VENTILATION FAN CATALOGUE Proven, Reliable Bathroom Ventilation Solutions

Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans. MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens.

PROVEN: Trusted Locally, Proven Globally. RELIABLE: Durable Ball Bearing Motors with a 5 Year Warranty. SOLUTIONS: A Complete Range of Fans, Ducting and Accessories.

Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141 Western Australia

South Australia

Unit 2, 22 Hammond Rd Cockburn Central WA 6164

86A Richmond Rd Keswick SA 5035

Victoria

Queensland

2/13-15 Brough St Springvale VIC 3171

26 Turbo Drive Cooparoo QLD 4151

Tasmania

Newcastle

Electrical Agencies 4 Linear Court Moonah TAS 7009

Nick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322

National Support Centre Phone: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Web: www.manrose.com.au

Manrose continues to lead the way as the “ventilation solution providers” Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans. Thomas and Betts have been supplying the electrical wholesale market for over 35 years and credit their success to outstanding delivery and customer service capabilities and are proud of their strong, long-standing partnerships. They represent the highest quality and most innovative products available. The MANROSE brand is known for proven, reliable solutions with an evolving product range to meet the demands of the market. Thomas & Betts and MANROSE have a strong relationship, which has seen ventilation products developed specifically for the Australian market with features demanded by the customer. This has led to all Manrose products being upgraded with ball bearing motors and a 5 year warranty. Within the Manrose range you can choose from a Classic model which offers trusted performance or a Pro-Series model with higher specifications, installation advantages and features to the contractor, as well as sought after aesthetics demanded by the consumer. A recent addition to the range is Vent-Axia Lo-Carbon range that offer ventilation fans with up to 70% energy savings. The Manrose product development team is consistently developing high quality products with features demanded by the market. Our policy of ongoing investment in product development has been a key force in driving the company to the forefront of the ventilation market. Manrose has an extraction fan for every application. Continual development and innovation ensures that future market demands are not only met but exceeded!

Lo-Carbon PUB0385 Iss03 04/13

contents Ventilation Selection/Regulations

3-9

Selection Chart

10

Ventilation Fans

12-63

Wall/Ceiling Fans

12-21

Thru Wall Fan Kits

22-25

Window Mounted Fans

26-29

Heat/Fan/Light Kits

30-31

In-Line Fan Kits

32-53

Wall Mounted Fans

54-55

Thru-Roof Mounted Fans

56-57

Hand Dryers

58-59

Specialised Fans

60-61

Fan Accessories

62-63

Duct and Fittings

64-79

Duct Standards Ducting Installation & Usage

64 65-71

Aluduct/Comflex Flexible Ducting

72

Unilok 73

Ceiling Diffuser

84-86

Designer Ceiling Diffuser

84

Flat Ceiling Diffuser

84

Ceiling Diffuser

85

Eggcrate Round Diffuser

85

Ceiling Diffuser

86

Cowls/Plate Grilles

87-94

Designer Weatherproof Cowls

87

Weatherproof Cowls

87

Designer Weatherproof Dome

88

Wall/Ceiling Plate Grilles

89

Wall/Ceiling Plate Grilles

89

Door Grille

89

Duct Kits

90-93

Roof Cowls

90-91

Rangehood Ducting Kits

92

Dryer Ducting Kit

93

Pro Series Extension Kit

93

PVC 74

Accessories 94

Semiduct Semi Rigid

Heat Trans

Low Profile Ducting

74 75-78

In-Line

78

Branch Take Off

79

Alpha-Numeric Index Vent-Axia Lo Carbon Range

95-97 98-100 101-104

Reducers 79 Duct Joiners/Spigots

79

Wall/Ceiling Grilles

80-83

Designer Wall Grilles

81

Wall Grilles

81

Wall/Ceiling Grilles

82

Designer Wall/Ceiling Grilles

83

Wall/Ceiling Grilles

83

Technical Information

Product category index

Technical information such as dimensions and size charts can be found beneath or on the page following the product page.

The product category index is an alphanumeric listing of general product groups in the Thomas & Betts portfolio, this can be found on page 98.

2

VENTILATION SELECTION Why you need Ventilation?

• New building materials and construction methods are effectively resulting in “waterproof” buildings. They trap moisture inside just as effectively as they keep moisture out. • Open doors and windows provide air circulation and ventilation but security considerations mean that we are increasingly less likely to use this option. As a result houses tend to remain closed up more often. • Poor ventilation results in a buildup of moisture generated by cooking/bathing/showering/clothes washing- drying/LPG gas heating...even breathing! • Stale air can be caused by cooking smells, odours remaining in the bathroom, a general lack of ventilation around the house as well as a damp atmosphere.

Problems Caused by Poor Ventilation • All these problems cause an avoidable level of discomfort as well as the risk of respiratory illness and general poor health. • Problems also occur when steam from the kitchen or bathroom finds cooler surfaces around the house on which to condense. Warm, moisture-laden air condenses on cold surfaces such as glass, cold ceilings and cold wet-wall linings. This is the moisture that you can see. • Moisture you cannot see is still present in the atmosphere and will be absorbed into fabrics, wall linings, bedding, etc. Attempts to conserve heat by sealing windows and therefore reducing natural ventilation makes this problem even worse. • Condensation can cause considerable problems from peeling wallpaper and mould growth to severe long term structural damage to building materials.

Moisture Generators:

BATHROOM

CONDENSATION

SHOWERING

GAS HEATING

KITCHEN TOILET LAUNDRY

BREATHING WATERING PLANTS

Stale air out

Correct Ventilation

Ventilate Outside = Healthy Home

Incorrect Ventilation

Trapped moist air Inside the home = Unhealthy

In dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly into the roof space is not permitted under the Building Code.

Thomas and Betts | www.manrose.com.au | [email protected]

3

VENTILATION SELECTION Your Ventilation Solutions

Damp air out

It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house.

Fresh air in It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Use ducted fans, through-wall fans or window fans at all times. DO NOT use ceiling fans which discharge into the ceiling cavity, this only moves the problem. Moisture will permeate insulation and ceiling linings causing further problems. In particular with bathrooms think in terms of “room-conditioning”. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel. Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation.

Fan Placement Careful location of an extraction fan will ensure maximum air-flow through the room. Air extracted from a bathroom, for example, can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door. This ensures that fresh air is being drawn into the entire house at regular periods. Switching the fan on before starting showering or cooking sets up effective air-flows before condensation problems occur. Closing doors to adjacent living areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door to replace extracted air. Use a door vent if necessary. For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room. E.g. air in = air out. An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at the bottom), you may need to fit a through-door grille to allow replacement air into the room.

Poor Circulation

4

Medium Circulation

Best Circulation

VENTILATION SELECTION Fan Regulations

What the law states Australian Building Code Paragraph 3.8.5.0 states: Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS 1668.2. “Mechanical ventilation for acceptable indoor air quality”, except that any contaminated air from a sanitary compartment or bathroom must:

a.

Exhaust directly to outside the building by way of ducts; or

b.

Exhaust into the roof space provided:

i.

It is adequately ventilated by open eaves, and/or roof vents; or

ii.

The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles.

As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents. The Manrose range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the latest building code. Natural Ventilation for the above is acceptable as long as opening windows in each room have an area of 5% or more of the floor area of the room.

AS1668 (summarised): “...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces; poisonous or flammable fumes and gases...”

BCA Compliance to AS/NZ 1530 Part 3 Requirements are: Internal Surface:

Spread of flame not >0

External Surface:

Spread of flame not >7



Smoke Developed not >3



Smoke developed not >5

AS/NZS 1530 Part 3 This is the Australian standard 1530, method for fire tests on building materials components and structures. “Simultaneous determination of ignitability, flame propagation, heat release and smoke release”

Bathrooms

Kitchens

The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed.

The regulations require a fan capable of a minimum extraction capacity of 50 litres per second when installed.

Toilets

Laundries

The regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed.

The regulations require a fan capable of a minimum extraction capacity of 20 litres per second when installed.

Thomas and Betts | www.manrose.com.au | [email protected]

5

VENTILATION SELECTION Calculating Fan Performance Litres/Second (l/s) Milk 1 Litre

Working out the right fan for the job • Calculate the room volume in metres (l x W x H).

Cubic Metres/Hour (m³/hr)

1m

• Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit.

1m

• The result is the total performance required in cubic metres per hour. 1m

To convert from one to other types of measurement: If you know Litres/Second (l/s): l/s x 3.6 = m3/hr (e.g. 25 l/s x 3.6 = 90m³/hr). If you know Cubic Metres/Hour (m³/hr): m3/hr ÷ 3.6 = l/s (e.g. 200m³/hr ÷ 3.6 = 55.55 l/s). Note: 1m3 = 1000 Litres ACH

AIR CHANGES PER HOUR (ACH) The number of times the total room volume of air is changed each hour. Refer to the table below for the recommended Air Changes per hour based on the room type.

Select a fan with a higher performance than this figure. For Example: What is the best fan for a bathroom that is 2.8m long by 2.8m wide with a ceiling height of 2.4m?

• Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4 = 18.8m3. • 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m3/hr. • The fan to choose for this bathroom would be a fan that performs at greater than 282m3/hr. • A fan that has a performance level of 313m3/hr or higher (e.g. XP150, or SF150) would do this job.

Application Description

Air Changes Per Hour

Bathrooms

11 - 15

Kitchens - (domestic)

15 - 20

Laundries - (no drier)

6 - 10

Laundries - (with drier)

10 - 30

m³/hr

l/s

m³/hr ÷ 3.6 = l/s

Toilets

6 - 10

cfm

m³/hr

cfm x 1.69 =m³/hr

Bedroom

2-5

cfm

l/s

cfm x 0.47 = l/s

Offices

6 - 10

Cafés

10 - 12

Quick Cross-Reference Calculations: Known

To Find

Action

l/s

m³/hr

l/s x 3.6 =m³/hr

Canteens

8 - 12

350

Garages

6-8

300

Kitchens - (commercial)

20 - 30

250

Restaurants

8 - 12

200

Factories

8 - 10

150

Stores & Warehouses

3-6

Libraries Classroom 6

3-5 5-7

240

110

400

220

100

200

90

180

80

160 70 140 60

120

50

80

30

100

50 0

100

40

m3/hr

60

20

40

10

20 l/s

cfm

m³/hr to l/s to cfm Comparison Chart

VENTILATION SELECTION What Affects Performance? Simple facts: Smaller duct = greater resistance to airflow. More bends = greater resistance to airflow. Longer duct runs = increasingly reduced airflow.

01

Wrinkled ducting causes turbulence and reduces airflow: WRINKLED DUCT AIRFLOW

Compare Centrifugal Against Axial Fan Performance: SF100 (axial) vs an SF200 (centrifugal) fan. The starting point is the free air performance of 23 l/s for the axial and 31 l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases volume of air moved. From the below example you can see that at 20Pa of pressure the 100mm axial fan airflow has stopped whereas the 100mm centrifugal fan is still moving 29 l/s! SF100 & SF200 PERFORMANCE GRAPH*

02

Smoother, extended ducting allows smooth, increased airflow: SMOOTH DUCT AIRFLOW

SF200

SF100 Manrose ALUDUCT flexible ducting retains its stretched-out shape (for smooth airflow) far better than most competitive products.

*Graphs are a visual representation only.

Many competitive ducts tend to shrink back on themselves, wrinkling the duct fabric. ID150 (axial) vs a MAN150 (centrifugal) fan. The starting point is the free air performance of 89 l/s for the axial and 115 l/s for the centrifugal.

Fan type Centrifugal: Pressure developing fans which achieve good flow against the resistance created in a ducted system. Particularly useful in venting areas like internal bathrooms/laundries, multi-room extraction systems, heat-transfer systems, etc. Mixed Flow: Powerful in-duct mounted fans, designed for applications that require high air flows, with low relative noise. Can handle more pressure than an axial fan, although not as powerful as a centrifugal fan. Axial: Suitable for wall, window and roof applications where they can extract directly to the outside. Short duct runs are an option but the length of duct should be limited. e.g.

100mm dia : 2-3m length 125mm dia : 3-4m length 150mm dia : 4-5m length

As duct is added to each of these fans, this increases the pressure (Pa) and decreases the volume of air moved. From the below example you can see that at 120 Pa of pressure the 150mm axial fan airflow has stopped whereas the 150mm centrifugal fan is still moving 102 l/s!

0

72 144 216 288 360 432 504

30

MAN150

25

300 250

20

200

15

150

ID150

10

100 50

5 0

20 40

60 80 100 120 140

*Graphs are a visual representation only.

Thomas and Betts | www.manrose.com.au | [email protected]

7

Wet Areas & Recommended Fan Types When considering where in the room to place an extractor fan, you must consider the wet areas. Zone 1: This is the zone directly within the shower or bath up to 2.25 metres above the floor and 150mm around the bath/ shower cubicle. A SELV fan or an in-line fan kit will be required in this zone.

Zone 1:

Requires a SELV Fan or an In-Line fan kit

For example if a fan is mounted directly over the bath or shower it must be a low voltage fan (SELV).

Zone 2:

Any fan model can be used

Zone 3:

Any fan model can be used

Zone 2: This zone is 0.6 metres horizontally outside of zone 1 and up to 2.25 metres above the floor. Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally outside of zone 2 and 2.25 metres above the floor.

Locate your Ventilation Fan Wet area zone guide

Outside Zones

Outside Zones

Zone 1: Requires a Low Voltage Fan. Zone 2: Any fan model can be used. Zone 3: Any fan models can be used.

How To Order Select the model that exhausts the closest to your requirements. If the performance required falls between two fans, it is recommended you select the one handling the most air.

8

VENTILATION SELECTION Fan Application Examples

Location of your ventilation fan will depend on the physical constraints of your room. The wet area zone guide (shown on the previous page) will help you decide the most suitable physical installation to meet your requirements. Within the above mounting options there are various other features available, such as:

• TIMER (maintain fan run-on after the room is vacated). • PULLCORD (Switch at fan, instead of wall switch control). • AUTO-SHUTTER (electrically operated shutters inside the fan - closed when the fan is not running to stop draughts). • PIR SENSOR (provide automatic motion-sensor control of fans). 1. Ceiling Mounted Fan

4. In-Line Mounted Fan Kit

Designed for low-pitch roofs or between floors, where there is no ceiling access. Also available with heat lamps & lighting.

Most common bathroom installation, the fan is mounted in the ceiling space with the grille directly above the source of the steam. Generally this type of installation is quieter as the fan is not directly in the room.

01

04

Page Reference 12-21

2. Thru Wall Fan Kit Used where the bathroom is on an external wall, or there is no ceiling space for an in-line fan.

Page Reference 32-53

5. Thru Roof Kit

02

Used where there is limited access to the roof space, or where there is no soffit available. Thru Roof Kits can be used with any extraction fan, or use a Thru Roof Fan Kit with the fan mounted within the cowl. Page Reference 22-25 05

3. Window Mounted Fan Used in situations where an existing window fan is being replaced, or where there is no available external wall space and no ceiling space access. 03

Page Reference 56-57

Page Reference 54-55

Thomas and Betts | www.manrose.com.au | [email protected]

9

SELECTION CHART

Selecting the right fan is Easy

Wall/Ceiling Fans

ROOM TYPE

Toilets Laundries - No Dryer Basement Offices These rooms require between 6 and 10 ACH

Bathrooms Showers Ensuites These rooms require between 11 and 15 ACH

Kitchens Laundries - With Dryer These rooms require between 15 and 20 ACH

Thru Wall Fan Kits

Room Size (m3)

VA Lo-Carbon

Pro-Series

Classic

Pro-Series

Classic

1-5m3

LCS150

XFLP125

XF125

XPLP125

XP125

6-10m3

LCS150

XFLP125

XF125

XPLP125

XP125

11-15m3

LCS150

XFLP150

XF150

XPLP150

XP150

1-10m3

LCS150

XFLP150

XF150

XPLP150

XP150

11-15m3

LCS150

XFLP150

XF150

XPLP150

XP150

16-20m3

-

XFLP150

XF150

XPLP150

XP150

21-30m3

-

1-5m3

LCS150

XFLP150

XF150

XPLP150

XP150

6-10m3

-

XFLP150

XF150

XPLP150

XP150

11-20m3

-

XFS230

XPS230

XF230

XPS230

3 Step Selection Guide 01 01

01

02 02 02 03 03

Select your required application, e.g. Bathrooms (11-15 air changes per hour). Calculate the volume of the room in cubic metres (m3) by multiplying the length x width x height E.g. 2.3m x 2.2m x 2.4m = 12.14m3 (Select a room volume 11-15m3).

10

HEAT/FAN/ LIGHT UNITS

IN-LINE FAN KITS

EXTRACT-A-LITE KITS

WINDOW FANS

THRU ROOF FAN KITS

Pro-Series

Pro-Series

Classic

Pro-Series

Classic

Pro-Series

Classic

Heat ‘n Vent 2

SFLP125

SF125

ELLP125

EL100

WF150

HYPER

Heat ‘n Vent 2

SFLP125

SF125

ELLP125

EL125

WF150

HYPER

Heat ‘n Vent 4

SFLP150

SF150

ELLP150

EL150

WF150

HYPER

Heat ‘n Vent 2

SFLP150

SF150

ELLP125

EL150

WF150

HYPER

Heat ‘n Vent 4

SFLP150

SF150

ELLP150

EL150

WF150

HYPER

SFLP150

SF150

ELLP150

EL150

WF150

ULTRA

WF230

ULTRA

MFLP150 SFLP150

SF150

ELLP125

EL150

WF150

HYPER

SFLP150

SF150

ELLP150

EL150

WF150

HYPER

WF230

ULTRA

MFLP150

03

Follow the 12m3 row across and select one of the fan kits available based on your mounting requirements (see top headings and photos). E.g. If you require a Thru Wall Kit then you can choose any of the XP150 or XPLP150 kits. Note: All selections are based on installed fan performance and maximum air change rates (figures in brackets show actual air changes stated if less than maximum).

Thomas and Betts | www.manrose.com.au | [email protected]

11

Manrose PRO-SERIES wall/ceiling mounted fans xflp low profile models Square Models Duct Size

Model No.

Switching Method

Performance 3

Order Code

125mm

XFLP125SS

Standard

36 l/s, 130m /hr

FAN0589

125mm

XFLP125ST

Timer

36 l/s, 130m3/hr

FAN0590

150mm

XFLP150SS

150mm

XFLP150ST

Standard

3

FAN0594

3

FAN0595

87 l/s, 313m /hr

Timer

87 l/s, 313m /hr

Circular Models Duct Size

Model No.

Switching Method

Performance

Order Code

125mm

XFLP125CS

Standard

36 l/s, 130m3/hr

FAN0604

125mm

XFLP150CS

150mm 150mm

Standard

FAN0609

3

FAN0610

87 l/s, 313m /hr 87 l/s, 313m /hr

Timer

XFLP150CT

FAN0605

3

36 l/s, 130m /hr

Timer

XFLP125CT

3

Safety extra low voltage (selv) models Duct Size

Model No.

