IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 24, NO. 9, SEPTEMBER 2009

2193

Fixed-Frequency Boundary Control of Buck Converter With Second-Order Switching Surface Wai-To Yan, Member, IEEE, Carl Ngai-Man Ho, Member, IEEE, Henry Shu-Hung Chung, Senior Member, IEEE, and Keith T. K. Au

Abstract—This paper presents a fixed-frequency boundary control of buck converters. The method is based on integrating the concept of variable hysteresis into the boundary control technique with second-order switching surface. The switching frequency is maintained constant over a wide range of supply voltages and output loads. The method is based on using a frequency-to-voltage converter and comparing its output voltage with a reference voltage to control the width of the hysteresis in the boundary controller. It also combines the advantages of the boundary control that the converter can reach the steady state in two switching actions after large-signal disturbances. The basic operating principles, stability analysis, and design procedures will be given. The proposed control method has been successfully applied to control a 140 W, 24 V/12 V buck converter. The steady-state characteristics, including the switching frequency and output voltage ripple, at different input voltages and output loads with and without the proposed control method have been compared. The system responses under largesignal supply voltage and load disturbances will be discussed. Index Terms—Boundary control, constant switching frequency, geometric control method, second-order switching surface, state trajectory control.

I. INTRODUCTION OUNDARY control techniques with linear switching surfaces, such as hysteresis control and sliding-mode control [1]–[10], or nonlinear switching surfaces [11]–[14] have been proposed to be alternatives to pulsewidth-modulated control strategies in dc/dc switching regulators. It addresses the complete operation of a converter and does not differentiate startup, transient, and steady-state periods [1], [2]. Based on studying the trajectory families on the state plane, a switching surface is defined to determine the states of the switches. An ideal switching surface can achieve global stability, good large-signal operation, and fast dynamics. The methods with linear switching surface are based on guiding the trajectory from any initial state on the state plane to the target operating point while the one with nonlinear/curved switching surface can

B

Manuscript received December 7, 2008; revised March 13, 2009. Current version published August 28, 2009. This work was supported by the Research Grants Council of the Hong Kong Special Administrative Region, China, under Grant CityU 112407. This paper was presented in part at the IEEE Power Electronics Specialists Conference 2008. Recommended for publication by Associate Editor M. Vitelli. W.-T. Yan, H. S.-H. Chung, and K. T. K. Au are with the Centre for Power Electronics, City University of Hong Kong, Kowloon Tong, Kowloon, Hong Kong(e-mail: [email protected]; [email protected]; [email protected]). C. N.-M. Ho is with ABB Switzerland Ltd., Corporate Research, BadenDaettwil 5405, Switzerland (e-mail: [email protected]). Color versions of one or more of the figures in this paper are available online at http://ieeexplore.ieee.org. Digital Object Identifier 10.1109/TPEL.2009.2022165

be made close to the ideal switching surface. Instead of guiding the trajectory, the switching surface is derived by estimating the trajectory movement after a switching action. This results in a high state trajectory velocity along the switching surface and can accelerate the trajectory moving toward the target operating point within two switching actions after input and output disturbances. A comparative study of the boundary controls using first- and second-order switching surfaces has been discussed in [12], [13]. However, due to the dependence of the output voltage ripple on the relative magnitudes of the input and output voltages, and load power, the boundary control is largely operated at a variable switching frequency. This will make the design of the filter components difficult in some applications. Recently some digital techniques have extended the concept of [11]–[13] for digital control, such as the time-optimal control in [17], [18] and the capacitor charge balance technique in [19]. For reducing the structure complexity, an attempt of an analog-based fixed-frequency boundary control having the same fast response characteristics in [11]–[13] is proposed in this paper. In keeping the operating frequency constant in the boundary control, there are many techniques in the literature. They can be categorized into the hysteresis comparator methods [20], variable width hysteresis comparator methods [21]–[25], and injection of a fixed-frequency external signal methods [26]–[28]. Among them, the variable width hysteresis comparator method has been proved to be robust and reliable [23]. This paper presents a control method that integrates the concept of the variable width hysteresis in boundary control with secondorder switching surface. Instead of using the phase-locked loop (PLL) in [23], the proposed method is based on a frequencyto-voltage conversion to deal with the limited lock-in range in PLL [24], [25]. It does not require external frequency generator, but a reference dc voltage for controlling the switching frequency. It extends the advantages of the boundary control with the second-order switching surface that the converter can reach the steady state in two switching actions after large-signal input or output disturbances. Thus, it combines the advantages of operating at a fixed switching frequency in the steady state and having fast response in the transient period. The basic operating principles, system stability analysis, and design procedures will be given. The method has been successfully applied to a buck converter. The steady-state behaviors, including the switching frequency and output voltage ripples, and large-signal dynamics under input and output disturbances have been studied. Theoretical predictions are verified with experimental results of a 140 W, 24 V/12 V prototype.

