DZ47LE earth leakage circuit breaker is used for the protection against electrical
leaka ge in t he .... rat ed voltage 220V, used as electron shock protection.
B EARTH LEAKAGE CIRCUIT BREAKER
People Electric Appliance serves for people.
K
ISO9001 ISO14001 OHSAS18001
DZ47LE EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER
APPLICATION DZ47LE earth leakage circuit breaker is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 240V, 3-phase 415V, rated current up to 60A When somebody gets an electirc shock or the residual current of the circuit exceeds the fixe value, the ELCB can cut off the power within the time of 0.1s automatically protecting the personal safety and preventing the equipement from the fault resulted from the residual current. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009 standard. DZ47LE 1P
SPECIFICATIONS Rated Voltage(V)
Pole No
220V
1P
Rated current (A)
Leakage Leakage action dead current(mA) current(mA)
Leakage action time(s)
1~10 30
15
15~32 380V
DZ47LE 2P
2,3,4P
40~60
<0.1 100
50
a.TH35-7.5 rail is used for the product installation. b.Outline and installation dimensions(see the figure and the table) Dimensions Type A
B
C
D
E
DZ47LE-60/1N
46
70
40
45
94
DZ47LE-60/2
64
70
40
45
94
DZ47LE-60/3
91
70
40
45
94
DZ47LE-60/3N
100
70
40
45
94
DZ47LE-60/4
118
70
40
45
94
MAIN TECHNICAL DATA DZ47LE 3P
DZ47LE 4P
A B-01
Single-pole double line
Double-pole double line
Triple-pole triple line
Triple-pole four line
Four-pole four line
DZ47LE C45LE 1/2
DZ47LE C45LE 2/2
DZ47LE C45LE 3/3
DZ47LE C45LE 3/4
DZ47LE C45LE 4/4
RDX65LE EARTH LEAKGE CIRCUIT BREAKER EARTH LEAKGE CIRCUIT BREAKER APPLICATION RDX65LE is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time of 0.1s automatically to protect the personal safety and prevent the equipment from the fault resulted by the residual current. With this funtion, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009.
SPECIFICATIONS RDX65LE 1P
RDX65LE 2P
Number of Poles
1P+N, 2P+N, 3P+N, 4P+N
Rated voltage
240/415V
Rated current
6A 10A 16A 20A 25A 32A 40A 50A 63A
Rated Operating Current(mA)
30mA 100mA 300mA
Rated non-operation (I△n)
≤0.5I△n
Tripping Curve
C,D
RDX2LE-100 EARTH LEAKGE CIRCUIT BREAKER APPLICATION RDX2LE-100 is suitable for the circuit of 50Hz, rated voltage 230/400V, and rated current upto 100A. It has the earth leakage, overload & short circuit protect function. It can also add over voltage protect function. It is mainly used in buiding illumination and electrical distribution system.
SPECIFICATIONS 1P+N,2P+N,3P+N,4P+N
Number of Poles
40,50,63,80,100
Rated Current(A)
30,50,100,200,300
Rated Residual Operating Current(I△n)(mA) RDX2LE-100 2P+N
≤0.5I△n
Rated Residual Non-operation Current(I△no)(mA)
AC 230/400
Rated Voltage(V) Residual Current Off-time
≤0.1S
Short Circuit Capacity(Icu)
3000A
Endurance
≥4000
Tripping Curve
C,D
Portection Degree
IP20
OVERALL AND MOUNTING DIMENSIONS(UNIT:MM) 108 81 54
3P+N 4P 108 3P 81 2P 54
70 44
7.5
16
35 27
27
45
4P 3P 2P 1P
81
RDX2LE-100 3P+N
L
A B-02
DZ47LE EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER APPLICATION This products provide a high level of protection against earth leakage faults by the RCD in addition to the overcurrent and short-circuit protection offered by the MCB. This products are suitable for the protection of circuits with the highest safety requirements (i.e.eletctric apparatus in rooms with high humidity, socket circuits, rooms with bath bubs of shower etc.)
