4

5000

93%

59%

1.00

10974

1.90

1.38

15127

229

$8.21

2HBHD-654T5-CL-EBT2

6

5000

93%

59%

1.00

16461

1.90

1.38

22690

346

$8.27

250W Metal Halide Encl. & Gasketed High Bay

1

20800

58%

68%

1.00

8179

1.50

1.22

10018

295

$13.90

250W High Pressure Sodium Encl. & Gasketed High Bay

1

30000

81%

68%

1.00

16475

0.62

0.79

12973

300

$10.91

400W Metal Halide Encl. & Gasketed High Bay

1

36000

58%

68%

1.00

14157

1.50

1.22

17338

455

$12.39

400W High Pressure Sodium Encl. & Gasketed High Bay

1

50000

81%

68%

1.00

27459

0.62

0.79

21621

464

$10.13

Comparison System

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data. 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor. 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA. 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^.0.5 based on 5000K lamps.

19

Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

81 75 68 62 57 53 49 45 42 40 37

81 72 63 56 49 44 40 36 33 31 28

81 69 58 50 44 38 34 31 28 25 23

2HBHD-632-CL-UNV-EB82 (2) Electronic Ballasts (6) F32T8/TL835 lamps 3000 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height Efficiency 68.1% Test Report: 2HBHD632CL.IES

81 66 55 46 39 34 30 27 24 21 19

76 67 59 52 47 42 38 35 32 29 27

76 65 56 48 42 37 33 30 27 25 23

Coefficients of Utilization 20% 30% 50 30 10

76 63 53 45 38 34 30 26 24 21 19

72 65 57 51 45 41 37 34 31 29 27

72 63 54 47 41 37 33 29 27 24 22

72 61 52 44 38 33 29 26 23 21 19

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180

Lumens 3768 6124 10121 12258 12258

%Lamp 20.9 34.0 56.2 68.1 68.1

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

%Fixture 30.7 50.0 82.6 91.5 100.0

70 65 60 55 51 47 44 41 38 36 34

70 63 56 50 45 40 37 34 31 29 27

70 61 52 45 40 36 32 29 26 24 22

2HBHD-654T5-CL-UNV-EBT2 (3) Electronic Ballasts (6) F54T5HO/841 54W lamps 4400 lumens Spacing criterion: (II) 1.0 x mounting height, (⊥) 1.2 x mounting height Efficiency 59.2% Test Report: 2HBHD654T5CL.IES

HBHD System Performance

70 59 49 42 36 32 28 26 23 21 19

66 59 53 47 42 39 35 32 30 28 26

20%

66 66 57 56 50 47 44 41 39 36 35 31 31 28 28 25 26 23 24 21 22 19

30% 50 30 10 63 57 51 46 41 37 34 32 29 27 25

63 55 48 43 38 34 31 28 26 23 22

63 54 46 40 35 31 28 25 23 21 19

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180

Lumens 5876 8802 13385 15627 15627

%Lamp 22.3 33.3 50.7 59.2 59.2

%Fixture 37.6 56.3 85.7 75.3 100.0

Dimensions

77°F (25°C)

Dimensions – Top View

HBHD Lamp Configurations 4-lamp

Mounting Ht.

30' 400W MH

400W HPS

400W MH

400W HPS

4-1/2" [115mm]

250W MH

250W HPS

250W MH

250W HPS

23-11/16" [602mm] 48" [1219mm]

6-lamp

10'

50%

51%

% Light Gain/Loss

21%

Part Number

2HBHD-432-CLEB81/PLUS

51%

-2%

9%

52% -13%

2HBHD-632-CLEB82/PLUS

T8

22% 34%

(4) 3/8" [10mm] Dia. Mounting Hole

36" [914mm]

5" 5" 5" [127mm] [127mm] [127mm]

20'

Energy Savings

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

24%

24%

14%

24%

2HBHD-454T5CL-EBT1

25% 5%

4-1/2" [115mm] X=3-1/2" [89mm]

X

X

X

X

1-1/2" [38mm]

X

23-11/16" [602mm]

2HBHD-654T5CL-EBT2

10-3/16" [259mm]

12" [305mm]

(2) 7/8" [22mm] KO Gasketed Access Plate

23-11/16" [602mm]

T5

% Light gain/light loss utilize S/P adjusted lumens.

Ordering Information

Sample Number: 2HBHD-654T5-A-UNV-EBT2-U

Width 2=24" Series HBHD=High Bay Hose Down No. of Lamps 4=4 Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamp 28T5=28W T5 Lamp 54T5=54W T5HO Lamp Distribution Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White) Shielding (6) A=Prismatic Acrylic Lens & Door Frame CL=Clear Acrylic Lens & Door Frame

Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (2) Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (1) (see table on pg. 27)

Ballast Type (1) T8 Systems EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.15. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

Options (3) SSF304=Stainless Steel Housing and Frame, 304 Finish Packaging U=Unit Pack PAL=Pallet Pack PALC=Job Pack In Carton

No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.15. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 T5 Systems EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EHT =T5 Linear Electronic Start High Ambient. Total Harmonic Distortion < 10% (2) No. of Ballast 1, 2 or 3 DIM=Consult Factory (5)

NOTES: (1) Voltage must be specified when ordered with plugs or emergency ballasts. (2) 2 lamp ballast configurations only in UNC versions. (3) Cord and plug options only available with pendant mount option. (4) Stems must be ordered separately, see accessories.(5) Dimming ballasts not recommended for use at temperature < 0F. (6) Fixture without a lens do not qualify as Hose Down rated.

20

Freezer, Refrigerated Areas, & Food Processing

VT3 Series VA P O R T I T E L U M I N A I R E

Sealed and gasketed enclosure utilizes internal heat for optimal performance in ambient environments down to -20°F (-29°C).

Surface/chain mount from supplied mounting bracket.

Durable fiberglass housing is reinforced polyester and selfextinguishing (ASTM-D635-74) plastic of a permanent pearl gray color.

Polyurethane gasketing is formed in the housing providing a continuous seamless seal for the diffuser.

High impact lens options to withstand the most demanding environments. Applications include holding freezers, refrigerated storage, walk-in freezers, food processing and outdoor locations. A watertite hub for 1/2" conduit entry is provided at each end of housing (standard) for continuous feed. Sturdy cam latches clamp diffuser tightly for a positive seal between housing, gasketing and diffuser.