0885-8993/$26.00 © 2009 IEEE Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

2194

Fig. 1.

Fig. 2.

IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 24, NO. 9, SEPTEMBER 2009

Fig. 3.

Small-signal block diagram of the control loop.

Fig. 4.

Key time-domain waveforms of the converter.

System block diagram.

System implementation.

II. OPERATING PRINCIPLES Fig. 1 shows the system block diagram. It consists of four major parts, including the main power conversion stage (PCS), the second-order boundary controller (SBC) [11]–[13], the frequency-to-voltage converter (FVC), and the error amplifier (EA). Fig. 2 shows the implementation of the whole system. FVC firstly converts the gate signal vg for PCS into a dc voltage vFVC , which will then be compared with a reference voltage Vf ,ref by EA. The output of EA, ∆, is used to control the hysteresis band. SBC inside will generate upper and lower bands together with ∆ to determine the switching times of the main switch S in PCS. Thus, the function of SBC is used to regulate the output voltage and the earlier mentioned four parts form a feedback loop for regulating the switching frequency. Fig. 3 shows the block diagram of the small-signal frequency control loop. Any variation in the switching frequency δfs will give rise a voltage variation in δvf by the FVC. Then, as the variation of the reference frequency (and hence vf ,ref ) is zero, the error signal δε to the EA is the same as δvf . δε will be amplified by EA to give a signal variation in the hysteresis band of δ∆

to the PCS and SBC, so that the switching frequency variation is corrected. This completes the small-signal control loop for regulating the switching frequency. In the following discussions, the operations of the SBC will be given and the switching frequency will be derived. The smallsignal models of the four parts and thus the overall control loop in Fig. 3 will then be formulated. A. Operation of SBC The PCS has two operating modes, namely Mode 1 and Mode 2, in one switching cycle. The key time-domain waveforms are shown in Fig. 4. Assume that the components are ideal in the following derivations. The following state-space equations can be derived for each mode. In Mode 1 (t1 ≤ t < t3 ), S is ON and D is OFF. diL 1 = [vi (t) − vC (t)] dt L   1 dvC vC (t) = iL (t) − dt C R

(1) (2)

where L and C are the output filter inductor and capacitor, respectively, vC and iL are the capacitor voltage (output voltage) and inductor current, respectively, vi is the input voltage, and R is the load resistance. Thus, the inductor current increases linearly in this mode.

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

YAN et al.: FIXED-FREQUENCY BOUNDARY CONTROL OF BUCK CONVERTER WITH SECOND-ORDER SWITCHING SURFACE

2195

Assume that iC varies linearly in Mode 1. Thus, by substituting (5) into (1) dt =

L diC . vi (t) − vC (t)

(6)

Then, by substituting (6) into (2), the Mode-1 state trajectory can be shown to be  t 1 iC (t) dt vC (t) = vC (t1 ) + C t1 ∼ = vC (t1 ) + K1 (t1 )[i2C (t) − i2C (t1 )]

(7)

where K1 (t1 ) = 2C [v i (t 1 L)−v C (t 1 )] . Similarly, assume that iC varies linearly in Mode 2. By substituting (5) into (3) dt = − Fig. 5. State-plane trajectories (solid lines: Mode-1 trajectories, dotted lines: Mode-2 trajectories). TABLE I COMPONENT VALUES OF THE PROTOTYPE