SPECIFICATIONS Rated voltage
230/400V
Rated current
6A 10A 16A 20A 25A 32A 40A 50A 63A
Pole
1P+N 2P 3P 4P
Rated operating current (mA)
30mA 50mA 100mA 300mA
Rated non-operating (I△N)
0.5I△N
Tripping curve
C type D type
Type
Electronic
DZ65LE EARTH LEAKAGE CIRCUIT BREAKER APPLICATION This products provide a high level of protection against earth leakage faults by the RCD in addition to the overcurrent and short-circuit protection offered by the MCB. This products are suitable for the protection of circuits with higher safety requirements (i.e.electric apparatus in rooms with high humidity, socket circuits, rooms with bath bubs or shower etc.)
SPECIFICATIONS
A B-03
Rated voltage
240/415V
Rated current
6A 10A 16A 20A 25A 32A 40A 50A 63A
Pole
1P 2P 3P 4P
Rated operating current (mA)
30mA 50mA 100mA 300mA
Rated non-operating (I△N)
0.5I△n
Tripping curve
C type D type
DXM3L(DZ30L) RESIDUAL CURRENT CIRCUIT BREAKER WITH OVER CURRENT PROTECTION
EARTH LEAKAGE CIRCUIT BREAKER APPLICATIONS DXM3L(DZ30L) leakage protective breaker, DXM3L(DZ30L) (phase wire+neutral wire+leakage +overload voltage) protective breaker is used in the single phase residence circuit of AC.50Hz/60Hz, rated voltage 220V, used as electron shock protection. It can protect civil electron circuit from Test Monthly
overload and short-circuit. This product has advantages of small volume, high breaking capacity zero, and live wires are cutted off at the same time, also protecting person from electric shock when the livewire connected opposite. This product conforms to IEC61009, Gb6829, GB/16917 .
DXM3L(DZ30L)
PC60NL EARTH LEAKAGE CIRCUIT BREAKER APPLICATION The PC60NL RCCB incorporates a residual current operated electromagnetic release which operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage fault between phase and earth greater than or equal to I△n. The PC60NL combined with MCB & RCCB Provides: 1. protection against indirect contact 2. complementary protection against direct contact 3. protection for the installation against insulation faults
PC60NL
PS250LE RESIDUAL CURRENT CIRCUIT BREAKER APPLICATION PS250LE RCBO is suitable for the circuit of 50/60Hz, rated voltage 230/400V,and rated current up to 100A. It has the earth leakage, overload, short circuit protect function. It can also add over voltage protect function. It is mainly used in building illumination and electrical distribution system.
SPECIFICATIONS PS250LE 2P
Number of Pole Rated Current(A) Rated Residual Operating Current(I△n)(mA) Rated Residual Non-operation Current(I△n)(mA) Rated Voltage(V)
PS250LE 4P
A B-04
1P+N,2P,3P+N,4P 40,50,63,80,100 30,50,100,200,300 ≤0.5I△n AC 230/400
Residual Current Off-time
≤0.1S
Short Circuit Capacity(Icu)
3000A
Endurance
≥4000
Tripping Type
C,D
Protection Degree
IP20
RDX6LE-63 EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER ADVANTAGE ● Earth leakage Circuit Breaker With Overcurrent Protection ●Electronic type ●Compact structure, small volume, (two modules in width) ●With short circuit, overload and residual current protection RDX6LE-63
●Action function has nothing to do with main circuit voltage ●With midline cut-off functions, it is safer and more reliable. ●With double functional connection terminals, it has strong connection ability. ●With contact state indicator, it is easy to recognize the contact situation. ●Different handle colors are used to indicate different rated current. ●High breaking capacity:10KA ●With wide range of rated current, it can be used as family main switch ●United accessories series
RDX6LE-63
●Type can provent the error tripping caused by electric equipment
SPECIFICATIONS Pole No.
2 P
Standards
IEC61009(EN61009)GB16917.1
Rated Current
Type C 6,10,13,16,20,25,32,40A Type D 6,10,13,16,20A
Rated eakage Current I△n
30,100mA
Rated Voltage(Ue)
230V;50Hz
Tripping Time
G Minimum 10ms for prolonging AC type
Sensitivity
RDX6LE-63
Type
3
Breaking Capacity Icn
10KA
Tripping Characteristic
C,D
Grade of Protection
IP40
Service Life
Electric:no less than 4000 times Machanic:no less than 20000 times
Terminal Connection
Wire 1-25 square micron Bus-bar row thickness 0.8-2mm
Shell width
Din Rail 35mm(Two modulus in width)
MOUNTING DIMENSION 5.5
30.5
4.5
1P+N
N
2
N
45
80
1
9.5
35
A B-05
44 60
PID RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER
APPLICATION PID RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk ine. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings, constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use in DC pulse system.
