Fuse Holders

10 downloads 9282 Views 994KB Size Report
L awson Fuses offer an exte n s i ve range of fuse-holder and fuse-link ... wide variety of panel mounted applications. The range ... Comparison Charts. 13.
LAWSON FUSES L awson Fuses offer an exte n s i ve range of fuse-holder and fuse-link designs. L awson fuse-holders and fuse-banks are approved to major standards and designed to meet a wide range of applications: power distribution, motor protection, electronic, railway, shipping and street lighting. Two distinct designs of British Standard fuse-holders are available. The BOLTIN range accommodates bolted tag fuse-links to BS 88: Pa rt 2, in ratings of 20, 32, 63, 100, and 200 Am p s. The CLIPFIT range acco m m od ates co m p a ct dimensioned fuse-links to BS88: Part 6 and is available in ratings of 20, 32, and 63 Amps. Both ranges are available in a variety of colours and terminal configurations.

Both the BOLTIN and CLIPFIT fuse-holders are also available as f a ctory built fuse-bank assemblies. The fuse-banks co m p ri s e single-phase assemblies of busbar co n n e cted fuse-holders mounted on a back rail, for incorporation in distribution fuse panels. Lawson fuse-holders also include the well established ranges of PULLCAP and SLYDLOK products. The PULLCAP 240/415V a.c. modular fuse-holders incorporate Types MD and L cylindrical fuse-links to BS88: Part 1 and BS1361. The SLYDLOK range offers a wide variety of panel mounted applications. The range includes miniature fuse-holders for 5 x 20mm and 6.3 x 32mm fuse-links, compact fuse-holders rated up to 60 Amps at 240V a.c., and the W/X fuse-holder series, which accommodates either fuse-links or fuse-wire. Cylindrical fuse-holders are a ve r s atile option, o f fe ring fuse protection in four popular sizes up to a maximum fuse-link rating of 125 Amps. These fuse-holders accept cylindrical fuse-links to IEC60269 with principal dimensions of 8 x 31mm, 10 x 38mm, 14 x 51mm and 22 x 58mm.

2

Index

LAWSON FUSE-HOLDERS

Page Introduction

3

Boltin

4

Clipfit

5

Fuse-Banks

6-7

Pullcap

8

Slydlok Products

9-10

Modular Fuse-Holders

11

Double pole Cut-Out

12

Comparison Charts

13

Quality Lawson Fuses ope rates a Qu a l i ty Ma n a g e m e nt Sys tem which has been indepe n d e ntly assessed and approved by ASTA Ce rt i f i cation Se rv i ces as complying with ISO 9001 and is suppo rted by the issue of Ce rt i f i cate No. 11050. Lawson manufactured fuse-links have been independently certified by ASTA and where appropriate comply with the the rules of the latest ASTA 20 Scheme, which authorises Lawson Fuses to endorse those products “ASTA 20 CERT”

For details of products other than Fuse-Holders, please ask for other publications. 3

BOLTIN 660/690V a.c. Fuse-Holders for Fuse-Links to BS88: Part 2 & IEC 60269-2

TYPE LBI

The BOLTIN fuse-holders are available in three versions, front connected, back connected, and front/back connected, in ratings of 20, 32, 63, 100, and 200 Amps. The range fully complies with BS88: Part 2 and is ASTA Certified to a test duty of 80kA at 660V and complies with the current edition of the IEE Wiring Regulations.

List Reference

For white fuse-holders substitute WH for BK in list references. Green fuse-holders are available, details on request.