L diC . vC (t)

(8)

Thus, by substituting (8) into (4), the Mode-2 state trajectory can be shown to be  t 1 vC (t) = vC (t3 ) + iC (t)dt C t3 ∼ = vC (t3 ) − K2 (t3 )[i2C (t) − i2C (t3 )]

(9)

where K2 (t3 ) = 2C vLC (t 3 ) . The criteria for switching S ON is based on considering that iC (t2 ) = 0

(10)

vC (t2 ) = vo,m in (t) = vref (t) − ∆

(11)

and In Mode 2 (t3 ≤ t < t5 ), S is OFF and D is ON. 1 diL = − vC (t) dt L   1 dvC vC (t) = iL (t) − . dt C R

(3) (4)

Thus, the inductor current decreases linearly in this mode. Two sets of state trajectories, namely Mode-1 and Mode-2 trajectories shown in Fig. 5, corresponding to each mode can be derived as follows. The values of L and C given in Table I are used to derive Fig. 5. The Mode-1 trajectories are drawn with solid lines while the Mode-2 trajectories are drawn with dotted lines. As the load variation is small, vC is relatively constant over a switching cycle. Thus

diL ∼ diC = dt dt

vC (t) ≤ vo,m in + K1 (t)i2C (t)

(5)

Hence, the capacitor current ripple is the same as the inductor current ripple. Equation (5) is commonly used to derive the input-to-output conversion characteristics. Such assumption is valid because the variation in the capacitor voltage is much smaller than the average capacitor voltage. Thus, the variation in the load current (io ) is very small.

and

iC (t) < 0. (12)

The criteria for switching S OFF is based on considering that iC (t4 ) = 0

(13)

vC (t4 ) = vo,m ax (t) = vref (t) + ∆

(14)

and

where vo,m ax is the maximum value of vo . Thus, by substituting (13) and (14) into (9), S will be switched OFF when vC (t) ≥ vo,m ax − K2 (t) i2C (t)

iL = iC + io ⇒

where vo,m in is the minimum value of vo , vref is the output voltage reference and ∆ is the hysteresis band. Thus, by substituting (10) and (11) into (7), S will be switched ON when

and

iC (t) > 0. (15)

The controller continuously senses the output voltage and capacitor current. When the criteria given in (12) or (15) is satisfied, the controller will give the necessary command to the power stage. They are valid for both static and transient operations and form the second-order switching surface σ 2 in Fig. 5 for a given vref on the state plane. The first-order switching surface σ 1 is also shown in Fig. 5 for comparison. The main difference between σ 1 and σ 2 is that the former switching surface directs the trajectories to the operating point through switching actions,

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

2196

IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 24, NO. 9, SEPTEMBER 2009

while the latter one is derived by using the natural response of the converter. For the sake of simplicity in the practical implementation, the values of K1 and K2 are constant and are defined at the nominal values of vi and vo . References [12] and [13] have done a comprehensive analysis on studying the effects of the converter behaviors with nonoptimal values of K1 and K2 . The results show that the system dynamics will only take more than two switching actions before reaching the steady state. B. Switching Frequency and Output Voltage Ripple By substituting (5) into (1) and (3), it can be shown that   iC (t3 ) − iC (t1 ) (16) t3 − t 1 = L vi − vref and



 iC (t5 ) − iC (t3 ) . t5 − t3 = −L vref

Equations (12) and (15) will then give  iC (t5 ) = iC (t1 ) = − and

 iC (t3 ) =

(17)

2(1 − k)∆ K2

(19)

(20)



and K =



K √1 K 2 2k K 2 + 2(1−k )K 1

.