SPECIFICATIONS 1P+N,3P+N
Number of Pole
16,20,25,40,50,63
Rated Current(A) Rated Residual Operating Current(I△n)(mA)
30,100,300,500 AC 230/240
Rated Voltage(V)
AC400/415
PID 2P
0.5I△n~1I△n
Residual Operating Current Scope
≤0.3S
Residual Current Off-time Short Circuit Capacity(Icu)
6000A
Endurance
4000
Protection Degree
IP20
NORMAL OPERATION AND MOUNTING REQUIREMENT ● Circumstance temperature-5℃~+40℃,average temperature not exceeding 35℃. ● Altitude above sea level less than 2000m. ● Humidity not exceeding 50% at 40℃and not exceeding 90% at 25℃. ● Installation class Ⅱ or Ⅲ. ● Pollution class Ⅱ. ● Installation method DIN Rail mounting type. ● The external magnetism shall not be more than 5 times of terrestrial one. PID 4P
● Product shall be installed vertically at the place where there shall be no severe impact or vibration. The product is switched on when the handle is at upper position.
OVERALL AND MOUNTING DIMENSIONS(Unit:mm)
72
36 N
65
35.5
O.OFF
N
A B-06
85
N
O.OFF
65 85
74.5
PID-N RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER
CONSTRUCTION AND FEATURE ● Applicable to terminal and pin/fork type busbar connection ● Contact position indication ● High short-circuit current withstand capacity ● Provides protection against earth fault/leakage current and function of isolation ● Fire resistant plastic parts endures abnormal heating and strong impact PID-N 2P 25A~30mA 400V~
● Equipped with finger protected connection terminals ● Automatically disconnect the circuit when earth fault/ leakage current occurs and exceeds the rated sensitivity. ● Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
PID-N 2P
PID-N 4P 25A~30mA 400V~
TECHNICAL DATA ● Pole No.: 2, 4 ● Connection terminal: ● Rated current(A): 25, 40, 63 ○ Screw terminal ● Rated voltage: 230/400V AC ○ Pillar terminal with clamp ● Rated frequency: 50/60Hz ● Fastening torque: 2.0Nm ● Mode: electro-magnetic type, electronic type ● Installation: ○ On symmetrical DIN rail 35mm ● Residual current characteristics: A, AC ○ Panel mounting ● Rated making and breaking capacity: 630A ● Rated residual operating current I△n(mA): 10, 30, 100, 300, 500 ● Rated residual non-operating current I△no: 0.5I△n ● Rated conditional short-circuit current Inc: 6000A ● Rated conditional residual short-circuit Current I△c: 6000A ● Tripping duration: instantaneous tripping≤0.1s ● Residual tripping current range: 0.5I△n~1I△n ● Electro-mechanical endurance: 4000 cycles ● Connection capacity: Rigid conductor 25mm2
PID-N 4P
WIRING DIAGRAM
A B-07
PF7 RESIDUAL CURRENT DEVICE RESIDUAL CURRENT DEVICE APPLICATION The RCD is in conformity with the standard of IEC61008, GB16916 and BS EN61008. The RCD can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line, thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCD is mainly suitable for using in variety of plants and enterprises, buildings constructions, commerces, guesthouses and families. It can be used in circuits up to single phase 230V, three phases 400V 50 to 60Hz. The RCD is not suitable for using on DC pulse system.
ELECTRICAL PF7 2P
Design according to Tripping time
Rated voltage Rated tripping current Sensitivity Rated short Circuit strength
PF7 4P
Maximum back-up fuse for Short circuit protection Maximum back-up fuse for Oveload protection Resistance to climatic conditions Degree of protection Endurance electrical comp. mech comp.
