Intraobserver and Interobserver Reliability of a Method to Measure ...

2 downloads 0 Views 227KB Size Report
Context: Physical therapists often have to measure ankle range of motion (ROM) to decide on intervention and investigate improvements. The most common ...
Technical Report 4 Journal of Sport Rehabilitation, 2012 © 2012 Human Kinetics, Inc.

Intraobserver and Interobserver Reliability of a Method to Measure Ankle Plantar-Flexion Range of Motion in the Hook-Lying Position Guilherme S. Nunes, Gabriela S. Bayer, Letícia M.R. da Costa, and Marcos de Noronha Context: Physical therapists often have to measure ankle range of motion (ROM) to decide on intervention and investigate improvements. The most common method of measurement is goniometry, but it has been questioned due to its unsatisfactory levels of reliability. Objective: To investigate the intraobserver and interobserver reliability of a new method of measuring plantar-flexion ROM. Design: Prospective and descriptive. Setting: Laboratory. Participants: 20 healthy participants (12 women and 8 men). Main Outcome Measurements: Ankle plantar flexion was measured by 3 observers (A, B, and C) with 3 methods (goniometry, measurement in hook-lying position [MHP], and static-image analysis [SIA]). Observer A was the most experienced therapist, and C, the least. MHP was performed with the participant in the supine position, knees flexed, and first and fifth metatarsals in contact with the treatment table. SIA was recorded and analyzed in the same position. Goniometry was performed with participant seated, lower legs unsupported, and axis positioned on the lateral malleolus. Results: For the interobserver analysis, the ICC2,1 was high for the MHP (.88), high for SIA (.87), and moderate for goniometry (.57). For the intraobserver analysis, the ICC2,1 was high or very high for MHP (.91–.92), high for SIA (.79–.83), and low to moderate for goniometry (.18–.60). Conclusion: MHP is inexpensive, fast, and more reliable than goniometry for measuring plantar-flexion ROM. Keywords: ankle joint, measurement, goniometry, trigonometry, intraclass correlation coeficient Measurement of joint range of motion (ROM) is often used in physical evaluation routines, usually performed more than once by a single therapist or by more than 1 therapist.1 Therefore, it is important for therapists that the measures be reliable within and between therapists. Reduced ankle ROM is often present as a consequence of sports injury and immobilization, so ROM recovery is always one of the aims of rehabilitation.2 Ultimately, ankle ROM is an important measurement in clinical practice and for research purposes; however, the methods used to perform these measurements have been questioned over the years.3 Previous studies on the reliability of the goniometric measurement for ankle dorsiflexion and plantar flexion present levels of reliability that vary from low to very high (ICC .28–.99)3,4; however dorsiflexion was more frequently investigated than plantar flexion. A literature review published in 20053 found that only 4 studies had investigated the interobserver and intraobserver reliability of goniometric measurement for ankle plantar flexion, with levels of reliability varying from low to very high (ICC .47–.99). Nunes, Bayer, and da Costa are with Santa Catarina State University, Florianópolis, Brazil. de Noronha is with the Rural Health School, La Trobe University, Bendigo, Australia.

Although goniometry is the most common method used to measure ankle ROM, other methods such as staticimage analysis (SIA), have been suggested,5 perhaps due to a lack of evidence on reliability for ankle goniometry. SIA is often performed with the use of a photographic image that is processed by specific computer software to analyze body positioning. The disadvantages of SIA are that it requires specific instruments and longer periods until the measure can be registered, as the image needs to be transferred from a camera to a computer and then processed by computer software. Bennell et al6 investigated the reliability of a trigonometry-based method to measure dorsiflexion ROM that is performed with the participant in closed kinetic chain of the lower limb. This method has been systematically used by other researchers7 due to its levels of reliability (ICC .97–.99) and simplicity—even the calculation of the angle can be achieved by entering 2 sets of numbers in a computerized spreadsheet or specialized internet Web site.8 However, it has been only developed to measure ankle dorsiflexion. Therefore, the aims of the current study were (1) to develop a new method based on positioning the participant in the hook-lying position and extracting the angle by trigonometry to measure plantar flexion and (2) to investigate the reliability of the new method.