Tethered gear tray for tool-less access to ballast compartment and hands-free maintenance. Optional die formed high reflective polyester powder coat or high performance 95% Specular reflector.

UL Listed for wet locations (standard). UL/CUL Listed. IP65 rated. Optional IP67 rating.

Factory installed code compliant disconnect for safe and convenient means of disconnecting power. Allows easy ballast maintenance in colder environments.

Recommended Operating Range 50˚F

10˚C

45˚F

7˚C

40˚F

4˚C

35˚F

2˚C

30˚F

–1˚C

25˚F

–4˚C

20˚F

–7˚C

15˚F

–9˚C

10˚F

–12˚C

# Lamps

Lamp Type

5˚F

–15˚C

2 Lamp

T5HO



2

0˚F

–18˚C

3 Lamp

T5HO

1

3

33°F (0°C) – 50°F (10°C)

50°F (10°C) +

# Lamps

Lamp Type

# Lamps Controlled (1)

# Lamps Controlled (1)

2 Lamp

T8

2

2

2 Lamp

T5HO

2

2

3 Lamp

T8

3

3

–5˚F

–21˚C

–10˚F

–23˚C

–15˚F

–26˚C

–20˚F

–29˚C

Temperature Control Capability VT3 Series -15°F (-26°C) – 0°F (-18°C)

0°F (-18°C) – 32°F (0°C)

# Lamps Controlled (1)

# Lamps Controlled (1)

NOTES: (1) Recommended minimum number of lamps for use with a control or switching system.

21

Cooper Lighting recommends the following lamp operation when implementing a control system in colder ambient environments.

Mounting Accessories

Lens Options

VT2-SS-MBK=Optional Stainless Steel Mounting Bracket for simple installation

VT2-Chain/Set-U=Chain Hanging Set Order One (1) Kit for each 2' or 4' Fixture, Two (2) Kits Recommended for 8' Fixture

• Brass Mounting Stud - used with steel mounting brackets

DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-50=50% High Impact Additive DR-100=100% High Impact Additive

VT3 Series System Performance 0°F (-18°C)

-15°F (-26°C)

33°F (0°C)

Lamp Type 175W MH

150W HPS

175W MH

150W HPS

175W MH

150W HPS

175W MH

150W HPS

175W MH

150W HPS

175W MH

150W HPS

175W MH

150W HPS

Energy Savings

34%

26%

55%

49%

63%

58%

35%

27%

59%

53%

76%

72%

63%

58%

% Light Gain/Loss

43%

51%

1%

14%

16%

28%

45%

52%

29%

39%

16%

28%

37%

46%

VT3-254T5-UNV- VT3-354T5-UNVEBT1-M4 EBT2-M4

VT3-354T5-UNV- VT3-254T5-UNVEBT2-M4 EBT2-M4

Part Number

T5

T5

T5

T5

VT3-254T5-UNVEBT1-M4

VT3-232EB8/PLUS-M4

VT3-332EB8/PLUS-M4

T5

T8

T8

% Light gain/light loss utilize S/P adjusted lumens.

50°F (10°C) Lamp Type

Energy Savings % Light Gain/Loss Part Number

175W MH

150W HPS

175W MH

150W HPS

175W MH

150W HPS

54%

48%

69%

65%

53%

46%

32%

41%

18%

29%

33%

46%

VT3-254T5-UNVEBT1-M4

VT3-232EB8/PLUS-M4

VT3-332EB8/PLUS-M4

T5

T8

T8

% Light gain/light loss utilize S/P adjusted lumens.

VT3 Series System Efficiency The design of the VT3 series is optimized so that the internal components achieve maximum efficiency. VT3 Series luminaires average up to 60% better lumens per watt (efficiency) than traditional HID high bay luminaires in 0°F (-18°C) through 50°F (10°C) environments. At -15°F (-26°C) 3 lamp T5HO VT3 Series provides over 90% of light output. System Efficiencies 120

Lumens Per Watt

100

VT3-254T5-UNV-EBT2-M4

80

VT3-354T5-UNV-EBT2-M4

60

175W Metal Halide Luminaire

40

150W High Pressure Sodium Luminaire

20 0

-15°F (-26°C)

0°F (-18°C)

32°F (0°C)

22

VT3

VA P O R T I T E L U M I N A I R E

Ordering Information Sample Number: 8TVT3-254T5DR-UNV-EB82-M4-U

Width Blank=4' Length 8T=8' Length Series VT3=Vaportite (Gasketed Enclosure) Number of Lamps (3) 1=1 Lamp 2=2 Lamps 3=3 Lamps (Lamps not included)

Lamp Type 28=28W T5 Lamp 32=32W T8 Lamp 54T5=54W T5HO Lamp

Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt UNV=Universal Voltage 120/277V UNC=Universal Voltage 347/480V Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (3) (4) (see table on pg. 27)

Lens DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-50=50% High Impact Additive DR-100%=100% High Impact Additive (Extreme) NOTES: (1)Ballast type used only if ballast & voltage is chosen. (2)Not available when specifying emergency ballasts, voltage must be specific. (3) 3 Lamp 54W T5HO is recommended for ambient temperatures below 102°F (40°C) with EHT2 ballasts, and below 0°F (-18°C) with EHT1 ballast. (4) Emergency option in 3 lamp version must use remote mount test switch. (5) Top Hub required when stem mounting.