As illustrated in Fig. 4, the output voltage ripple equals 2∆. C. Small-Signal Modeling A small-signal stability analysis is used to study and design the feedback loop of the frequency control loop, because its feedback mechanism is considered as a simple linear control system. Based on (20), the small-signal frequency-to-ripple transfer function GSBC of SBC is GSBC (s) =

ωLP δvf (s) = δvFVC (s) s + ωLP

(22)

where ωLP = R L P1C L P is the cutoff frequency of the low-pass filter. A noninverting EA shown in Fig. 2 is used. Its transfer function Gc is Gc (s) =

s + ωC δ ∆(s) =− δ ε(s) s

(23)

where ωC = R C 1C C is the cutoff frequency of the EA. Thus, as shown in Fig. 3, the loop gain TOL of the frequency control loop is

(18)

fS = TS−1 = (t5 − t1 )−1 = HK∆−0.5 1 v r e f (v i −v r e f ) L vi

GLP (s) =

TOL (s) = GSBC (s) GFVC (s) GLP (s) Gc (s) 2k∆ K1

where k = vvr ei f . Detailed proofs of (18) and (19) are given in the appendix. Thus, by substituting (18) and (19) into (16) and (17), the switching frequency fS is equal to

where H =

The transfer function GFVC of the FVC can be considered as a constant KFVC because the bandwidth is wide as compared with the switching frequency of the converter. The transfer function GLP (s) of the low-pass filter at the output of FVC is

δ fS (s) 1 ¯ −1.5 = KSBC = − KT HK ∆ δ ∆(s) 2

(21)

¯ is the steady-state value of the hysteresis band at the where ∆ considered operating point. KT is the total gain including the gain of the transducers. The transfer function of SBC is assumed to be constant because the crossover frequency of the feedback control loop shown in Fig. 3 is much lower than the switching frequency. For the prototype that will be discussed in Section IV, the crossover frequency of the feedback control loop is chosen to be 17 Hz and the switching frequency is 25 kHz. Moreover, the dynamic response of SBC is very fast. The validity of the assumption has been confirmed by the experimental measurements and theoretical predictions in Section IV.

= KSBC KFVC

ωLP (s + ωC ) s (s + ωLP )

(24)

The stability can be ensured if |TOL (jωc )| 1− (25) ∆IL fS Vin,m ax and C>

∆IL . 8fS ∆Vo

(26)

Detailed derivations of (25) and (26) can be found in [29]. 2) Based on (7) and (9), the values of K1 and K2 are chosen to be L  K1 = (27) 2C V¯in − vref K2 =

L 2Cvref

(28)

where V¯in = 12 (Vin,m in + Vin,m ax ). 3) The values of H and K can be obtained readily from (20).

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

YAN et al.: FIXED-FREQUENCY BOUNDARY CONTROL OF BUCK CONVERTER WITH SECOND-ORDER SWITCHING SURFACE

Fig. 6.

2197

Circuit implementation of the system shown in Fig. 2.

4) The values of RLP , CLP , RC , and CC are chosen so that ωLP = 2 ωC = α(2πfS ), where α  1. Thus, by using (22) and (23) 1 = 2 απfS RLP CLP

(29)

1 = απfS . RC CC

(30)

and

IV. EXPERIMENTAL VERIFICATIONS A 140 W buck converter has been designed and tested and the specifications are given as follows: a) input voltage,vi : 20–30 V; b) output voltage,vo : 12 V;

c) maximum output voltage ripple, 2∆: 160 mV; d) maximum inductor current ripple: 7 A; e) switching frequency: 25 kHz; Based on the design procedures given in Section III, the values of the components used in the prototype are given in Table I. The output load is a resistor bank. The FVC used is TC9400 with the bandwidth up to 100 kHz. The circuit implementation of the system is shown in Fig. 6. Figs. 7 and 8 show the waveforms of the output voltage and the gate signal when the load resistance is changed from 1.1 Ω (11 A, 132 W) to 4.8 Ω (2.5 A, 30 W), and vice versa, respectively. The transient periods last about 42 µs and 84 µs, respectively, and the converter settles in two switching actions. The steadystate switching period is kept at about 40 µs before and after the two load disturbances. Fig. 9(a) and (b) show the dynamic behaviors of the output vf in Fig. 2 and the hysteresis band ∆ during the two load disturbances given in Figs. 7 and 8. The settling times in both cases are approximately equal to 1.95 ms.