125mm

XFLP125SLV

125mm 150mm

Performance

Order Code

SELV 12V

36 l/s, 130m3/hr

FAN0591

XFLP125CLV

SELV 12V

36 l/s, 130m3/hr

FAN0606

XFLP150SLV

SELV 12V

87 l/s, 313m3/hr

FAN0596

XFLP150CLV

150mm

Switching Method

SELV 12V

3

87 l/s, 313m /hr

FAN0611

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

Duct Size

Description: Square

Order Code

125mm

Satin Silver Fascia

FAN2069

125mm

Satin Silver Fascia

FAN2068

125mm

Chrome Fascia

FAN0757

125mm

Chrome Fascia

FAN0755

150mm

Satin Silver Fascia

FAN2070

150mm

Satin Silver Fascia

FAN2071

150mm

Chrome Fascia

FAN0613

150mm

Chrome Fascia

FAN0598

• Unique low profile design enables these fans to be installed unobtrusively into any wall or ceiling. • These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. • Supported by a 5 year warranty.

EA

Order Code

LB

Description: Circular

BAL

Duct Size

R

ACCESSORIES

Switching Options 1. Standard Model - operates from remote switch (not supplied).

3. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

NOTE: All fan flow rates quoted are free air delivery.

12

GM

OT O R

5

IN

YEAR WARRANTY

TECHNICAL DATA General information Models

Circular Cut-Out Size

XFLP125S

140mm - Using gib fixing clips supplied/included

XFLP125C

140mm - Using gib fixing clips supplied/included

XFLP150S

173mm - Using gib fixing clips supplied/included

XFLP150C

173mm - Using gib fixing clips supplied/included

DIMENSION INFORMATION (mm) Models

A

B

C

D

XFLP125S

161

122

10

118

XFLP125C

165

122

10

118

XFLP150S

191

122

10

150

XFLP150C

198

122

10

150

Dimensions - XFLP

A

A

A

C

D

B

TECHNICAL SPECIFICATION Models

XFLP125

XFLP150

Power

220 - 240V (SELV models 12V)

220 - 240V (SELV models 12V)

Fan Performance

36 l/s, 130m /hr

87 l/s, 313m3/hr

Fan Wattage

20W

25W

Maximum Pressure

35 Pa

60 Pa

Fan Speed

2000 RPM

2400 RPM

Sound Level

41 dB(A)

40 dB(A)

Max. Operating Temp

50°C

50°C

IP Rating

IPX4

IPX4

Performance - XFLP125

3

Performance - XFLP150

Thomas and Betts | www.manrose.com.au | [email protected]

13

Manrose CLASSIC WALL/CEILING MOUNTED FANS XF Models

STANDARD Models Duct Size 100mm

Model No. XF100S

Switching Method Standard

Performance

Order Code

3

FAN0046

3

23 l/s, 85m /hr

100mm

XF100P

Pull Cord

23 l/s, 85m /hr

FAN0047

100mm

XF100T

Timer

23 l/s, 85m3/hr

FAN0048

3

125mm

XF125S

Standard

36 l/s, 130m /hr

FAN0072

125mm

XF125P

Pull Cord

36 l/s, 130m3/hr

FAN0074

3

125mm

XF125T

Timer

36 l/s, 130m /hr

FAN0075

150mm

XF150S

Standard

87 l/s, 313m3/hr

FAN0120

3

150mm

XF150P

Pull Cord

87 l/s, 313m /hr

FAN0126

150mm

XF150T

Timer

87 l/s, 313m3/hr

FAN0127

150mm

XF150PIR

PIR Control

3

87 l/s, 313m /hr

Standard Model

FAN0124

AUTO SHUTTER Models Duct Size

Model No.

Switching Method

Performance

Order Code

150mm

XF150A

Standard

87 l/s, 313m3/hr

FAN0121

150mm

XF150AP

Pull Cord

87 l/s, 313m3/hr

FAN0122

150mm

XF150AT

Timer

87 l/s, 313m3/hr

FAN0123

Safety extra low voltage (selv) models

Auto Shutter Model

Order Code

100mm

XF100LV

SELV 12V

23 l/s, 85m3/hr

FAN0044

3

125mm

XF125LV

SELV 12V

36 l/s, 130m /hr

FAN0071

150mm

XF150LV

SELV 12V

87 l/s, 313m3/hr

FAN0119

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

Safety Model (SELV)

• Designed for wall or ceiling mounting, these models are efficient and easy to install. • These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. • Supported by a 5 year warranty.

R

Performance

EA

Switching Method

LB

Model No.

BAL

Duct Size

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan.

4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. PIR Model - Motion sensor incorporated in fan. 6. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery

14

GM

OT O R

5

IN

YEAR WARRANTY

TECHNICAL DATA GENERAL INFORMATION Models

Circular Cut-Out Size

XF100

112mm

XF125

135mm

XF150

160mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm)

Dimensions - XF

Models

A

B

C

D

E

XF100

155

98

74

27

155

XF125

168

118

74

27

168

XF150

200

148

74

27

200

XF150PIR

200

148

90

55

200

XF150A/AP

200

148

90

55

200

C

A

B

D

E

TECHNICAL SPECIFICATION Models

XF100

XF125

Power

220 - 240V (LV models 12V)

220 - 240V (LV models 12V) 3

220 - 240V (LV models 12V)

Fan Performance

23/s, 85m /hr

36 l/s, 130m /hr

87 l/s, 313m3/hr

Fan Wattage

20W

20W

25W

Maximum Pressure

20 Pa

35 Pa

60 Pa

Fan Speed

2400 RPM

2000 RPM

2400 RPM

Sound Level

41 dB(A)

41 dB(A)

40 dB(A)

Max. Operating Temp

50°C

50°C

50°C

IP Rating

IPX4

IPX4

IPX4

Performance - XF100

3

XF150

Performance - XF125

Performance - XF150

Thomas and Betts | www.manrose.com.au | [email protected]

15

Manrose CLASSIC WALL/CEILING FANS XFS COMMERCIAL Models

Duct Size Model No. Switching Method

Performance

230mm

152 l/s, 550m3/hr

300mm 300mm

XFS230S XFS300S XFS300S

Standard Standard Standard

Order Code FAN0374

3

FAN2040

3

FAN2040

306 l/s, 1100m /hr 306 l/s, 1100m /hr

AUTO SHUTTER Models Commercial Models

Duct Size

Model No.

Switching Method

Performance

Order Code

3

230mm

XFS230A

Standard

152 l/s, 550m /hr

FAN0346

300mm

XFS300A

Standard

306 l/s, 1100m3/hr

FAN2041

Auto Shutter Models

Manrose Classic THRU WALL FAN KITS XPS COMMERCIAL Models

Duct Size Model No.

Switching Method

Performance

230mm

Standard

152 l/s, 550m3/hr

300mm

XPS230S XPS300S

Standard

Order Code FAN0455

3

306 l/s, 1100m /hr

FAN2042

AUTO SHUTTER Models Commercial Models

Duct Size

Model No.

Switching Method Performance

230mm

XPS230A

Standard

300mm

XPS300A

Standard

Order Code

152 l/s, 550m3/hr 3

306 l/s, 1100m /hr

FAN0348 FAN2043

BAL

LB

EA

R

Auto Shutter Models

GM

OT O R

5

IN

YEAR WARRANTY

16

TECHNICAL DATA GENERAL INFORMATION Models

Fan Cut-Out Size

Exterior Grille

Duct Type

Duct Length

XFS230

265mm

-

-

-

XFS300

310mm

-

-

-

XPS230

265mm

White Fixed Grille

Aluminium Semi-Rigid

375mm

XPS300

310mm

White Fixed Grille

Aluminium Semi-Rigid

375mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

F

G

H

I

XFS230

286

230

141

75

66

-

-

-

-

XFS300

362

300

156

81

75

-

-

-

-

XPS230

286

230

141

75

286

250

375

248

30

XPS300

362

300

156

81

350

230

375

298

50

Dimensions - XF230/300

Dimensions - XPS230/300

C

C

E A

B

E A

G

I

H

F

D

B

A

D

TECHNICAL SPECIFICATION Models

XFS230

XFS300

XPS230

XPS300

Power

220 - 240V

220 - 240V

220 - 240V

220 - 240V

Fan Performance

152 l/s, 550m³/hr

306 l/s, 1100m³/hr

152 l/s, 550m³/hr

306 l/s, 1100m³/hr

Fan Wattage

45W

82W

45W

82W

Maximum Pressure

50 Pa

60 Pa

50 Pa

60 Pa

Fan Speed

1250 RPM

1300 RPM

1250 RPM

1300 RPM

Sound Level

50 dB(A)

60 dB(A)

50 dB(A)

60 dB(A)

Max. Operating Temp

50°C

50°C

50°C

50°C

IP Rating

IPX4

IPX4

IPX4

IPX4

Performance - XFS230

Performance - XFS300

Thomas and Betts | www.manrose.com.au | [email protected]

17

WHISPERVENT CEILING FANS CENTRIFUGAL CEILING FAN MODELS Duct Size

Model No.

Colour

Performance

Order Code

100mm

WVC100W

White

63 l/s, 225m3/hr

FAN0884

100mm

WVC100S

Stainless

63 l/s, 225m3/hr

FAN0885

150mm

WVC150S

White

100 l/s, 360m3/hr

FAN2465

• • • •

Designed for apartments where space is limited, these ceiling mounted fans can be installed in confined spaces. The centrifugal fan design assists‘whisper quiet’ operation. Reliable long lasting ball bearinng motor Supported by a 3 year warranty.

NEW

Simx Whispervent 150 - White

3

YEAR WARRANTY

Simx Whispervent 100 - Silver

2

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied).

18

TECHNICAL DATA

DIMENSION INFORMATION (mm) Models

A

B

C

D

WhisperVent 100

240

290

172

98

WhisperVent 150

310

330

370

37

Dimensions - WhisperVent 100

E

F

184

30

Dimensions - WhisperVent 150

D

A

B

C C

C

A

B

E

D

TECHNICAL SPECIFICATION Models

WhisperVent 100

WhisperVent 150

Power

220 - 240V

220 - 240V 3

Fan Performance

63 l/s, 225m /hr

100 l/s, 360m3/hr

Fan Wattage

30W

42W

Maximum Pressure

105 Pa

145 Pa

Fan Speed

2500 RPM

2500 RPM

Sound Level

38 dB(A)

44 dB(A)

Max. Operating Temp

40 °C

40 °C

IP Rating

IPX4

IPX4

Performance - WhisperVent 100

Performance - WhisperVent 150

Airflow (m³/hr) 0

50

100

150

200

250

300

350

400

160

50

100

150

200

250 140

120

Pressure (Pa)

100

80

60

40

20

15

30

45

60

75

0 0

20

40

60

80

100

120

Airflow (l/s)

Thomas and Betts | www.manrose.com.au | [email protected]

19

Manrose CLASSIC Multi-Vent Fans FLUSH FITTING RANGE

Duct Size Model No.

Switching Method

Performance @ Speed 3

Order Code

100mm

FFCF234S

Standard

65 l/s, 234m3/hr

FAN0038

100mm

FFCF234T

Timer

65 l/s, 234m3/hr

FAN0499

100mm

FFCF234PIR

PIR

65 l/s, 234m3/hr

FAN0501

SURFACE MOUNT RANGE

Flush Fitting Range

Duct Size Model No.

Switching Method

Performance @ Speed 3

Order Code

100mm

SMCF234S

Standard

65 l/s, 234m3/hr

FAN0504

100mm

SMCF234T

Timer

65 l/s, 234m3/hr

FAN0505

• • •

Designed for apartments where space is limited, with a choice of wall or ceiling mounted system. These Models include centrifugal fans with a choice of three in-built speed settings depending on the performance required. Supported by a 2 year warranty.

Manrose CLASSIC WALL FAN CF CENTRIFUGAL MODELS Duct Size Model No.

Switching Method

Performance @ Speed 1

Order Code

100mm

CF200S

Standard

31 l/s, 110m3/hr

FAN0041

100mm

CF200TP

Timer

31 l/s, 110m3/hr

FAN0042 CF Centrifugal Model

• Designed to move air over long distances. • The centrifugal fan design provides efficient airflow and quiet operation. • Supported by a 2 year warranty.

2

YEAR WARRANTY

1. Standard Model - operates from remote switch (not supplied).

3. PIR Model - Motion sensor incorporated in fan. Range up to 5 metres.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

NOTE: All fan flow rates quoted are free air delivery.

20

TECHNICAL DATA

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

F

G

H

Multi-Vent FFCF234

91

96

141

250

15

155

210

-

Multi-Vent SMCF234 312

250

15

119.5

22.5

63

249

-

CF200

65

185

260

45

98

90

135

65

Dimensions - CF200

Dimensions - Multi-Vent (Flush Fitting)

B

Dimensions - Multi-Vent (Surface Mount)

B

C

A

G

E

E

A

C F

C

A

G H

D

D

E

F G

G

D

D

B

TECHNICAL SPECIFICATION Models

Multi-Vent

CF200

1 Speed

2 Speed

3 Speed

Power

220 - 240V

220 - 240V

220 - 240V

220 - 240V

Fan Performance

28 l/s, 100m3/hr

45 l/s, 162m3/hr

65 l/s, 234m3/hr

31 l/s, 110m3/hr

Fan Wattage

40W

80W

110W

45W

Maximum Pressure

140 Pa

165 Pa

180 Pa

120 Pa

Fan Speed

950 RPM

1500 RPM

1850 RPM

1400 RPM

Sound Level

37 dB(A)

51 dB(A)

56 dB(A)

45 dB(A)

Max. Operating Temp

50°C

50°C

50°C

50°C

IP Rating

IPX4

IPX4

IPX4

IPX4

Performance - CF200

Performance - Multi-Vent

Volume m3/hr

0

54

108

162

216

270

60

75

200 180 160

Static Pressure Pa

140 120 100

2

80

3

1

60 40 20 0 0

15

30

45

Volume l/sec

NOTE 1, 2, 3 refer to speed settings controlled by internal switch (not consumer adjustable).

Thomas and Betts | www.manrose.com.au | [email protected]

21

Manrose Pro-Series THRU WALL mounted FAN kits XPLP Low Profile Models STANDARD Models Duct Size Model No. 125mm

XPLP125SS

Switching Method

Performance

Order Code

Standard

36 l/s, 130m3/hr

FAN0614

3

125mm

XPLP125ST

Timer

36 l/s, 130m /hr

FAN0615

150mm

XPLP150SS

Standard

87 l/s, 313m3/hr

FAN0621

150mm

XPLP150ST

Timer

3

87 l/s, 313m /hr

FAN0623

Standard Models

Safety extra low voltage (selv) models Duct Size Model No.

Switching Method

Performance

Order Code

125mm

XPLP125SLV

SELV 12V

36 l/s, 130m3/hr

FAN0620

125mm

XPLP125CLV

SELV 12V

36 l/s, 130m3/hr

FAN0735

3

150mm

XPLP150SLV

SELV 12V

87 l/s, 313m /hr

FAN0732

150mm

XPLP150CLV

SELV 12V

87 l/s, 313m3/hr

FAN0738 Low Voltage Models

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

ACCESSORIES

Satin Silver Fascia

FAN2068

125mm

Chrome Fascia

FAN0755

150mm

Satin Silver Fascia

FAN2071

150mm

Chrome Fascia

FAN0598

Duct Size

Description - Circular

Order Code

125mm

Satin Silver Fascia

FAN2069

125mm

Chrome Fascia

FAN0757

150mm

Satin Silver Fascia

FAN2070

150mm

Chrome Fascia

FAN0613

• • •

The unique Low Profile design enables these fans to be installed unobtrusively into any wall (requires a minimum wall cavity of 110mm). These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

Accessories - Square

Accessories - Circular Fascia

R

125mm

EA

Order Code

LB

Description - Square

BAL

Duct Size

Note 1. Standard Model - operates from remote switch (not supplied).

3. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires permanent phase and switched phase.

NOTE: All fan flow rates quoted are free air delivery.

22

GM

OT O R

5

IN

YEAR WARRANTY

Technical data GENERAL INFORMATION Models

Fan Cut-Out Size

Exterior Grille

Duct Type

Duct Length

XPLP125

140mm

White Gravity Shutter

Aluminium Semi-Rigid

375mm

XPLP150

173mm

White Gravity Shutter

Aluminium Semi-Rigid

375mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

F

G

H

I

XPLP125

161

118

128

10

160

125

375

123

30

XPLP150

191

150

132

10

174

150

375

148

30

Dimensions - XPLP

I E

G H

F

B

A

C

D

TECHNICAL SPECIFICATION Models

XPLP125

XPLP150

Power

220 - 240V (LV models 12V)

220 - 240V (LV models 12V)

Fan Performance

36 l/s, 130m /hr

87 l/s, 313m3/hr

Fan Wattage

20W

25W

Maximum Pressure

35 Pa

60 Pa

Fan Speed

2000 RPM

2400 RPM

Sound Level

41 dB(A)

40 dB(A)

Max. Operating Temp

50°C

50°C

IP Rating

IPX4

IPX4

Performance - XPLP125

3

Performance - XPLP150

Thomas and Betts | www.manrose.com.au | [email protected]

23

Manrose CLASSIC THRU WALL MOUNTED FAN KITS XP Models

STANDARD Models Duct Size

Model No.

Switching Method

Performance

Order Code

100mm

XP100S

Standard

23 l/s, 85m3/hr

FAN0053

100mm 100mm 125mm

XP100P XP100T XP125S

3

Pull Cord

23 l/s, 85m /hr

FAN0054

3

Timer

23 l/s, 85m /hr

Standard

FAN0055

3

FAN0080

3

36 l/s, 130m /hr

125mm

XP125P

Pull Cord

36 l/s, 130m /hr

FAN0082

125mm

XP125T

Timer

36 l/s, 130m3/hr

FAN0083

150mm 150mm 150mm

XP150S XP150P XP150T

Standard

3

FAN0135

3

FAN0140

3

FAN0141

87 l/s, 313m /hr

Pull Cord

87 l/s, 313m /hr

Timer

87 l/s, 313m /hr

Standard Models

AUTO SHUTTER Models Order Code

150mm

XP150A

Standard

87 l/s, 313m3/hr

FAN0136

150mm 150mm

XP150AP XP150AT

Pull Cord Timer

3

FAN0137

3

FAN0138

87 l/s, 313m /hr 87 l/s, 313m /hr

Safety extra low voltage (selv) models Duct Size

Model No.

Switching Method

Performance

Order Code

100mm

XP100LV

SELV 12V

25 l/s, 85m3/hr

FAN0409

3

125mm

XP125LV

SELV 12V

36 l/s, 130m /hr

FAN0410

150mm

XP150LV

SELV 12V

87 l/s, 313m3/hr

FAN0411

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

• • •

These fans are designed to be ducted straight through an exterior wall and are efficient and easy to install. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

Auto Shutter Models

Low Voltage Models

R

Performance

EA

Switching Method

LB

Model No.