WL=Wet Location Ballast Type (1) Label T8 Systems EB8 =T8 Electronic Instant Start. (4) Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. (4) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start.(4) Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. (4) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 T5 Systems EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EHT =T5HO Linear Electronic Program Rapid Start High Ambient. Total Harmonic Distortion < 10% No. of Ballast (3) 1 or 2

Packaging Options U=Unit Pack 8L=8 Latches (IP67 Rating) PALC=Job Pack RIF1=Radio in Carton Interference Suppressor (5) TH=(2) Top Watertite Hubs TEH=(2) Top & (2) End Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry) (5) M4=Specular Reflector SSL=Stainless Steel Latches

Accessories (order separately) VT2-Chain/Set-U=Chain Hanging Set Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks. Order Two (2) Kits for each 4' or 8' Fixture VT2-SS-MBK=Stainless Steel Mounting Bracket VT2 Stem Bushing=1/2" – 3/8" (Required when using Stem/Sets, Requires (1) per (Stem/Set)

System Performance Table

50°F (10°C)

No. of Lamps

Lamp Lumen Fixture Ballast Lumens Maintenance 1 Efficiency Factor

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

TER 5

VT3-254T5-UNV-EBT2-M4

2

5000

93%

72%

1.00

0.94

6294

1.90

1.38

8676

97

$4.92

42

VT3-232-EB81/PLUS-M4

2

3100

94%

77%

1.15

0.99

5136

1.95

1.40

7172

65

$3.28

50

VT3-332-EB81/PLUS-M4

3

3100

94%

75%

1.15

0.98

7350

1.95

1.40

10263

101

$6.92

48

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

32°F (0°C)

No. of Lamps

Lamp Lumen Fixture Ballast Lumens Maintenance 1 Efficiency Factor

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

TER 5

VT3-254T5-UNV-EBT2-M4

2

5000

93%

72%

1.00

0.90

6026

1.90

1.38

8307

88

$4.71

46

VT3-232-EB81/PLUS-M4

2

3100

94%

77%

1.15

0.97

5032

1.95

1.40

7027

52

$2.66

48

VT3-332-EB81/PLUS-M4

3

3100

94%

75%

1.15

0.98

7350

1.95

1.40

10263

80

$5.47

49

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

0.76

5089

1.90

1.38

7015

79

0°F (18°C) VT3-254T5-UNV-EBT2-M4

-15°F (-26°C)

No. of Lamps

2

No. of Lamps

Lamp Lumen Fixture Ballast Lumens Maintenance 1 Efficiency Factor

5000

93%

72%

1.00

Lamp Lumen Fixture Ballast Lumens Maintenance 1 Efficiency Factor

Thermal Factor

Design System Lumens2

S/P Ratio3

Brightness Perception

S/P Adjusted Lumens4

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

$5.01 Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

TER 5

51

TER 5

VT3-254T5-UNV-EBT2-M4

2

5000

93%

72%

1.00

0.73

4888

1.90

1.38

6746

95

$6.26

43

VT3-354T5-UNV-EBT2-M4

3

5000

93%

60%

1.00

0.91

7553

1.90

1.38

10411

140

$7.23

35

175W Metal Halide Luminaire

1

13600

58%

69%

1.00



5474

1.50

1.22

6705

213

$14.65

23

150W High Pressure Luminaire

1

12900

81%

70%

1.00



7335

0.62

0.79

5776

188

$14.84

24

Comparison System

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data. 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor. 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA. 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^.0.5 based on 4100K lamps. 5 TER (Target Efficacy Rating) is calculated in accordance with NEMA standard LE 6 – 2008.

23

Photometrics Coefficients of Utilization

Coefficients of Utilization

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

91 82 74 67 61 56 51 47 43 40 37

91 78 67 58 51 45 40 36 32 29 26

VT3-232DR-UNV-EB81-WL-U (1) Electronic Ballast (2) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 77% Test Report: LTL10864.IES

91 74 61 53 44 38 33 29 25 22 20

91 70 56 46 39 32 28 24 20 17 15

84 71 61 54 48 42 37 33 30 27 24

84 68 57 49 42 36 31 27 24 21 19

20% 30% 50 30 10

84 66 53 44 37 31 27 23 20 17 15

79 67 58 51 45 40 36 32 29 26 23

79 65 54 47 40 34 30 27 23 20 18

79 63 51 43 36 30 26 23 19 17 14

Lumens 899 1512 2847 4169 4413

%Lamp 15.8 26.5 49.9 73.1 77.4

%Fixture 20.4 34.3 64.5 94.5 100.0

Coefficients of Utilization

91 83 76 69 63 58 53 49 45 41 38

91 79 69 61 54 48 43 38 34 31 28

VT3-332DR-UNV-EB81-WL-M4-U Electronic Ballasts (3) F32T8/835/RS lamps 2950 lumens Spacing criterion: (II) 1.4 x mounting height, (⊥) 1.4 x mounting height Efficiency 75% Test Report: 13879

91 76 64 55 47 41 36 31 27 24 22

91 73 59 50 42 35 31 26 23 20 17

84 73 64 57 51 45 40 36 32 29 26

84 71 60 52 45 39 34 30 26 23 21

20%

84 68 56 48 41 34 30 26 22 19 17

30% 50 30 10

Lumens 1677 2729 4910 6602

85 70 59 51 44 39 34 30 27 24 21

85 67 55 46 40 34 30 26 23 20 17

78 68 60 53 47 42 38 34 31 28 26

78 66 56 49 42 37 33 29 26 23 21

30% 50 30 10

78 63 53 45 38 33 29 25 22 19 17

75 65 57 51 45 40 37 33 30 27 25

75 63 54 47 41 36 32 28 25 22 20

75 61 51 44 38 32 28 25 22 19 17

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180

Lumens 1711 2691 4531 6093 6338

%Lamp 19.4 30.6 51.5 69.2 72.1

80 70 61 54 48 43 38 35 31 28 25

80 68 58 50 44 38 33 29 26 23 20

%Lamp 18.9 30.8 55.5 74.6

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

80 66 55 47 40 34 29 25 22 19 17

70 64 58 53 49 44 41 38 35 32 30

70 61 53 47 41 37 33 29 26 24 22

VT3-354T5HO-UNV-EBT2-M4-U (2) Electronic Ballasts (3) F54T5HO/835 lamps 4400 lumens Spacing criterion: (II) 1.4 x mounting height, (⊥) 1.3 x mounting height Efficiency 60% Test Report: 14003

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

85 74 64 57 51 45 41 37 33 30 27

20%

%Fixture 27.0 42.5 71.5 96.1 100.0

Coefficients of Utilization

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

85 77 70 65 59 54 50 46 43 39 37

VT3-254T5HODR-UNV-EB81-WL-M4-U Electronic Ballast (2) 54WT5HO/835 lamps 4400 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.1 x mounting height Efficiency 72% Test Report: 13881

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

%Fixture 24.5 39.8 71.7 96.4

Relative Light Output Factors

70 58 49 42 36 31 27 24 21 19 17

70 56 45 38 32 27 23 20 18 15 14

65 57 49 44 39 34 31 28 25 22 20

65 55 46 40 35 30 26 23 20 18 16

20% 30% 50 30 10

65 53 43 37 31 26 23 20 17 15 13

62 54 47 42 37 33 30 27 24 22 20

62 52 45 39 34 29 26 23 20 18 16

62 51 42 36 31 26 23 20 17 15 13

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180

Lumens 1987 3178 5592 7608 7853

%Lamp 15.1 24.1 42.4 57.6 59.5

%Fixture 25.3 40.5 71.2 96.9 100.0

VT3 Series

To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. The relative light output factor should be applied as an additional light loss factor component.