ICE61008 (EN 61008) undelayed min.10 ms delay min.40 ms delay with selective disconnecting function 230/400V; 50Hz 10,30,100,300,500mA AC and pulsating DC 10KA with 63A gL back-up fuse 10KA with 80A gL(F7-80 and-863) 6KA(rated current 63A) with 63A gL 63A gL 80A gL (F7-80 and-863) 45A gL(F7-25 and-40A) 40A gL(F7-80 A) according to IEC 61008 built-in switch IP 40 ≤4.000 operating cycles ≥20.000 operating cycles
MECHANICAL
PF7-N 2P
Frame size Socket size Device width Mounting Upper and lower terminals Terminal protection
PF7-N 2P
Terminal capacity Busbar thickness
DIMENSION (Units: mm)
PF7-N 4P
PF7-N 4P
A B-08
45mm 80mm 35mm (2mod.), 70mm (4mod.) quick fastening with 2 lock-in Positions on DIN rail En50022 open mouthed/lift terminals finger and hand touch safe, VBG 5, OVE-EN 6 1 --- 25mm2 0.8 - 2mm
PNFIN RESIDUAL CURRENT DEVICE RESIDUAL CURRENT DEVICE APPLICATION PNFIN Residual Current Device(RCD) is in conformity with the standard of IEC61008, VDE 0664, CEE27 and BS4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. PNFIN RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerces, guesthouses and families. It can be used in circuits up to single phase 240V, three phases 415V, 50 or 60Hz.
SPECIFICATIONS
PNFIN 2P
Type Rated current In (A) Rated operating current for earth leakage I△n(A) Rated non-operating current for earth leakage I△n(A) Voltage Un(V) Pole
PNFIN25 PNFIN40 PNFIN63 PNFIN100 25 40 63 100 0.03,0.1,0.3,0.5 0.1,0.3,0.5 0.5I△n 415(380)V 240(220)V 2,4
MAIN TECHNICAL DATA I△n 0.2
Operating time(second)
PNFIN 4P
Limited value of non-operating current for balance load or unbalance load In minimum value of rated making and breaking capacity Rated conditional short circuit current Inc(A) Endurance(times)
2I△n 0.1
0.25A(or5I△n) 0.04 2In
In=25 200 1500
In=40 300 2000
In=63 400 3000 4000
PFIN RESIDUAL CURRENT DEVICE APPLICATION PFIN Residual Current Device(RCD) is in conformity with the standard of VDE 0664, CEE27 and BS4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. PFIN ELCB is mainly suitable for varieties of plants and enterprises, buildings, constructions, commerces, hotels and families. It can be used in circuits up to single phase 240V, three phases 415V, 50 or 60Hz. PFIN 2P
MAIN TECHNICAL DATA I△n 0.2
Operating time(second) Limited value of non-operating current for balance load or unbalance load In minimum value of rated making and breaking capacity Rated conditional short circuit current Inc(A) Endurance(times)
2I△n 0.1
0.25A(or5I△n) 0.04 2In
In=25 200 1500
In=40 300 2000
In=63 400 3000 4000
SPECIFICATION
PF1-4P
A B-09
Type Rated current In (A) Rated operating current for earth leakage I△n(A) Rated non-operating current for earth leakage I△n(A) Voltage Un(V) Pole
PFIN25 PFIN40 PFIN63 PFIN100 25 40 63 100 0.03,0.1,0.3,0.5 0.1,0.3,0.5 0.5I△n 415(380)V 240(220)V 2,4
PF360 RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER APPLICATION The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for useing in varieties of plants and enterprises, buildings constructions. It can be used in circuits up to 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system.
SPECIFICATION Number of Pole
2P,4P
Rated Current (A)
16,20,25,32,40,50,63,80,100
Rated Residual Operating Current (I△n)(mA)
10,30,100,300,500 ≤0.5 I△n
Rated Residual Non-operation Current (I△no)(mA) PF362 2P
AC 230/240
Rated Voltage (V)
AC 400/415 Residual Operating Current Scope
0.5I△n~1I△n
Residual Current Off-time
≤0.3S
Short Circuit Capacity (Icu)
3000A
Endurance
4000
Protection Degree
Ip20
OPERATION PRINCIPLE
1
3
1
3
5
7 N
I> 2
PF364 4P
I>
4
2
4
8 N
6
OVERALL AND MOUNTING DIMENSIONS (UNIT: MM) 69 35 17.5 17.5 2
90.4 71 46
17.5 2
7.5
A B-10
70 17.5 17.5 17.5
17.5 2
46
17.5 2
6.3
90.4
44
90.4 71
68
7.5
PR RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER DESCRIPTION To open a circuit automatically in case of an earth leakage fault between phase and earth and / or neutral greater or equal to 10mA, 30mA, 100mA, 300mA or 500mA. It is used in domestic, commercial and industrial installations.
