ISA Transactions 52 (2013) 140–148

Contents lists available at SciVerse ScienceDirect

ISA Transactions journal homepage: www.elsevier.com/locate/isatrans

Diagnosis of broken-bars fault in induction machines using higher order spectral analysis L. Saidi a,b,n, F. Fnaiech a, H. Henao b, G-A. Capolino b, G. Cirrincione b a b

Universite´ de Tunis, Ecole Supe´rieure des Sciences et Techniques de Tunis, SICISI, 5 avenue Taha Hussein, BP 96, Montfleury, 1008 Tunis, Tunisie University of Picardie ‘‘Jules Verne’’, Department of Electrical Engineering, 33 rue Saint Leu, 80039 Amiens cedex 1, France

a r t i c l e i n f o

a b s t r a c t

Article history: Received 30 November 2011 Received in revised form 18 July 2012 Accepted 15 August 2012 Available online 21 September 2012 This paper was recommended for publication by Jeff Pieper

Detection and identification of induction machine faults through the stator current signal using higher order spectra analysis is presented. This technique is known as motor current signature analysis (MCSA). This paper proposes two higher order spectra techniques, namely the power spectrum and the slices of bispectrum used for the analysis of induction machine stator current leading to the detection of electrical failures within the rotor cage. The method has been tested by using both healthy and broken rotor bars cases for an 18.5 kW-220 V/380 V-50 Hz-2 pair of poles induction motor under different load conditions. Experimental signals have been analyzed highlighting that bi-spectrum results show their superiority in the accurate detection of rotor broken bars. Even when the induction machine is rotating at a low level of shaft load (no-load condition), the rotor fault detection is efficient. We will also demonstrate through the analysis and experimental verification, that our proposed proposed-method has better detection performance in terms of receiver operation characteristics (ROC) curves and precision-recall graph. & 2012 ISA. Published by Elsevier Ltd. All rights reserved.

Keywords: Broken rotor bars Bi-spectrum analysis No-load condition Motor current signature analysis (MCSA) Receiver operating characteristic (ROC)

1. Introduction For several decades both correlation and power spectrum (PS) have been most significant tools for digital signal processing (DSP) applications in electrical machines diagnosis area. The information contained in the PS is sufficient for a full statistical description of Gaussian signals. However, there are several situations for which looking beyond the autocorrelation of a signal to extract the information regarding deviation from Gaussianity and the presence of phase relations is needed. Higher order spectra (HOS), also known as polyspectra, are spectral representations of higher order statistics, i.e., moments and cumulants of third order and beyond. HOS can detect deviations from linearity, stationarity or Gaussianity in any signal [1,2]. Most of the electrical machines signals are non-linear, non-stationary and non-Gaussian in nature and therefore, it can be more interesting to analyze them with HOS compared to the use of second-order correlations and power spectra. In this paper, the application of HOS on stator current signals for different rotor broken bars fault severities and shaft load levels has been discussed. So far, the large usage of induction machines (IM) is mainly due to their robustness, to their power efficiency and to their

n Corresponding author at: Universite´ de Tunis, De´partement de Ge´nie Electrique, Ecole Supe´rieure des Sciences et Techniques de Tunis, SICISI, 5 avenue Taha Hussein, BP 96, Montfleury, 1008 Tunis, Tunisie. Tel.: þ 216 22169567; fax: þ 216 72486044. E-mail address: lotfi[email protected] (L. Saidi).

reduced manufacturing cost. Therefore, the necessity for the increasing reliability of electrical machines is now an important challenge and because of the progress made in engineering, rotating machinery is becoming faster, as well as being required to run for longer periods of time. By looking to these last factors, the early stage detection, localization, and analysis of faults are challenging tasks. The distribution of IM failures has been reported in many reliability survey papers [3–8]. These main faults include: (a) stator faults, which define stator windings open or short- circuits and stator inter-turn faults; (b) rotor electrical faults, including rotor winding open or short-circuits for wound rotor machines or broken rotor bars (BRB) or cracked end ring for squirrel cage machines; (c) rotor mechanical faults such as bearing damages, static or dynamic eccentricities, bent shaft, misalignment, and any load-related abnormal phenomenon [3]. Issues of preventive maintenance, on-line machine fault detection, and condition monitoring are of increasing importance [3–9]. During the last twenty years or so, there has been a substantial amount of research dealing towards new condition monitoring techniques for electrical machine and drives. New methods have been developed for this purpose [5]. Monitoring machine line current and observing the behavior in time-domain and frequency-domain characteristics, from healthy to faulty condition, has been always the first step of analysis. This technique is known as machine current signature analysis (MCSA). The MCSA technique has been widely used for fault detection and diagnosis and it is considered as the most popular not only

0019-0578/$ - see front matter & 2012 ISA. Published by Elsevier Ltd. All rights reserved. http://dx.doi.org/10.1016/j.isatra.2012.08.003

