Development of an automated double-ring infiltrometer

27 downloads 94852 Views 298KB Size Report
Email: b.maheshwariQuws.edu.au. Abstract. A double-ring infiltrometer is often used for ... inner and outer rings and the infiltrometer is far from being automated.
Aust. J. Soil Res., 1996, 34, 709-14

Development of an automated double-ring infiltrometer B. L. Maheshwari School of Agriculture and Rural Development, University of Western Sydney, Richmond, NSW 2753. Email: b.maheshwariQuws.edu.au

Abstract

A double-ring infiltrometer is often used for measuring infiltration characteristics in the field, but the measurements are time-consuming and tedious, especially when several tests are to be monitored at a site. This is because the infiltrometer in its present form requires continuous attention and therefore limits the number of tests that can be monitored a t a site in a given time. An automated double-ring infiltrometer has been developed to overcome these limitations. It consists of inner and outer rings, water level sensors, water container, depth sensor, solenoid valves, 12-volt car battery, laptop computer, and software to perform recording and basic analysis of the infiltration data. The infiltrometer requires little attention once the test is started and the computer provides upto-the-minute summary of infiltration results while the test is still in progress. The automated infiltrometer worked very satisfactorily during the field trials and has considerable potential as a research and teaching tool. Additional keywords: infiltration measurement, soil-water movement.

Introduction Ring infiltrometers are commonly used for in situ measurement of infiltration characteristics. The infiltrometer can employ 1 or 2 concentric rings, and correspondingly it is called a single- or double-ring infiltrometer. The double-ring infiltrometer is preferred because the outer ring helps in reducing the error that may result from lateral flow in the soil. Several researchers (e.g. Burgy and Luthin 1956; Bouwer 1963; Tricker 1978) have studied the effects of ring diameter and depth of water ponded in the rings on the reliability of infiltration measurement.

Why automate the ring infiltrometer? In a ring infiltrometer test, a constant depth of water should be maintained in the rings and the volume of water infiltrated with time must be recorded during the test. This means that continuous attention is required during the test and the measurement with the infiltrometer is time-consuming and tedious, especially if it is to be done at several sites requiring replications. Due to considerable effort and time required in setting up the infiltrometer in the field, it is desirable to check trends and accuracy of infiltration characteristics being measured while the test is in progress. Then, if there is any problem in the measurement, some remedial action can be taken to obtain correct data. To overcome the above difficulties and limitations, efforts have been made in the past with limited success to automate the measurement. In particular, Constantz and Murphy (1987) developed a single-ring infiltrometer with an automated Mariotte reservoir, which enables automatic recording of flow from the reservoir, but its use for a double-ring infiltrometer still requires water level control in both

B. L. Maheshwari

inner and outer rings and the infiltrometer is far from being automated. Ankeny et al. (1988) modified the set-up of Constantz and Murphy for use as a 'tension infiltrometer' which is used for estimating sorptivity and unsaturated hydraulic conductivity and is very different from a conventional double-ring infiltrometer. The set-up reported by Prieksat et al. (1992) is based on work of Constantz and Murphy (1987) and Ankeny et al. (1988) and uses pressure transducers for determining water flow out of the Mariotte reservoir. The set-up is a kind of single-ring infiltrometer with a small ring (102 mm diameter) and cannot be modified from its present design for use as a double-ring infiltrometer. The double-ring infiltrometer of Matula and Dirksen (1989) requires 2 water containers, one each for inner and outer rings, and the water level in the inner ring is controlled through an arrangement of a float and photosensitive transistor, but the elapsed time is recorded manually. This means that their set-up is only semi-automatic and the infiltration measurement cannot be automated fully. In summary, no set-up has yet been reported that is capable of measuring infiltration without continuous attention during the test and at the same time providing up-to-the-minute summary of the infiltration data.

Automated ring infiltrometer Recognising the limitations of a manual infiltrometer, a fully automatic set-up needs t o be developed to enable ( i ) a precise control of water depths in the inner and outer rings, (ii) an automatic addition of a measured volume of water when required, and ( i i i ) a summary of infiltration test results available a t any time during the test. The summary may include the current and past information on the volumes of water added during refills, infiltration rates, and cumulative infiltration depths with elapsed time. Such a set-up is expected t o make monitoring of tests less demanding and will provide a quick in situ check on the progress of the data. The set-up will be particularly useful in a study that involves infiltration measurement a t several sites requiring replications. Besides its use for research, an automated ring infiltrometer will also be an excellent teaching tool t o show trends in infiltration characteristics and discuss some of the issues with the students while a t the test site.