EARTH FAULT INDICATOR Mechanical indicator appearing on the front face of the RCCB is to be differed between tripping and off position yellow-tripped.
NUISANCE TRIPPING PRC 2P
All the RCCBs are protected against transient voltages (lightening, line disturbances)and transient currents (from high capacitive circuits) DC sensitive RCCBs or time delay devices are available, please consult us you also have the possibiliy to install the following accessories: electrical cover kit, locking kit. Sensitivity High sensitiviy:10mA
30mA
PRC 4P
Medium sensitivity:100mA
Low sensitivity:300mA
PRCC 2P
Low sensitivity:500mA
PRCC 4P
A B-11
Terminal cover kit: (1 se = 2 covers)
For RCCBs2 For RCCBs4 For RCCBs2 For RCCBs4
Pole 2 2 2 2 2 2 2 2 4 4 4 4 2 2 2 2 2 4 4 4 4 4 2 2 2 2 2 4 4 4 2 2 2 2 2 2 2 4 4 4 4 4 16 to 63A 16 to 63A 80 to 100A 80 to 100A
Current rating 16A 25A 16A 25A 40A 63A 80A 100A 25A 40A 63A 80A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 10 sets 10 sets 10 sets 10 sets
cat.ref. PRC216B PRC225B PRCD216B PRCD225B PRCD240B PRCD263B PRCD280B PRCD284B PRCD425B PRCD440B PRCC463B PRCD480B PRCE225B PRCE240B PRCE263B PRCE280B PRCE284B PRCE425B PRCE440B PRCE463B PRCE480B PRCE484B PRCF225B PRCF240B PRCF263B PRCF280B PRCF284B PRCF425B PRCF440B PRCF463B PRCF480B PRCF484B PRCG225B PRCG240B PRCG263B PRCG280B PRCG284B PRCG425B PRCG440B PRCG463B PRCG480B PRCG484B PRCZ005 PRCZ006 PRCZ007 PRCZ008
PR101 RESIDUAL CURRENT CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER
APPLICATION PR101 Series Earth Leakage Circuit Breakers apply to in AC circuit of frequency of 50 Hz, rated voltage up to 415V, rated current up to 80A. It is mainly used as an indirect contact protection fot human. It also can be used to prevent against the fire danger caused by earth falt current owing to equipment insulation damage. When the protective measures of the electric shock are out of work, the RCCB whose rated residual operating current less than 30mA can serve as the supplementary protection for in direct contact, but it can’t be used as the sole direct contact protection.
PRODUCT FEATURES
PR101 2P
1. PR101 Series Leakage Circuit Breakers are the protector for pure electromagnetic residual current operation. 2. The operation function is unrelated to circuit voltage, but operation is reliable. 3. It can be reliably operated on the loss of phase or neutral. 4. The capacity of resisting electromagnetic interference is strong.
MAIN TECHNICAL DATA Type
Un (V)
Im I△m
Hz
Inc I△m
In A
I△no The maximum of break-time(s) mA I△N 2I△N 5I△N 0.25A 500A
I△n mA 30
500A (In≥ 50A 10In) 6000A (In> 50A)
PR101 240 2P
6,10, 16,25, 32,40, 50,63 80
50, 60
PR101 4P
500A 6,10, (In≥ 16,25, 50A 6000A 32,40, 10In) 50,63 (In> 80 50A)
PR101 415 4P
15
0.2
0.1
-
0.04
0.04
50
25
75
40
0.2
0.1
-
0.04
0.04
0.2
0.1
-
0.04
0.04
100
50
0.2
0.1
0.04
-
0.04
300
150
0.2
0.1
0.04
0.04
0.04
500
250
0.2
0.1
0.04
0.04
0.04
30
15
0.2
0.1
-
0.04
0.04
50
25
0.2
0.1
-
0.04
0.04
75
40
0.2
0.1
-
0.04
0.04
100
50
0.2
0.1
0.04
-
0.04
300
150
0.2
0.1
0.04
0.04
0.04
500
250
0.2
0.1
0.04
0.04
0.04
DIMENSIONS 45 91
72
T
36
T
54 43.7 6.5
TH35
90 L1 L2 L3 N PE
Y1Y2
A B-12
M A
W1
B
180
44 64
12-6672
90 45
13 5 N
I 2/1 4/3 6/5 N/N
24 6 N
T
PBV-D RESIDUAL CURRENT CIRCUIT BERAKER RESIDUAL CURRENT CIRCUIT BREAKER ELECTRICAL DATA Design according to Tripping time