BAL

Duct Size

Note 1. Standard Model - operates from remote switch (not supplied).

3. Pull Cord Model - Integral pull cord switch on fan.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

24

GM

OT O R

5

IN

YEAR WARRANTY

Technical data GENERAL INFORMATION Models

Fan Cut-Out Size

Exterior Grille

Duct Type

Duct Length

XP100

112mm

Grey Gravity Shutter

Aluminium Semi-Rigid

375mm

XP125

135mm

Grey Gravity Shutter

Aluminium Semi-Rigid

375mm

XP150

160mm

Grey Gravity Shutter

Aluminium Semi-Rigid

375mm

Please note: Fan cut out size is a nominal diameter.

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

F

G

H

I

XP100

155

98

74

27

138

100

375

98

30

XP125

168

118

74

27

160

125

375

123

30

XP150

200

148

74

27

174

150

375

148

30

XP150A

200

148

90

55

174

150

375

148

30

Dimensions - XP

C I

E

D

G H

F

B

A

TECHNICAL SPECIFICATION Models

XP100

XP125

XP150

Power

220 - 240V (SELV models 12V)

220 - 240V (SELV models 12V)

220 - 240V (SELV models 12V)

Fan Performance

23 l/s, 85m³/hr

36 l/s, 130m³/hr

87 l/s, 313m³/hr

Fan Wattage

20W

20W

25W

Maximum Pressure

20 Pa

35 Pa

60 Pa

Fan Speed

2400 RPM

2000 RPM

2400 RPM

Sound Level

41 dB(A)

41 dB(A)

40 dB(A)

Max. Operating Temp

50°C

50°C

50°C

IP Rating

IPX4

IPX4

IPX4

Performance - XP100

Performance - XP125

Performance - XP150

Thomas and Betts | www.manrose.com.au | [email protected]

25

Manrose CLASSIC WINDOW MOUNTED FANS WF Models

STANDARD Models Duct Size Model No.

Switching Method

Performance

Order Code

100mm

WF100P

Pull Cord

23 l/s, 85m3/hr

FAN0021

100mm

WF100PLV

Low Voltage

23 l/s, 85m3/hr

FAN0452

Manual SHUTTER Models Standard Models

Duct Size Model No.

Switching Method

Performance

Order Code

150mm

WF150MP

Pull Cord

87 l/s, 313m3/hr

FAN0110

150mm

WF150MPLV

SELV 12

87 l/s, 313m3/hr

FAN0355

Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).

AUTO SHUTTER Models Duct Size Model No.

Switching Method

Performance

Order Code

150mm

WF150AP

Pull Cord

87 l/s, 313m3/hr

FAN0107

150mm

WF150APT

Pull Cord Timer

87 l/s, 313m3/hr

FAN0109

Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are Supported by a 5 year warranty.

Auto Shutter Models

BAL

LB

EA

R

• •

GM

OT O R

5

IN

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan.

4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. Manual Pull cord - Pull cord operates fan and manual shutters. 6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

26

Technical data GENERAL INFORMATION Models

Glass Cut-Out Size

WF100

115mm - 155mm

WF150

165mm - 190mm

Please note: Glass cut out size is a nominal diameter for a circular cut-out.

DIMENSION INFORMATION (mm) Models

A

B

C

Dimensions - WF

B

D

WF100

163

90

30

163

WF150

203

118

23

203

A

C

D

TECHNICAL SPECIFICATION Models

WF100

WF150

Power

220 - 240V

220 - 240V (SELV models 12V)

Fan Performance

23 l/s, 85m³/hr

87 l/s, 313m³/hr

Fan Wattage

20W

25W

Maximum Pressure

20 Pa

60 Pa

Fan Speed

2400 RPM

2400 RPM

Sound Level

41 dB(A)

40 dB(A)

Max. Operating Temp

50°C

50°C

IP Rating

IPX4

IPX4

Performance - WF100

Performance - WF150

Thomas and Betts | www.manrose.com.au | [email protected]

27

Manrose CLASSIC WINDOW COMMERCIAL FANS WF Commercial MODELS Standard Models Duct Size Model No. Switching Method

Performance

Order Code

230mm

WF230P

Pull Cord

152 l/s, 550m3/hr

FAN0148

300mm

WF300P

Pull Cord

306 l/s, 1100m3/hr

FAN0481

AUTO SHUTTER Models Standard Larger Models

Duct Size Model No. Switching Method

Performance

Order Code

230mm

WF230AP

Pull Cord

152 l/s, 550m3/hr

FAN0146

300mm

WF300A

Standard

306 l/s, 1100m3/hr

FAN0482

• •

Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are Supported by a 5 year warranty.

Auto Shutter Models

Manrose CLASSIC WINDOW COMMERCIAL FANS COM Commercial Models Duct Size Model No.

Switching Method

Performance

Order Code

230mm

COM230A

Standard

185 l/s, 670m3/hr

FAN0519

230mm

COM230MP Pull Cord

185 l/s, 670m3/hr

FAN0518

300mm

COM300A

Standard

280 l/s,1020m3/hr

FAN0521

300mm

COM300MP Pull Cord

280 l/s,1020m3/hr

FAN0520

Commercial Auto Shutter Models

BAL

LB

EA

R

• Designed for commercial applications such as pubs, restaurants, hotels, shops etc. • These axial fans include ball bearing motors to prolong the life of the motor. • Supported by a 5 year warranty.

GM

OT O R

5

IN

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pull cord switch on fan.

4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts. 5. Manual Pull cord - Pull cord operates fan and manual shutters. 6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.

28

Technical data GENERAL INFORMATION Models

Glass Cut-Out Size

WF230

255mm - 270mm

WF300

310mm - 345mm

COM230

255mm - 270mm

COM300

310mm - 345mm

Dimensions - WF230/300

C

B

Please note: Glass cut out size is a nominal diameter for a circular cut-out.

A

DIMENSION INFORMATION (mm)

D

E

Dimensions - COM230/300

Models

A

B

C

D

E

WF230

286

286

4-32

112

25

WF300

362

362

4-32

133

29

COM230

286

125

25

154

-

COM300

362

145

25

170

-

A

B

A D C

TECHNICAL SPECIFICATION Models

WF230

Power

220 - 240V

WF300

COM230

220 - 240V 3

COM300

220 - 240V 3

220 - 240V 3

Fan Performance

152 l/s, 550m /hr

306 l/s, 1100m /hr

185 l/s, 670m /hr

280 l/s, 1020m3/hr

Fan Wattage

45W

82W

45W

82W

Maximum Pressure

50 Pa

60 Pa

50 Pa

60 Pa

Fan Speed

1250 RPM

1300 RPM

1600 RPM

1300 RPM

Sound Level

50 dB(A)

60 dB(A)

53 dB(A)

60 dB(A)

Max. Operating Temp

50°C

50°C

50°C

50°C

Performance - WF230

Volume m 3/hr 0

250

500

750

Performance - WF300

Performance - COM230

Volume m 3/hr 300

600

900

1200

1500

0

83

168

250

333

416

Performance - COM300

55 Static Pressure Pa

Static Pressure Pa

55

0

40

40

25

25

0

0 0

70

140 Volume l/sec

210

Volume l/sec

Thomas and Betts | www.manrose.com.au | [email protected]

29

Manrose PRO-SERIES HEAT/FAN/LIGHT KITS Heat ‘n Vent Models Duct Size Model No.

Performance

Order Code

125mm

Heat ‘n Vent 4

60 l/s, 216m3/hr

FAN0995

125mm

Heat ‘n Vent 2

50 l/s, 180m3/hr

FAN0940

ACCESSORIES

Pro-Series Heat ‘n Vent 4

Duct Size Description

Order Code

125mm

Heat ‘n Vent 4 Silver Fascia

FAN1015

125mm

Heat ‘n Vent 2 Silver Fascia

FAN1014

275W Heat Lamp

LHT0081

50W Halogen GU10 lamp

LHT0140 Pro-Series Heat ‘n Vent 2

• • •

With a 40% increase in performance* these systems meet the demands of larger bathrooms and the stylish fascia blends into the decor. These high efficiency centrifugal fans incorporate a unique anti-condensate design feature. Supported by a 5 year warranty.

Manrose CLASSIC Heat/FAN/LIGHT KIT Heat ‘n Vent 2

Duct Size Model No.

Performance

Order Code

100mm

35 l/s, 126m3/hr

FAN2162

Heat ‘n Vent 2

• This system delivers instant heat combined with ventilation and soft lighting to create a comfort area in small bathrooms. • Supported by a 5 year warranty.

Classic Heat ‘n Vent 2

Manrose CLASSIC Heat/LIGHT KIT 2 Heat ‘n LIGHT

• This system provides instant heat and additional lighting. • For a complete bathroom solution an extraction fan can be added. • Supported by a 5 year warranty.

2 Heat ‘n Light R

FAN2200

2 Heat ‘n Light (excludes fan)

EA

100mm

LB

Order Code

BAL

Duct Size Description

GM

OT O R

5

IN

YEAR WARRANTY

(Excludes Lamps) Switching Options 1. Standard Model - operates from remote switch (not supplied). *Increase in performance is based on the comparison to the previous models.

30

NOTE: All fan flow rates quoted with 3 metres of duct, one bend and one external grille (normal installation).

Technical data GENERAL INFORMATION Models

Cut-Out Size

Exterior Grille

Duct Type

Duct Length

PS Heat ‘n Vent 4

300mm x 300mm

White Eggcrate

Aluminium

3m supplied (you can add up to 3m extra duct)

PS Heat ‘n Vent 2

390mm x 210mm

White Eggcrate

Aluminium

3m supplied (you can add up to 3m extra duct)

Classic Heat ‘n Vent 2 390mm x 220mm

White Eggcrate

Aluminium

3m supplied (you can add up to 3m extra duct)

Classic Heat ‘n Light

-

-

-

390mm x 220mm

DIMENSION INFORMATION (mm) Models

A

B

C

D

PS Heat ‘n Vent 4

338

338

170

120

PS Heat ‘n Vent 2

435

260

185

120

Heat ‘n Vent

450

250

195

100

Heat ‘n Light

450

250

195

100

Dimensions - PS Heat ‘n Vent 2

Dimensions - PS Heat ‘n Vent 4

Dimensions - Classic Heat ‘n Vent

D C

B

A

Dimensions - Classic 2 Heat ‘n Light

D

D C

C

C

B

B

B A

A

TECHNICAL SPECIFICATION Models

PS Heat ‘n Vent 4

PS Heat ‘n Vent 2

Heat ‘n Vent 2

2 Heat ‘n Light

Power

220 - 240V

220 - 240V

220 - 240V

220 - 240V

Fan

Centrifugal

Centrifugal

Centrifugal

-

Fan Performance

60 l/s, 216m³/hr

50 l/s, 180m³/hr

35 l/s, 126m³/hr

-

Heat Lamps

4 x 275W

2 x 275W

2 x 275W

2 x 275W

Light

GU10 Halogen

GU10 Halogen

GLES

GLES

Total Wattage

1180W

635W

670W

650W

Light Wattage

50W

50W

100W

100W

Switch Plate

4 sw. (supplied)

3 sw. (supplied)

3 sw. (supplied)

2 sw. (supplied)

Warranty

5 Years

5 Years

5 Years

5 Years

Performance Graph

Icon Key 36

72

108 144

03

180

02

216

252

01

288

01

Pro-Series Heat ‘n Vent 4

02

Pro-Series Heat ‘n Vent 2

03

Classic Heat 'n Vent 2

Note: Performance tested in free air. 70

Thomas and Betts | www.manrose.com.au | [email protected]

31

PRO-SERIES IN-LINE MOUNTED FAN KITS MIXFLO™ Shower Fan Models Duct Size Model No.

Switching Method

Performance

Order Code

100mm

Standard

69 l/s, 250m3/hr

FAN2049

150mm

MFLP125S MFLP150S

Standard Standard

3

89 l/s, 320m /hr 3

166 l/s, 597m /hr

FAN2050 FAN2051 MKLP150

BAL

LB

EA

• These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. • Supported by a 5 year warranty.

R

125mm

MFLP100S

Grille Cut-Out

Interior Grille

Exterior Grille

MFLP100 115mm

White Low Profile

White Low Profile Unilok Nude

6m supplied (you can add up to 6m extra duct)

MFLP125 140mm

White Low Profile

White Low Profile Unilok Nude

6m supplied (you can add up to 6m extra duct)

MFLP150 160mm

White Low Profile

White Low Profile Unilok Nude

6m supplied (you can add up to 6m extra duct)

Please note: Grille cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied).

32

OT O R

YEAR WARRANTY

GENERAL INFORMATION (KITS) Models

GM

5

IN

Duct Type

Duct Length

Technical data

Dimension INFORMATION (mm) Models

A

B

C

D

E

F

G

MF100

98

182

315

100

100

168

27

MF125

122

182

350

100

100

168

60

MF150

147

209

360

130

115

195

55

Dimensions - MF

TECHNICAL SPECIFICATION Model No

Size (mm)

MF100

100

MF125

125

MF150

150

RPM Watts

Maximum Airflow (m³/hr)

Maximum Pressure (Pa)

2300

40

250

180

1700

18

190

120

2300

40

320

220

1700

18

260

160

2700

70

597

300

2000

60

330

240

Performance - MF100

50

100

150

IP Rating

Max Operating Temp °C

40

X4

45

43

X4

45

47

X4

60

Performance - MF125

Airflow (m3/hr) 0

Lp dB(A) 3m*

Performance - MF150

Airflow (m3/hr) 200

250

300

0

50

100

150

Airflow (m3/hr)

200

250

300

0

350

250

200

200

300

400

500

600

700

350

180

300 200

160

250

140 120 100 80

Pressure (Pa)

150

Pressure (Pa)

Pressure (Pa)

100

100

200 150 100

60 50

40

50

20 0

0 0

20

40

60

0 0

80

20

Airflow (L/s)

40

60

80

Airflow (L/s)

100

0

50

100

150

200

Airflow (L/s)

* Lp dB(A) @ 3 metres - sound pressure based on the high speed for each fan.

SOUND POWER LEVEL (high speed) Model No

Sound Power Levels Lw (dB) Octave band centre frequency in Hz

LwA dB(A)

125

250

500

1000 2000 4000 8000

MF100

50

56

58

58

52

47

37

61

MF125

52

59

60

60

56

49

41

63.5

MF150

58

66

65

63

62

54

46

67.5

Thomas and Betts | www.manrose.com.au | [email protected]

33

Manrose PRO-SERIES IN-LINE FANS KITS SFLP Shower Fan Models

Model No.

Switching Method

Fan Type

Performance

Order Code

125mm

SFLP125S

Standard

Ctr’fgl

39 l/s, 140m³/hr

FAN0616

125mm

SFLP125T

Timer

Ctr’fgl

39 l/s, 140m³/hr

FAN0617

150mm

SFLP150S

Standard

Whisper

94 l/s, 340m³/hr

FAN0618

150mm

SFLP150T

Timer

Whisper

94 l/s, 340m³/hr

FAN0619

SFLP150

BAL

LB

EA

R

Duct Size

GM

OT O R

5

IN

YEAR WARRANTY

• These high efficiency in-line fans are designed to provide higher levels of extraction for today’s larger bathrooms. • Supported by a 5 year warranty.

General INFORMATION

Models

Grille Cut-Out

Interior Grille

Exterior Grille

Duct Type

Length of Duct included

SFLP125 140mm

White Low Profile

White Low Profile

Flexible Aluminium

4m supplied (can be extended up to 6m)

SFLP150 160mm

White Low Profile

White Low Profile

Flexible PVC

5m supplied (can be extended up to 12m)

Please note: Grille cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include

34

a fixed 7 minute timer. Both require three wires: permanent phase, switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

Technical data

Dimension INFORMATION (mm) Models

A

B

C

D

E

SFLP125

155

125

125

195

258

SFLP150

200

143

170

185

-

Dimensions - SFLP125

Dimensions - SFLP150

C

A B

A

C

D

B

D

E

TECHNICAL SPECIFICATION Models

SFLP125

SFLP150

Fan

CFD225

WhisperVent

Power

220 - 240V

220 - 240V

Fan Performance

39 l/s, 140m³/hr

94 l/s, 340m³/hr

Fan Wattage

20W

46W

Maximum Pressure

120 Pa

160 Pa

Fan Speed

1400 RPM

2750 RPM

Sound Level

45 dB(A)

38 dB(A)

Max. Operating Temp

50°C

80°C

IP Rating

IPX4

IPX2

Performance - SFLP125

Performance - SFLP150

36

72

108 144

180

216

252

70

288

324 360

90

Thomas and Betts | www.manrose.com.au | [email protected]

35

Manrose CLASSIC IN-LINE FAN KITS SF Shower Fan Models Model No.

Switching Method

Fan Type

Performance

Order Code

100mm

SF100S

Standard

Axial

23 l/s, 85m3/hr

FAN0017

100mm

SF100T

Timer

Axial

23 l/s, 85m3/hr

FAN0018

100mm

SF200S

Standard

Ctr’fgl

31 l/s, 110m3/hr

FAN0328

100mm

SF200T

Timer

Ctr’fgl

31 l/s, 110m3/hr

FAN0329

125mm

SF125S

Standard

Axial

36 l/s, 130m3/hr

FAN0064

125mm

SF125T

Timer

Axial

36 l/s, 130m3/hr

FAN0065

150mm

SF150S

Standard

Axial

87 l/s, 320m3/hr

FAN0101

150mm

SF150T

Timer

Axial

87 l/s, 320m3/hr

FAN0102

SF150 Shower Fan Kit

• • •

BAL

LB

EA

R

Duct Size

GM

YEAR WARRANTY

With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from source. These fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

GENERAL INFORMATION Duct Type

Models

Grille Cut-Out

Interior Grille

Exterior Grille

SF100

115mm

White Circular

White Fixed Louvre Flexible PVC

3m supplied (should not be extended)

SF200

115mm

White Circular

White Fixed Louvre Flexible Alum

3m supplied (can be extended up to 6m)

SF125

140mm

White Circular

White Fixed Louvre Flexible PVC

4m supplied (should not be extended)

SF150

160mm

White Circular

White Fixed Louvre Flexible PVC

5m supplied (can be extended up to 12m)

Length of Duct included

Please note: Grille cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied).

a fixed 7 minute timer. Both require: permanent phase and switched phase.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include

NOTE: All fan flow rates quoted are free air delivery.

36

OT O R

5

IN

Performance will be affected by the length of ducting used.