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

2198

IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 24, NO. 9, SEPTEMBER 2009

Fig. 7. Sudden change of the output current io from 11 A (132 W) to 2.5 A (30 W). (v o : 1 V/div, io : 5 A/div, v g : 2 V/div) (Timebase: 100 µs/div).

Fig. 8. Sudden change of the output current io from 2.5 A (30 W) to 11 A (132 W). (v o : 1 V/div, io : 5 A/div, v g : 2 V/div) (Timebase: 100 µs/div).

Figs. 10 and 11 show the waveforms when the input voltage is suddenly changed from 20 V to 30 V, and vice versa, respectively. The transient periods last about 40 µs and 50 µs, respectively. Again, the converter settles in two switching actions and the steady-state switching period is also kept at about 40 µs before and after the two input disturbances. The input voltage is introduced with a high percentage of ripples. Apart from studying the dynamic response, it can be observed that the output voltage can be regulated tightly at the steady state without being affected by the input voltage ripple. The steady-state characteristics of the converter with and without proposed control method have been studied. Without the proposed control method, Fig. 12(a) shows the experimental results of the switching frequency and output voltage ripple when the input voltage is 24 V. The output power is varied from 15 W to 140 W. The switching frequency has a percentage variation of 57%, varying between 14.5 kHz and 22.8 kHz. Moreover, when the output power ranges between 15 W and 40 W, the converter is operated in discontinuous conduction mode. The converter is then in continuous conduction mode (CCM) when the output power is above 40 W. With the proposed control method, Fig. 13(a) shows the experimental results of the switching frequency and output voltage ripple when the input voltage is 24 V. With the same output load range, the switching frequency has a percentage change of about

Fig. 9. Transient response of v f and ∆ in Fig. 1 (v f : 1 V/div, ∆: 1 V/div) (Timebase: 1 ms/div). (a) The output current is changed from 11 A (132 W) to 2.5 A (30 W). (b) The output current is changed from 2.5 A (30 W) to 11 A (132 W).

Fig. 10. Sudden change of the input voltage v i from 20 V to 30 V. (v o : 2 V/div, v i : 10 V/div, v g : 2 V/div) (Timebase: 100 µs/div).

3%, varying between 24.5 kHz and 25.3 kHz. The converter is operated in CCM over the operating range. With or without the proposed control method, when the output power increases, the output voltage ripple decreases because the duty cycle of the main switch is increased. Without the proposed control method, Fig. 12(b) shows the experimental results of the switching frequency and output voltage ripple without the proposed control method when the output power is 70 W. When the input voltage varies between 20 V and

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

YAN et al.: FIXED-FREQUENCY BOUNDARY CONTROL OF BUCK CONVERTER WITH SECOND-ORDER SWITCHING SURFACE

2199

Fig. 11. Sudden change of the input voltage v i from 30 V to 20 V. (v o : 2 V/div, v i : 10 V/div, v g : 2 V/div) (Timebase: 100 µs/div).

Fig. 13. Switching frequency and output voltage ripples with the proposed control method. (a) At different output powers. (b) At different input voltages.

Fig. 12. Switching frequency and output voltage ripples without the proposed control method. (a) At different output powers. (b) At different input voltages.

30 V, the switching frequency has a percentage change of about 20%, varying between 20.8 kHz and 24.9 kHz. Fig. 13(b) shows the corresponding experimental results with the proposed control method. When the input voltage varies between 20 V and 30 V, the switching frequency has a percentage change of about 2.4%, varying between 24.6 kHz and 25.2 kHz. With or without the proposed control method, when the input voltage increases, the output voltage ripple increases because the duty cycle of the main switch is decreased. In the earlier mentioned measurements, although the switching frequency has slight deviations from the reference frequency of 25 kHz, there is no frequency jittering throughout the operations. Fig. 14(a) and (b) show the theoretical and experimental gain and phase curves of the control loop shown in Fig. 3,

Fig. 14. Characteristics of the control loop shown in Fig. 3. (a) Gain curve. (b) Phase curse.