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

for electrical faults but also for mechanical faults. Moreover, it can easily detect machine faults by using only current sensors which are not really invasive. Other signals to be monitored could be stator voltages, instantaneous stator power, shaft vibration, stray flux, electromagnetic torque, speed, temperature, acoustic noise and much more [3–9]. Features extracted from one or more of these signals could be used as the fault diagnosis indexes. This paper focuses on BRB fault in IM which represent about 10% of total industrial induction motor faults [3], by using both spectral and bi-spectral analysis of the stator current. MCSA has been extensively used to detect BRB and end ring faults in IM [9–11]. The side-band frequency components at (172ks)fs have been used to detect such faults, (s is the rotor slip and fs is the fundamental supply frequency, and one integer k¼1, 2, 3, y). Although, the MCSA gives efficient results when the motor operates under rated or high load conditions, some drawbacks have been observed when the load shaft is light. Since the side-band frequency components (172s)fs are very close to the grid frequency fs, a natural spectral leakage can hide frequency components characteristics of the fault [12]. In this case, the standard MCSA method fails to detect BRB faults. This problem can be solved by increasing the sampling frequency but load variations during sampling may decrease the quality of the spectrum [9]. Hence a trade-off must be performed between spectrum leakage and frequency resolution which is difficult to be reached when using the Fast Fourier transform (FFT). Consequently, MCSA method is strongly dependent on the rotor slip condition and it has not been applied to BRB faults under no-load condition. Due to those limitations of FFT, in the literature other methods for spectral analysis become potential options to the detection of BRB such as the zoom-FFT (ZFFT) [9–11], in [11] a method based on the multiple signal classification (MUSIC) has been proposed to improve diagnosis of BRB fault in IM, by detecting a large number of frequencies in a given bandwidth. This method is called zoomMUSIC, wavelet approaches [13], neural network [14]. In those techniques, the computational time and the accuracy in a particular frequency range are increased. However, as expected, the frequency resolution is still affected by the time acquisition period and the load effect (especially no-load condition) was not studied. The analysis of faults at low slip is important in industrial applications and would provide the following benefits [12]:  Improving quality control of new motors,  Allowing no-load analysis of all type of motors,  Preventing confusion of faults with load-induced current oscillation,  Reducing the cost of fault analysis.

141

including machinery diagnosis for various mechanical faults [20]. Other applications include the usage of the bi-spectral analysis to detect the fatigue cracks in beams [21], stator inter-turn faults [22], and bearings [23]. It has been also used in the case of the coupling assessment between modes in a power generation system [19]. The application of HOS techniques in condition monitoring has been already reported [24,25] and it is clear that multi-dimensional HOS would contain more useful information than traditional twodimensional spectral analysis for diagnostics purposes. The next section will give a brief development of the basic bi-spectrum theory followed by a description of the experimental set-up. The third section will develop the PS and the bi-spectrum signal processing tools in order to characterize the stator current frequency components in presence of BRB. The last section will be dedicated to the analysis of experimental results, and ends with a comparison of the two higher order spectra techniques (PS and proposed BDS methods) by means of the ROC curves, before giving some conclusions on the implementation of this advanced DSP technique for electrical machines fault detection.

2. HOS analysis 2.1. Basic definitions In this section, the theoretical concepts of the bi-spectrum method will be recalled. Let us assume that: x(n), n ¼0, 1,y,N  1 is a discrete current signal, zero-mean and locally stationary random process with a length N. The autocorrelation function of a stationary process x(n) is defined by: Rxx ðmÞ ¼ EfxðnÞxðn þmÞg

ð1Þ

where E{.} is the expected mean operator (or equivalently the average over a statistical set) and m is a discrete time-delay. The PS is formally defined as the Fourier transform (FT) of the autocorrelation sequence: þ1 X

Pxx ðf Þ ¼

Rxx ðmÞ ej2pf m

ð2Þ

m ¼ 1

where f denotes the frequency. An equivalent definition can be given by: Pxx ðf Þ ¼ EfXðf ÞX n ðf Þg ¼ Ef9Xðf Þ2 9g

ð3Þ

n

where X denotes the complex conjugate of X and X(f) is the discrete Fourier transform (DFT) of x(n), given by: Xðf Þ ¼

N 1 X

2pf n N

xðnÞ ej

ð4Þ

n¼0

In this context, the MCSA method based on a Hilbert transform (HT) was used to detect BRB faults at very low rotor slip conditions [15]. The effectiveness of the method was confirmed by experimental data on an induction motor with one BRB fault. The performance of the method was not evaluated for different numbers of BRB. Besides this method requires high computation and large amount of data is required for the high frequency resolution. In another study [16], the HT is used to extract signal envelop and then the wavelet transform is applied to estimate fault index around 2sfs frequency component which reflects the energy variation of the phase current related to the BRB fault. The main drawback of this approach is that no clear methodology is proposed for the wavelet decomposition. Various DSP techniques [4–9] have been extensively used for feature extraction purposes and HOS has been one of them [17–24]. The bi-spectrum is the third order spectrum and it results in a frequency–frequency–amplitude relationship which shows coupling effects between signals at different frequencies [19]. This tool has already demonstrated its efficiency in many detection applications

where N is the number of samples. The third-order spectrum, called the bi-spectrum B(f1, f2) is defined as the double DFT of the third order moment. It can be defined as: Bðf 1 ,f 2 Þ ¼

þ1 X

þ1 X

2p

M x3 ðk,lÞWðk,lÞej N ðf 1 k þ f 2 lÞ

ð5Þ

k ¼ 1 l ¼ 1

where W(k, l) is a two-dimensional window function used to reduce the variance of the bi-spectrum and M x3 ðk,lÞ is the thirdorder moment of the process x(n), given by: Mx3 ðk,lÞ ¼ Efxn ðnÞxðn þ kÞxðn þlÞg

ð6Þ

where k and l are discrete time delays. As equivalence, Eq. (5) can be expressed in terms of the FT of x(n) as: Bðf 1 ,f 2 Þ ¼ EfXðf 1 ÞXðf 2 ÞX n ðf 1 þ f 2 Þg:

ð7Þ

142

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

It can be noted that the bi-spectrum presents twelve symmetry regions [1,2]. Hence, the analysis can take into consideration only a single non-redundant region. Hereafter, B(f1, f2) will denote the bi-spectrum in the triangular region T defined by: T ¼ ðf 1 ,f 2 Þ : 0 r f 2 r f 1 r f e =2, f 2 r 2f 1 þ f e , where fe is the sampling frequency. In order to minimize the computational cost, the direct method [1,2] has been used to estimate the bi-spectrum of a stator current signal as described in the following paragraph. 2.2. Bi-spectrum estimation In general, the expected values coming from Eqs. (3)–(7) need to be estimated from a finite quantity of available data. This may be achieved by dividing a signal into M overlapping segments with k as a subscript, k¼1, 2, 3,y,M. A windowing function has been applied to each segment and the FTs of all segments are averaged [1]. The aim is to reduce the variance of the estimate by increasing the number of records M [1,2]. ^ ,f Þ is given by: The estimated bi-spectrum Bðf 1 2 M X   ^ ,f Þ ¼ 1 Bðf X ðf ÞX ðf ÞX n ðf þ f 2 Þ  E Xðf 1 ÞXðf 2 ÞX n ðf 1 þf 2 Þ : 1 2 Mk¼1 k 1 k 2 k 1

ð8Þ The conventional PS concerns only the square of the magnitude of the Fourier coefficients and it cannot give information about phase coupling [1,2]. On the other hand, the bi-spectrum is complex and, therefore, it has magnitude and phase. The bi-spectrum or bicoherence (normalized bi-spectrum) based on HOS emphasizes the triple products of the Fourier coefficients and it is really able to provide such information. However, the computational cost is higher and the 3D-plot or the contours plots are very complex to describe as compared with that of the one-dimension [23,24]. In fact, it is impossible to compute the bi-spectrum from large data sets. On the other hand, by using smaller data sets, the estimation error will increase a lot [2]. The proposed method is directly computed in one-dimensional bi-spectrum diagonal slice (BDS) which condenses the 2D distribution into 1D curve. It requires less computation and it can be used in real time [22]. The BDS of a process x(n) can be obtained by setting f1 ¼f2 ¼f and it is defined as follows:  ^ ,f Þf ¼ f ¼ f ¼ Dðf ^ Þ  EfX 2 ðf ÞX n ð2f Þg Bðf ð9Þ 1 2 1 2

3. BRB faults diagnosis based on PS and BDS In this section, laboratory experiments have been used to verify the above HOS-based IM fault detection techniques. Two identical IM have been used to compare the results with one being healthy and the other one being faulty with rotor broken bars. 3.1. BRB fault It has been evaluated that rotor failures account about 10% of IM faults [3,4]. The objective of MCSA is to compute a frequency spectrum of the stator current and to recognize the frequency components which are distinctive of rotor faults. Eq. (10) gives the frequency components which are characteristic of BRB [3,4]:    k f BRB ¼ ð1sÞ 7 s f s ð10Þ p where fs is the supply frequency, p is the number of pole pairs, k is an integer and s is the rotor slip. By considering the speed ripple

effects, it was reported that other frequency components, which can be observed in the stator current spectrum, are given by [3,4]: f BRB ¼ ð1 7 2ksÞf s

ð11Þ

The side-band frequency components at (172s)fs has been used to detect such rotor faults. While the lower side-band is faultrelated, the upper side-band is due to consequent speed oscillations. It has been shown that the sum of magnitudes of these two sideband frequency components is a good diagnostic index given by [4]:      I Ir IdB ¼ 20log10 l þ 20log10 =2 ð12Þ I I where Il, Ir and I are the amplitude of the lower, upper side-band frequency components and of the fundamental frequency of the stator current, respectively.

3.2. Model of the BRB stator current A simple model which characterizes the IM stator current, with electrical rotor asymmetries includes the so-called sideband frequencies and it can be expressed by [11]: X ia ðtÞ ¼ if cosðotjÞ þ il,k cosððoof ,k Þtjl,k Þ þ

X

k

ir,k cosððo þ of ,k Þtjr,k Þ

ð13Þ

k

with fs as the fundamental frequency of the power grid. if is the fundamental value of the stator current amplitude (index f), o is its angular frequency, j is its main phase shift angle, of ,k ¼ 2kso, and il,k , ir,k and jl,k, jr,k (k¼1, 2, 3,y,) are the magnitude and the phase of the left (index l) and right (index r) sidebands components, respectively. As of ,k ¼ 2kso and o ¼ 2pf s , the expression (13) can be rewritten as: X il,k cosð2pf l,k tjl,k Þ ia ðtÞ ¼ if cosð2pf s tjÞ þ þ

X

k

ir,k cosð2pf r,k tjr,k Þ

ð14Þ

k

where fl,k ¼(1–2ks)fs and. fr,k ¼(1þ2ks)fs This simplified expression of the stator current signal has been used extensively for IM fault condition monitoring. By checking the magnitude of the side-band frequency components through the spectrum computation, various faults such as rotor bar breakage can be detected with a high level of accuracy [19]. From Eq. (14), the FT can be computed: Ia ðf Þ ¼

if 1X dðf 7 f s Þe 8 jj þ i dðf 7f l,k Þe 8 jjl,k 2 k l,k 2 þ

1X i dðf 7 f r,k Þe 8 jjr,k 2 k r,k

ð15Þ

where d(.) represents the Dirac delta function. By ignoring contributions at negative frequencies which fall outside the useful region of the bi-spectrum, Eq. (15) can be written as: Ia ðf Þ ¼

if 1X 1X dðf f s Þejj þ i dðf f l,k Þejjl,k þ i dðf f r,k Þejjr,k : k r,k 2 k l,k 2 2 ð16Þ

If the expression (16) is substituted in (7), the bi-spectrum becomes: Bðf 1 ,f 2 Þ ¼ Ia ðf 1 ÞIa ðf 2 ÞIa n ðf 1 þ f 2 Þ