Technical data

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

SF100

130

155

90

100

27

SF200

155

100

100

195

258

SF125

150

155

99

118

27

SF150

187

153

109

150

27

TECHNICAL SPECIFICATION Models

SF100

SF200

SF125

SF150

Fan

ID100

CFD200

ID125

Hyper

Power

220 - 240V

220 - 240V

220 - 240V

220 - 240V

Fan Performance

23 l/s, 85m³/hr

31 l/s, 110m³/hr

36 l/s, 130m³/hr

89 l/s, 320m³/hr

Fan Wattage

20W

20W

20W

38W

Maximum Pressure

20 Pa

120 Pa

35 Pa

135 Pa

Fan Speed

2400 RPM

1400 RPM

2000 RPM

2650 RPM

Sound Level

41 dB(A)

45 dB(A)

41 dB(A)

46 dB(A)

Max Operating Temp

50°C

50°C

50°C

70°C

IP Rating

IPX4

IPX4

IPX4

IPX2

Performance - SF100

Performance - SF125

Dimensions - SF100/SF125/150

C D

A

E

B Dimensions - SF200

B

A

C

D

E Performance - SF200

Performance - SF150 Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used.

Thomas and Betts | www.manrose.com.au | [email protected]

37

Manrose PRO-SERIES IN-LINE FAN/LIGHT KITS ELLP Extract-a-lite Low Profile Models

Duct Size

Model No.

Switching Method

Performance

Order Code

125mm

ELLP125WS - Wht

Standard

39 l/s, 140m3/hr

FAN2029

125mm

ELLP125WT - Wht

Timer

39 l/s, 140m3/hr

FAN2031

125mm 125mm

ELLP125SS - Slv ELLP125ST - Slv

Standard Timer

3

FAN2030

3

FAN2032

3

39 l/s, 140m /hr 39 l/s, 140m /hr

150mm

ELLP150WS - Wht

Standard

94 l/s, 340m /hr

FAN2033

150mm

ELLP150WT - Wht

Timer*

94 l/s, 340m3/hr

FAN2035

150mm 150mm

ELLP150SS - Slv ELLP150ST - Slv

Standard Timer*

3

FAN2034

3

FAN2036

94 l/s, 340m /hr 94 l/s, 340m /hr

ELLP125SW

* Includes a 7 minute fixed timer

These high efficiency in-line fans are designed to provide higher levels of extraction for larger bathrooms and include a stylish downlight. White or satin silver finish available to complement your bathroom decor. Electronic Transformer included in the kit to operate the 12V downlight. Supported by a 5 year warranty.

LB

EA

R

ELLP150SS

BAL

• • • •

ACCESSORIES

GM

OT O R

5

IN

YEAR WARRANTY

Duct Size

Description

Order Code

125mm

Pro-Series ELLP Diffuser White incl lamp

DCT1519

125mm

Pro-Series ELLP Diffuser Silver incl lamp

DCT1520

150mm

Pro-Series ELLP Diffuser White incl lamp

DCT1521

150mm

Pro-Series ELLP Diffuser Silver incl lamp

DCT1522

12V 35-50W Dichroic lamp with 60˚ angle beam

FAN0431

Electronic Transformer 12VAC 50kHz

FAN2101

125mm ELLP Diffusers

GENERAL INFORMATION Models

Diffuser Cut-Out

Interior

Exterior Grille

Duct Type

Length of Duct included

ELLP125W

140mm

White Extract-a-lite incl light

White Low Profile

Black Unilok

6m supplied (you can add up to 6m extra duct)

ELLP125SS 140mm

Satin Silver Extract-a-lite incl light

White Low Profile

Black Unilok

6m supplied (you can add up to 6m extra duct)

ELLP150W

White Extract-a-lite incl light

White Low Profile

Black Unilok

6m supplied (you can add up to 6m extra duct)

Satin Silver Extract-a-lite incl light

White Low Profile

Black Unilok

6m supplied (can be extended up to 12m)

165mm

ELLP150SS 165mm

Please note: Diffuser cut out size is a nominal diameter for a circular cut-out. Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include

38

a fixed 7 minute timer. Both require: permanent phase, and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

Technical data

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

F

G

H

ELLP125

155

125

125

195

258

165

80

110

ELLP150

200

143

170

185

-

200

80

148

Dimensions - ELLP125 Fan

Dimension - ELLP150 Fan

Dimensions - ELLP Extract-a-lite Diffuser

C

A B

A

C

D

H

B

G

D F

E

TECHNICAL SPECIFICATION Models

ELLP125

ELLP150

Fan

CFD225

WhisperVent

Power

220 - 240V

220 - 240V

Fan Performance

39 l/s, 140m³/hr

94 l/s, 340m³/hr

Fan Wattage

20W

46W

Maximum Pressure

120 Pa

160 Pa

Fan Speed

1400 RPM

2750 RPM

Light

12V 50W Halogen

12V 50W Halogen

Total Wattage

99W

96W

Sound Level

45 dB(A)

38 dB(A)

Max. Operating Temp

50°C

80°C

IP Rating

IPX4

IPX2

Performance - ELLP125

Performance - ELLP150

36

72

108 144

180

216

252

70

288

324 360

90

Thomas and Betts | www.manrose.com.au | [email protected]

39

Manrose CLASSIC IN-LINE FAN/LIGHT KITS EL Extract-a-lite Models

EL100S

Standard

100mm

EL100T

125mm

Timer

EL125S

Standard

31 l/s, 110m3/hr

FAN0420

3

FAN0438

3

FAN2037

3

31 l/s, 110m /hr 36 l/s, 130m /hr

125mm

EL125T

Timer

36 l/s, 130m /hr

FAN2038

150mm

EL150S

Standard

89 l/s, 320m3/hr

FAN0803

150mm

EL150T

Timer*

89 l/s, 320m3/hr

FAN0804

EL150S

R

100mm

Order Code

EA

Switching Method Performance

LB

Model No.

BAL

Duct Size

OT O R

YEAR WARRANTY

* Includes a 7 minute fixed timer.

• • • •

GM

5

IN

The fan is mounted in the ceiling space, and is therefore able to draw steam directly from source, while at the same time providing spot lighting within your bathroom. These fans have been upgraded with ball bearing motors to prolong the life of the motor. Electronic Transformer included in the kit to operate the 12V downlight. Supported by a 5 year warranty.

ACCESSORIES EL Diffuser white incl lamp

DCT0360

100mm

EL Diffuser chrome incl lamp

DCT0362

125mm

EL Diffuser white incl lamp

DCT2121

125mm

EL Diffuser chrome incl lamp

DCT2120

150mm

EL Diffuser white incl lamp

DCT1169

150mm

EL Diffuser chrome incl lamp

DCT1171

100mm

Accessory chrome bezel - Extract-a-lite

DCT0366

125mm

Accessory chrome bezel - Extract-a-lite

FAN2076

150mm

Accessory chrome bezel - Extract-a-lite

FAN0827

12V 35-50W Dichroic lamp with 60˚ angle beam

FAN0431

Electronic Transformer 12VAC 50kHz

125mm EL Diffusers

R

100mm

EA

Order Code

LB

Description

BAL

Duct Size

GM

OT O R

5

IN

YEAR WARRANTY

FAN2101

GENERAL INFORMATION Models

Diffuser Cut-Out

Interior

Exterior Grille Duct Type

Length of Duct included

EL100

115mm

White Extract-a-lite incl light

White Eggcrate

Flexible PVC

3m supplied (should not be extended)

EL125

145mm

White Extract-a-lite incl light

White Eggcrate

Flexible PVC

4m supplied (should not be extended)

EL150

165mm

White Extract-a-lite incl light

White Eggcrate

Flexible PVC

5m supplied (you can add up to 12m extra duct)

Please note: Diffuser cut out size is a nominal diameter for a circular cut-out.

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models

40

include a fixed 7 minute timer. Both require: permanent phase and switched phase. NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.

Technical data

DIMENSION INFORMATION (mm) Models

A

B

C

D

E

F

G

H

EL100

130

155

90

100

27

140

74

98

EL125

150

155

99

118

27

170

74

118

EL150

200

143

170

185

200

74

148

Dimensions - EL125

Dimensions - EL100

Dimensions - EL150 Fan

A

B

C

D

C

A

C D

A

B

E

B

D

E

TECHNICAL SPECIFICATION Models

EL100

EL125

EL150

Fan

CFD200

ID125

Hyper

Power

220 - 240V

220 - 240V

220 - 240V

Fan Performance

31 l/s, 110m3/hr

36 l/s, 130m3/hr

89 l/s, 320m3/hr

Fan Wattage

20W

25W

38W

Maximum Pressure

120 Pa

35 Pa

135 Pa

Fan Speed

1400 RPM

2000 RPM

2650 RPM

Light

12V 50W Halogen

12V 50W Halogen

12V 50W Halogen

Total Wattage

70W

75W

88W

Sound Level

45 dB(A)

41 dB(A)

46 dB(A)

Max. Operating Temp

40°C

40°C

70°C

IP Rating

IPX4

IPX4

IPX2

Performance - EL100

Performance - EL125

Dimensions - EL Extract-a-lite Diffuser

H G

F

Performance - EL150

36

72

108 144

180

216

252

70

288

324 360

90

Thomas and Betts | www.manrose.com.au | [email protected]

41

Pro-Series IN-LINE MIXED FLOW FANS MIXFLO™ Fan Models Duct Size

Model No.

Switching Method

Speed Setting

Performance @ High Speed

Order Code

100mm

MF100S

Standard

2 Speed

69 l/s, 250m3/hr

FAN1004

100mm

MF100T

Timer

2 Speed

69 l/s, 250m3/hr

FAN2124

100mm

MF100PL Plug & Lead

2 Speed

69 l/s, 250m3/hr

FAN1050

125mm

MF125S

Standard

2 Speed

89 l/s, 320m3/hr

FAN1005

125mm

MF125T

Timer

2 Speed

89 l/s, 320m3/hr

FAN2125

3

125mm

MF125PL Plug & Lead

2 Speed

89 l/s, 320m /hr

FAN1051

150mm

MF150S

Standard

2 Speed

166 l/s, 597m3/hr

FAN1006

150mm

MF150T

Timer

2 Speed

166 l/s, 597m3/hr

FAN2126

3

150mm

MF150PL Plug & Lead

2 Speed

166 l/s, 597m /hr

FAN1048

200mm

MF200S

Standard

3 Speed

272 l/s, 980m3/hr

FAN1007

200mm

MF200T

Timer

2 Speed

272 l/s, 980m3/hr

FAN2127

200mm

MF200PL Plug & Lead

3 Speed

272 l/s, 980m3/hr

FAN1053

• These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. • Supported by a four year warranty or 30,000 continuous hours.

Dimension information (mm) Dimensions - MF

Models

A

B

C

D

E

F

G

MF100

98

182

315

100

100

168

27

MF125

122

182

350

100

100

168

60

MF150

147

209

360

130

115

195

55

MF200

197

244

354

142

140

230

50

Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery.

42

Mixflow 150mm Standard Model

4

YEAR WARRANTY

Technical data

technical specification 230V/50Hz/1Φ Motor Input (W)

Max Temp (ºC)

Sound Pressure Level (dBA@3m)

2300

0.40

45

40

1700

0.18

45

33

2300

0.40

45

43

1700

0.18

45

36

2700

0.70

60

47

2000

0.60

60

40

2700

0.85

60

48

2350

0.60

60

45

2000

0.45

60

41

Speed (rev/ min)

Model No.

MF100

MF125

MF150

MF200

Performance - MF100

SOUND POWER LEVEL (high speed)

125

250

500

1000

2000

4000

8000

MF100

50

56

58

58

52

47

37

MF125

52

59

60

60

56

49

41

MF150

58

66

65

63

62

54

46

MF200

65

69

64

63

62

60

48

Performance - MF125

Airflow (m3/hr) 0

50

100

Sound Power Levels LwA (dB) Octave band centre frequency in Hz

Model No.

150

Airflow (m3/hr) 200

250

300

0

50

100

150

200

250

300

350

250

200 180

200

160

Icon Key

Pressure (Pa)

Pressure (Pa)

140 120 100 80

150

Speed 1 Speed 2

100

Speed 3

60 50

40 20

0

0 0

20

40

60

0

80

20

Airflow (L/s)

Performance - MF150

100

200

60

80

100

Performance - *MF200

300

400

*MF200 Timer model only has 2 speeds, therefore Medium fan speed specifications will not apply.

Airflow (m3/hr)

Airflow (m3/hr) 0

40 Airflow (L/s)

500

600

700

350

0

200

0

50

400

600

800

1000

300

300

250

250 Pressure (Pa)

Pressure (Pa)

200 200 150 100

150

100

50

50 0 0

50

100 Airflow (L/s)

150

200

0 100

150

200

250

300

Airflow (L/s)

Thomas and Betts | www.manrose.com.au | [email protected]

43

Manrose PRO-SERIES IN-LINE WHISPERVENT FAN

Duct Size Model No.

Switching Performance Method

150mm

Standard

94 l/s, 340m3/hr

FAN0916

LB

EA

R

This high efficiency in-line fan is designed to provide higher levels of extraction with low relative noise. The ball bearing motor prolongs the life of the motor. Supported by a 5 year warranty.

BAL

• • •

Whispervent WVI150

Order Code

GM

OT O R

5

IN

YEAR WARRANTY

Manrose CLASSIC IN-LINE Hyper FAN

• • • •

89 l/s, 320m3/hr

FAN0085

This high efficiency in-line fan is designed to provide high levels of extraction. The ball bearing motor prolongs the life of the motor. Includes 1.3m lead and 3 pin plug. Supported by a 5 year warranty.

R

Standard

Hyper150

EA

150mm

Order Code

LB

Switching Performance Method

BAL

Duct Size Model No.

GM

OT O R

5

IN

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery.

44

Technical data

Dimension specification Models

A

B

C

D

WVI150

200

143

170

185

Hyper150

200

143

170

185

TECHNICAL SPECIFICATION Models

Whispervent WVI150

Hyper150

Power

220 - 240V

220 - 240V

Fan Performance

94 l/s, 340m³/hr

89 l/s, 320m³/hr

Fan Wattage

46W

38W

Maximum Pressure

160 Pa

135 Pa

Fan Speed

2750 RPM

2650 RPM

Sound Level

38 dB(A)

46 dB(A)

Max. Operating Temp

80°C

70°C

IP Rating

IPX2

IPX2

Performance - WhisperVent WVI150

36

72

108 144

180

216

Dimensions

C

A

B

D

Performance - Hyper150

252

70

288

324 360

90

36

72

108 144

180

216

252

70

288

324 360

90

Thomas and Betts | www.manrose.com.au | [email protected]

45

Manrose CLASSIC IN-LINE AXIAL FANS ID Models Duct Size

Model No.

Switching Method

Performance 3

Order Code

100mm

ID100S

Standard

23 l/s, 85m /hr

FAN0012

100mm

ID100T

Timer

23 l/s, 85m3/hr

FAN0013

125mm

ID125S

Standard

36 l/s, 130m3/hr

FAN0060

3

125mm

ID125T

Timer

36 l/s, 130m /hr

FAN0061

150mm

ID150S

Standard

87 l/s, 313m3/hr

FAN0090

150mm

ID150T

Timer

87 l/s, 313m3/hr

FAN0091

230mm

ID230S

Standard

152 l/s, 550m3/hr

FAN0405

230mm

ID230T

Timer

152 l/s, 550m3/hr

FAN0406

• • •

ID100/125/150

With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source. These axial fans have been upgraded with ball bearing motors to prolong the life of the motor. Supported by a 5 year warranty.

BAL

LB

EA

R

ID230

ECO IN-LINE AXIAL FANS

OT O R

YEAR WARRANTY

Duct Size

Model No.

Switching Method

Performance

Order Code

150mm

ECO150S

Standard

64 l/s, 230m3/hr

FAN2078

• • •

GM

5

IN

With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source. High quality sleeve bearing motor. Supported by a 2 year warranty.

2

YEAR WARRANTY

Switching Options 1. Standard Model - operates from remote switch (not supplied). 2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

46

NOTE: All fan flow rates quoted are free air delivery.

Technical data

Dimension specification Models

A

B

C

D

E

ID100

130

155

90

100

27

ID125

150

155

99

118

27

ECO150 (white)

187

153

109

150

27

ID150

187

153

109

150

27

ID230 (square model)

286

286

155

230

-

Dimensions - ID Fans

C D

A

E

B

TECHNICAL SPECIFICATION Models

ID100

ID125

ECO150

ID150

ID230

Power

220 - 240V

220 - 240V

220 - 240V

220 - 240V

220 - 240V

Fan Performance

23 l/s, 85m³/hr

36 l/s, 130m³/hr 64 l/s, 230m³/hr 87 l/s, 313m³/hr 152 l/s, 550m³/hr

Fan Wattage

20W

20W

25W

25W

80W

Maximum Pressure

20 Pa

35 Pa

50 Pa

60 Pa

50 Pa

Fan Speed

2400 RPM

2000 RPM

2400 RPM

2400 RPM

1250 RPM

Sound Level

41 dB(A)

41 dB(A)

40 dB(A)

40 dB(A)

50 dB(A)

Max. Operating Temp

50°C

50°C

50°C

50°C

50°C

IP Rating

IPX4

IPX4

IPX4

IPX4

IPX4

Performance - ID100

Performance - ID125

Performance - ID150

Performance - ID230

Performance - ECO150

Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used.

Thomas and Betts | www.manrose.com.au | [email protected]

47

Manrose CLASSIC IN-LINE CENTRIFUGAL FANS CFD Models

Duct Size Model No.

Switch Method

Performance

Order Code

100mm

CFD200S

Standard

31 l/s, 110m³/hr

FAN0326

100mm

CFD200T

Timer

31 l/s, 110m³/hr

FAN0327

125mm

CFD225S

Standard

39 l/s, 140m³/hr

FAN2067

125mm

CFD225T

Timer

39 l/s, 140m³/hr

FAN2066 Manrose Classic In-Line CF 125mm Standard

LB

EA

R

These high efficiency centrifugal fans are designed for use where longer duct runs are required. The ball bearing motor prolongs the life of the motor. Supported by a 5 year warranty.

BAL

• • •

GM

OT O R

5

IN

YEAR WARRANTY

Technical data SPECIFICATION

DIMENSION INFORMATION (mm)

Models

CFD200

CFD225

Models

A

B

C

D

E

Power

220 - 240V

220 - 240V

CFD200

155

100

100

195

258

Fan Performance

31 l/s, 110m³/hr

39 l/s, 140m³/hr

CFD225

155

125

125

195

258

Fan Wattage

20W

20W

Maximum Pressure

120Pa

120Pa

Fan Speed

1400 RPM

1400 RPM

Sound Level

45 dB(A)

45 dB(A)

Max. Operating Temp

50°C

50°C

IP Rating

IPX4

IPX4

Performance - CFD200

Performance - CFD225

Dimensions - CFD200/CFD225

B

C

A

E

Switching Options 1. Standard Model - operates from remote switch (not supplied).

3. Requires: permanent phase and switched phase.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes.

NOTE: All fan flow rates quoted are free air delivery.