1

2  Nunes et al

Methods Participants Twenty healthy students (mean [SD] age 23.2 [3.7] y) took part in the study, and 40 ankles were analyzed. Participants were excluded if they had any ankle or knee injury, within 2 months before the assessments, that prevented them from being in the hook-lying position and performing ankle plantar flexion. The study was approved by the human-research ethics committee of Santa Catarina State University, Florianópolis, Brazil (reference number 12/2010), and all participants signed an informed-consent form before data collection.

motion and asked the participant to sustain the position. The observer then recorded the vertical distance between the highest point on the knee and the treatment table and the horizontal distance between the calcaneus and the projection of the vertical distance (intersection point; Figure 2), forming a 90° angle. Through trigonometry, the right triangle was used to calculate plantar-flexion ROM (Figure 2). Goniometry.  Participants were seated with feet

unsupported and relaxed. The universal goniometer was positioned on the lateral side of the foot, with its axis on the lateral malleolus and using the fibula and the fifth

Observers Three observers took part in the study. Observer A was an experienced physical therapist (over 10 y). Observer B was a physical therapist with intermediate experience (3 y), and observer C was a fourth-year physical therapy student.

Procedures All participants were measured in 2 sessions (test–retest), with a week interval between sessions. For each session, plantar-flexion ROM was measured by all 3 observers with 3 methods. The methods used by each observer were measurement in the hook-lying position (MHP), goniometry, and SIA. The order of observers, ankle, and methods was randomized. The observers were blinded to the scales used in each method; a fourth researcher recorded all measures. Data were revealed to the observers only after the end of data collection. MHP.  MHP was performed with the participant in supine,

knees flexed, and with full contact between the sole of the tested foot and the treatment table. The participant was instructed to slide the foot while extending the knee, keeping the calcaneus and the head of fifth and first metatarsals in contact with the treatment table (Figure 1). The moment the head of the fifth metatarsal lost contact with the treatment table, the observer stopped the sliding

Figure 2 — The measurement in hook-lying position. (A) Sides “a” and “b” of the right triangle, the point of intersection between the sides (Y), and angle α, which represents the maximal range of motion for ankle plantar flexion. (B and C) How the sides were blindly recorded with the use of a tape measure. Angle α was calculated by trigonometry according to the formula tan α = b/a, then the result was transformed from radians to degrees.

Figure 1 — Final position of the foot for measurement in hook-lying position. Position of contact between the (A) first and (B) fifth metatarsals and the treatment table. (C) The moment contact between the fifth metatarsal and the treatment table is lost, at which point the position is held and the range of motion is recorded.

Reliability of a Method to Measure Ankle Plantar Flexion  3

metatarsal as references for passive plantar flexion. The observer applied pressure to the ankle to ensure that full plantar flexion was reached4 (Figure 3). SIA.  SIA was performed in the same position as MHP. The head of the fibula, the lateral malleolus, and the lateral view of the fifth metatarsal were marked to calculate maximal plantar-flexion ROM. The image of the lateral view for each ankle was recorded using a digital camera that was positioned 1 m from the treatment table and 0.85 m above the floor. SIA was performed with Software para Avaliação Postural—SAPO version 0.68.9

Data Analysis All 40 ankles from the 20 participants were used for analysis. Intraclass correlation coefficients (ICC 2,1) with 95% confidence intervals were used to determined intraobserver and interobserver reliability. For intraobserver reliability, data from the first and second sessions (test–retest) were analyzed. For interobserver reliability, the results from the second session were used. To classify the strength of correlation, we used the following scheme: 0 to .25 represents little if any correlation, .26 to .49 low correlation, .50 to .69 moderate correlation, .70 to .89 high correlation, and .90 to 1.00 very high correlation.10 We also calculated the standard error of the measurement (SEM)11 and the minimum detectable change at the 95% confidence level (95% MDC).12,13

Results Table 1 presents the means and SDs for the first and second sessions for each measurement method, and Table 2 presents the results for interobserver and intraobserver reliability and the SEM and MDC for each measurement method.