20°F (-6°C)

33°F (0°C)

VT3-232

-15°F (-26°C) 0°F (-18°C) –



0.67

0.97

50°F (10°C) 0.99

VT3-254

0.73

0.76

0.86

0.90

0.94

VT3-332





0.96

0.98

0.98

VT3-354

0.91

0.93







Dimensions Dimensions – Top View

VT3 Lamp Configurations 2-Lamp

1-Lamp X

4-7/8" [123mm]

6-15/16" [177mm]

3-Lamp X 4-7/8" [123mm]

X=1-13/32" [36mm] Y=2-1/2" [64mm]

38-3/4" [984mm] 1/4" x 28" Stud (2 Places)

X

4-7/8" [123mm]

X=1-13/32" [36mm]

41-1/2" [1054mm] Optional Back Hub Locations

4 Foot

X=1-13/32" [36mm] Y=2-1/2" [64mm]

6-5/8" [168mm] X=5-3/8" [137mm]

Y 6-15/16" [177mm]

X

49-13/16" [1265mm]

4-3/16" [106mm]

89-1/2" [2273mm] Optional Back Hub Locations

8 Foot

87-1/8" [2213mm] 1/4" x 28" Stud (4 Places)

6-5/8" [168mm] Y 6-15/16" [177mm]

X=5-3/8" [137mm]

X

40-13/16" [1037mm]

5-1/2" [140mm] 97-7/8" [2486mm]

4-3/16" [106mm]

24

Dry Storage & Warehouse Aisles

MB Series M I C R O - B AY L U M I N A I R E

UL/cUL listed to meet U.S. and Canadian standards.

Plug-In Connectors

Optional pre-wired factory installed multiple circuit plug-in connectors.

Cable Mounting Kit

Suspension is convenient and flexible with Aircraft Cable “Y” Toggle Mounting Kits. Adjustment for luminaire mounting height is provided at luminaire rather than structure.

Factory installed code compliant disconnect for safe and convenient means of disconnecting power. Specular Miro reflectors for precise light control minimum 95% total reflectivity. Three optical distribution patterns are available: Focus - SC < .9 Task - .9 ≤ SC < 1.2 Dimensions Normal - 1.2 ≤ SC ≤ 1.4

Integral occupancy sensor available and provides from 600 sq. ft. up to 1250 sq. ft. of coverage in a maximum mounting height of 40'. (Order separately)

Occupancy Sensor

Dimensions for Top View 7/8" [23mm] K.O. (3) Ceiling Stand-Off Embossments

4' and 8' 2-11/16" [69mm]

Rigid Exterior Connector

Rigid exterior connector/coupling with pre-punched holes facilitates easy installation of coupled sections up to 32' long. (Order separately)

Focus Beam, 1 or 2 Lamp

T5 Lamp Configurations

X

X=2-11/16" [69mm]

4-5/16" [110mm]

X=2-11/16" [69mm]

X

X=2-11/16" [69mm]

29/32" [24mm]

4-3/16" [107mm] X=2-11/16" [69mm]

Normal Beam, 1 or 2 Lamp

1-3/16" [31mm]

4-5/16" [110mm]

2" [51mm]

3-9/32" [84mm] X=2-11/16" [69mm]

4-5/16" [110mm]

Normal Beam, 1 or 2 Lamp X

29/32" [24mm]

3-3/8" [86mm]

9-1/16" [231mm]

29/32" [24mm]

3-11/32" [85mm] X=2-11/16" [69mm]

7-9/16" [193mm]

7-3/32" [181mm]

System Performance Table

Wattage

Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh

MB-232-FB-EB81

2

3100

94%

95%

1.00

5542

1.95

1.40

7740

56

$2.43

MB-154T5-FB-UNV-EBT1

1

5000

93%

98%

1.00

4543

1.90

1.38

6262

65

$3.40

50

8TMB-232-FB-EB81

4

3100

94%

95%

1.00

11073

1.95

1.40

15502

109

$2.44

64

(2) 34W T12 Strip

2

2750

88%

90%

0.90

3920

1.50

1.22

4801

126

$10.37

19

(1) 96" T12HO Strip

1

8630

58%

90%

0.88

3964

1.50

1.22

4855

145

$12.07

25

MB System Comparison

No. of Lamps

Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4

TER5

63

Comparison System

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data. 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor. 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA. 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^.0.5. 5 TER (Target Efficacy Rating) is calculated in accordance with NEMA standard LE 6 – 2008.

25

1-7/16" [37mm]

X

X=2-11/16" [69mm]

8-5/8" [220mm]

X 2" [51mm]

Task Beam, 1 or 2 Lamp

X

1-1/8" [29mm]

5-11/16" [145mm]

7-7/32" [184mm]

Focus Beam, 2 Lamp

Focus Beam, 1 Lamp

T8 Lamp Configurations

(8’) 96" [2438mm]

3-9/32" [84mm]

5-7/8" [150mm]

X=2-11/16" [69mm]

(8’) 91-3/4" [2330mm]

(4’) 48" [1220mm]

X 1" [26mm]

2" [51mm] 1" [26mm]

(4’) 43-3/4" [1112mm]

Task Beam, 2 Lamp

Task Beam, 1 Lamp

X 3-9/32" [84mm]

1-3/4" x 3-1/4" K.O. (1) Ground Screw Bump

Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10



||

112 101 92 84 76 70 65 60 56 52 49

112 97 84 73 65 58 52 47 43 40 37

MB-132-NB-UNV-EB81 Electronic Ballast (1) 32WT8 Lamp 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height Efficiency 94% Test Report: 10267