4

Current Rating (A)

Colour

Lawson Fuse-Link 415V 660V

Solid Link

LBI 20 FC/FC BK LBI 20 FC/BC BK 20 NIT SSA1 SLA1 20 LBI 20 BC/BC BK LBI 32 FC/FC BK LBI 32 FC/BC BK 32 GTIA/TIA SSA2 SLA2 32 LBI 32 BC/BC BK LBI 63 FC/FC BK LBI 63 FC/BC BK 63 Black TIS SSA3 SLA3 63 LBI 63 BC/BC BK LBI 100 FC/FC BK LBI 100 FC/BC BK 100 TCP SSA4 SLA4 100 LBI 100 BC/BC BK LBI 200 FC/FC BK LBI 200 FC/BC BK 200 CTF/TF SSB2 SLB2 200 LBI 200 BC/BC BK Spare Carriers Spare Cable Shrouds (Grey) DIN-Rail Adaptor LBI 20 CA BK LBI 20 SH LBI 20 DA LBI 32 CA BK LBI 32 SH Busbar Stud Connector LBI 63 CA BK LBI 63 SH LBI 100 CA BK LBI 100 SH LBI 32 LBI 200 CA BK LBI 200 SH LBI 63

CLIPFIT 240/415V a.c. Fuse-Holders for Fuse-Links to BS88: Part 6 & IEC 60269-2

TYPE LCF

CLIPFIT fuse-holders provide a simple safe range designed to a c co m m od ate the co m p a ct dimension fuse-links to BS88: Part 6 and are ASTA ce rtified to the re q u i red test duty. Breaking capacities are 50kA at 240V a.c. and 80kA at 415V a.c. CLIPFIT is available in 20, 32, and 63 Amp rat i n g s, and inco rpo rates an integral DIN rail mounting facility as well as single screw fixing. Fro nt co n n e cte d, back co n n e cte d, f ro nt/busbar

co n n e cted

and

fro nt/back

co n n e cte d

co n f i g u rations are available in black or white as standard co l o u r s. List Reference

For white fuse-holders substitute WH for BK in list references.

LCF 20 FC/FC BK LCF 20 FC/BBC BK LCF 20 FC/BC BK LCF 20 BC/BC BK LCF 32 FC/FC BK LCF 32 FC/BBC BK LCF 32 FC/BC BK LCF 32 BC/BC BK LCF 63 FC/FC BK LCF 63 FC/BBC BK LCF 63 FC/BC BK LCF 63 BC/BC BK

Voltage Rating (V)

Current Rating (A)

240

20

415

32

415

63

Colour

Black

Lawson Fuse-Link (BS Ref )

Solid Link

SS (E1)

SLE1 20

NS (F1)

SLF1 32

MES (F2)

SLF2 63

Spare Carriers

Busbar Stud Connector

LCF 20 CA BK LCF 32 CA Bk LCF 63 CA BK

LBC 20 LBC 32 LBC 63

5

FUSE-BANKS

TYPE FB/FZ

Both the BOLTIN and CLIPFIT fuse-holders can be supplied as pre-assembled fuse-banks. The fuse-banks consist of single phase assemblies of shrouded busbar co n n e cted fuse-holders mounted on a back rail for inco rpo ration into s t a n d a rd and heavy duty distribution fusebo a rds to f a c i l i t ate compliance with BS 5486: Part 1, EN60439 - 1 and BS 5486: Part 11. The fuse-banks may be mounted either h o ri zo ntally or ve rt i ca l l y.

A fully insulated inco m i n g

te rminal shroud can be positioned to accept cable ent ry f rom va rying dire ct i o n s.

BOLTIN Dimensional Drawings

6

FUSE-BANKS

Diversity Factor

4 Way 6 Way 8 Way 12 Way

BOLTIN

CLIPFIT

20A, 32A, 63A, 100A

20A, 32A, 63A

0.9 0.8 0.8 0.66

0.9 0.9 0.8 0.8 0.8 0.8 0.66 0.66

0.9 0.8 0.8 0.66

0.9 0.8 0.8 0.66

0.9 0.8 0.66 -

0.9 0.8 0.8 0.66

BOLTIN and CLIPFIT Terminal Bolt Size - Incoming Circuit 20/32 Amp 63 Amp 100 Amp -