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

0

1 P il,k1 dðf 1 f l,k1 Þejjl,k1 C k1 1B B C ¼ B P C A 8 @ þ ir,k1 dðf 1 f r,k Þejjr,k1 1 if dðf 1 f s Þejj þ

k1

P 1 il,k2 dðf 2 f l,k2 Þejjl,k2 k2 B C C B @ þ Pi dðf f Þejjr,k2 A r,k2 2 r,k2 0

if dðf 2 f s Þejj þ

k2

0

1 P il,k3 dðf 3 f l,k3 Þejjl,k3 C k3 C C A dðf 3 f r,k Þejjr,k3

if dðf 3 f s Þejj þ

B B B P @ þ ir,k k3

3

ð17Þ

3

The time domain signals considered are the stator current and its FT which are corrected for the window length to give the frequency domain operation. By using FT values in Amperes (A) in Eq. (17), bi-spectrum values are normalized (divided by the bispectrum maximum value), then the bi-spectra amplitudes (Fig. 2, and Fig. 4) are given without unit and bounded by 1. 3.3. Numerical simulation To evaluate the bi-spectrum performance, a numerical simulation has been performed. This signal is similar to the measured current for three broken bars at rated load. For generating this signal coming from Eq. (14) for k¼1, a sampling frequency of 128 Hz, a data length by segment of 1024 and M¼6 (total length 6144) have been used. In addition, a Hanning window has been applied to the data to reduce spectral leakages due to the selection of the parameters in signal generation and computation. In this way, this simulation will also help to determine the analysis parameters for experimental stator currents: ia ðtÞ ¼ if cosð2pf s tjÞ þ il,1 cosð2pf l,1 tjl,1 Þ þ ir,1 cosð2pf r,1 tjr,1 Þ ð18Þ where if ¼0 dB¼1A, il,1 ¼  80.1 dB¼114.8 mA and ir,1 ¼  78.8 dB¼98.9 mA, fl,1 ¼(1–2s)fs ¼47.8 Hz and fr,1 ¼(1þ2s)fs ¼52.2 Hz, fl,1 þfr,1 ¼2fs, and random phases j, jl,1, jr,1 with a uniform distribution between 0 and 2p. Fig. 1 shows the different simulation results of the time domain signal given by (18), its PS and its bi-spectrum. Hence, the analysis can take into consideration only a signal nonredundant bi-spectral region [1,2].

143

A deep insight in (17) shows the existence in the bi-spectrum of peaks which do not depend on the studied fault. Indeed, it can be revealed by the non-zero products among the three factors of (17). In fact, if the three delta functions (d) of each product have the same support, the result is non-zero and the corresponding peaks appear in the bi-spectrum. From the simulation results shown in Fig. 1, it can be seen the presence of two peaks at (fs, fs) and (fs, 0). Other peak is positioned at the intersection between the lines f1 ¼fs, f2 ¼ fs and f3 ¼f1 þf2 ¼78 Hz (50 Hzþ28 Hz). In order to analyze all these pulses, and for reasons of the bi-spectrum symmetry, the straight lines (vertical bi-spectrum slice) f1 ¼fs and f2 ¼ fx are only considered. In (17) the following expressions appear:  In the first factor Ia(f1 ¼fs): d(0) ¼1 and d(72ksfs) ¼0;  In the second factor Ia(f2 ¼ fx): d(fx  fs) and d(fx  fs 72ksfs);  In the third factor Ina(f1 þ f2 ¼fs þ fx): d(fx) and d(fx 72ksfs). The first factor is the unity and in order to have non-zero results, the other two factors have to contain only pulses with the same support. This is possible if only if 2ks¼1, assuming that the pulse width of Kronecker is equal to zero, the consideration is that this is an approximation and the presence of rounded numerical computation errors makes this formula acceptable at the first approximation. So we can write 2ksE1. This approximation reflects the fact that the position of three peaks remains unchanged for different values of slip s, that is to say that for each value of s it is a new different current harmonic that gives these three impulses. Thus, giving in the second factor the terms d(fx  fs), d(fx) and d(fx  2fs) and in the third factor d(fx), d(fx þ fs) and d(fx  fs). Hence, in the bi-spectrum the peaks d(fx  fs) and d(fx) can appear and they correspond to f1 ¼fs and f2 ¼fs located at (fs, fs) and to f1 ¼fs and f2 ¼0 P P located at (fs, 0) with amplitudes i2f =8 il,k and i2f =8 ir,k , respeck tively. In general il,k 4ir,k, this explains that the peak onk ðf s , f s Þ is the highest. At the sampling frequency of 128 Hz, two symmetrical pulses are detected at (fs, 28 Hz) and (28 Hz, fs), that is at the intersection between the line f3 ¼f1 þf2 ¼fs þ28 (here called decimation line) and the lines f1 ¼ fs and f2 ¼fs. By changing the sampling frequency, the decimation line translates and the peak at (fs, 28 Hz) disappears and can be relocated at others frequencies without disturbing the region of interest (Table 1). It can be concluded that these peaks are only an artifact of the numerical technique. Fig. 1 show only the peaks which do not depend on the studied fault. Nevertheless, other peaks giving information about BRB fault can be observed in the one-dimensional bi-spectrum diagonal slice

Fig. 1. A simulated signal given by (18), and its, power spectrum (a) and bi-spectrum (b).

144

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

a b c

3-phase 50 Hz power source

Variable voltage source ia

Current sensors

ib ic

ia

ia

Analog stator current signal

Selector

Control unit Coupling

Magnetic brake

Induction machine 18.5 kw (Faulty machine) Digital stator current signal

Induction machine 18.5 kw (Healthy machine) Acquisition board 12 bit

adapting and antialiasing filters

Labview in PC Fig. 2. Configuration of the experimental set-up for BRB detection.