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

2200

IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 24, NO. 9, SEPTEMBER 2009

respectively. The experimental results are in close agreement with the theoretical results, which are obtained by using the values shown in Table I. The crossover frequency is at about 17 Hz and the phase margin is more than 30◦ . The loop gain characteristics show that the controller is in stable operation. In this prototype, a low crossover frequency is chosen to eliminate fast variation of the switching frequency if the supply or load disturbances are pulsating and repetitive. Experimental results show that such low crossover frequency does not affect the fast dynamic response of the SBC. Nevertheless, the bandwidth of the control loop can be increased by changing the time constant of the EA shown in Fig. 2. For the sake of simplicity in the earlier analysis, the equivalent series resistance (ESR) of the output capacitor is neglected. As studied theoretically and experimentally in [12] and [13], the effects of the ESR do not affect the converter’s performance significantly with the boundary control using second-order switching surface. In the experimental prototype, two different sensors, including sensing resistor and Hall-effect current sensor, have been used to sense the capacitor current. Both sensing methods do not cause adverse effect on the converter’s performance.

V. CONCLUSION An improved boundary control technique with second-order switching surface for buck converters has been presented. It exhibits two key features. First, the technique combines the advantage of SBC that the converter can reach the steady state in two switching actions after large-signal disturbances. Second, the switching frequency can be kept at a relatively constant value and the implementation of the frequency control loop only requires simple circuitry. A 140 W prototype has been tested. Overall there is good agreement between the theoretical predictions and experimental measurement results. As the proposed control is a combination of the hysteresis band regulation and nonlinear switching surface, it can be extended to other switching surfaces such as the switching surfaces proposed in [14] and [15]. Further work will be dedicated to study the converter operating in DCM.

APPENDIX A. Proofs of (18) and (19) As shown in [29] ∆=

vref (1 − k) . 16 LC fS2

(A.1)

Based on (1) and (5), for t1 ≤ t < t3 vC (t) = vref − ∆ +

vi (1 − k) (t − t2 )2 . 2LC

(A.2)

Thus t1 − t 2 = t2 − t 3 = −

k . 2fS

(A.3)

By substituting (A.3) into (A.2) vref (1 − k) vC (t1 ) = vC (t3 ) = vref + 8LC fS2   1 = vref + 2 k − ∆. 2



1 k− 2



(A.4)