48

D

SIMX in-line CENTRIFUGAL 3 SPEED FANS High Performance Models Duct Size

Model No. Performance @ Speed 3

Order Code

150mm

3 Speed

115 l/s, 415m³/hr

FAN0921

200mm

3 Speed

208 l/s, 750m³/hr

FAN0997

• Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide high performance at your preset choice of speed. • Supported by a 2 year warranty. Please note: Can be used for supply or extract.

2

TECHNICAL DATA

DIMENSION INFORMATION (mm)

YEAR WARRANTY

Dimensions

Models

A

B

C

D

E

150mm

340

150

154

50

75

200mm

340

200

280

50

50

TECHNICAL SPECIFICATION Models

150mm

200mm

Voltage/Freq (50hz)

220 - 240V

220 - 240V

Fan Performance Speed 1

65 l/s, 234m³/hr

125 l/s, 450m³/hr

Fan Performance Speed 2

90 l/s, 324m³/hr

170 l/s, 620m³/hr

Fan Performance Speed 3

124 l/s, 425m³/hr

205 l/s, 740m³/hr

Fan Wattage (at high speed)

65W

110W

Current (A) (at high speed)

0.36

0.38

Fan Speed (at high speed)

2460 RPM

2700 RPM

Sound Level*

43 dB(A)

56 dB(A)

Ambient Temp

50°C

60°C

* dB(A) - measured 1m free field. Performance - 200mm 3 Speed Performance - 150mm 3 Speed

200mm 3 Speed Centrifugal Fan Curve 400

Pressure (Pa)

300

200

100

100

200

300

400

500

600

700

800

900

1000

Airflow (m3/hr)

Thomas and Betts | www.manrose.com.au | [email protected]

100

200

300

400

500

600

700

800

900

1000 Volume (m3/hr)

49

SIMX IN-LINE FANS

High Performance Centrifugal Models Duct Size

Model No

Performance

Order Code

100mm

MAN100

49 l/s, 176m3/hr

FAN0361

125mm

3

61 l/s, 220m /hr

MAN125

FAN0360

3

150mm

MAN150

115 l/s, 415m /hr

FAN0330

200mm

MAN200

208 l/s, 750m3/hr

FAN0467

250mm 315mm

3

FAN0358

3

FAN0357

280 l/s, 1010m /hr

MAN250

360 l/s, 1300m /hr

MAN315

• Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide extremely high performance with a choice of sizes. • Supported by a 2 year warranty. Please note: Can be used for supply/extract.

Models

A

B

C

D

E

MAN100

250

100

136

50

70

MAN125

250

125

147

60

60

MAN150

340

150

154

50

75

MAN200

340

200

250

50

50

MAN250

320

249

310

65

65

MAN315

405

315

177

80

80

50

2

YEAR WARRANTY

DIMENSION INFORMATION (mm)

Dimensions

Simx 150mm In-Line Fan

TECHNICAL DATA Technical INFORMATION Models

MAN100

MAN125

MAN150

MAN200

MAN250

MAN315

Voltage/Freq (50hz)

220-240V

220-240V

220-240V

220-240V

220-240V

220-240V

Fan Performance

49 l/s, 176m³/hr

61 l/s, 220m³/hr

115 l/s, 415m³/hr

208 l/s, 750m³/hr

280 l/s, 1010m³/hr

360 l/s, 1300m³/hr

Fan Wattage

32W

31W

65W

110W

170W

200W

Maximum Pressure

153 Pa

143 Pa

320 Pa

418 Pa

500 Pa

590 Pa

Current (A)

0.14

0.13

0.35

0.45

0.76

0.87

Fan Speed (min -1)

2500 RPM

2490 RPM

2350 RPM

2520 RPM

2580 RPM

2410 RPM

Sound Level*

38 dB(A)

38 dB(A)

50 dB(A)

56 dB(A)

47 dB(A)

57 dB(A)

Max Operating Temp

60°C

60°C

50°C

60°C

50°C

45°C

* dB(A) - measured 1m free field.

Performance - MAN125

Performance - MAN100 Volume (m³/h) 0

20

40

Volume (m³/h) 60

0

80 100 120 140 160 180

100mm

100

150

200

250

0

100

100

80

80

60

60

Static Pressure (Pa)

120

40 20 0 0

10

20

30

125mm

140

120

40

0

10

20

30

Volume (m³/h) 0

450

40

50

60

200

400

400

300

350

250

300

800

0

150

200

250

20

40

Volume (m³/h) 0 200 400

1000

60

80

100

120

600

800

1000

1200

1400

600 315mm

250mm

500 400 300

200

Static Pressure (Pa)

Static Pressure (Pa) Volume l/s

50

0

250

200

100

150mm

Performance - MAN315

600

450

200mm

350

50

400

100

70

500

0

350

Volume l/s

0 100 200 300 400 500 600 700 800 900

0

300

0

Volume (m³/h)

50

250

150

Performance - MAN250

100

200

200

20

50

150

150

250

Volume l/s

400

100

300

40

Volume l/s

Performance - MAN200

50

350

Static Pressure (Pa)

140

Static Pressure (Pa)

Volume (m³/h)

50

160

160

Static Pressure (Pa)

Performance - MAN150

150 100 50 0 0

50

Volume l/s

100

150

200

250

300

200 100 0 0

50

100

150

200

250

300

350

400

Volume l/s

Thomas and Betts | www.manrose.com.au | [email protected]

51

SIMX IN-LINE CENTRIFUGAL FANS WhisperVent Low Profile Models Duct Size

Model No

Performance

Order Code

150mm

WVILP150-1

124 l/s, 445m3/hr

FAN0829

150mm

WVILP150-3

118 l/s, 425m3/hr

FAN0830

• •

Suitable for a variety of domestic and commercial applications, this in-line centrifugal fan offers high performance with a low profile design to enable this unit to be installed in confined spaces. Supported by a 2 year warranty.

2

DIMENSION INFORMATION (mm)

YEAR WARRANTY

Models

A

B

C

D

E

WhisperVent Low Profile

313

168

148

340

218

Dimensions

A

D

E

B

52

ØC

TECHNICAL DATA

Technical specification

Models

Fan Speed

FAN0830

1

65 l/s, 234m³/hr

FAN0830

2

FAN0830 FAN0829

Fan Performance

Norm Fan Speed (RPM)

Single Phase Nom Watts

Nom Amps

1440

50

0.22

90 l/s, 324m³/hr

1860

56

0.24

3

124 l/s, 445m³/hr

2460

80

0.36

1

118 l/s, 425m³/hr

2520

80

0.36

SOUND POWER LEVEL

Model No

Sound Power Levels Lw (A) Octave band centre frequency in Hz

dB(A) @ 3m

63

125

250

500

1k

2k

4k

8k

FAN0830 - Speed 1

-

20

34

43

43

44

40

30

30

FAN0830 - Speed 2

-

26

40

51

51

52

45

38

36

FAN0830 - Speed 3

-

40

42

62

64

64

59

45

43

57

61

68

67

65

64

59

53

43

FAN0829

Performance - FAN0829 & FAN0830

Thomas and Betts | www.manrose.com.au | [email protected]

53

SIMX EXTERNAL WALL MOUNTED Fans Extract MODELS Duct Size

Fan Type

Air

Performance

Order Code

150mm

Axial

Extract*

73 l/s, 263m3/hr

FAN2303

150mm

Ctr’fgl (190 Motor)

Extract

109 l/s, 392m3/hr

FAN2425

150mm

Ctr’fgl (220 Motor)

Extract

133 l/s, 480m3/hr

FAN2424

*Also available in a Supply Air option

• • •

Designed for use in residential and light commercial applications where a high performance, low noise solution is required. Specific applications include apartments where space is limited. Supported by a 2 year warranty.

150mm Ctr’fgl (190 Motor)

SIMX EXTERNAL WALL Mounted Fans 3 Speed Extract MODELS Duct Size

Fan Type

Air

Performance (High Speed)

Order Code

150mm

Ctr’fgl (190 Motor)

Extract

113 l/s, 408m3/hr

FAN2423

150mm

Ctr’fgl (220 Motor)

Extract

136 l/s, 493m3/hr

FAN2426

• • • •

Designed for use in residential and light commercial applications where a high performance, low noise solution is required. Three speed models enable further flexibility in a variety of applications. Specific applications include apartments where space is limited. Supported by a 2 year warranty.

Wall mounted with measurements

369mm 369mm

305mm 110mm 110mm

305mm

Switching Options 1. Electrical connection must be made internally (Junction Box is only suitable for internal use). NOTE: All fan flow rates quoted are free air delivery.

54

Fan Assembly - Line Drawing

2

YEAR WARRANTY

TECHNICAL DATA PERFORMANCE DATA

Order Code

Motor Size Description (mm)

FAN2303

150

FAN2425

Fan Performance m³/hr

l/s

Watts @ 230V

Axial

263

73

48

0.29

80

48

150

Centrifugal 190 Motor (1 Speed)

392

109

65

0.28

280

60

FAN2424

150

Centrifugal 220 Motor (1 Speed)

480

133

96

0.42

380

61

FAN2423

150

Centrifugal 190 Motor (3 Speed) High Speed

408

113

65

0.28

280

60

Medium Speed

340

94

57

0.25

250

56

Low Speed

277

77

55

0.24

200

46

High Speed

493

136

96

0.42

380

61

Medium Speed

408

113

69

0.34

340

56

Low Speed

340

94

60

0.31

280

50

FAN2426

Amps

Static Sound Level Pressure (Pa) (dB(A) @ 3m)

Centrifugal 220 Motor (3 Speed)

150

400 350

Icon Key

300

Pressure (Pa)

250 200

FAN2303 150mm AXIAL

150

FAN2425 150mm CENTRIFUGAL (190 Motor)

100 50

FAN2424 150mm CENTRIFUGAL (220 Motor)

0 0

50

100

150

Airflow (L/s)

400 350 300

Pressure (Pa)

250 200 150

FAN2423 150mm 3 SPEED CENTRIFUGAL (190 Motor)

100 50

FAN2426 150mm 3 SPEED CENTRIFUGAL (220 Motor)

0 0

50

100

150

Airflow (L/s)

Thomas and Betts | www.manrose.com.au | [email protected]

55

THRU-ROOF MOUNTED FANS Thru Roof Fan Cowl Models Duct Size 150mm 150mm 150mm

Fan Type Ctr’fgl Ctr’fgl 3-spd Axial - Whisper

Air Extract Extract Extract

Performance

Order Code

3

FAN0529

3

FAN1002

153 l/s, 550m hr 153 l/s, 550m hr 3

FAN1009

3

89 l/s, 320m /hr

150mm

Axial

Extract

75 l/s, 270m /hr

FAN0531

150mm

Axial - Whisper

Supply

75 l/s, 270m3/hr

FAN0533

150mm Axial - Whisper

• High quality aluminium cowl construction, with fan incorporated, for longevity of operation. • Supported by a 2 year warranty.

With Flashing & HDPE Tube Duct Size

Fan Type

Air

Performance

Order Code

150mm

Ctr’fgl

Extract

153 l/s, 550m3hr

FAN0530

3

150mm

Ctr’fgl 3-spd

Extract

153 l/s, 550m hr

FAN0967

150mm

Axial - Whisper

Extract

89 l/s, 320m3/hr

FAN1060

3

150mm

Axial

Extract

75 l/s, 270m /hr

FAN0532

150mm

Axial

Supply

75 l/s, 270m3/hr

FAN0534

150mm 150mm

H/D Axial H/D Ctr’fgl

Extract Extract

3

75 l/s, 270m /hr 3

153 l/s, 550m hr

FAN0739 FAN0740

150mm Axial - Whisper

2

YEAR WARRANTY

H/D = Heavy Duty cowl used in these kits.

• • •

High quality aluminium cowl construction, with fan incorporated for longevity of operation. Includes Flashing for metal based roofs, an optional lead Flashing is available for concrete tile roofs (DCT0190) at an additional cost. Supported by a 2 year warranty.

Thru Roof Fan System Models Duct Size

Description

Fan Type

Performance*

Order Code

150mm

Ultra

Ctr’fgl

153 l/s, 550m3/hr

FAN0535

150mm • • •

Hyper

Hyper

3

75 l/s, 270m /hr

DCT0189

High quality aluminium cowl construction, with fan incorporated, for longevity of operation. Includes Flashing for metal based roofs, an optional lead Flashing is available for concrete tile roofs (DCT0190) at an additional cost. Supported by a 2 year warranty. 150mm Hyper Fan System

Connection 1. Electrical connection can be made inside or outside the roof space. * NOTE: All fan flow rates quoted are motor performance in free air.

2

YEAR WARRANTY

56

TECHNICAL DATA

Dimension information (mm) Dimensions - Thru Roof Fans

Models

A

B

C

FAN0529 - FAN1002

275

170

-

FAN1009

275

170

-

FAN0531- FAN0533

275

170

-

FAN0530 - FAN0967

275

170

500

FAN1060

275

170

500

FAN0532 - FAN0534

275

170

500

FAN0739 - FAN0740

275

170

500

A B

C

TECHNICAL SPECIFICATION Models

FAN0529 FAN0530 FAN0740

FAN1002 FAN0967

FAN0531 FAN0532 FAN0739

FAN0533 FAN0534

FAN1009 FAN1060

Supply Voltage

220-240VAC

220-240VAC

220-240VAC

220-240VAC

220-240VAC

Fan

Centrifugal

Axial

Axial

Axial - Whisper

Centrifugal 3

3

Fan Performance

153 l/s, 550m /hr

153 l/s, 550m /hr

75 l/s, 270m /hr

75 l/s, 270m /hr

89 l/s, 320m3/hr

Fan Wattage

58W

58W

44W

44W

46W

Maximum Pressure

320 Pa

320 Pa

80 Pa

130 Pa

130 Pa

Fan Speed

2500 RPM

2500 RPM

2850 RPM

2850 RPM

2750 RPM

Sound Level @ 1m

62 dB(A)

62 dB(A)

55 dB(A)

55 dB(A)

38 dB(A)

Operating Temp

-25 - +50°C

-25 - +50°C

-20 - +80°C

-20 - +80°C

-20 - +80°C

IP Rating

IPX4

IPX4

IPX2

IPX2

IPX2

Performance - FAN0529/FAN0530/FAN0740

3

3

Performance - FAN0531/FAN0532/FAN0739

90

350

80

300

70 60 Pressure (Pa)

Pressure (Pa)

250 200 150

50 40 30

100

20 50

10

0 0

50

100

150

0

200

0

20

40

Airflow (L/s)

FAN0530 / FAN0555- FAN0533/FAN0534 Performance

80

100

120

Performance - FAN1009/FAN1060

FAN0532 / FAN0553

90

160

80

140

70

120

Pressure (Pa)

60 Pressure (Pa)

60 Airflow (L/s)

50 40 30

100 80 60 40

20

20

10 0 0

20

40

60

80

100

120

0 0

Airflow (L/s)

FAN0532 / FAN0553

50

100

150

Airflow (L/s)

FAN1009 / FAN1060

Thomas and Betts | www.manrose.com.au | [email protected]

57

Manrose PRO-SERIES HAND DRYERS PUBLIC AREAS/HEAVY USAGE APPLICATIONS

NEW

Designed to provide a cost effective alternative to conventional Hand Dryers. Providing a rapid drying time of 10 seconds, almost half that of the competitors products, thus reducing washroom time.

Switching Performance Method

Model No.

Cover

MAN/E-88AE

Stainless White Steel

Auto

56 l/s, 200m3/hr

FAN2287

MAN/E-88AEBC

Stainless Satin Steel

Auto

56 l/s, 200m3/hr

FAN2286

• • • •

Colour

Order Code

Heavy Usage Hand Dryers

70% energy savings. Tamper Proof Technology. Suitable for use in public areas for heavy usage. Supported by a 5 year warranty. Manrose Hand Dryer - MAN/E-88AE

Manrose CLASSIC HAND DRYERS PUBLIC AREAS/HEAVY USAGE APPLICATIONS

Model No.

Cover

Colour

Switching Performance Method

MAN/M-88A

ABS Thermoplastic

White

Auto

56 l/s, 200m3/hr

FAN2902

MAN/A-89

3mm Aluminium

White

Auto

108 l/s, 388m3/hr

FAN4396

MAN/A-89S

3mm Aluminium

Silver

Auto

108 l/s, 388m3/hr

FAN4395

MAN/A-89B

3mm Aluminium

Black

Auto

108 l/s, 388m3/hr

FAN4397

MAN/E-88A

Porcelain Enamel 2mm Steel

White

Auto

130 l/s, 470m3/hr

FAN2903

• •

Order Code

These models are suitable for use in public areas such as lavatories, factories, schools, railways and motorway service stations and are designed for heavy usage and unsupervised areas. Supported by a 2 year warranty.

Manrose Hand Dryer - MAN/E-88AEBC

Manrose MAN/M-88A

Manrose MAN/A-89

Colour Options available: White, Silver and Black

Manrose MAN/E-88A

2

YEAR WARRANTY

58

TECHNICAL DATA Dimension information

Dimension SPECIFICATION (mm) - Hand dryers Model

A

B

C

MAN/E-88AE

201

277

175

MAN/E-88AEBC

201

277

175

MAN/M-88A

225

275

160

MAN/A-89

225

275

160

MAN/E-88A

284

248

202

TECHNICAL SPECIFICATION - Pro-Series Dimensions - MAN/E-88AE Models, MAN/E-88AEBC

Models

MAN/E-88AE

MAN/E-88AEBC

Power

220 - 240V

220 - 240V

Cover

Stainless Steel

Stainless Steel

Colour

White

Stainless Satin Steel 3

Fan Performance

56 l/s, 200m /hr

56 l/s, 200m3/hr

Operation

No touch infra-red detection

No touch infra-red detection

Heater Element

450 - 900W adjustable

450 - 900W adjustable

Power

1.6kW @ 240V

1.6kW @ 240V

Dry Time

10 secs

10 secs

Sound Level

74 dB(A)

74 dB(A)

Weight

7.0kg

7.0kg

A

B

C

Dimensions - MAN/M-88A, A-89, A-89S A-89B

A

TECHNICAL SPECIFICATION - CLASSIC B

Models

MAN/M-88A

MAN/A-89

MAN/E-88A

Power

220 - 240V

220 - 240V

220 - 240V

C Depth

Cover Colour

ABS Thermoplastic 3mm Aluminium White

Fan Performance 56 l/s, 200m³/hr

Steel 2mm Porcelain Enamel

White, Silver, Black

White

108 l/s, 388m3/hr

130 l/s, 470m³/hr

Operation

No touch infra-red detection

No touch infra-red detection

No touch infra-red detection

Power

1.5kW @ 240V

2.0kW @ 240V

2.4kW @ 240V

Sound Level

54 dB(A)

69 dB(A)

70 dB(A)

Weight

3.3kg

4.7kg

7.5kg

Dimensions - MAN/E-88A

A

Thomas and Betts | www.manrose.com.au | [email protected]

B

Depth

C

59

SPECIALISED FANS Frame Fan Model Duct Size

Model No.