Table 1 Effect of decimation on the position of f3 ¼ f1 þ f2.

Table 2 Induction motor characteristics used in the experiment.

Sampling frequency [Hz]

f3 ¼ f1 þf2 [Hz]

Description

Induction motor

128 256 512 1024

78; 206; 462; 973;

Manufacturer Rated power Input voltage Full load current cos j Supply frequency Number of poles Number of rotor bars Number of stator slots Rated slip Rated speed Connection

LEROY-SOMER 18.5 kW 380 V 35.90 A 0.87 50 Hz 4 40 48 0.024 1456 rpm D-connected

(50þ 28) (112 þ94) (250þ 212) (498 þ475)

with f1 ¼ f2 ¼f and given by: Dðf Þ ¼

i3f 8

dðf f s Þejj þ

X i3l,k k

8

dðf f l,k Þejjl,k þ

X i3r,k k

8

dðf f r,k Þejjr,k ð19Þ

3.4. Experimental set-up The tested three-phase squirrel-cage IM (Fig. 2) is used in measuring stator current signals of two three-phase 18.5 kW IM, The characteristics of the two three phase induction motors (healthy and faulty rotors) used in our experiment are listed in Table 2. One IM is undamaged (0BRB) and it is defined as the reference condition whereas the other one is with a synthetic rotor fault with one broken rotor bar (1BRB) or three broken rotor bars (3BRB) at different load levels. The synthetic rotor fault was obtained by drilling a small hole of 3-mm diameter in all the rotor bar depth. The load has been simulated by a magnetic brake which is coupled between the two machines shafts used to create the desired shaft load of operation. For experiments, one current sensor of 20 kHz frequency bandwidth is used. The analog signals are passed through a low-pass anti-aliasing filter with a cut-off frequency of 2 kHz. The current

signals are collected at a sampling frequency of 16,384 Hz for all the experiments by means of a 12-bit A/D converter. The measurements were carried out for different load conditions starting from 20% up to 100% of the rated torque. In order to minimize the FFT leakage effect, the Hanning window has been applied. The further signal processing is performed by using the MATLAB& environment in order to generate power spectra and bi-spectra and the LabView& software for the data acquisition. 3.5. Data analysis The PS and the bi-spectrum of one phase current have been computed by using a 1024-point DFT length, a Hanning smoothing window and no overlap. Moreover, computations have been performed by using the formulas (3) and (8). As a first approach

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

145

0 -50 -100

Amplitude [dB]

-150 0 -50 -100 -150 0 -50 -100 -150 100

200

300

400 500 600 Frequency [Hz]

700

800

900

1000

Fig. 3. Stator current PS of a healthy IM (a), with 1BRB (b) and with 3BRB (c), in the frequency bandwidth [0 Hz, 1000 Hz] at rated load (s¼ 2.4%).

frequency spacing between successive samples of the DFT called the frequency resolution has been Df¼0.125 Hz (Df¼fe/N [Hz]) corresponding with an acquisition time Tacq ¼8 s(Tacq ¼1/Df). All the frequency component magnitudes have been normalized and expressed in dB scale with respect to the fundamental frequency of the power grid set at 0 dB (1 pu). There are some limitations on the amount of information which can be extracted from spectral analysis. A spectral peak at a particular frequency may come from several possible faults. A rotating component may produce a number of spectral peaks at harmonics of the rotational frequency and they can have a constant phase which cannot be detected by the PS. These PS limitations have led to use other diagnostics techniques such as the bi-spectrum to extract the possible non-linear characteristics of the signal. This concept will be discussed in the following section.

4. Experimental results In this section, both PS and BDS analysis will be used to distinguish the fault severity in an IM with BRB at any level of shaft load. In fact, it is very important to detect BRB at low load level since it is well known that the influence of any rotor fault is reduced when the shaft load is low due to the fact that the rotor currents are reduced. Therefore, at low load levels, the influence of rotor currents on the stator side is reduced and the detection becomes more difficult. 4.1. PS analysis

Fig. 4. Stator current bi-spectrum of a healthy IM (a), with 1BRB (b) and with 3BRB (c) in the frequency bandwidth [0 Hz, 60 Hz] at rated load (s¼ 2.4%).

(Fig. 3), the PS of the IM stator current has been represented in the frequency bandwidth [0 Hz, 1000 Hz] for the healthy case, for 1BRB and for 3BRB. As expected many frequencies have been detected because of the large ratio of signal-to-noise (SNR) being around 150 dB. Then, the same cases have been investigated by using the bispectrum in the frequency bandwidths [0 Hz, 60 Hz] (Fig. 4). The total number of samples in each measurement was N¼131,072 samples (N¼Tacq.fe) at a sampling frequency of 16,384 Hz (Dt¼61 ms). The

The data coming from the stator current measurement have been sampled at the frequency 16,384 Hz which leads to a data set with N¼131,072 samples for each variable. The spectra of motor current signals at various loads (0%, 25%, 50%, 75%, and 100% of rated load) and at different numbers of broken bars (0BRB, 1BRB, and 3BRB), are shown in Fig. 5, indicate that the amplitude of the (172s)fs components are noticeable and increase with fault severity. Indeed, in the case of a healthy machine, apart the fundamental frequency of the power grid, it is expected that all the other frequency components will have small magnitudes compared to faulted cases. However, one BRB produces frequency components at (172ks)fs with large magnitudes (Fig. 5). These magnitudes are increasing

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

Amplitude [dB]

Amplitude [dB]

Amplitude [dB]

146

0

48.37 Hz -128 dB

-50 -100

Amplitude [dB]