112 112 92 88 77 71 65 59 56 50 49 43 43 37 39 33 35 29 32 26 29 24

105 90 78 69 61 55 49 45 41 38 35

105 87 73 62 54 47 42 38 34 31 28

Coefficients of Utilization 20%

105 84 69 57 49 42 37 32 29 26 24

30% 50 30 10 100 87 75 66 59 53 48 44 40 37 34

100 84 71 61 53 46 41 37 34 31 28

100 81 67 56 48 41 36 32 29 26 24

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 722 1133 2012 2679

%Lamp 25.3 39.8 70.6 94.1

%Fixture 26.9 42.3 75.0 99.9

||

Part Number

2 LAMP T12

1 LAMP T12 HO

2 LAMP T12

1 LAMP T12 HO

2 LAMP T12

1 LAMP T12 HO

56%

61%

48%

55%

56%

61%

38%

37%

23%

22%

38%

37%

MB-232-FB-EB81

MB-154T5-FBEBT1

8TMB-232-FBEB81

T8

T5

T8

% Light gain/light loss utilize S/P adjusted lumens.

Ordering Information

Blank=4' Length 8T=8' Tandem Length Series MB= Micro-Bay Number of Lamps 1=1 Lamp 2=2 Lamps

113 102 93 84 77 70 65 60 56 53 49

113 97 84 73 65 58 52 47 43 40 37

113 113 93 89 77 71 65 59 56 49 49 42 43 37 39 33 35 29 32 26 29 24

106 91 79 69 61 55 49 45 41 38 35

106 88 73 62 54 47 42 37 34 31 28

20% 30% 50 30 10

106 85 69 57 48 42 36 32 29 26 24

101 87 76 66 59 53 48 43 40 37 34

101 84 71 61 53 46 41 37 33 30 28

101 82 67 56 48 41 36 32 29 26 23

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 700 1104 2001 2707

%Lamp 24.6 38.7 70.2 95.1

%Fixture 25.8 40.7 73.8 99.9

Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

77°F (25°C)

% Light Gain/Loss

Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10

MB-132-TB-UNV-EB81 Electronic Ballast (1) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.0 x mounting height Efficiency 95% Test Report: 10266

MB System Performance

Energy Savings

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

115 108 101 95 88 82 77 72 67 62 58

MB-132-FB-UNV-EBT1 Electronic Ballast (1) 32W T8 Lamp, 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 0.5 x mounting height Efficiency 96.8% Test Report: 09363

115 105 96 87 79 72 66 61 56 51 47

115 115 102 99 91 87 81 76 73 68 65 60 59 54 64 49 49 44 44 39 40 36

108 99 91 83 76 69 64 59 54 49 46

108 97 87 78 71 64 58 53 48 43 40

20%

108 95 84 75 66 59 53 48 43 39 35

30% 50 30 10 103 95 88 81 74 68 62 57 53 48 45

103 94 85 77 69 63 57 52 47 43 39

103 92 82 73 66 59 53 48 43 39 35

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90

Lumens 1251 1758 2535 2759

%Lamp 43.9 61.7 88.9 96.8

%Fixture 45.3 63.7 91.9 100.0

Sample Number: MB-154T5-FB-UNV-EBT1-U

Voltage UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (8) Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (2) (see pg. 27)

Lamp Types 32=32W T8 Lamp 54T5=54W T5HO Lamp Reflector FB=Focus Beam TB=Task Beam (Medium) NB=Normal Beam NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Voltage to be specified with emergency ballast option.(3) Voltage must be specified when ordered with plugs, motion or emergency ballasts. (4)Cannot be combined with PI/CPI option. See below. (5) 2 lamp ballast configurations only in UNC versions. (6) Not for use in high abuse applications such as gymnasiums. (7) Must ship as accessory separately. (8) UNC option available on select T8 ballast systems. Consult factory. (9) Dimming ballasts not recommended for use at temperature < 0°F (-18°C).

Ballast Type (1) T5 Systems EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10%(5) No. of Ballast 1 or 2 EHT =T5 Linear Electronic Program Rapid Start High Ambient. Total Harmonic Distortion < 10%(5) No. of Ballast 1 or 2 DIM=Consult Factory (9) T8 Systems (8) EB8 =T8 Electronic Instant Start. (5) Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start.(5) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 DIM=Consult Factory (9)

Options PI/CPI=Plug-In (1, 2 or 3) Specify Circuit

Packaging U=Unit Pack

(see PI Ordering Information on pg. 30)

C3=3' Power Cord (4) C6=6' Power Cord (4) PC3-=3' Power Cord & Plug(3), (4) (Specify Voltage)

PC6-=6' Power Cord & Plug(3), (4) (Specify Voltage)

Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (6) Y- TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30') SINGLE-TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30') MB-EXT-LONG-CONN-KIT-U= Rigid Connector Support for Continuous Channel Installation MS=180˚ Aisle Coverage Motion Sensor (3), (7) MSO=360˚ Coverage Motion Sensor (3), (7) MB-SENSOR-KIT-CTR/MT-U=Aisle Coverage Motion Sensor, Center Mount Hardware, 120/277V MB-SENSOR-KIT-END/MT-U=Aisle Coverage Motion Sensor, End Mount Hardware, 120/277V MB-SENSOR-KIT-CTR/480V-U=Aisle Coverage Motion Sensor, Center Mount Hardware, 480V MB-SENSOR-KIT-END/480V-U=Aisle Coverage Motion Sensor, End Mount Hardware, 480V

26

Emergency Options

Lamp Options Brand

Lamp

HB/2HB

VT3 (1)

MB(1)

HBHD

Generic

L8830

X

X

X

X

L8835

X

X

X

X

L8841

X

X

X

X

L8850

X

X

X

X

L5830

X

X

X

X

X

L5835

X

X

X

X

X

L5841

X

X

X

X

X

L5835

X

X

X

X

X

L8835C

X

X

L8841C

X

X

L8850C

X

X

L5835C

X

X

L5841C

X

X

L5850C

X

L8835HL (3100 lamps)