4 / 6 / 8 / 12 Ways 4 / 6 / 8 / 12 Ways 4 / 6 / 8 Ways

10.5mm 12.5mm 12.5mm

Maximum Cable Sizes - Outgoing Circuits BOLTIN

CLIPFIT 2

20 Amp - 10mm 32 Amp - 16mm 2 63 Amp - 25mm 2 100 Amp - 70mm2

20 Amp - 16mm 2 32 Amp - 16mm 2 63 Amp - 25mm2

CLIPFIT Dimensional Drawings

7

PULLCAP MODULAR FUSE-HOLDERS

TYPE LPC

Component

Carrier

Cover Plate

Current Rating (A) 5 5 20 20 32 32 63 5 5 20 20 32 32 blank 63

Colour White Black Blue Green Red Black Black White Black Blue Green Red Black Black Black

32

Black

63

Black

Base

The PULLCAP 240/415 V a.c. modular fuse-holders incorporate fuse-links to BS88: Part 1 and BS1361.

List Reference LPC 5 CA WH LPC 5 CA BK LPC 20 CA BL LPC 20 CA GN LPC 32 CA RD LPC 32 CA BK LPC 63 CA BK LPC 5 CP WH LPC 5 CP BK LPC 20 CP BL LPC 20 CP GN LPC 32 CP RD LPC 32 CP BK LPC 00 CP BK LPC 63 CP BK LPC 32 FC/FC LPC 32 FC/BBC LPC 32 FC/BC LPC 32 BC/BC LPC 32 FC/FCL LPC 32 FCL/FCL LPC 63 FC/FC LPC 63 FC/BBC LPC 63 FC/BC LPC 63 BC/BC LPC 63 FCL/FCL

Note: Individual components are available as fully assembled LPCU units rated at 5, 20, 32 & 63 Amps.

Dimensional Drawings Type LPCU

8

Lawson Fuse-Link

Solid Link

LA LA LC LC LD MD ME LA LA LC LC LD MD – ME

SLPC5 SLPC5 SLPC 20 SLPC 20 SLPC 32 SLPC 32 –

DIN rail adaptor LPC 32 DA

SLYDLOK FUSE-HOLDERS

TYPE SLY

List Reference W 5341 FW W 5342 BC W 5344 MM W 5345 BW W 15331 FW W 15332 BC W 15334 MM W 15335 BW W 30341 FW W 30342 BC W 30344 MM W 30345 BW W 60411 FW W 60412 BC W 60414 MM W 60415 BW

Current Rating (A)

Colour

5

15

Lawson Fuse-Link

Wiring Connections

W534

Black

W1533

30

W3034

60

W6041

DIN Rail Adaptor SLYM 3

FW BC MM BW BCT BCB

-

-

Notes: Fuse-holders incorporating fuse-wire, substitute prefix ‘W’ with ‘X’. Details of H range are available on request. Dimensional Drawings Type W and X

Wiring Connections

9

SLYDLOK FUSE-HOLDERS

TYPE SLY

List Reference K 511 FW K 522 BC K 533 MM K 1011 FW KP 1011 FW

Current Rating (A)

Colour

Lawson Fuse-Link

Wiring Connections

5

Black

KCC KDC

FW BC MM

10 10

PCC PDC

DIN Rail Adaptor

-

Notes: Minature Fuse-Links are available to match this range of Fuse-Holders see publication:LFL/PUB/0502 Low Voltage Fuse-Links Page 21. Dimensionally KCC/KDC are 6.3 x 32mm, whereas PCC/PDC are 5 x 20mm.

Dimensional Drawings Type K and KP

Wiring Connections

10

MODULAR FUSE-HOLDERS FOR FUSE-LINKS IN ACCORDANCE WITH IEC 60269 -2

TYPE MS

The MS range of modular fuse-holders offer fuse protection in four popular frame sizes in voltage ratings up to 660 Va.c. Modular fuse-holders accept c ylindrical fuse-links up to a maximum rating of 125 Amps, with principle dimensions of 8.5 x 31.5, 10.3 x 38, 14 x 51 and 22 x 58mm. Conversion kits are available to assemble 2,3 or 4-pole units. List Reference MSC 81 MSC 81 N MSC 101 MSC 101 I MSC 101 N MS 101 MS 101 N MS 141 MS 141 N MS 221 MS 221 N

Current Rating (A)