45

50

55

60

40 0

45

50

55

45

50

55

48.87 Hz -50 -119.3 dB

45

50

55

50

55

60

51.75 Hz -123.6 dB

48.25 Hz -121.6 dB

-100

-50

45

50

47.62 Hz -126 dB

55

45

50

48.13 Hz -117.1 dB

55

60

52 Hz -130.5 dB

52.38 Hz -124.2 dB

40 0 -50

45

50

47.5 Hz -102.8 dB

40

55

60

52.5 Hz -102.5 dB

50

Frequency [Hz]

55

60

50

40

55

60

51.8 Hz -76.16 dB 3BRB 75%

40 0 -50

45

50

55

47.8 Hz -80.1 dB

60

52.2 Hz -78.8 dB 3BRB 100%

-150

-150 45

-50

45

48.2 Hz -78.87 dB

-100 1BRB 100%

0BRB 100% -150

40 0

-150

-100

-100

60

51.13 Hz -79.7 dB

-100 1BRB 75%

60

55

3BRB 50%

-150

40 0

50

-150

-100

0BRB 75%

-150

45

48.87 Hz -50 -81.28 dB -100

1BRB 50%

40 0

60

3BRB 25%

40 0

60

-150 45

55

50.5 Hz -91.61 dB

-100

51.12 Hz -102.6 dB

-100

0BRB 50%

-150

50

-150

51.13 Hz 48.87 Hz -117 dB -50 -104.4 dB

-100

45

49.5 Hz -88.3 dB

-50

1BRB 25%

40 0

60

40 0

60

50.88 Hz -135.7 dB

-150

40 0

3BRB 0%

-150

-100

-150

-50

-100

48.88 Hz -50 -140.7 dB

0BRB 25%

-100

50.6 Hz -86.4 dB

1BRB 0%

50.75 Hz -121.2 dB

49.25 Hz -124.1 dB

-50

49.4 Hz -88 dB

-50

-150

40 0

-50

0

51 Hz -122 dB

-100

-150

0

49 Hz -124 dB

-50

0BRB 0%

40

Amplitude [dB]

0

51.63 Hz -126.3 dB

45

50

55

Frequency f [Hz]

60

40

45

50

55

60

Frequency [Hz]

Fig. 5. Zoomed stator current PS for three modes: healthy, 1BRB and 3 BRB under different shaft load levels (0%, 25%, 50%, 75% and 100% of rated load).

with the fault severity and the higher the load is the larger is the fault visibility. It can be observed that at no load when the slip is too small, the fault-related frequency components have overlaps with the fundamental frequency coming from the grid. Otherwise, as the motor becomes more heavily loaded, the rotational frequency slows and the slip frequency increases. The greater the slip, the greater is the frequency separation observed between (172ks)fs and the fundamental frequency. The lighter the load, the larger the ratio between line frequency amplitude and that of the (172ks)fs sideband; especially, as load moves below 50% of full load. From 50% to 100% load this effect is less significant.

The different magnitudes of frequency components related to BRB have been computed in the three previous cases (healthy, 1BRB, 3BRB) by using the formula (12) for the average value IdB (Fig. 7). It can be seen that even when the machine is operating at no load the healthy rotor can be clearly distinguished from the faulty case (this difference is indicated by dashed circles in Fig. 7). The BDS technique discussed is characterized by a higher sensitivity than the PS, especially when the machine is operating at no-load. In the next section, we present the detection performance evaluation results by comparing the PS-based method and our proposed BDS-based method using ROC curves, which make the results more convincing.

4.2. Bi-spectrum analysis In order to provide a higher resolution in the sampled signal, the data is divided into K segments (K ¼4) according to the step of the bi-spectrum estimation. The overlapping was zero for two consecutive segments with two different fault conditions such as for healthy and for one BRB mode. The three-dimensional graph of the bi-spectrum is difficult to be described and to be analyzed (Fig. 4). However, the BDS has been computed for both healthy and faulty modes (Fig. 6). It has been shown that the BDS method gives similar results compared to PS computed for the same cases at different shaft load levels. However, the detection is even smoother than in the case of PS and it is much more visible. This is due to the fact that the bi-spectrum can effectively filter out the Gaussian noise [9]. Comparing the BDS results plotted in Fig. 6, reveals that there are clear differences in the (172ks)fs sideband component values between the healthy and faulty at different load conditions. Unlike the PS-based method, the proposed BDS-method determines the BRB fault at absolute no-load condition.

4.3. Detection performance evaluation: Need for ROC analysis When comparing two or more diagnostic tests, ROC curves are often the only valid method of comparison [26]. An ROC curves is a detection performance evaluation methodology, and demonstrates how effectively a certain detector can separate two groups in a quantitative manner [26–28]. An ROC curve shows the tradeoff between the probability of detection or true positives rate (tpr), also called sensitivity and recall versus the probability of false alarm or false positives rate (fpr). ROC curves are well described by Fawcett in [26]. The tpr and fpr are mathematically expressed in (20) and (21), respectively. tpr ¼

true positives true positives þ false negatives

ð20Þ

f pr ¼

false positives false positives þ true negatives

ð21Þ

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

|D (f,f)| [dB]

0 -50

49.25 Hz -144 dB

-100

|D (f,f)| [dB]

-50

45

|D (f,f)| [dB]

50

55

60

51.12 Hz -123.8dB

48.88 Hz -105.7 dB

45

50

55

60

51.13 Hz -122.65 dB

45

50

55

48.88 Hz -110.6 dB

60

-50

45

50

48.25 Hz -134.1 dB

55

60

51.75 Hz -138.8 dB

-100

45

50

55

48.625 Hz -128.87dB

60

51.125 Hz -122dB

0BRB 75%

45

50

55

60

52.25 Hz -128dB

47.75 Hz -132 dB

45

50

55

48 Hz -121.6 dB

60

52 Hz -123.5 dB

-100

45

50

55

45

50

55

47.75 Hz -109.20 dB

40

60

45

60

55

60

51.75 Hz -79.86 dB 3BRB 75%

60

52.27 Hz -112.05 dB

40 0 -50

45

50

47.75 Hz -92dB

55

60

52.25 Hz -87.25 dB

-100

1BRB 100%

3BRB 100%

-150 45

50

55

60

40

45

Frequency f [Hz]