Switching Method

Performance

120mm

Frame Fan

Standard

38 l/s, 138m³/hr FAN0397

150mm

Frame Fan

Standard

89 l/s, 320m³/hr FAN1043

• • •

Order Code

This frame fan is designed for use in computer rooms or applications where the introduction of cool air is required for small enclosed spaces. The ball bearing motor prolongs the life of the motor. Supported by a 2 year warranty.

Frame Fan 125mm

ACCESSORIES Duct Size

Description

Order Code

120mm

Finger Guard for FAN0397 - Metal

FAN0412

120mm

Filter Guard for FAN0397

FAN0413

150mm

Finger Guard for FAN1043

FAN0841

TECHNICAL DATA

2

Technical information

YEAR WARRANTY

Models

Frame Fan 125

Frame Fan 150

Power

220 - 240V

220 - 240V

Fan Performance

38 l/s, 138m³/hr

89 l/s, 320m³/hr

Fan Wattage

15W

38W

Models

A

B

C

Maximum Pressure

62Pa

135Pa

Frame Fan 125

120

120

105 40

Fan Speed

2650 RPM

2650 RPM

Frame Fan 150

172

150

160 51

Sound Level

43 dB(A)

46 dB(A)

Max. Operating Temp

80°C

70°C

IP Rating

IPX4

IPX2

Performance - 125mm Frame Fan

Dimension SPECIFICATION

Performance - 150mm Frame Fan

Dimensions - Frame Fan

D 36

72

108 144

180

216

252

288

D

324 360

A C

B

70

NOTE: All fan flow rates quoted are free air delivery.

60

90

Manrose CLASSIC DC SPECIALISED FANS 12/24V Extract-a-lite Models Duct Size

Model No.

Switching Colour Method

Performance

Order Code

100mm

BSL112W

Standard

18 l/s, 64m3/hr

FAN0625

White

3

100mm

BSL112G

Standard

Gold

18 l/s, 64m /hr

FAN0690

100mm

BSL112C

Standard

Chrome

18 l/s, 64m3/hr

FAN0691

3

100mm

BSL124W

Standard

White

18 l/s, 64m /hr

FAN0626

100mm

BSL124G

Standard

Gold

18 l/s, 64m3/hr

FAN0686

100mm • • • •

BSL124C

Standard

3

Chrome

18 l/s, 64m /hr

FAN0685

A compact extractor fan combined with an integral halogen light. Designed for installation in galleys, showers and toilets, ideal for marine and other leisure applications. Long life computer motor which will run continuously, only 2.8 watts. Supported by a 2 year warranty. Dimensions - DC Extract-a-lite

ACCESSORIES - Extract-a-lite Cowl

C

Duct Size

Description

Order Code

100mm

Extract-a-lite cowl

DCT1097

E B

A

• External cowl suitable for use in marine and non-marine applications

TECHNICAL DATA

F

D

Dimension information Models

A

B

C

D

E

F

BSL112

140

90

52

12

98

38

BSL124

140

90

52

10

98

38

A

TECHNICAL SPECIFICATION

Performance - DC Extract-a-lite

Models

BSL112

BSL124

Power

12 VDC

24 VDC

Fan Performance

18 l/s, 64m³/hr

18 l/s, 64m³/hr

Fan Wattage

45W

45W

Maximum Pressure

125 Pa

125 Pa

Fan Speed

1400 RPM

1400 RPM

Sound Level

45 dB(A)

45 dB(A)

Max. Operating Temp

40°C

40°C

IP Rating

IPX4

IPX4

2

YEAR WARRANTY

Switching options 1. Standard Model - operates from remote switch (not supplied). NOTE: All fan flow rates quoted are free air delivery.

61

FAN ACCESSORIES Fan timer Model No.

Description

Order Code

Time Air

7 Minute Fixed Timer (suits fans 20W-200W)

FAN0372

• A fixed fan timer that will automatically switch the appliance off after approximately 7 minutes. Description

Order Code

Fully Adjustable Run-On Fan Timer

FAN2444

Time Air - Fan Timer

• Timing Switch 1 Sec to 90 Mins. • Adjustable Run Timer & Start Delay.

Transformers

Fully adjustable Run-On Fan Timer

Model No.

Description

Order Code

ACTO TE0060

Electronic Transformer 12VAC 50kHz

FAN2101

• • • • •

This transformer must only be used with 12V lighting installations. Supports lamp wattages from 20W - 60W. Overload & short circuit protection with self resetting. Over temperature cut off. Dimmable with trailing and leading edge dimmers.

Model No.

Description

Order Code

TM 50-2-07

SELV Isolating Transformer 12VAC

FAN2402

• • • • • • • •

Electronic Transformer

SELV isolating transformer is required for all low voltage fan installations. Can be used with low voltage 12V lighting. Supports lamp wattages from 20W - 50W. An iron core transformer. Thermally stable and shatter-proof plastic casings. Overload & short circuit protection with self resetting. Over temperature cut off. Dimmable with trailing and leading edge dimmers.

Humidistat Controller Model No.

Description

Order Code

1360

Humidistat Controller

FAN0963

• • • 62

Designed to operate the fan when the relative humidity (RH) reaches a preset level. Fits a double pattress. This unit is adjustable between 20 - 90% RH.

Humidistat Controller

FAN ACCESSORIES ULTECON Thermostats Model No.

Description

Order Code

TA01

Analogue Thermostat

FAN0153

TD01

Digital Thermostat

FAN0981

TD02

Digital 2 Speed Thermostat

FAN0982

TD03

Digital 3 Speed Thermostat

FAN0983

• • • •

High quality, easy to use thermostats. Dual output switching for both cooling and heating situations. Electronic temperature sensor. Included in Heat Trans systems.

TD03 Digital 3 Speed Thermostat

Speed Controllers Model No.

Description

Switching Method

Order Code

1348

For XF/XP/WF 230/300 Fans*

2 Spd + Reverse

FAN0155

1349

For XF/XP/WF 230/300 Fans*

Adjust + Reverse

FAN0156

1350

For any XF/XP/WF 230/300 Fans

Adjustable

FAN0157

PDL625F

General Purpose up to 500W

On-Off + Adjust

FAN2104

• A range of speed controllers with variable or 2 speed and reversible options. • Models 1348-1350: Electrical load must be between 20 and 200 watts. • FAN0154 - Single pattress mounting block for FAN0155/0156/0157.

PDL625F General Purpose

*Not suitable for manual pull cord model fans.

ULTECON Speed Controller Model No.

Description

Input Output Current Power

Order Code

SPC05

Ultecon 5 Speed Fan Controller

1A

FAN1096

100W

• 5 speed fan selection - manual or external control. • Enclosure can be wall mounted or free standing. • On/Off switch.

Ulecon 5 Speed Fan Controller

Fan Mounting Brackets Duct Size

Description

Order Code

100-200mm

Fan Mounting Bracket for 100 - 200mm

FAN0015

250-315mm

Fan Mounting Bracket for 250 - 315mm

FAN0016

• These adjustable fan mounting brackets, designed for use with the centrifugal fans. • Supplied in pairs.

100-200mm Fan Mounting Bracket

Thomas and Betts | www.manrose.com.au | [email protected]

63

AUSTRALIAN DUCT STANDARDS

system then YOU ARE IN BREACH OF AS 4254, not the manufacturer/duct assemblers.

We strive to provide the best possible flexible duct at a competitive and fair price, that complies to all necessary Standards.

Ducting that does not comply to AS 4254 may be used on Reverse Cycle and Evaporative Systems except in Victoria. The onus is on you to choose and use compliant product.

Australian Standards (AS) 4254 & (AS) 4508 Most Commonly Asked Questions: Q. What is AS 4254?

Q. What is AS 4508?

A. Australian Duct Fire Standard (AS) 4254. This standard was developed to ensure public safety, that the product tested will not support combustion and will function as designed for its service life. All heating systems in Australia ignited from a flame source and all commercial class 2 to 9 buildings must FULLY COMPLY with AS 4254. In Victoria all Ducting Installations must be fire rated to AS 4254. Q. How do I know if the duct passes AS 4254? A. If a flexible duct passes AS 4254 it has been tested to and passed eleven difficult tests. Ensure the product in the test has been tested in its composite form, just the way you buy it, i.e. duct core, insulation blanket and outer jacket. Each test should state product name and its componentry make-up. If you cannot be supplied test reports to cover each of the eleven tests or there is a reluctance from duct manufacturers/duct assemblers to produce any or all of these reports it is likely that the duct DOES NOT comply to AS 4254. Manufacturers/duct assemblers are under no obligation to produce AS 4254 compliant product. If you install flexible duct that does not comply, on a gas fired heating

A. Australian insulation Standard (AS) 4508. Due to poor quality insulation being used on ducting, AS 4508 was developed to create minimum acceptable thermal values for ducting, helping to reduce the greenhouse effect and lower running costs. This standard specifies how insulation on the ducting must be tested so an overall thermal or “R” value can be achieved consistently throughout all the duct in the system. Q. How do I know if the insulation meets the requirements of AS 4508? A. Ask to see the test report from your duct manufacturer /duct assembler that shows that the insulation had been tested to and complies with AS 4508. To achieve a thermal rating of R0.6 you must use a minimum of 250 g/ m² polyfibre insulation at 40mm thick. To achieve an R1.0 you must use a minimum of 450 gram/square metre polyfibre insulation at 70mm thick. Fibreglass thermal values remain the same as they have for years, 25mm=R0.6 and 40mm=R1.0. There will be variations depending on the manufacturer of the insulation but in general the above rules apply.

Compliance to AS/NZ 1530 Part 3

AS/NZS 1530 Part 3

Requirements are:

This is the Australian standard 1530, method for fire tests on building materials components and structures.

Internal Surface:

Spread of flame not >0 Smoke Developed not >3

External Surface:

Spread of flame not >7 Smoke developed not >5

“Simultaneous determination of ignitability, flame propagation, heat release and smoke release”

AS 4254 comprises of the tests listed below: (AS) 1530 part 3 - radiant burn test Underwriters Laboratories

64

(U.L) 181 part 9 - flaming burn test

(U.L) 181 part 14 - static load test

(U.L) 181 part 11 - mould growth test

(U.L) 181 part 15 - impact test

(U.L) 181 part 12.2 - low temperature test

(U.L) 181 part 17 - positive & negative pressure test

(U.L) 181 part 12.3 - high temperature test

(U.L) 181 part 18 - collapse test

(U.L) 181 part 13 - puncture test

(U.L) 181 part 19 - tension test

DUCTING INSTALLATION & USAGE The layout of flexible duct, the number of bends, the sharpness of the bend and the amount of sag allowed between support joints will have serious effects on system performance due to the increased resistance to airflow each introduces. Use the minimum length of flexible duct to make connections. It is not recommended that excess length of ducts be installed to allow for possible future relocations of air terminal devices. Avoid installation where exposure to direct sunlight can occur e.g: skylight. Grilles and diffusers need to be supported independently of the flexible duct. Repair torn or damaged vapour barrier/jacket with duct tape listed and labelled to Standard AS4254. If internal core is penetrated, replace flexible duct or treat as a join.

Right Setup

Install duct fully extended, do not install in the compressed state or use excess lengths. This will noticeably increase friction losses.

Wrong Setup

Avoid bending ducts across sharp corners or incidental contact with metal fixtures, pipes or conduits. Flexible ducts shall be installed with a bend radius to duct diameter ratio in accordance with the following info on the next page.

65

DUCTING INSTALLATION & USAGE Duct velocity R/D ratio centerline radius to duct diameter:

Up to 5m/s x 0.6 5m/s x 1.0 Above 8m/s x 1.5

e.g. Assuming duct velocity of 8m/s

Steam Pipes

Wrong Setup

Do not install near hot equipment (e.g. heaters boilers, steam pipes etc.) that is above the recommended flexible duct use temperature.

66

AIR DUCTS 01

Non-metallic with Plain Ends. After desired length is determined, cut completely around and through duct with knife or scissors. Cut wire with wire cutters. Fold back duct jacket and insulation.

02

Slide at least 1” (25mm) of core over the fitting up to the bead. Seal the core to collar with at least two wraps of duct tape. Secure connection with cable ties placed over the core and duct tape.

03

Pull jacket and insulation back over core. Tape jacket with at least 2 wraps of duct tape ensuring end of the outer jacket is secured to the spigot. Cable ties may be used in place of or in combination with the duct tape.

67

JOINS 01

Fold back duct jacket and insulation from core. Butt two cores together on a 4” (100mm) length metal sleeve or polymer sleeve.

02

03

Tape cores together with at least 2 wraps of duct tape. Connection can be secured with 2 cable ties placed over the taped core ends.

Pull jacket and insulation back over cores. Tape jackets together with at least 2 wraps of duct tape.

68

SUPPORTING FLEXIBLE DUCT 01

Flexible duct shall be supported at intervals, no greater distance than 1.5m. Maximum permissible sag is 60mm per metre of spacing between supports. A connection to rigid duct or equipment shall be considered a support joint. SAG 60mm

Long horizontal duct runs with sharp bends shall have additional supports before and after the bend approximately one duct diameter from the centreline of the bend. Recommend Hanging Straps DCT0808.

02

Hanger or saddle material in contact with the flexible duct shall be of sufficient width to prevent any restriction of the internal diameter of the duct when the weight of the supported section rests on the hanger or saddle material. In no case will the material contacting the flexible duct be less than 40mm wide. 40mm min

40mm

Wire

03

Factory installed suspension systems integral to the flexible duct is an acceptable hanging method.

69

SUPPORTING FLEXIBLE DUCT

Flexible ducts may rest on ceiling joists or truss supports. Maximum spacing between supports shall not exceed 1.5m.

Ceiling Joist

(1.8m) Max

Vertically installed duct shall be stabilised by support straps at a max of 1.8m.

Support the duct between a metal connection and bend by allowing the duct to extend straight for 100mm before making the bend. This will avoid possible damage of the flexible duct by the edge of the metal collar. NOTE: Upon completion of installation, please test in accordance with 2.8.2 of standard AS4254. NOTE: factory-made air ducts may not be used for vertical risers in air duct systems serving more than two stories.

70

FLEXIBLE DUCTING Flexible Ducting Friction FRICTION LOSS GRAPH Loss Graph

Technical Data Flexible Ducting Friction Loss Graph

Technical Data

3/h 3/h Air Volume mm AirVolume

Air Volume m3/h (m3/h 3.6 = l/s) 3/h / 3.6 = l/s) 3/h (m(m / 3.6 = l/s)

(m3/h / 3.6 = l/s)

Air Volume m3/h

Diameter of Duct in mm

Flexible Ducting Friction Loss Graph

Friction Loss (Pa per metre)

40

40

metre) Loss (Pa Friction FrictionLoss (Paperper metre)

0

Technical Data

Friction Loss (Paper metre)

Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz

Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz

Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz

71

ALUDUCT/COMFLEX FLEXIBLE DUCTING

Diameter (mm)

Length (m)

MANROSE ALUDUCT

COMFLEX NUDE

COMFLEX INSULATED

Order Code

Order Code

Order Code

100

1 3 6

DCT0357 DCT0328

125

1 3 6

DCT0358 DCT0329

150

1 3 6

DCT0359 DCT0330

200

3 6

250

3 6

DCT0367 DCT0409

Nude

DCT0368 DCT0410 DCT0369 DCT0411

DCT0088 DCT0399

DCT0331

DCT0377 DCT0412

DCT0089 DCT0343

DCT0332

DCT0370 DCT0413

DCT0400 DCT0344

300

3 6

DCT0380 DCT0414

DCT0401 DCT0402

350

3 6

DCT0415 DCT0416

DCT0403 DCT0404

400

3 6

DCT0417 DCT0418

DCT0405 DCT0406

• • • • • •

Insulated

Fully complies to AS 1530 Pt3. DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto a corrosion resistant coated, spring steel wire helix. DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised. DUCT INSULATION: AS4508 Polyester R0.6. TEMPERATURE RANGE: Maximum: +80˚C, Minimum: -10˚C. COLOUR: Silver with black sleeve.

Colour Code Label Guide: Ducting

Black 150mm (6”)

Blue 250mm (10”)

Red 350mm (14”)

Yellow 200mm (8”)

White 300mm (12”)

Grey 400mm (16”)

Note All 1 metre lengths are packed in bags with header cards, 3 metre aluduct duct is supplied boxed and all other items are supplied in colour coded bags. No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure. Products with the “order code” shown are generally ex. stock lines - other products are available to order.

72

Should you have an ongoing requirement for an item that is not a standard stock line - PLEASE discuss with us and we will review stocking the item for you.

UNILOK

FR1 Acoustic Ducting INSULATED R0.6

INSULATED R1.0

Order Code

Order Code

Diameter (mm)

Length (m)

100

3 6

DCT1216

DCT1268

125

3 6

DCT1164 DCT1224

DCT1176

150

3 6

DCT0633 DCT0634

DCT0833 DCT0834

200

3 6

DCT0635 DCT0636

DCT0835 DCT0836

Acoustic Insulated R0.6 (40mm)

UNILOK FR1 Acoustic Ducting is a flexible duct manufactured “tough” & “whisper quiet” for consumer & installer peace of mind. Unlike other types of flexible duct, UNILOK FR1 has an outer steel rib that ensures the products integrity, and correct diameter, even in the tightest bends. Due to its steel rib, it is not prone to glue failure or fatigue (sagging or ovalisation) from vibration with age like plastic ribbed or non-ribbed glued duct.

• • • • • • • •

Fully complies to AS1530 Pt3. Designed for low noise air transfer. Fully flexible same mechanical construction as standard Unilok ducting. DUCT CORE: A UV resilient fire retardant 100μm black low density polyethylene perforated material mechanically locked into an outer metal helix with a copper coated spring steel wire. DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised. DUCT INSULATION R0.6: AS4508 Polyester R0.6. DUCT INSULATION R1.0: AS4508 Polyester R1.0. TEMPERATURE RANGE: Maximum: +80˚C, Minimum: -10˚C.

Insertion Loss, dB Octive Band Centre Frequency Sample

125

250

500

1000

2000

4000

8000

150mm UNILOK FR1 R0.6 AI

35.5

39.2

36.0

30.3

29.8

31.5

22.5

300mm UNILOK FR1 R0.6 AI

33.3

35.9

27.3

31.0

28.1

17.0

12.2

400mm UNILOK FR1 R0.6 AI

36.1

30.0

20.6

27.2

26.0

12.7

10.5

Colour Code Label Guide: Ducting

Black 150mm (6”)

Yellow 200mm (8”)

Note 1. Products with the “order code” shown are generally ex. stock lines - other products are available to order

2. Should you have an ongoing requirement for an item that is not a standard stock line – PLEASE discuss with us and we will review stocking the item for you.