Rated voltage Rated tripping current Sensitivity Rated short Circuit strength
PBV-D 2P
Maximum back-up fuse for Short circuit protection Maximum back-up fuse for Overload protectiton Resistance to climatic conditions Degree of protection Endurance electrical comp. mech comp
IEC 61008 (EN 61008) undelayed min.10 ms delay min.40 ms delay with selective disconnecting function 230/400V; 50Hz 10,30,100,300,500mA AC and pulsating DC 10KA with 63A gL back-up fuse 10KA with 80A gL (F7-80 and -863) 6KA(rated current 63A)with 63A gL 63A gL 80A gL(F7-80 and 863) 45A gL(F7-25 and -40A) 40A gL(F7-80 A) according to IEC 1008 built-in switch IP 40 ≤4.000 operating cycles ≥20.000 operating cycles
MECHANICAL DATA
PBV-D 4P
Frame size Socket size Device width Mounting Upper and lower terminals Terminal protection Terminal capacity Busbar thickness
A B-13
45mm 80mm 35mm (2mod.), 70mm (4mod.) quick fastening with 2 lock-in Positions on DIN rail En50022 open mouthed/lift terminals finger and hand touch safe, VBG 5, OVE-EN 6 1 --- 25mm2 0.8 - 2mm
PG RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER APPLICATION PG RCCB, rated current is adjustable from 10A up to 60A. User can select suitable current for better protection against overload and short-circuit. The products comply with IEC61008.
SPECIFICATIONS 2
Number of Pole Rated Voltage(V) PG230
4
250/440 10,15,20,30,45,50,60A Adjustable
Rated Current(A) Leakage Motion Current(mA)
300,500
300,500
Leakage Dead Current(mA)
150,250
150,250
DIMENSION (Units: mm) 1
PG430
210
N 3 2 1
210
N
53
53 70
115
70
70
TG RESIDUAL CURRENT CIRCUIT BREAKER
TG230
APPLICATION TG RCCB, rated current is adjustable from 10A up to 60A. User can select suitable current for better protection against overload and short circuit.The products comply with IEC61008.
SPECIFICATIONS Number of Pole Rated Voltage(V) Rated Current(A) TG430
A B-14
2
4
250/440 10,15,20,30,45,50,60A Adjustable
Leakage Motion Current(mA)
300,500
300,500
Leakage Dead Current(mA)
150,250
150,250
PL9 RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER
APPLICATION PL9 Residual Current Device is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. PL9 RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerces, guesthouses and families. It can be used in circuits up to 1phase 230V and 3 phases 400V 50/60Hz.
PL9 2P
SPECIFICATIONS 2P,4P
Number of Pole
40,50,60
Rated Current(A)
30,100,300
Rated Residual Operating Current(I△n)(mA)
≤0.5I△n
Rated Residual Non-operation Current(I△n)(mA)
AC 230/400
Rated Voltage(V)
≤0.1S
Residual Current Off-time Short Circuit Capacity(Icu)
3000A
Endurance
≥4000 IP20
Protection Degree PL9 4P
SPECIFICATIONS
Type
PDBR230
PDBR430
Poles
2P
4P
Rated voltage(V)
250V/440V
Rated current(A)
5A-15A,10-30A,30-60A Adjustable
PDBR230 2P
Leakage motion current(mA)
300mA
500mA
1000mA
Leakage dead current(mA)
150mA
250mA
500mA
Accord with standand PDBR430 4P
A B-15
NFC61450
CBT EARTH LEAKAGE CIRCUIT BREAKER EARTH LEAKAGE CIRCUIT BREAKER USAGE CBT Residual Current Circuit Breaker without over current protection conforms to the standard of GB16916.1, IEC61008, BS4293 etc. It is used in the circuits of AC50~60Hz, single phase 230V(220V), three phases 400V(380V) in industrial & mining enterprises, commercial buildings and housing for protection of personal electric shock hazard and electric equipment and for unfrequent switchover of circuits under normal conditions.