Frequency f [Hz]

50

48.25 Hz -82.78 dB

-100

-150

40

55

51 Hz -98.61 dB

-150

-100

0BRB 100%

-150

50

3BRB 50%

40 0 -50

1BRB 75%

40 0 -50

45

49Hz -93.71dB

-100

-150

40 0

60

-150

-100

-150

55

50.63 Hz -94.58 dB 3BRB 25%

40 0

-50

1BRB 50%

40 0 -50

50

-100

-150

40 0

45

49.5 Hz -49.84

-150

-100

0BRB 50%

-150

3BRB 0%

40 0

50.88 Hz -120.1 dB 1BRB 25%

40 0 -50

50.62 Hz -124.33 dB

-100

-150

48.87 Hz -121 dB

49.37 Hz -125.38

-150

40 0

-50

0BRB 25%

-100

-50

-50

1BRB 0%

-100

-150

-50

0

50.87 Hz -128.09 dB

-150

-100

-50

49.12 Hz -139.3

-100

0BRB 0%

40 0

|D (f,f)| [dB]

-50

-150 40 0

|D (f,f)| [dB]

0

50.75 Hz -143.3 dB

147

50

55

60

Frequency f [Hz]

Fig. 6. Zoomed stator current BDS for three modes: healthy, 1BRB and 3 BRB under different shaft load levels (0%, 25%, 50%, 75% and 100% of rated load).

-50

1 0BRB 1BRB 3BRB 0BRB 1BRB 3BRB

Fault index I [dB]

-70 -80

0.8

-90 -100 -110 -120

0.7 0.6 0.5 0.4 0.3

-130

0.2

-140

0.1 0

-150 0

25

Worst case PS BDS

0.9

True positive rate

-60

50 Load level [%]

75

100

Fig. 7. Fault index using the (17 2s)fs components for different shaft load levels for both PS (solid line) and BDS (dashed line).

Additional term associated with ROC curves is, true negatives ¼ 1f pr specificity ¼ false positives þ true negatives

ð22Þ

sensitivity ¼ recall

ð23Þ

For each case (Healthy, 1BRB and 3BRB) and for each load level condition (0%, 25%, 50%, 75% and 100% of rated load), a series of 10 independent Monte-Carlo experiments are conducted. For each experiment, the probability of false alarm and the probability of detection are obtained by counting detection results at each side-

0

0.1

0.2

0.3

0.4 0.5 0.6 0.7 False positive rate

0.8

0.9

1

Fig. 8. ROC curves comparison: The PS-based method and the proposed BDSbased method.

band frequency components (172s)fs amplitude out of 150 independent Monte-Carlo experiments by both the PS-based standard method and our proposed BDS-based method. Each point on the ROC curve corresponds to a specific pair of sensitivity and (1-specificity) and the complete curve gives an overview of the overall performance of a test. When comparing ROC curves of different tests, good curves lie closer to the top left corner and the worst case is a diagonal line (shown as a dashed line in Fig. 8). Fig. 8 shows the ROC curves of the PS-based method and our BDS proposed method. The two curves are obviously not identical; detection algorithm based on BDS-method is better than PS-method, in the

148

L. Saidi et al. / ISA Transactions 52 (2013) 140–148

References

1

Precision

0.95

PS BDS

0.9

0.85

0.8

0.75

0

0.2

0.4

0.6

0.8

1

Recall Fig. 9. Precision-recall graph comparison: The PS-based method and the proposed BDS-based method.

high sensitivity rate. The ROC curves of the PS-based method show degraded performance (lower tpr for the same fpr), on the other hand, the ROC curves of the BDS-based method show slight degradation. Another quantitative measure of the ROC curve performance is the precision-recall (PR) graph [28]. The PR measures the fraction of positive examples that are correctly labeled. In PR space, one plots recall on the x-axis and precision on the y-axis. Recall is the same as tpr, whereas precision measures that fraction of examples classified as positive that are truly positive. Fig. 9 shows the PS curves, which indicate that the BDS detector is a relatively good detector in terms of PR graph, and illustrates how the precision of both methods change as the relative recall (tpr) increases. The precision of the PS-based method drops sharply beyond the tpr¼0.14, but the precision of the BDS-based method is almost not affected by the increasing tpr.

5. Conclusion In this paper, a short overview of the bi-spectral analysis has been presented and a method using the HOS to detect BRB faults has been presented. Data from real tests have been used to express the ability of the bi-spectrum and more exactly the DSB analysis and its associate phase for condition monitoring of threephase IM with rotor faults at no-load. The form of bi-spectral slice is similar to the graph of PS and the main difference is that this slice has inside information about the phase and the non-linear system characteristic. Therefore, it can distinguish in between many operating conditions even with low influence in the PS. The robustness of the proposed method is explored by running a series of independent Monte-Carlo experiments. The evaluation of results using ROC curves makes the results more convincing. By using the bi-spectral analysis for IM condition monitoring, the sensitivity of fault detection can be easily improved without changing the data acquisition. Alternatively, the Wigner bi-spectrum and the wavelet bi-spectrum can be used for condition monitoring in nonstationary cases met during transients and in many real applications.

Acknowledgments The authors would like to thank an anonymous referee for the insightful comments that have significantly improved the article.