Equations (18) and (19) can be obtained by putting (A.4) into (12) and (15), respectively. REFERENCES [1] P. T. Krein, Nonlinear Phenomena in Power Electronics: Attractors, Bifurcation, Chaos, and Nonlinear Control. New York: IEEE Press, 2001, ch. 8. [2] R. Munzert and P. T. Krein, “Issues in boundary control,” in Proc. IEEE Power Electron. Spec. Conf. Rec., 1996, pp. 810–816. [3] M. Greuel, R. Muyshondt, and P. T. Krein, “Design approaches to boundary controllers,” in Proc. IEEE Power Electron. Spec. Conf. Rec., 1997, pp. 672–678. [4] M. Carpita and M. Marchesoni, “Experimental study of a power conditioning system using sliding mode control,” IEEE Trans. Power Electron., vol. 11, no. 5, pp. 731–742, Sep. 1996. [5] B. J. Cardoso, A. F. Moreira, B. R. Menezes, and P. C. Cortizo, “Analysis of switching frequency reduction methods applied to sliding-mode controlled DC-DC converters,” in Proc. IEEE Appl. Power Electron. Conf. Expo. Rec., 1992, pp. 403–410. [6] S. C. Tan, Y. M. Lai, and C. K. Tse, “A unified approach to the design of PWM-based sliding-mode voltage controllers for basic DC-DC converters in continuous conduction mode,” IEEE Trans. Circuits Syst. – I, vol. 53, no. 8, pp. 1816–1827, Aug. 2006. [7] C. H. Tso and J. C. Wu, “A ripple control buck regulator with fixed output frequency,” IEEE Power Electron. Lett., vol. 1, no. 3, pp. 61–63, Sep. 2003. [8] W. Yan, J. Hu, V. Utkin, and L. Xu, “Sliding mode pulsewidth modulation,” IEEE Trans. Power Electron., vol. 23, no. 2, pp. 619–626, Mar. 2008. [9] S. C. Tan, Y. M. Lai, and C. K. Tse, “Indirect sliding mode control of power converters via double integral sliding surface,” IEEE Trans. Power Electron., vol. 23, no. 2, pp. 600–611, Mar. 2008. [10] J. Matas, L. G. de Vicuna, J. Miret, J. M. Guerrero, and M. Castilla, “Feedback linearization of a single-phase active power filter via sliding mode control,” IEEE Trans. Power Electron., vol. 23, no. 23, pp. 116–125, Jan. 2008. [11] K. S. Leung and H. Chung, “Derivation of a second-order switching surface in the boundary control of buck converters,” IEEE Power Electron. Lett., vol. 2, no. 2, pp. 63–67, Jun. 2004. [12] K. S. Leung and H. Chung, “A comparative study of the boundary control of buck converters using first- and second-order switching surfaces-part I: Continuous conduction mode,” in Proc. 36th IEEE Power Electron. Spec. Conf., Recife, Brazil, 2005, pp. 2133–2139. [13] K. Leung and H. Chung, “A comparative study of the boundary control of buck converters using first- and second-order switching surfaces,” IEEE Trans. Power Electron., vol. 22, no. 4, pp. 1196–1209, Jul. 2007. [14] M. Ordonez, M. T. Iqbal, and J. E. Quaicoe, “Selection of a curved switching surface for buck converters,” IEEE Trans. Power Electron., vol. 21, no. 4, pp. 1148–1153, Jul. 2006. [15] J. Chiu, K. Leung, and H. Chung, “High-order switching surface in boundary control of inverters,” IEEE Trans. Power Electron., vol. 22, no. 5, pp. 1753–1765, Sep. 2007. [16] M. Ordonez, J. E. Quaicoe, and M. T. Iqbal, “Advanced boundary control of inverters using the natural switching surface: Normalized geometrical derivation,” IEEE Trans. Power Electron., vol. 23, no. 6, pp. 2915–2930, Nov. 2008. [17] Z. Zhao and A. Prodic, “Continuous-time digital controller for highfrequency DC–DC converters,” IEEE Trans. Power Electron., vol. 23, no. 2, pp. 564–573, Mar. 2008. [18] V. Yousefzadeh, A. Babazadeh, B. Ramachandran, E. Alarc´on, L. Pao, and D. Maksimovic, “Proximate time-optimal digital control for synchronous buck DC–DC converters,” IEEE Trans. Power Electron., vol. 23, no. 4, pp. 2018–2026, Jul. 2008. [19] E. Meyer, Z. Zhang, and Y. F. Liu, “An optimal control method for buck converters using a practical capacitor charge balance technique,” IEEE Trans. Power Electron., vol. 23, no. 4, pp. 1802–1812, Jul. 2008.

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.

YAN et al.: FIXED-FREQUENCY BOUNDARY CONTROL OF BUCK CONVERTER WITH SECOND-ORDER SWITCHING SURFACE

[20] B. Nicholas, M. Fadel, and Y. Ch´eron, “Sliding mod control of DC-to-DC converters with input filter based on the Lyapunov-function approach,” in Proc. Eur. Power Electron. Conf. (EPE), 1995, pp. 1338–1343. [21] J. M. Ruiz, S. Lorenzo, I. Lobo, and J. Amigo, “Minimal UPS structure with sliding mode control and adaptive hysteresis band,” in Proc. Int. Conf. Ind. Electron. Contr. Instrum. (IECON), 1990, vol. 2, pp. 1063–1067. [22] L. Malesani and P. Tenti, “A novel hysteresis control method for current controlled VSI PWM inverters with constant modulation frequency,” IEEE Trans. Ind. Appl., vol. 26, no. 1, pp. 88–92, Jan./Feb. 1990. [23] L. Malesani, P. Mattavelli, and P. Tomasin, “Improved constant-frequency hysteresis current control of VSI inverters with simple feedforward bandwidth prediction,” IEEE Trans. Ind. Appl., vol. 33, no. 5, pp. 1194–1202, Sep./Oct. 1997. [24] D. Grant, “Frequency control of hysteretic power converter by adjusting hysteresis levels,” U.S. Patent 6 348 780, Feb. 2002. [25] A. Mihalka, “Fixed frequency hysteretic regulator,” U.S. Patent 6 885 175, Apr. 2005. [26] J. Silva and S. Paulo, “Fixed frequency sliding modulator for current mode PWM inverters,” in Proc. Power Electron. Spec. Conf., 1993, pp. 623–629. [27] B. Nicholas, M. Fadel, and Y. Ch´eron, “Fixed-frequency sliding mode control of a single-phase voltage source with input filter,” in Proc. IEEE Int. Symp. Ind. Electron. (ISIE), 1996, pp. 470–475. [28] S. C. Tan, Y. M. Lai, C. K. Tse, and M. K. H. Cheung, “A fixed-frequency pulsewidth modulation-based quasi-sliding-mode controller for buck converters,” IEEE Trans. Power Electron., vol. 20, no. 6, pp. 1372–1392, Nov. 2005. [29] N. Mohan, T. Undeland, and W. Robbins, Power Electronics, Converters, Applications, and Design. New York: Wiley, 2003.