Dimensions

20

8.5x31.5

Lawson Fuse-Link

Solid Link

LPVG 8

SLLPV 820

LPVG 10

SLLPV 10 32

Colour

(mm)

32

Grey

10.3x38 LPVM 10

50

14x51

125

22x58

LPVG 14 LPVM 14 LPVG 22 LPVM 22

SLLPV 14 50 SLLPV 22 125

I = Indicator, N= Integral Neutral link Modular Fuse-Holder Dimensional Drawings

MSC 8 & 10 Dimensions mm

M SC 8 10

A

B

C

D

E

F

42 77 12 45 17.5 59

MS 10, 14 & 22 Dimensions mm

MS 10 14 22

A B C 43 77 14 52 110 11 52 140 14

D E F 45 17.5 64 45 25 81 45 35 89

11

DOUBLE POLE CUT-OUT

TYPE SLFK

This compact Cut-Out has been designed to comply with the latest requirements of the Wiring Re g u l ations and the El e ctri c i ty at Wo rk Act . It has been rated at 32A, 415Va.c., i n co rporates fully shrouded top te rminals and utilises fuse-links reference F1 to BS88: Pa rt 6

Dimensional Drawings

All dimensions in mm

12

List Reference

Description

SL 32 FK

Cut-Out unit complete with fixed neutral link

Max Cable 16mm2

Max Height Fuse Rating (mm) (Amps) 32

106

Width (mm)

Depth (mm)

64

60

COMPARISON CHARTS

COMPARISON CHART FOR CLIPFIT FUSE-HOLDERS LAWSON REFERENCE LCF32FC/FCBK LCF32FC/BBCBK LCF32FC/BCBK LCF32BC/BCBK LCF32FC/FCWH LCF32FC/BBCWH LCF32FC/BCWH LCF32BC/BCWH LCF63FC/FCBK LCF63FC/BBCBK LCF63FC/BCBK LCF63BC/BCBK LCF63FC/FCWH LCF63FC/BBCWH LCF63FC/BCWH LCF63BC/BCWH

BUSSMANN HAWKER 32NNSF 32NNSFBS 32NNBSBS 32NNSF/W 32NNSFBS/W 32NNBSBS/W 63ENSF 63ENSFBS 63ENBSBS 63ENSF/W 63ENSFBS/W 63ENBSBS/W

GEC ALSTHOM SC32H-D SC32BH SC32P SC32H-D WHITE SC32PWHITE SC63H-D SC63BH SC63P SC63H-D WHITE -

BILL V32FF V32FB V32FFW V32FBW V63FF V63FB V63FFW V63FBW -

COMPARISON CHART FOR BOLTIN FUSE-HOLDERS LAWSON REFERENCE LBI20FC/FCBK LBI20FC/BCBK LBI20BC/BCBK LBI32FC/FCBK LBI32FC/BCBK LBI32BC/BCBK LBI63FC/FCBK LBI63FC/BCBK LBI63BC/BCBK LBI100FC/FCBK LBI100FC/BCBK LBI100BC/BCBK LBI200FC/FCBK LBI200FC/BCBK LBI200BC/BCBK

BUSSMANN HAWKER 32NF CM32FC 32NFBS 32NBS 32AF CM32F 32AFBS 32ABS 63BF CM63F 63BFBS 63BBS 100CF CM100F 100CFBS 100CBS 200DF 200DFBS 200DBS

GEC ALSTHOM RS20H RS20PH RS20P RS32H RS32PH RS32P RS63H RS63PH RS63P RS100H RS100PH RS100P RS200H RS200PH RS200P

BILL

V100FF V100FB V100BB V200FF V200BF V200BB

MEM 20MFB 20MFD 20MFC 32MFB 32MFD 32MFC 63MFB 63MFD 63MFC 100MF 100CFB 100MFC 200MFB 200MFD 200MFC

DORMAN SMITH 32NNF 32NNFB 32NNBS 2AF 32AFBS 32ABS 63BF 63BFBS 63BBS 100CF 100CFBS 100CBS 200DF 200DFBS 200DBS

13