X

X

X

X

X

L8841HL (3100 lamps)

X

X

X

X

X

L8850HL (3000 lamps)

X

X

X

X

X

LGSP30M/OC8 (GE)

X

X

X

X

GE

AB

Nomenclature

Description

HB/2HB

VT3

MB

HBHD

Generic

EL4 (350-450 Im) EL5 (500 Im) EL5HO (700-800 Im) EL8 (600-700 Im)

X X X X

X X X X

X X X X

X X X X

Sure-Lites

EL-FBP140X (350-450 Im) EL-FBP240U (600-700 Im) EL-FBP240M (600-700 Im) EL-FBP240H (1100-1400 Im)

X X X X

X X X X

X X X X

X X X X

Bodine

EL-B100 (350-450 Im) EL-B90 (500-600 Im) EL-B70A (600-700 Im) EL-B60 (600-700 Im) EL-B60U (600-700 Im) EL-B50 (1100-1400 Im) (1) EL-B50U (1100-1400 Im) (1) EL-B50ST (1100-1400 Im) (1) EL-B50RCT (1100-1400 Im) (1) EL-I32 (up to 550 Im) EL-I40 (up to 700 Im) EL-I48 (up to 700 Im) EL-I320 (1300 Im) (1) EL-I880 (2000 Im) (1) EL-I232 (2 @ 1400 Im) EL-ISD80 (1300 Im) (1) (2) EL-I40DL (up to 700 Im) (2) EL-I48DL (up to 700 Im) (2) EL-I80DL (1300 Im) (2) EL-I232DL (2 @ 1400 Im) (2)

X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X

X

LGSP35M/OC8 (GE)

X

X

X

X

LGSP41M/OC8 (GE)

X

X

X

X

LGSPX30M/OC8 (GE)

X

X

X

X

LGSPX35M/OC8 (GE)

X

X

X

X

LGSPX41M/OC8 (GE)

X

X

X

X

LGF28T5M/830 (GE)

X

X

LGF28T5M/835 (GE)

X

X

LGF28T5M/841 (GE)

X

X

X

X

LGF54T5M/830 (GE)

X

X

X

X

X

LGF54T5M/835 (GE)

X

X

X

X

X

LGF54T5M/841 (GE)

X

X

X

X

X

F32 T8SPX35ECOCVG

X

X

F32 T8SPX41ECOCVG

X

X

F32 T8SPX50ECOCVG

X

X

F32 T8XLSPX41HCVG

X

X

Iota

LGF24T5M/841 (GE)

Philips

Sylvania

27

NOTES:

(3)

X X

NOTES: (1) For battery wired to two lamps, specify “/2L” after battery description. (2) Approved for wet location listing. (3) Consult factory for emergency options for Arctic Bay series.

F-Bay Mounting Accessories HB/2HB

AB

MB

X

X

X

F32 T8XLSPX50HCVG

X

X

AYC

F54 T5835HOECOCVG

X

X

TCB/STEM

X

X

F54 T5841HOECOCVG

X

X

TCB/RH-1

X

X

F54 T5850HOECOCVG

X

X

TCB/FH-1

X

LWF32T8M/TL730 (Philips)

X

X

TCB/FL-1

X

X

LWF32T8M/TL735 (Philips)

X

X

LWF32T8M/TL741 (Philips)

X

X

HB-SPS

X

X

LWF32T8M/TL830 (Philips)

X

X

X

X

LWF32T8M/TL835 (Philips)

X

X

X

X

X

X

LWF32T8M/TL841 (Philips)

X

X

X

LWF28T5M/830 (Philips)

X

X

X

LWF28T5M/835 (Philips)

X

X

X

LWF28T5M/841 (Philips)

X

X

LWF54T5M/830 (Philips)

X

X

X

X

X

LWF54T5M/835 (Philips)

X

X

X

X

X

LWF54T5M/841 (Philips)

X

X

X

X

X

LSFO32M/730K (OSI)

X

X

LSFO32M/735K (OSI)

X

X

LSFO32M/741K (OSI)

X

X

LSFO32M/830K (OSI)

X

X

X

X

LSFO32M/835K (OSI)

X

X

X

X

LSFO32M/841K (OSI)

X

X

X

LSF28T5M/830 (OSI)

X

X

X

LSF28T5M/835 (OSI)

X

X

X

LSF28T5M/841 (OSI)

X

X

LSF54T5M/830 (OSI)

X

X

X

X

X

LSF54T5M/835 (OSI)

X

X

X

X

X

LSF54T5M/841 (OSI)

X

X

X

X

X

(1) Lamps

supplied, not installed.

SINGLE TOGGLE “Y” TOGGLE

X X

X

X

X

X

Packaging Options HB/2HB

AB

VT3

MB

U

Unit Pack

X

X

X

X

PAL

Palletized out of carton on a 25" x 48" pallet, shrink wrapped

X

X

PALC

Palletized in carton on a 25" x 48" pallet, shrink wrapped

X

X

Nomenclature Description

NOTES:

(3) Pallet

size is 40" x 58".

HBHD

X X

X

X

HB/2HB Lens, Door Frames and Wireguards

HB/2HB LENS & DOOR FRAME

D E S I G N AT I O N

PRISMATIC & CLEAR ACRYLIC LENS & DOOR FRAME

HB-FRM/LENS PK= Prismatic Acrylic Lens & Door Frame for HB (use with general distribution reflector) 2HB-4-A W/FRM PK= Prismatic Acrylic Lens & Door Frame for 2HB (use with general distribution reflector) HB-FRM/CL PK= Clear Acrylic Lens & Door Frame for HB 2HB-FRM/CL PK= Clear Acrylic Lens & Door Frame for 2HB HB-FRM/LENS/G2 PK= Prismatic Acrylic Lens & Door Frame with Gasket for AB HB-FRM/CL-G2 PK= Clear Acrylic Lens & Door Frame with Gasket for AB 2HB-FRM/LENS-G2 PK= Prismatic Acrylic Lens & Door Frame with Gasket for 2AB 2HB-FRM/CL-G2 PK= Clear Acrylic Lens & Door Frame with Gasket for 2AB

HB/2HB LENS & WIREGUARD

WIREGUARD

D E S I G N AT I O N

HB-FRM/WG PK (1) = Frame and Wireguard for HB 2HB-FRM/WG PK (1) = Frame and Wireguard for 2HB HB-FRM/LENS/WG PK (1) = Frame and Prismatic Acrylic Lens with Wireguard for HB 2HB-FRM/CL/WG PK (1) = Frame and Clear Lens with Wireguard for 2HB

NOTE: (1) Not for use with Arctic Bay.