Discussion The current study presents a trigonometry-based method to measure plantar-flexion ROM that uses the hook-lying position to obtain a consistent measure and compares its reliability levels with those of goniometry and SIA. Our findings regarding the intraobserver reliability for goniometry reinforce the concept that greater observer experience will yield higher levels of reliability. In our study, the observer with less experience and incomplete professional training had low levels of reliability while the experienced observers had moderate reliability (Table 2). In contrast, MHP seems to be a method easily learned, as all 3 observers showed very high reliability for the method. Because goniometry, although inexpensive and fast, frequently presents unsatisfactory levels of reliability, SIA has been considered an alternative to improve reliability when measuring ROM. As SIA and now also MHP seem to be methods that can have their procedures easily standardized, the different levels of difficulty in standardizing the procedures for each method could be the main explanation for the disparity seen between SIA, MHP, and goniometry. In the current study, SIA and goniometry were performed using the same landmarks, and SIA had very high reliability, similar to the reliability seen for the MHP (Table 2). The landmarks used for SIA differed from those used in MHP, but the positioning for both methods was the same. This fact could be

Table 1  Range of Motion (°) Recorded During the First and Second Sessions, Mean ± SD MHP

Goniometry

SIA

  observer A

36.4 ± 5.5

66.9 ± 8.4

68.5 ± 5.8

  observer B

37.5 ± 5.4

70.6 ± 6.2

70.0 ± 5.3

  observer C

38.1 ± 5.2

73.5 ± 6.8

70.7 ± 5.2

  A+B+C

37.3 ± 5.4

70.3 ± 7.7

69.7 ± 5.5

  observer A

36.4 ± 4.9

66.4 ± 8.1

68.8 ± 4.9

  observer B

37.3 ± 5.5

70.2 ± 8.8

69.8 ± 5.5

  observer C

38.5 ± 5.6

69.6 ± 7.7

70.9 ± 5.8

  A+B+C

37.4 ± 5.4

68.7 ± 8.3

69.8 ± 5.4

Session 1

Session 2 Figure 3 — Positioning of participant, the observer’s hands, and the goniometer during measurement of plantar-flexion range of motion by goniometry. The goniometer was positioned with its axis on the lateral malleolus and using the fibula and the fifth metatarsal as references for the goniometer arms. The observer applied pressure to the ankle to guarantee full plantar flexion.

Abbreviations: MHP, hook-lying position; SIA, static-image analysis.

4  Nunes et al

Table 2  Intraclass Correlation Coefficient2,1 (95% CI), Standard Error of the Measurement (SEM)/ Minimal Detectable Change (MDC) for Measurement in Hook-Lying Position (MHP), Goniometry, and Static-Image Analysis (SIA), ° Observer Intraobserver

Interobserver

MHP

Goniometry

SIA

A

.91 (.84–.95), 1.5/4.2

.60 (.36–.77), 5.2/14.4

.81 (.67–.89), 2.3/6.4

B

.91 (.83–.95), 1.6/4.4

.58 (.33–.75), 4.9/13.6

.83 (.71–.91), 2.2/6.1

C

.92 (.86–.96), 1.5/4.2

.18 (-.09–.45), 6.8/18.8

.79 (.63–.88), 2.5/6.9

.88 (.74–.94), 1.9/NA

.57 (.39–.73), 5.5/NA

.87 (.74–.93), 2.0/NA

Note: SEM = SD 1 − ICC2,1 . MDC = z -score × SD × 2(1 − ICC2,1 ).