73

Manrose PVC Flexible Ducting Diameter (mm)

Length (m)

Pack

Order Code

100

1 3

Header Carded Boxed

DCT0936 DCT0336

125

1 4

Header Carded Boxed

DCT0937 DCT0337

150

1 5

Header Carded Boxed

DCT0938 DCT0338

150mm PVC Flexible Ducting

P.V.C Flexible Duct is a product that is extremely versatile in the ventilation industry. It doesn’t rot, is non-collapsing, is fire resistant, has an operating temperature of +6° to +50° and is available in a range of sizes from 100mm to 150mm. • • • • • • •

Fully complies to AS1530 Building code. DUCT CORE: Spiral wire reinforced PVC film construction. Non-collapsing/non-rotting. Vapour-proof. Fire retardant. TEMPERATURE RANGE: Maximum: +50˚C : Minimum: 6˚C. COLOUR: White PVC.

SEMIDUCT Semi Rigid Ducting

Diameter (mm)

Length (m)

Pack

Order Code

100

1.5 3

Boxed Loose

DCT0333 DCT0114

125

1.5 3

Boxed Loose

DCT0334 DCT0115

150

1.5 3

Boxed Loose

DCT0335 DCT0116

200

3

Loose

DCT0117

250

3

Loose

DCT0118

300

3

Loose

DCT0119

350

3

Loose

DCT0120

400

3

Loose

DCT0477

Semiduct Semi Rigid Ducting

SEMIDUCT is also known as semi-rigid aluminium ducting is a lightweight, flexible but strong corrugated aluminium duct. It is spiral wound with a unique interlocked and knotted continuous seam. It is self supporting over longer lengths and generally only needs fittings or mechanics at each end for support. • • • • • 74

Fully complies to the Building Code of Australia. DUCT CORE: Pure aluminium spiral wound with a unique interlocked and knurled continuous seam. Holds shape, self supporting. TEMPERATURE RANGE: Maximum: +250°C, Minimum: -30°C. COLOUR: Silver.

Manrose SOLID TUBE

Solid Tube - Rigid Steel Diameter Length (mm) (m)

Finish

Order Code

100

0.9

Galvanised

DCT0151

100

0.9

White

DCT0145

125

0.9

Galvanised

DCT0152

125

0.9

White

DCT0146

125

1.2

Galvanised

DCT0953

150

0.9

Galvanised

DCT0153

150

0.9

White

DCT0147

150

1.2

Galvanised

DCT0954

Acoustic Insulated R0.6 (40mm)

Solid Tube - White Plastic Diameter (mm)

Length (m)

Finish

Order Code

100

0.9

PVC

DCT1424

125

0.9

PVC

DCT1425

150

0.9

PVC

DCT1426

Manrose Low Profile Ducting Flat Channel Dimension (mm)

Equivalent Size (mm)

Length (m)

Order Code

110 x 54

100

1.5

DCT0013

204 x 60

125

1.5

DCT0519

220 x 90

150

1.5

DCT1443

300 x 25

100

1.5

DCT1460

Low profile ducting enables it to be concealed when installed along the top of wall units. It can also be fitted in ceiling voids and cavity walls, providing versatility whilst remaining unobtrusive. All Manrose system parts and channels are made from flame-retardant material. Four Low Profile System Sizes 110mm x 54mm: Suitable for applications requiring low extraction rates, such as ventilation of domestic bathrooms and toilets. With a 5940mm2 cross-section it provides efficient ducting for short, straight runs connecting to a 100mm round spigot.

204 x 60 Low Profile Ducting Flat channel

204mm x 60mm: Suitable for ducting of kitchen cooker hoods with 100, 125 or 150mm round exhaust spigots. The flat channel cross section of 12240mm2 increases efficiency. High Performance 220mm x 90mm: Suitable for applications requiring high performance extraction or supply. The flat channel cross section of 19800mm2 makes it highly efficient and higher extraction rates are achieved. Flat Ducting 300mm x 25mm: Suitable for applications where space is very limited.

75

Manrose LOW PROFILE DUCT FITTINGS

Low Profile Connectors

Horizontal 90° Bends

Vertical 90° Bends

Dimension (mm)

Order Code

Dimension (mm)

Order Code

Dimension (mm)

Order Code

110 x 54

DCT0014

110 x 54

DCT0125

110 x 54

DCT0126

204 x 60

DCT0520

204 x 60

DCT0524

204 x 60

DCT0525

220 x 90

DCT1442

220 x 90

DCT1448

220 x 90

DCT1447

300 x 25

DCT1459

300 x 25

DCT2097

300 x 25

DCT2099

Horizontal 45° Bend

Vertical 45° Bend

Dimension (mm)

Order Code

Dimension (mm)

Order Code

300 x 25

DCT2098

300 x 25

DCT1455

Short Adapter Rectangular: Round

Adapters Rectangular: Round

Horizontal T-Piece Connectors Dimension (mm)

Order Code

110 x 54

DCT1479

204 x 60

DCT1114

Flat Channel Reducers

Dimension (mm)

Order Code

Dimension (mm)

Order Code

Dimension (mm)

Order Code

110 x 54 : 100

DCT0127 (f)

110 x 54 : 100

DCT1482

110 x 54:204 x 60

DCT0136

110 x 54 : 100

DCT0131 (m)

204 x 60 : 125

DCT0526

204 x 60:220 x 90

DCT1452

220 x 90 : 150

DCT1446

300 x 25:204 x 60

DCT1456

300 x 25 : 100

DCT1461

(m) = Male (f) = Female

76

Designed to fit 204 x 60mm flat channel or airbrick.

Elbow Bends 100mm

Elbow Bends 125mm

Elbow Bends 150mm

Dimension (mm)

Order Code

Dimension (mm)

Order Code

Dimension (mm)

Order Code

110 x 54

DCT0124 (m)

204 x 60

DCT0522

204 x 60

DCT0523

110 x 54

DCT0015 (f)

220 x 90

DCT1440*

220 x 90

DCT1441*

204 x 60

DCT0521

300 x 25

DCT2096

220 x 90

DCT1444

300 x 25

DCT2095

*Rotating offset spigot *Rotating offset spigot

(m) = Male (f) = Female

Horizontal Bend Adjustable

Horizontal Airbrick Insert

Vertical Airbrick Insert

Dimension (mm)

Order Code

Dimension (mm)

Order Code

Dimension (mm)

Order Code

204 x 60

DCT1480

204 x 60

DCT0137

204 x 60

DCT1414

Double Airbrick Dimension (mm)

Order Code

232 x 138

DCT1450

Duct connection requires the following Reducer or Connector: 110 x 54: requires: DCT0136 204 x 60: requires: DCT0520

Comes complete with duct connector DCT0520.

Double Airbrick Adaptor

Double Airbrick Reducer

Dimension (mm)

Order Code

Dimension (mm)

Order Code

220 x 90:232 x 138

DCT1451

235 x 140

DCT1453

77

Manrose LOW PROFILE DUCT FITTINGS

Wall/Ceiling Plates Rectangular

Wall/Ceiling Plates Round

External Tube Grille

Dimension (mm)

Order Code

Dimension (mm)

Order Code

Diameter (mm)

Order Code

155 x 155 : 104 ø

DCT0148

155 x 155 : 110 x 55

DCT0016

100

DCT2206

170 x 170 : 130 ø

DCT0149

264 x 118 : 206 x 60

DCT0528

200 x 200 : 160 ø

DCT0150

A

External Louvred Grilles

Designed to fit directly into round solid tube, for systems ducted straight through an external wall.

B

Flat Channel Clips *2 clips are required to secure ducting.

Diameter (mm)

Order Code

Dimension (mm)

Order Code

100

DCT2200

110 x 54 (A)

DCT0134

125

DCT2201

204 x 60 (A)

DCT0527

150

DCT2202

220 x 90 (B)

DCT1445*

300 x 25 (B)

DCT1458*

Manrose In-Line Backdraught Shutters PVC

METAL

Duct Size (mm)

Order Code

Order Code

100

FAN0213

125

DCT0036

150

DCT0511

200

78

DCT2092

150mm PVC In-Line Backdraught Shutter

BRANCH TAKE OFF (B.T.O)

POLY

INSULATED

Duct Size (mm)

Order Code Order Code

100-100-100

DCT1439

125-125-125

DCT1501

150-150-150

DCT0091

DCT0875

200-150-150

DCT0719

DCT0876

200-200-150

DCT0460

DCT0877

200-200-200

DCT0461

DCT0878 200-200-200 Branch Take Off

• • • • • •

Manufactured from HDPE. UV stabilised, Heavy duty, robust. Smooth internal lines, no sharp edges. Positive lock duct tabs. Insulation meets AS 1530 part 3. Insulation material LDPE, thickness 5mm.

REDUCERS PVC Duct Size (mm)

Order Code

125-100

DCT2067

150-100

DCT2122

150-125

DCT2066

PVC Plastic

Duct Joiners/Spigots PVC

METAL LONG

METAL SHORT

METAL PLATE SPIGOTS

Duct Size (mm)

Order Code

Order Code

Order Code

Order Code

100

DCT0159

125

Metal Long

PVC Plastic

Metal Short

Metal Plate Spigots

DCT0037

150

DCT0723

DCT0059

DCT0935

200

DCT0724

DCT0071

DCT0939

250

DCT0725

DCT0339

DCT0940

Note 1. Products with the “order code” showing are generally ex. stock lines - other products are available to order. 2. Combinations of sizes which are not ex. stock can be made up using a suitable body and the relevant reducers and fitting joiners poly. 3. Nude combination fittings will be supplied in component form.

We do NOT assemble. 4. Insulated versions may not be ex-stock but will generally be available within 2-3 days of ordering. 5. Should you have an ongoing requirement for an item that is not a standard stock line – PLEASE discuss with us and we will review stocking the item for you.

79

Manrose Wall/Ceiling Grilles Fixed LOUVRE Duct Size (mm)

Colour

Order Code

100

White

DCT0025

100

Grey

DCT0024

100

Terracotta

DCT0026

125

White

DCT0041

125

Grey

DCT0039

125

Terracotta

DCT0040

150

White

DCT0063

150

Grey

DCT0062

150

Terracotta

DCT0064

200

White

DCT0340

230/250

White

DCT0073

300

White

DCT1979

150mm Wall/Ceiling Grille Fixed Louvre White

• Standard grille with some weather protection. • Removable insert for easy cleaning.

Manrose Wall/Ceiling Grilles EGGCRATE

Duct Size (mm)

Colour

Order Code

100

White

DCT0375

125

White

DCT0472

150

White

DCT0473

150mm Wall/Ceiling Grille Eggcrate White

• Improved air-flow characteristics. • Removable insert for easy cleaning.

DIMENSION INFORMATION Grille Description

Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

Fixed Louvre Grille

100

140 x 140

100

35

105

Fixed Louvre Grille

125

162 x 162

122

25

127

Fixed Louvre Grille

150

174 x 174

152

32

157

Fixed Louvre Grille

200

285 x 285

199

67

240

Fixed Louvre Grille

230/250

285 x 285

230

29

240

Fixed Louvre Grille

300

350 x 350

285

50

295

Eggcrate Grille

100

140 x 140

100

34

105

Eggcrate Grille

125

162 x 162

122

24

127

Eggcrate Grille

150

175 x 175

152

34

157

80

Manrose DESIGNER Wall Grilles STAINLESS Gravity Duct Size (mm)

Colour

Order Code

100

Stainless Steel

DCT2145

125

Stainless Steel

DCT2146

150

Stainless Steel

DCT2147

Manrose Wall Grilles PLASTIC Gravity

• High quality designer stainless steel finish. • Stainless Steel Grade 304.

Duct Size (mm)

Colour

Order Code

100

White

DCT0029

100

Grey

DCT0028

100

Terracotta

DCT0027

125

White

DCT0044

125

Grey

DCT0042

125

Terracotta

DCT0043

150

White

DCT0066

150

Grey

DCT0061

150

Terracotta

DCT0065

230/250

White

DCT2204

300

White

DCT1981

• Prevents back draughts & weather penetration.

DIMENSION INFORMATION

Grille Description

Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

Designer Gravity Grille

100

150 x 150

97

52

115

Designer Gravity Grille

125

180 x 180

120

52

140

Designer Gravity Grille

150

180 x 180

145

62

160

Standard Gravity Grille

100

140 x 140

100

35

105

Standard Gravity Grille

125

162 x 162

122

25

127

Standard Gravity Grille

150

174 x 174

152

32

157

Standard Gravity Grille

230/250

285 x 285

230

29

240

Standard Gravity Grille

300

350 x 350

285

50

295

The Designer Gravity Grille requires a minimum pressure to open.

• 20Pa - 100mm (DCT2145). • 30Pa - 125mm (DCT2146). • 30Pa - 150mm (DCT2147).

81

Manrose Wall/Ceiling Grilles Low Profile Duct Size (mm)

Description

Colour

Order Code

100

Circular

White

DCT1089

100

Square

White

DCT2223

125

Circular

White

DCT1090

125

Square

White

DCT2224

150

Circular

White

DCT1067

150

Square

White

DCT2225

• • • • •

150mm Low Profile Wall/Ceiling Grille

Low Profile eggcrate design improves airflow in extraction applications. Twist lock fascia for easy cleaning. Gib fixing clips included. Longer spigot for easy duct connection. Satin Silver & Chrome fascias available.

ACCESSORIES Duct Size (mm)

Description

Colour

Order Code

125

Circular Fascia Satin Silver

FAN2069

125

Square Fascia Satin Silver

FAN2068

125

Circular Fascia Chrome

FAN0757

125

Square Fascia Chrome

FAN0755

125

Circular Fascia White

FAN0748

125

Square Fascia White

FAN0747

150

Circular Fascia Satin Silver

FAN2070

150

Square Fascia Satin Silver

FAN2071

150

Circular Fascia Chrome

FAN0613

150

Square Fascia Chrome

FAN0598

150

Circular Fascia White

FAN0750

150

Square Fascia White

FAN0749

125

Spigot

White

DCT1074

150

Spigot

White

FAN0656

150mm Low Profile Wall/Ceiling Grille - Square/Circular

Accessories

DIMENSION INFORMATION Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

100

140

98

49

115

125

170

120

65

135

150

200

150

65

165

100

140 x 140 98

49

115

125

161 x 161 120

65

135

150

191 x 191 150

65

165

82

Manrose DESIGNER WALL/CEILING GRILLES SQUARE Duct Size (mm)

Colour

Order Code

150

White

DCT2236

150

Silver

DCT2237

• High quality designer finish available in either white or brushed aluminium silver. • Designed for bathroom extraction that blends into any decor. Designer Wall/Ceiling Grilles

DIMENSION INFORMATION Duct Size Face Size Spigot Diameter (mm) (mm) (mm)

Spigot Length Cut-Out (mm) Size (mm)

150

191 x 191

150

65

157

150

191 x 191

150

65

157

Manrose WALL/CEILING GRILLES CIRCULAR Duct Size (mm)

Colour

Order Code

100

White

DCT2185

125

White

DCT2186

150

White

DCT2187

• Concentric circular grille designed for extraction. 150mm Circular Wall/Ceiling Grille

DIMENSION INFORMATION Duct Size (mm)

Face Size (mm)

100

140

125 150

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

98

49

105

170

125

65

125

200

150

65

157

83

Manrose DESIGNER Ceiling Diffuser STAINLESS STEEL Duct Size (mm)

Colour

Order Code

100

Stainless

DCT2139

125

Stainless

DCT2140

150

Stainless

DCT2141

• High quality designer stainless steel finish - grade 304, Designed for internal extraction where a quality finish is required.

Designer Ceiling Diffuser

DIMENSION INFORMATION Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length Cut-Out Size (mm) (mm)

100

140

97

52

105

125

172

120

52

130

150

220

145

62

150

Manrose Flat Ceiling Diffuser Low Profile Duct Size (mm)

Colour

Order Code

150

White

DCT2208

• High quality designer finish. • Designed to supply air into your home, by pushing the air along the ceiling and down the walls. Included in Simx Home Ventilation Systems.

DIMENSION INFORMATION Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

150

220

148

80

210

84

Flat Ceiling Diffuser

Ceiling DIFFUSER CONE CENTRE Duct Size (mm)

Colour

Order Code

150

White

DCT1472

200

White

DCT1473

250

White

DCT1474

300

White

DCT1475

• • • • • • • •

Manufactured from ABS plastic. Designed for either supply or extract ventilation. When used to supply, the air will be pushed down into the room. These diffusers are used in heat transfer systems. Spring loaded fixing clips. Resistant to scratching and fading. Positive lock duct tabs. Adjustable screw in centre cone to ensure a balanced airflow.

200mm Ceiling Diffuser

DIMENSION INFORMATION Duct Size (mm)

Face Size Spigot (mm) Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

150

266

150

95

232

200

317

200

95

282

250

389

250

102

355

300

400

300

102

405

EGGCRATE ROUND DIFFUSER Duct Size (mm)

Colour

Damper

Order Code

150

Ice White

-

DCT2594

200

Ice White

-

DCT2595

150

Ice White

included

DCT2608

200

Ice White

included

DCT2609

• • • • •

Manufactured from ABS plastic. Designed for either supply or extract ventilation. Spring loaded fixing clips. Resistant to scratching and fading. Positive lock duct tabs.

150mm Eggcrate Round Diffuser

DIMENSION INFORMATION Duct Size (mm)

Face Size Spigot (mm) Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

150

240

150

95

215

200

290

200

95

260

85

CEILING DIFFUSER ECO Diffuser

Ceiling Diffusers Duct Size (mm)

Colour

Order Code

100 White DCT0020 ng system is an investment in your families personal comfort. As 125 White DCT0174 e placed on the type of ancillary products as to the type of unit 150 White DCT0058 200

White

DCT0068

s are manufactured from ABS (Acrylonitrile Butadiene Styrene) • Manufactured from A.B.S plastic. type of plastic that is used products like fridge • Designed for in either supply ortelephones, extract ventilation. • Fixing flange included, screws required. • Adjustable screw in centre cone. outside flange gives an attractive and unobtrusive finish. It is the

200mm Ceiling ‘ECO’ Diffuser

s used on our other plastic diffusers. So when you purchase

DIMENSION INFORMATION

products, you get a job that is aesthetically pleasing throughout

st.

Cone Centres are designed to suit the reverse cycle systems. Cone Centres allow adjustable control of the airflow by moving the centre up or down. This is achieved by a screwing technique. Clockwise decreases and shallows Unijet Cross Section the airflow while anti-clockwise increases and deepens the airflow.

ed not to just

ke other

Duct Size

Face Size (mm)

Spigot Diameter Spigot Length (mm) (mm)

Cut-Out Size (mm)

100

149

99

47

98

125

169

125

47

123

et disperses(mm) because it’s

gles.

mperature

150

186

148

50

148

200

235

198

50

198

Cone Centre Cross Section

Cone Centre Cross Section

d to suit the

ne Centres

f the airflow

r down. This

technique.

shallows the

se increases

Shallow Airflow Deep Airflow

poor quality remains long after the a low price has been forgotten. ty Ltd ABN 21 005 072 873

Heidelberg West 86Victoria Australia 3081 t Heidelberg Victoria 3081 Australia 1 (0)3 9458-3120 email [email protected] & New Zealand

Manrose DESIGNER Weatherproof COWLS STAINLESS COWLS Duct Size (mm)

Colour

Order Code

100

Stainless Steel

DCT2151

125

Stainless Steel

DCT2152

150

Stainless Steel

DCT2153

• High quality designer stainless steel finish. • Designed for use where adverse weather conditions are experienced. • Manufactured from a Stainless Steel Grade 304.