INSTRUCTIONS This RCCB is intended for installation within an enclosure in an ambient temperature between -5℃ and 40℃ with an average value not exceeding 35℃ over a 24 hours period. It should not be CBT 2P
installed at an altitude greater than 2000m above sea level, nor in an atmosphere subject to excessive pollution by smoke, dust, chemical fumes, salt laden spray, prolonged periods of high humidity or other abnormal conditions. See current product catalogues for a wide range of suitable enclosure.
PL13 EARTH LEAKAGE PROTECTING DEVICE
SPECIFICATION PL13-01
● Conforms with UL standard 943 CLASS A(GFCI and 498 receptacle). ● Protects against ground fault shock hazard from frayed wiring, damaged appliances, wherever electrical contact might provide a path to ground through human body. ● Can be wired to provide 20 amp GFCI feed-through protection to other outlets on outlets on the same circuit. ● Overload and neutral line error grounding protection. ● Trip thresholds of 4~6 milliamps. Unit trips within 0.025 seconds of fault detection. ● Operate within -35℃~66℃ environmental temperature. ● Protect against 10~450MHz voice interference.
PL13-02
● Made of high impact termoplastic to resist damage from impact and frequent use. And with unbreakable nylon wall plate. ● Back and side wiring terminals permit fast installation. Clearly marked line and load terminals. ● Incorporate dual bolt terminal and installation screws which accept standard screw driver blades. ● The voltage and frequency of the product can be designed as per customers different repuirements.
PL13-03
A B-16
GFCI RECEPTACLE RECEPTACLE
ART.NO.
DESCRIPTION
BODY COLOR
BUTTON COLOR
GFCI, Duplex
PTG15-L-2AL
ALMOND
RED RESET/ BUTTON TEST
Receptacle With red
PTG15-L-2DE
DEEP-ALMOND
Reset Button and blue
PTG15-L-2BL
BLACK
Test button 20A, 125V
PTG15-L-2GR
GRAY
AC, 60Hz,
PTG15-L-2IV
IVORY
With LED light
PTG15-L-2WH
WHITE
Indicator
PTG15-L
ART.NO.
DESCRIPTION
BODY COLOR
BUTTON COLOR
GFCI, Duplex
PTG20-L-1AL
ALMOND
ALMOND
Receptacle Buttons
PTG20-L-1DE
DEEP-ALMOND
DEEP-ALMOND
Match body face color
PTG20-L-1BL
BLACK
BLACK
20A, 125V AC, 60Hz,
PTG20-L-1GR
GRAY
GRAY
With LED light
PTG20-L-1IV
IVORY
IVORY
Indicator
PTG20-L-1WH
WHITE
WHITE
PTG20-L
ART.NO.
DESCRIPTION GFCI, Duplex Receptacle With red Reset Button and blue Test button 20A, 125V AC, 60Hz, With LED light Indicator
BODY COLOR
BUTTON COLOR
PTG20-L-2AL
ALMOND
RED RESET/
PTG20-L-2DE
DEEP-ALMOND
BUTTON TEST
PTG20-L-2BL
BLACK
PTG20-L-2GR
GRAY
PTG20-L-2IV
IVORY
PTG20-L-2WH
WHITE
PTG20-L 3 Grace Switch can control resistance and inductance load which meets residential use and commercial use for its reliability and unique performance. Switch Characteristics ● Large head double-drive combination screws for quick wiring ● Back and side wire connection are easy to be installed ● Green grounding screw ● Choice of different color
A B-17
GFCI RECEPTACLE RECEPTACLE
DESCRIPTION
ART.NO.
BODY COLOR
GFCI, Duplex
PTG15-2AL
ALMOND
Receptacle With red
PTG15-2DE
DEEP-ALMOND
Reset Button and blue
PTG15-2BL
BLACK
Test button 20A, 125V
PTG15-2GR
GRAY
AC, 60Hz,
PTG15-2IV
IVORY
PTG15-2WH
WHITE
ART.NO.
BODY COLOR
BUTTON COLOR RED RESET/BUTTON TEST
PTG15
DESCRIPTION
BUTTON COLOR
GFCI, Duplex
PTG20-1AL
ALMOND
ALMOND
Receptacle Buttons
PTG20-1DE
DEEP-ALMOND
DEEP-ALMOND
Match body face color
PTG20-1BL
BLACK
BLACK
20A, 125V AC, 60Hz.