[1] Nikias CL, Petropulu A. Higher-order spectra analysis: a nonlinear signal processing framework, Englewood Cliffs, New Jersey: Prentice-Hall, 1993. [2] Mendel JM. Tutorial on higher order statistics (spectra) in signal processing and system theory: theoretical results and some applications, Proceedings of the IEEE 79 (3) (1991) pp. 287–305. [3] Nandi S, Toliyat HA. Condition monitoring and fault diagnosis of electrical machines—a review. IEEE Transactions on Energy Conversion 2005;20(4):719–29. [4] Bellini A, Filippetti F, Tassoni C, Capolino GA. Advances in diagnostic techniques for induction machines. IEEE Transactions on Industrial Electronics 2008;55(12):4109–26. [5] Siddique A, Yadava GS, Singh B. A review of stator fault monitoring techniques of induction motors. IEEE Transactions on Energy Conversion 2005;20(1):106–14. [6] Singh GK, Al Kazzaz SAS. Induction machine drive condition monitoring and diagnostic research-a survey. Electric Power Systems Research 2003;64:145–58. [7] Heng A, Zhang S, Tan ACC, Mathew J. Rotating machinery prognostics: state of the art, challenges and opportunities. Mechanical Systems and Signal Processing 2009;23:724–39. [8] Rehorn AG, Jiang J, Orban PE. State-of-the-art methods and results in tool condition monitoring: a review. International Journal of Advanced Manufacturing Technologies 2005;26:693–710. [9] Bellini A, Yazidi A, Filippetti F, Rossi C, Capolino GA. High-resolution techniques for rotor fault detection of induction machines. IEEE Transactions on Industrial Electronics 2008;55(12):4200–9. [10] Kia SH, Henao H, Capolino G-A. Diagnosis of broken-bar fault in induction machines using discrete wavelet transform without slip estimation. IEEE Transactions on Industry Applications 2009;45(4):1395–404. [11] Kia SH, Henao H, Capolino G-A. A high-resolution frequency estimation method for three-phase induction machine fault detection. IEEE Transactions on Industrial Electronics 2007;54(4):2305–14. [12] Aydin I, Karakose M, Akin E. A new method for early fault detection and diagnosis of broken rotor bars. Energy Conversion and Management 2011;52(4):1790–9. [13] Gritli Y, Stefani A, Rossi C, Filippetti F, Chattia A. Experimental validation of doubly fed induction machine electrical faults diagnosis under time-varying conditions. Electric Power Systems Research 2011;81(3):751–66. [14] Bacha K, Henao H, Gossa M, Capolino G-A. Induction machine fault detection using stray flux EMF measurement and neural network-based decision. Electric Power Systems Research 2007;78(7):1247–55. [15] Puche-Panadero R, Pineda-Sanchez M, Riera-Guasp M, Roger- Folch J, Hurtado-Perez E, Perez-Cruz J. Improved resolution of the MCSA method via Hilbert transform, enabling the diagnosis of rotor asymmetries at very low slip. IEEE Transactions on Energy Conversion 2009;24(1):52–9. ˜ oz AO, Duarte-Mermoud MA. Fault detection in induction [16] Jime´nez GA, Mun motors using Hilbert and Wavelet transforms. Electrical Engineering 2007;89(3): 205–20. [17] Chow TW, Tan HZ. HOS-based nonparametric and parametric methodologies for machine fault detection. IEEE Transactions on Industrial Electronics 2000;47(5):1051–9. [18] Treetrong J, Sinha JK, Gub F, Ball A. Bispectrum of stator phase current for fault detection of induction motor, ISA transactions of the instrumentation. Systems and Automation Society 2009;48(3):378–82. [19] Messina AR, Vittal V. Assessment of nonlinear interaction between nonlinearity coupled modes using higher order spectra. IEEE Transactions on Power Systems 2005;20(1):375–83. [20] Wang WJ, Wu ZT, Chen J. Fault identification in rotating machinery using the correlation dimension and bispectra. Nonlinear Dynamics 2001;25(4): 383–93. [21] Nichols JM, Murphy KD. Modeling and detection of delamination in a composite beam: a polyspectral approach. Mechanical Systems and Signal Processing 2010;24(2):365–78. [22] Yazidi A, Henao H, Capolino G-A, Betin F, Capocchi L. Inter-turn short circuit fault detection of wound rotor induction machines using bispectral analysis, Energy Conversion Congress and Exposition (ECCE) (2010) pp. 1760–5. [23] Zhou Y, Chen J, Dong GM, Xiao WB, Wang ZY. Application of the horizontal slice of cyclic bispectrum in rolling element bearing diagnosis. Mechanical Systems and Signal Processing 2012;26:229–43. [24] Saidi L, Henao H, Fnaiech F, Capolino G-A, Cirrincione G. Application of higher order spectra analysis for rotor broken bar detection in induction machines. IEEE International Symposium on Diagnostics for Electric Machines 2011: 31–8 Power Electronics & Drives (SDEMPED). [25] Zhang GC, Ge M, Tong H, Xu Y, Du R. Bispectral analysis for on-line monitoring of stamping operation. Engineering Applications of Artificial Intelligence 2002;15(1):97–104. [26] Fawcett T. An introduction to ROC analysis. Pattern Recognition Letters 2006;27:861–74. [27] Nichols JM, Trickey ST, Seaver M, Motley SR. Using ROC curves to assess the efficacy of several detectors of damage-induced nonlinearities in a bolted composite structure. Mechanical Systems and Signal Processing 2008;22: 1610–22. [28] Debo´n A, Carlos Garcia-Dı´az J. Fault diagnosis and comparing risk for the steel coil manufacturing process using statistical models for binary data. Reliability Engineering and System Safety 2012;100:102–14.