Wai-To Yan (M’08) received the B.Eng. degree (with honors) in electronic engineering from the City University of Hong Kong, Kowloon, Hong Kong, in 2007. Currently, he is a Research Assistant at the Centre for Power Electronics, City University of Hong Kong. His recent research interests include control of switching converters and parasitic cancellation techniques.

2201

Henry Shu-Hung Chung (S’92–M’95–SM’03) received the B.Eng. degree in electrical engineering in 1991, and the Ph.D. degree in 1994, both from The Hong Kong Polytechnic University, Kowloon, Hong Kong. Since 1995, he has been with the City University of Hong Kong (CityU), Kowloon, Hong Kong. Currently, he is a Professor in the Department of Electronic Engineering and Chief Technical Officer of e.Energy Technology Limited—an associated company of CityU. His research interests include time- and frequency-domain analysis of power electronic circuits, switched-capacitor-based converters, random-switching techniques, control methods, digital audio amplifiers, soft-switching converters, and electronic ballast design. He has authored six research book chapters, more than 250 technical papers including 110 refereed journal papers in his research areas, and holds ten patents. Dr. Chung was IEEE student branch counselor and was track chair of the technical committee on power electronics circuits and power systems of IEEE Circuits and Systems Society in 1997–1998. He was Associate Editor and Guest Editor of the IEEE Transactions on Circuits and Systems-–Part I: Fundamental Theory and Applications in 1999–2003. He is currently an Associate Editor of the IEEE Transactions on Power Electronics. He was awarded the Grand Applied Research Excellence Award in 2001 from the City University of Hong Kong.

Keith T. K. Au was born in Hong Kong, in 1983. He received the B.Eng. degree in electronic and communication engineering from the City University of Hong Kong, Kowloon, Hong Kong, in 2006. During 2006–2007, he worked as a Research Assistant in the City University of Hong Kong. His research interests include digital controlled power electronic applications and active power filters.

Carl Ngai-Man Ho (M’07) received the B.Eng. and M.Eng. degrees and the Ph.D. degree in electronic engineering from the City University of Hong Kong, Kowloon, Hong Kong, in 2002 and 2007, respectively. His Ph.D. work focused on the development of dynamic voltage regulation and restoration technology. From 2002 to 2003, he worked as a Research Assistant at the City University of Hong Kong. In May 2007, he joined ABB Corporate Research, Ltd., Baden-D¨attwil, Switzerland, as a Scientist, where he is currently involved in development of power electronics systems based on novel power semiconductor devices for LV applications. He owns two U.K. patents in the area of lighting application. His recent research interests include lighting applications, power quality, modeling and control of power converters, and power semiconductor devices applications. Dr. Ho has served as a Reviewer for the IEEE TRANSACTIONS ON POWER ELECTRONICS, IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS and several conferences.

Authorized licensed use limited to: ABB SWITZERLAND LTD (JLT). Downloaded on September 10, 2009 at 12:44 from IEEE Xplore. Restrictions apply.