PTG20-1GR
GRAY
GRAY
PTG20-1IV
IVORY
IVORY
PTG20-1WH
WHITE
WHITE
PTG20
DESCRIPTION
BUTTON COLOR
PTG20-2AL
ALMOND
RED RESET/
Receptacle With red
PTG20-2DE
DEEP-ALMOND
BUTTON TEST
Reset Button and blue
PTG20-2BL
BLACK
Test button 20A, 125V
PTG20-2GR
GRAY
AC, 60Hz,
PTG20-2IV
IVORY
PTG20-2WH
WHITE
DESCRIPTION
A B-18
BODY COLOR
GFCI, Duplex
PTG20
PTG15-L
ART.NO.
ART.NO.
BODY COLOR
BUTTON COLOR
GFCI, Duplex
PTG15-L-1AL
ALMOND
ALMOND
Receptacle Buttons
PTG15-L-1DE
DEEP-ALMOND
DEEP-ALMOND
Match body face color
PTG15-L-1BL
BLACK
BLACK
15A, 125V AC, 60Hz.
PTG15-L-1GR
GRAY
GRAY
With LED light
PTG15-L-1IV
IVORY
IVORY
indicator
PTG15-L-1WH
WHITE
WHITE
GFCI RECEPTACLE RECEPTACLE PTM-1 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES DESCRIPTION
ART. N0.
Single-pole Toggle
PTM-1AL
ALMOND
Switch With
PTM-1DE
DEEP-ALMOND
Grounding Screw
PTM-1BL
BLACK
Quick Wiring and
PTM-1GR
GRAY
Side Wiring
PTM-1IV
IVORV
PTM-1WH
WHITE
COLOR
PTM-2 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES DESCRIPTION
ART. N0.
COLOR
3-Way Toggle
PTM-2AL
ALMOND
Switch With
PTM-2DE
DEEP-ALMOND
Grounding Screw
PTM-2BL
BLACK
Quick Wiring and
PTM-2GR
GRAY
Side Wiring
PTM-2IV
IVORV
PTM-2WH
WHITE
PTM-3 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES DESCRIPTION
ART. N0.
Single-pole
PTM-3AL
ALMOND
Decorative Switch
PTM-3DE
DEEP-ALMOND
Screw Quick
PTM-3BL
BLACK
Wiring and Side
PTM-3GR
GRAY
Wiring
PTM-3IV
IVORV
PTM-3WH
WHITE
COLOR
PTM-4 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES
A B-19
DESCRIPTION
ART. N0.
3-WayDecorative
PTM-4AL
ALMOND
COLOR
Switch With
PTM-4DE
DEEP-ALMOND
Grounding Screw
PTM-4BL
BLACK
Quick Wiring and
PTM-4GR
GRAY
Side Wiring
PTM-4IV
IVORV
PTM-4WH
WHITE
GFCI RECEPTACLE RECEPTACLE RECEPTACLE CHARACTERISTICS ● Additional assembly screw ● Side wire connection and 8 holes back quick wire connection ● Choice of different color ● Green grounding screw ● Large head double-drive combination screws for quick wiring
DESCRIPTION
ART. N0.
COLOR
PTMSR-15/1J-AL PTMSR-15/1-AL Standard Duplex Receptacle 15A, 125V AC With“1J”, for PTMSR-15/1J
Self-grounding Clip “1”for Standard wire
PTMSR-15/1JED PTMSR-15/1ED
ALMOND
PTMSR-15/1JBL
DEEP-ALMOND
PTMSR-15/1BL
BLACK
PTMSR-15/1JGR
GRAY
PTMSR-15/1GR
IVORV
PTMSR-15/1JIV
WHITE
PTMSR-15/1IV PTMSR-15/1JWH PTMSR-15/1WH
DESCRIPTION
ART. N0.
COLOR
PTMSR-15/2J-AL PTMSR-15/2-AL Standard Duplex Receptacle 15A, 125V AC With“2J”, for Self-grounding PTMSR-15/2J
Clip “2”for Standard wire
PTMSR-15/2JED PTMSR-15/2ED
ALMOND
PTMSR-15/2JBL
DEEP-ALMOND
PTMSR-15/2BL
BLACK
PTMSR-15/2JGR
GRAY
PTMSR-15/2GR
IVORV
PTMSR-15/2JIV
WHITE
PTMSR-15/2IV PTMSR-15/2JWH PTMSR-15/2WH
A B-20