HB/2HB DROP WIREGUARD

DROP WIREGUARD

D E S I G N AT I O N

HB-FRM/DROPWG PK (1) = Frame and Drop Wireguard for HB 2HB-FRM/CL/DROPWG PK (1) = Drop Wireguard, Clear Acrylic Lens and Door Frame for 2HB 2HB-FRM/LENS/DROPWG PK (1) = Drop Wireguard, Prismatic Acrylic Lens and Door Frame for 2HB 2HB-FRM/DROPWG PK (1) = Drop Wireguard and Door Frame for 2HB

NOTE: (1) Not for use with Arctic Bay.

H B / 2 H B H E AV Y D U T Y W I R E G U A R D

D E S I G N AT I O N

HEAVY DUTY WIREGUARD

SWG/2HB-4FT-B= Heavy Duty Wireguard for field installation, 2HB only SWG/HB-4FT-B= Heavy Duty Wireguard for field installation, HB only

28

F-Bay Occupancy Sensors (Not for use below 32°F (0°C)) SENSOR

D E S I G N AT I O N

DESCRIPTION

CPD-1200H

MS= 180° Aisle Coverage Occupancy Sensor (120V/277V) (1)

CPD-1200 Aisle Coverage Occupancy Sensor (120V/277V) (Rectangular Beam Pattern Coverage)

600' sq. ft.

40' Height

MMS-CPD1200H= MS Motion Sensor for Modular Power Supply Option (120V/277V) (1) , (2)

Supplied with Mounting Box and Modular Power Supply Receptacle. 600' sq. ft. For use with MP option

E AT

PL

D

EN

X

X=Height 4-5/8" [118mm]

Width 4-5/8" [118mm] Length 4-5/8" [118mm]

NOTES: (1) One motion sensor per fixture required. (2) Not for use with Arctic Bay.

SENSOR

D E S I G N AT I O N

DESCRIPTION

CPD-500H

MSO= 360° Coverage Occupancy Sensor (120V/277V)(1)

CPD-500 360° Coverage Occupancy Sensor (120V/277V) (360° Circular Pattern Coverage)

Approximately 1250 sq. ft. @ 40 ft.

MMS-CPD500H= 360° MS Motion Sensor for Modular Power Supply Option (120V/277V) (1) , (2)

NOTES: (1) One Motion Sensor per fixture required. (2) Not for use with Arctic Bay.

29

Supplied with Mounting Box and Modular Power Supply Receptacle For use with MP option

Power Connections CORD & PLUG

DESCRIPTION

PC3, PC6

PC3 – 3' long Cord & Plug set w/NEMA L515 or L715 twist lock plug (white) PC6 – 6' long Cord & Plug set w/NEMA L515 or L715 twist lock plug (white) MPC3 (1) =3' long Modular Cord & Plug set w/NEMA L/515 or L715 twist lock plug - white. Use with MP option. MPC6 (1) =6' long Modular Cord & Plug set w/NEMA L/515 or L715 twist lock plug - white. Use with MP option.

NOTES: (1) Not for use with Arctic Bay.

CORD SETS

DESCRIPTION

C3, C6

C3 – 3' long 3/16 STW white Power Cord C6 – 6' long 3/16 STW white Power Cord MC3 (1) – 3' long 3/16" Standard Modular Power Cord. For use with MP option. MC6 (1) – 6' long 3/16" Standard Modular Power Cord. For use with MP option.

NOTES: (1) Not for use with Arctic Bay.

MODULAR WIRING

D E S I G N AT I O N

DESCRIPTION

MWS

MWS= Modular Wiring System

MWS is a simple and cost effective modular wiring system consisting of factory assembled components. MWS arrives at the job site ready to be snapped together into a complete branch circuit wiring system. With MWS, branch circuit wiring can be installed in minutes instead of hours. Reduces labor by 80% for lowest total installed cost. Fixtures and wiring are portable for future flexibility.

MDS6 (1) = 6' Modular Power Cord with MWS

27DS18/2G06MP Connect directly to F-Bay or Motion Sensor w/MP option

NOTES: (1) Not for use with Arctic Bay.

P I O P T I O N O R D E R I N G I N F O R M AT I O N

For use with continuous row mounted fixtures only.

Catalog Number Suffix

Number of Circuits

Circuit Wired To Ballast

PI 1 BLK PI 2 BLU PI 2 BLK

1 2 2

Black Blue Black

PI 3 RED PI 3 BLU PI 3 BLK

3 3 3

Red Blue Black

Catalog Numbering System The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows: PI-1 = One Circuit - 2 Wires: one black, one white PI-2 = Two Circuits - 3 Wires: one black, one blue, one white PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered separately if PI option is chosen.

PI1 - Single Circuit Plug-In

PI2 - Two Circuit Plug-In

PI3 - Three Circuit Plug-In

SAMPLE NUMBER: PI1BLK-WG

SAMPLE NUMBER: PI2BLK-WG

SAMPLE NUMBER: PI3BLK-WG

PI1= Single Circuit BLK=Black Hot

NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness)

PI2= Two Circuit

Leave Blank=Single Neutral 2NEU=Two Neutrals

BLK=Black Hot BLU=Blue Hot

NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness)

Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral

PI3= Three Circuit

Leave Blank=Single Neutral 2NEU=Two Neutrals

BLK=Black Hot BLU=Blue Hot RED=Red Hot

NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness)

Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral

30

Mounting MOUNTING ACCESSORIES

D E S I G N AT I O N

DESCRIPTION

Top Connector Box

TCB= Top Connector Box (Includes Plate) TCBP= Top Connector Box Plate (Mounted on fixture) HB-TCB-KIT-U= Complete TCB Kit (Supplied Separately) HB-TCB-KIT-NO-PLATE-U= Kit for Fixture w/TCBP Installed

Suitable for conduit mounting or for use with fixture hook, loop or safety hook. Use chain or cable set to meet NEC requirements for single point mounting, as well as to prevent cantilevering and rotation of fixture from one central location. Ideal for Retrofit opportunities!