Materials and methods Design of an automated ring infiltrometer While general details on ring infiltrometers are given in Bouwer (1986), Fig. 1 shows schematically an arrangement of different components of an automated double ring infiltrometer. The inner and outer cylindrical rings are inserted into the ground. These rings are fiIIed with water and infiltration occurs through the ground area enclosed by the rings. A constant depth of water within each ring is maintained through an arrangement of water supply from a storage tank, solenoid valve, and a water level sensor. When the water level in a ring drops below 5 mm from a pre-set value, the level sensor sends a signal to the computer which in turn instructs the solenoid valve to open and allows water from the tank to flow into the ring. The water flow stops when the level reaches the pre-set value in the ring, again through a signal from the level sensor (via the computer) to the solenoid valve. Between the inner and outer rings, the inner ring is given priority in re-filling of rings as this ring is more crucial for the infiltration measurement. The volume of !?ow from the storage tank into the inner ring is calculated by measuring change in water depth in the storage tank with time when the solenoid supplying water to the inner ring is opened. The depth in the tank is measured by a depth sensor and transmitted

Development of aautomated double-ring infiltrometer

Infiltration

Fig. 1. Experimental arrangement in the field. to a laptop computer. The tank needs to be calibrated for the relationship between water depth and volume it occupies in the tank. The calibration needs to be done only once for a given tank. The data on volume of water added and elapsed time are continuously analysed and plotted on the screen, and thus provide current state of infiltration in the test. The main information displayed on the screen includes cumulative infiltration depth, current and average infiltration rate, time elapsed since beginning of test and last refill of inner ring, and a plot of cumulative infiltration depth with elapsed time.

Details of infiltrometer components Software As a part of this development, user-friendly software was developed for smooth operation of the infiltrometer. The software is written in BASIC and is available from the author upon request. At the beginning of the test, the software enables convenient recording of identification details of the test, calibration of the storage tank, testing of solenoid valves to check whether they are operating properly, and filling of the rings to a required depth. During the test, it helps in storage and analysis of data, updated display of test results, and termination of test if desired. The software also keeps track of elapsed time since beginning of test and times when refills of the inner ring occur. Furthermore, when the water level in the tank drops too low, it will generate a beeping sound to alert that it is now time to refill the tank. At this time, by pressing an appropriate key in the computer, the next refill of the rings can be suspended to enable refilling of the tank. If there is no-one around to refill the tank, the computer will automatically conclude the test and store all the data collected.

Cylindrical rings The inner and outer rings have diameters of 300 and 500 mm, respectively, and a height of 500 mm. The rings are constructed of 3-mm-thick galvanised iron sheet so that they do not deform when inserting them into the ground. The bottom of each ring has a bevelled edge to prevent soil disturbance while the top 50 mm is reinforced with a metal strip to withstand heavy force of hammering during insertion.

Water level sensors Two water level sensors, one each in the inner and outer rings, are used for maintaining appropriate depths of water in the rings. The level sensor consists of 3 electrodes called common, upper water level, and lower water level electrode. The electrodes are housed in a

B. L. Maheshwari

50-mm-diameter and 70-mm-long Perspex tube (see Fig. 2). One end of each electrode has an electrical lead that is connected to an electronic interface. In addition, the other ends of the upper and lower water level electrodes have a pointed tip to indicate precisely the water level in the rings. The interface mentioned above is a control circuit between the laptop computer and the level sensors, depth sensors, and solenoid valves, and its function is to process signals coming out of the sensors and solenoid valves and transmit them to the computer. The upper level electrode is vertically adjustable with the help of a thread provided on the top half of its length, whereas the lower level electrode is fixed in the Perspex tube. This means that the vertical clearance between the upper and lower electrodes can be changed easily, and the number of refills of the inner ring per unit time can be varied depending upon the infiltration characteristics of soil a t the experimental site. Field tests showed that a clearance of 5 mm is generally satisfactory for the soils considered in the present study. Elecmcal leads

Fig. 2. Construction details of a water level sensor.

The sensor works on the principle of completing or not completing the electric circuit between the common and other 2 electrodes. The water between the electrodes acts as the conducting medium. As the water level in the ring drops due to infiltration, a break in the electric circuit between the common and the lower level electrodes occurs a t some stage and sends a signal to the computer to start adding water to the ring to raise the water level. On the other hand, as the water level rises due to the addition of water to the ring, a stage is reached when the water level just touches the tip of the upper level electrode and completes the electric circuit between the common and the lower level electrodes; this sends a signal to the computer to stop adding further water to the ring. The cycle of completing and breaking of the circuits occurs throughout the test and enables precise control of water levels in the rings. The water level in a ring will fluctuate vertically between the tips of the upper and lower level electrodes.

Other components

A cylindrical plastic container with a tap a t the lower end is used for supplying water t o the rings. The size of the container should be such that it requires no more than 1 or 2 refills to complete a test and allows easy transport to the field site. A container of 30 L capacity will generally be suitable for most field conditions except for those with high infiltration rates. A commercially available depth sensor of capacitance type (Unidata model 6521) was used for measuring water depth in the storage tank. The electronic interface designed was such that it enabled the depth sensor to detect very small drops (