interpreted as an indication that the landmarks chosen to analyze plantar-flexion ROM are not as important as the development of standardized procedures regarding the positioning, the instruments, and the rationale when measuring plantar-flexion ROM. The final ROM achieved by MHP differed substantially from those with goniometry and SIA. While the literature expects a dorsiflexion ROM close to 20° and plantar flexion close to 50°,4 Bennell et al6 reported dorsiflexion close to 50° with the trigonometry-based measure and the current study presented plantar flexion close to 35°. Therefore, considering that MHP is the complement of the dorsiflexion measurement proposed by Bennell et al,6 if we add the 2 trigonometry-based measures, the total ankle ROM for the sagittal plane will replicate values suggested in the literature.4 It is important to note that the discrepancy found between the ROM measured by MHP and SIA is a consequence of the landmarks used by each method. MHP is not a direct analysis of the bone movement during plantar flexion, but an indirect measure, yet highly reliable. In addition, one may say that the SEMs presented here are a consequence of smaller measured ROM than with goniometry; however, the SEMs for dorsiflexion presented by Bennell et al6 were also smaller than the SEMs reported for goniometry in other studies.3 Overall, the SEMs associated with the trigonometrybased measure were 1.4° for dorsiflexion6 and 1.9° for plantar flexion (current study), while the SEMs associated with the goniometric measure were 4.3° for dorsiflexion3 and 5.5° for plantar flexion (current study). In addition, the 95% MDC analysis reinforces the findings related to ICCs and SEMs, as the lower 95% MDC found for MHP than for goniometry gives us an indication that MHP, as for reliability, is better than goniometry to detect changes (responsiveness). Overall, MHP can be used reliably by one or more therapists to measure plantar-flexion ROM. The method has the advantages of requiring little training and being as inexpensive and fast as goniometry.

Limitations and Future Research Although the MHP presented as a reliable method to measure plantar-flexion ROM, it has only been investigated in a population of healthy adults. Future research

on populations with specific impairments (eg, high arch, fractures, neurological diseases, etc) would further clarify in which situations a therapist could apply this method.

References 1. Elveru RA, Rothstein JM, Lamb RL. Goniometric reliability in a clinical setting: subtalar and ankle joint measurements. Phys Ther. 1988;68(5):672–677. 2. Losito JM, O’Neil J. Rehabilitation of foot and ankle injuries. Clin Podiatr Med Surg. 1997;14(3):533–557. 3. Martin RL, McPoil TG. Reliability of ankle goniometric measurements: a literature review. J Am Podiatr Med Assoc. 2005;95(6):564–572. 4. Norkin C, White D. Measurement of Joint Motion: A Guide to Goniometry. 4th ed. Philadelphia, PA: FA Davis; 2009. 5. Van Maanen CJ, Zonnenberg AJ, Elvers JW, Oostendorp RA. Intra/interrater reliability of measurements on body posture photographs. Cranio. 1996;14(4):326–331. 6. Bennell KL, Talbot RC, Wajswelner H, Techovanich W, Kelly DH, Hall AJ. Intra-rater and inter-rater reliability of a weight-bearing lunge measure of ankle dorsiflexion. Aust J Physiother. 1998;44(3):175–180. 7. Hiller CE, Refshauge KM, Herbert RD, Kilbreath SL. Intrinsic predictors of lateral ankle sprain in adolescent dancers: a prospective cohort study. Clin J Sport Med. 2008;18(1):44–48. 8. Trigonometry Calculator. www.visualtrig.com. Accessed November 26, 2010. 9. Duarte M. Portal do projeto Software para Avaliação Postural. 2004–2010. 10. Domholdt E. Rehabilitation Research: Principles and Applications. 3rd ed. Saint Louis, MO: Elsevier Saunders; 2005. 11. Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998;26(4):217–238. 12. Krause DA, Cloud BA, Forster LA, Schrank JA, Hollman JH. Measurement of ankle dorsiflexion: a comparison of active and passive techniques in multiple positions. J Sport Rehabil. 2011;20(3):333–344. 13. Schmitt JS, Di Fabio RP. Reliable change and minimum important difference (MID) proportions facilitated group responsiveness comparisons using individual threshold criteria. J Clin Epidemiol. 2004;57(10):1008–1018.