Side

X

Front

4-11/16" [120mm]

3-9/16" [91mm]

Top

2-5/16" [59mm]

X=3/4" [20mm]

2-11/32" [60mm] 4-11/16" [120mm]

MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

Hook and Safety Hook

FH–1= Fixture Hook

Fixture Hook 2-1/2" (must be used with TCB) Top

3-3/8" [86mm] 1-1/2" HEX. [39mm]

1-7/8" [48mm]

1-3/16" [31mm]

MOUNTING METHODS

1" [26mm]

D E S I G N AT I O N

DESCRIPTION

FL–1= Fixture Loop

Fixture Loop 2-1/2" (must be used with TCB)

MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

Retrofit Hanger

RH–1= Retrofit Hanger

Cast Aluminum Hanger w/Toggle Nut & Carriage Bolt for quick installation (must be used with TCB)

MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

Stem

Accessories (order separately) – = Stem Set (Order Two Per Fixture) SC

Fixed, swivel or adjustable stem sets are available in various lengths.

Loop

Length: 6", 8", 12", 24", 36", 48", 60", 72") F=Fixed S=45° Swivel A=Adjustable (48" Only)

31

Mounting MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

AYC Chain Set

AYC–CHAIN/SET–U=Mounting chain set

(3)

(2) sturdy Wire Hooks and 36" Chain Sets w/S-hooks

Note: Not for use in high abuse areas such as gymnasiums or similar recreational facilities.

MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

“Y” Toggle

Y–TOGGLE–10=Mounting Toggle and 10' Cable

10', Y Toggle #2 Cable

Y–TOGGLE–25=Mounting Toggle and 25' Cable

25', Y Toggle #2 Cable

MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

Loop Hanger/Single Toggle

LOOP–TOGGLE–10

10' Loop Hanger #2 Cable

LOOP–TOGGLE–30

30' Loop Hanger #2 Cable

SINGLE–TOGGLE–10

10' Single Toggle #2 Cable

SINGLE–TOGGLE–30

30' Single Toggle #2 Cable

Loop Hanger

Single Toggle

MOUNTING METHODS

D E S I G N AT I O N

DESCRIPTION

SPS Cable Kit

HB–SPS

Cable Kit (2)= Stainless Steel Cable Kit for single point suspension. Fixture dropped below mounting point by 13". If used in two point configuration, fixture drop will be 29" below mounting point.

SINGLE POINT

(1) (2)

TWO POINT

Note: Not for use in high abuse areas such as gymnasiums or similar recreational facilities. NOTES:

(1) Only

one required per fixture. (2) Fixture Hook not included.

32

Programs & Tools

We Light You Cooper Lighting’s advanced lighting and control systems enable comprehensive energy programs to maximize energy efficiency and contribute to your company’s sustainability initiatives. Because seeing is believing, Cooper Lighting’s We Light You program allows up to 90 days delayed billing from acceptance of delivery to measure the visible and energy saving results.

Here’s How It Works... • Select an approved fixture style: • 2AB-654T5-UNV-L5850-EBTL2-U • AB-454T5-UNV-L5850-EBTL1-U • VT3-254T5DR-UNV-EBT1-WL-U (standard lead times apply) • Enter an order for up to six approved F-Bay fixtures with your Local Cooper Lighting Representative. • Order must be marked “We Light You”. • Install the fixture in your facility and measure the visible results of Cooper Quality Lighting. • Cooper Lighting will allow up to 90 days delayed billing from acceptance of delivery, or return the fixture, freight prepaid, within 90 days and receive no invoice.

Cooper Lighting’s sample demonstration program, “We Light You”, offers risk-free trial installation.

Cold Storage Distribution Facility, California When a California cold storage facility wanted to reduce their energy consumption they turned to a local contractor for advice on a lighting system upgrade. With an installed lighting system of over (100) 400W high pressure sodium high bays, the contractor selected Cooper Lighting’s T5HO Arctic bay. “T5 is reliable in very cold conditions, still provides quality light and allows cold storage facilities to save valuable energy without compromising their ability to see”, states the installing contractor. The 6 lamp T5HO Arctic Bay with occupancy sensors provided 45% energy savings. Since the occupancy sensors rotate between the 4 and 2 lamps, it helps maximize lamp life reducing maintenance costs. The fluorescent system also has higher 85 CRI compared to high pressure sodium’s 22 CRI which provided the appearance of significantly more light although the footcandles are roughly the same, recounts the contractor. In addition to the energy savings, the facility was able to take advantage of the local utility’s rebate program sweetening the overall payback less than one year – 11 months.

Before: (111) 400W HPS 464 Input Watts Per 412,398 kWh After: (111) 6L 54W T5HO Arctic Bay 351 Input Watts Per (234 4L, 117 2L) Rotating Occupancy Sensors 163,286 kWh

“The reaction has been very positive, workers love the light and ownership values the savings.”

Energy efficient lighting system upgrade reduces energy consumption 45% providing an 11 month payback.

Cold & Refrigerated Storage Energy Efficiency Tool Kit The customized tool kit includes calculators, lighting design recommendations, audit tools and tips to help make informed decisions when considering an energy efficient and sustainable lighting system for cold and refrigerated storage areas. Visit www.cooperenergysolutions.com for a free download!.

33

34

Cooper Lighting, LLC. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269

International Sales, USA Cooper Lighting, LLC. 1121 Highway 74 South Peachtree City, GA 30269

P: 770-486-4800 F: 770-486-4801

P: 770-486-4800 F: 770-486-4801

www.cooperlighting.com

Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049

Domestic Facilities Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia

Canadian Facilities Calgary, Alberta T2E 7V9

Cooper Lighting is a valuable trademark of Cooper Industries in the United States and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com

ACF080337

Printed in USA

The Cooper Lighting Family Halo Metalux Lumark Sure-Lites Neo-Ray Corelite Portfolio IRiS Shaper io Lumière Invue McGraw-Edison Streetworks Fail-Safe PDS MWS RSA Ametrix