150mm Weatherproof Cowl

Manrose Weatherproof COWLS PLASTIC COWLS Duct Size (mm)

Colour

Order Code

100

White

DCT0018

100

Brown

DCT0019

125

White

DCT1030

150

White

DCT1031

150mm Weatherproof Plastic Cowl

• Used where adverse weather conditions are experienced. • 150mm Cowl, now includes mesh as standard

DIMENSION INFORMATION

Grille Description

Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

Designer Weatherproof

100

150 x 150

97

52

115

Designer Weatherproof

125

180 x 180

120

52

140

Designer Weatherproof

150

180 x 180

145

62

160

Standard Weatherproof

100

140 x 140

99

35

115

Standard Weatherproof

125

175 x 175

124

27

140

Standard Weatherproof

150

175 x 175

152

35

165

The Designer Weatherproof Cowl requires a minimum pressure to open. • 10Pa - 100mm (DCT2151). • 10Pa - 125mm (DCT2152). • 10Pa - 150mm (DCT2153).

87

Manrose DESIGNER Weatherproof Dome STAINLESS DOME Cowls Duct Size (mm)

Colour

Order Code

100

Stainless Steel

DCT2157

125

Stainless Steel

DCT2158

150

Stainless Steel

DCT2159

• • • • •

High quality stainless steel dome cowl for a modern stylish look. Designed for exhaust and supply ventilation. Generally mounted on an external wall, however they can be mounted internally. Manufactured from a Stainless Steel Grade 304. Insect mesh included.

dimension information Duct Size (mm)

Face Size (mm)

Spigot Diameter (mm)

Spigot Length (mm)

Cut-Out Size (mm)

Designer Dome Cowl

100

140

97

52

115

Designer Dome Cowl

125

180

120

52

140

Designer Dome Cowl

150

200

145

62

155

Grille Description

88

150mm Weatherproof Stainless Dome Cowl

Manrose Wall/Ceiling PLATE GRILLES Fixed Louvre Vent Plate Size (mm)

Colour

Order Code

245 x 80

White

DCT2194

245 x 80

Chrome

DCT2195

245 x 160

White

DCT2196

245 x 160

Chrome

DCT2197

245 x 245

White

DCT2198

245 x 245

Chrome

DCT2199

Wall/Ceiling Plate Grilles Fixed Louvre Vent

Adjustable Vent Plate Size (mm)

Colour

Order Code

245 x 80

White

DCT2188

245 x 80

Chrome

DCT2189

245 x 160

White

DCT2190

245 x 160

Chrome

DCT2191

245 x 245

White

DCT2192

245 x 245

Chrome

DCT2193

• • • •

Manufactured from PVC in either white or chrome. Designed for use when make-up air is required. Fixed Louvre provides maximum airflow. Adjustable Vent can be fully closed off when not required.

Wall/Ceiling Plate Grilles Adjustable Vent

Manrose Wall/Ceiling PLATE GRILLES PLATE FACE

Duct Size (mm)

Grille Type

Colour

Order Code

150

Fixed Louvre

White

DCT0352

150

Gravity Shutter White

DCT0353

230

Fixed Louvre

DCT0354

White

• For situations where no spigot is required.

Manrose Door GRILLE

Wall/Ceiling Plate Grilles Plate Face

Model No.

Description

Order Code

Door Vent

Internal Door Ventilator Grille

FAN0159

• This door grille allows make-up air into the room. • Dimensions: 455mm (h) x 90mm (w) to fit door with depth of 33mm.

89

Roof Cowls Duct Size (mm)

Description

Order Code

150

General Purpose Cowl

DCT0708

150

Heavy Duty Cowl

DCT0709 150mm General Purpose Cowl

• General Purpose Cowl - Low profile. • Low back pressure. - Added exhaust aperture area and deep vent coverage. - Recommended where high winds in exposed locations may drive rain into the vent. - Also recommended for use in high airflow air intake systems to prevent rain being sucked into the system. 150mm Heavy Duty Cowl

DIMENSION INFORMATION (mm) Models

A

B

DCT0708

275

125

DCT0709

275

140

Performance - DCT0708/DCT0709

DCT0708 and DCT0709 Pressure vs Volume

A

100

Pressure (Pa)

80

B

60

40

20

0

0

50

100

150

Volume (litre/sec)

90

A

200

250

B

Roof Cowl Kits

with Flashing & HDPE Tube Duct Size (mm)

Description

Order Code

150

General Purpose Kit

DCT0172

150

Heavy Duty Cowl Kit

DCT0710

150

General Purpose Lead Flashing Kit

DCT1095

• • • • •

General purpose cowl included. 0.5m HDPE Tube included. Flashing included (for metal based roofs). All fittings supplied. Optional lead Flashing available (extra cost).

150mm General Purpose Kit

Note: Lead Flashing (DCT0190) required for concrete tile roofs.

Plastic Reducers for HDPE Thru-Roof Tube (for thru-roof kits) Metric Size (mm)

Description

Order Code

150:125

150:125 reducer

DCT2066

150:100

150:100 reducer

DCT2122

• Reducers fit to the bottom of HDPE tube to adapt to smaller duct diameters where required.

Manrose Angled Roof Cowl Kit Duct Size (mm)

Description

Order Code

125

Angled Roof Kit

DCT2205

• • • •

General purpose through roof kit for smaller applications. 110mm PVC pipe - suitable for 125mm flexible ducting. To be mounted on tile roofs. Kit includes - Cowl, 0.5m of tube & weathering slate included. Angled Roof Kit

91

Manrose rangehood ducting kits • • •

There are three ducting options available, for the kitchen rangehood. Through an adjacent wall, through the soffit (under the eave) or up through the roof. Semi-Rigid ducting is used in our top of the range systems to reduce the rangehood system noise and increase air flow performance. Fully complies to AS/NZS 60335.2.80.

Thru Wall rangehood DUCTING Kits Duct Size (mm)

Description

Order Code

125

Rear Vent - Gravity Grille

DCT1162

150

Top & Rear Vent Weatherproof Cowl

DCT2592

• For added weather protection use the weatherproof cowl as included in DCT2592.

Soffit rangehood DUCTING Kits Duct Size (mm)

Description

Order Code

150

Thru Soffit

DCT1161

150

Thru Soffit - Galv Tube

DCT1259

150

Thru Soffit - Semi Rigid

DCT2323

• All systems include 3 metres of Aluminium Duct. • Galv Tube system also includes 900mm of Solid Tube.

Thru ROOF rangehood DUCTING Kits Duct Size (mm)

Description

Order Code

150

Thru Roof - Iron

DCT2324

150

Thru Roof - Tiled

DCT2325

FLASHING Iron Roof

92

Tiled Roof

Manrose Dryer Ducting Kit Rear Vent Thru Wall Duct Size (mm)

Order Code

100

DCT1263

Kit Includes: • • • • •

3m Flexible aluminium Aluduct (rated -30°C to 150°C). 0.75m Flat channel duct. 2 x Rectangular to Round 90° elbow bends. 100mm white eggcrate grille. All fixing and fittings.

Dryer Ducting Kit

Dryer Ducting features • • •

This ducting kit is designed for inverted and wall mounted dryers. Free standing dryers on the floor will require extra rectangular ducting and connector (Order Code: DCT0013 & DCT0014). These ducting kits suit dryers with a 100mm outlet. The square to round elbow will fit snugly onto most 100mm dryer outlets.

Pro Series Extension Kit Duct Size (mm)

Description

Order Code

150

Heat Trans Extension Kit

DCT2101

150

SimxHome Extension Kit

DCT2276

Kit Includes: • • • • •

Designed to extend your home ventilation or heat transfer systems to additional rooms. 1 x Y-Branch. 1 x 3 metres - 150mm Acoustic Insulated Ducting. 1 x Adjustable Circular Diffuser. All fixing and fittings included.

93

Manrose Accessories insect mesh

Duct Size (mm)

Description

Order Code

100

For 100mm Grilles

DCT0371

125

For 125mm Grilles

DCT0208

150

For 150mm Grilles

DCT0207

250

For 200mm & 250mm Grilles

DCT0373

150

Bird Mesh

DCT2263

Insect Mesh Accessory

Duct Straps and Duct Tape Duct Size (mm)

Description

Order Code

100mm

Ducting Strap

FAN0274

125mm

Ducting Strap

FAN0281

150mm

Ducting Strap

FAN0282

12mm x 3m

Hanging Strap

DCT2299

25mm x 50m

Hanging Strap

DCT0808

48mm x 5m

Duct Tape

DCT0173

48mm x 30m

Duct Tape

DCT0807

48mm x 60m

Duct Tape - *AS4254

DCT1132

Ducting Straps & Duct Tape

AS4254 Duct Tape

*AS4254 Duct tape DCT1132 - Temperature range -37°C - 127°C

Roof Flashings Description

Order Code

Flashing Roof Flashing - fits 110-160mm

DCT0180

Tiledek Roof Flashing - For use on concrete tile, clay tile and slate roofing

DCT0190

0.5m HDPE Tube 150mm

DCT0183

Stitching Screws (for roof fastening)

FAN0400

94

Roof Flashings

Heat Trans Systems

HEAT TRANS uses excess heat to warm other areas of the home by transferring it from one room to multiple rooms. Heat Trans is the professional brand in heat transfer systems and is the brand of choice for electrical contractors. Leading the market for over 15 years, Heat Trans is at the forefront of product development and innovation and the only heat transfer systems using acoustic insulated ducting and digital controllers.

How does Heat Trans work 01

02

03

Excess heat from your heat source will rise to ceiling level where it is trapped. This excess heat can reach temperatures of 30-35°C.

This excess heat can be effectively transferred to other rooms using a high quality fan and acoustic insulated ducting.

Air moves from the bedrooms back to the lounge creating a natural recirculation of warm air throughout the home. This will also make your home healthier by helping to reduce mould and mildew.

MODELS

MODEL

Order Code

Heat Trans One Room Kit

FAN0325

Heat Trans Two Room Kit

FAN0337

Heat Trans Three Room Kit

FAN0338

Pro-Series One Outlet Extension Kit

DCT2101

Heat Trans Summer-Vent Extension Kit

DCT1481

Heat Trans Thru Wall Kit

FAN0005

Heat Trans systems utilise excess heat throughout the home and cost as little as a light bulb to run.

Thomas and Betts | www.manrose.com.au | [email protected]

95

Heat Trans Systems

One Room Kit Outlet Size Description 150mm

Fan Speeds

Heat Trans One Room Kit

Order Code

1

FAN0325

Kit includes: • • • • • • •

1 x Ultecon Digital Thermostat Controller. 1 x 150mm High Performance Axial Flow Fan. 1 x 3 Metres - 150mm Acoustic Insulated Ducting. 1 x 3 Meters - 150mm Insulated Ducting. 1 x Circular Inlet Grille. 1 x Adjustable Circular Design Outlet Diffuser. All Fittings and Fixings Included.

Two Room Kit Outlet Size Description 150mm

Heat Trans Two Room Kit

Fan Speeds Order Code 2

FAN0337

Kit includes: • • • • • • • •

1 x Ultecon Digital Thermostat/ Fan Speed Controller 1 x 150mm Multi-Speed High Performance Fan. 2 x 3 Metres - 150mm Acoustic Insulated Ducting. 2 x 3 Metres - 150mm Insulated Ducting. 1 x Branch Take-Off (Splitter). 1 x Circular Inlet Grille. 2 x Adjustable Circular Design Outlet Diffusers. All Fittings and Fixings Included.

Three Room Kit Outlet Size Description 150mm

Heat Trans Three Room Kit

Fan Speeds 3

Order Code FAN0338

Kit includes: • • • • • • • •

96

1 x Ultecon Digital Thermostat/ Fan Speed Controller. 1 x 200mm Multi-Speed High Performance Fan. 3 x 3 Metres - 150mm Acoustic Insulated Ducting. 2 x 3 Metres - 200mm Insulated Ducting. 1 x Double Branch Take-Off (Three Way Splitter). 1 x Circular Inlet Grille. 3 x Adjustable Circular Design Outlet Diffusers. All Fittings and Fixings Included.

Heat trans Features

The Ultecon digital thermostat controller measures and displays the temperature of your lounge and lets you preset your preferred room temperature. When your lounge temperature exceeds your preferred room temperature the system will automatically start to transfer the excess heat to other rooms in your home. The 2 and 3 room systems also offer fan speed control, which allows you to set your preferred fan speed giving you ultimate control over the volume of heated air being transferred. Superior Fans High quality multi-speed fans for optimum airflow ventilation in the home that cost as little as a light bulb (between 70W and 120W) to run. These high quality fans have been specifically selected to ensure correct airflow and pressure levels are achieved. Whisper quiet The unique acoustic insulated ducting reduces air transfer noise to a ‘whisper quiet’ level. Better temperature retention is achieved, ensuring optimal heat transfer of excess warm air.

One Room Controller

Adjustable diffusers Easily adjustable to allow balancing of the airflow into each room. Simply twist the centre section of the diffuser to allow more or less air into each room. Or simply close any diffuser when the room is not in use.

Optional extras

Two/Three Room Controller

Summer feature Introduce fresher cooler air into your home in summer with the Summer-Vent Extension Kit, to enable year round use of your system. With the inlet grille installed under your soffit, fresher cooler air is filtered using a high efficiency F7 filter and is distributed throughout your home via your Heat Trans outlets. The system is controlled via a standard wall switch which operates the motorised damper to start drawing air from outside. Note: When the summer feature is working the lounge warmed room inlet is switched off via the damper and will not receive the cooled air directly from outside, however due to air pressure a natural re-circulation occurs throughout the home. Summer Feature Extension Kit

Extension kit The Pro-Series One Outlet Extension Kit is designed to extend your standard three room Heat Trans system so you can distribute warm air to an extra room within your home. The extension kit gives you the flexibility to add additional outlet/s to your Heat Trans system. By adding additional outlet/s to your system you are simply dividing the available heated air amongst more rooms. Note: All Heat Trans kits can be extended. 1 Room kits can be extended to a max length of 12 metres ( 6 metres supplied in kit). 2 Room kits can be extended to a max length of 21 metres (12 metres supplied in kit). 3 Room kits can be extended to a max length of 24 metres (15 metres supplied in kit).

Pro-Series One Outlet Extension Kit

Thomas and Betts | www.manrose.com.au | [email protected]

97

Alpha-Numeric index Order codes DCT0013

75

DCT0126

76

DCT0358

72

DCT0525

76

DCT1161

92

DCT0014

76

DCT0127

76

DCT0359

72

DCT0526

76

DCT1162

92

DCT0015

77

DCT0131

76

DCT0360

40

DCT0527

78

DCT1164

73

DCT0016

78

DCT0134

78

DCT0362

40

DCT0528

78

DCT1169

40

DCT0018

87

DCT0136

76

DCT0366

40

DCT0633

73

DCT1171

40

DCT0019

87

DCT0137

77

DCT0367

72

DCT0634

73

DCT1176

73

DCT0020

86

DCT0145

75

DCT0368

72

DCT0635

73

DCT1216

73

DCT0024

80

DCT0146

75

DCT0369

72

DCT0636

73

DCT1224

73

DCT0025

80

DCT0147

75

DCT0370

72

DCT0708

90

DCT1259

92

DCT0026

80

DCT0148

78

DCT0371

94

DCT0709

90

DCT1263

93

DCT0027

81

DCT0149

78

DCT0373

94

DCT0710

91

DCT1268

73

DCT0028

81

DCT0150

78

DCT0375

80

DCT0719

79

DCT1414

77

DCT0029

81

DCT0151

75

DCT0377

72

DCT0723

79

DCT1424

75

DCT0036

78

DCT0152

75

DCT0380

72

DCT0724

79

DCT1425

75

DCT0037

79

DCT0153

75

DCT0399

72

DCT0725

79

DCT1426

75

DCT0039

80

DCT0159

79

DCT0400

72

DCT0807

94

DCT1439

79

DCT0040

80

DCT0172

91

DCT0401

72

DCT0808

94

DCT1440

77

DCT0041

80

DCT0173

94

DCT0402

72

DCT0833

73

DCT1441

77

DCT0042

81

DCT0174

86

DCT0403

72

DCT0834

73

DCT1442

76

DCT0043

81

DCT0180

94

DCT0404

72

DCT0835

73

DCT1443

75

DCT0044

81

DCT0183

94

DCT0405

72

DCT0836

73

DCT1444

77

DCT0058

86

DCT0189

56

DCT0406

72

DCT0875

79

DCT1445

78

DCT0059

79

DCT0190

94

DCT0409

72

DCT0876

79

DCT1446

76

DCT0061

81

DCT0207

94

DCT0410

72

DCT0877

79

DCT1447

76

DCT0062

80

DCT0208

94

DCT0411

72

DCT0878

79

DCT1448

76

DCT0063

80

DCT0328

72

DCT0412

72

DCT0935

79

DCT1450

77

DCT0064

80

DCT0329

72

DCT0413

72

DCT0936

74

DCT1451

77

DCT0065

81

DCT0330

72

DCT0414

72

DCT0937

74

DCT1452

76

DCT0066

81

DCT0331

72

DCT0415

72

DCT0938

74

DCT1453

77

DCT0068

86

DCT0332

72

DCT0416

72

DCT0939

79

DCT1455

76

DCT0071

79

DCT0333

74

DCT0417

72

DCT0940

79

DCT1456

76

DCT0073

80

DCT0334

74

DCT0418

72

DCT0953

75

DCT1458

78

DCT0088

72

DCT0335

74

DCT0460

79

DCT0954

75

DCT1459

76

DCT0089

72

DCT0336

74

DCT0461

79

DCT1030

87

DCT1460

75

DCT0091

79

DCT0337

74

DCT0472

80

DCT1031

87

DCT1461

76

DCT0114

74

DCT0338

74

DCT0473

80

DCT1067

82

DCT1472

85

DCT0115

74

DCT0339

79

DCT0477

74

DCT1074

82

DCT1473

85

DCT0116

74

DCT0340

80

DCT0511

78

DCT1076

82

DCT1474

85

DCT0117

74

DCT0343

72

DCT0519

75

DCT1089

82

DCT1475

85

DCT0118

74

DCT0344

72

DCT0520

76

DCT1090

82

DCT1479

76

DCT0119

74

DCT0352

89

DCT0521

77

DCT1095

91

DCT1480

77

DCT0120

74

DCT0353

89

DCT0522

77

DCT1097

61

DCT1481

95

DCT0124

77

DCT0354

89

DCT0523

77

DCT1114

76

DCT1482

76

DCT0125

76

DCT0357

72

DCT0524

76

DCT1132

94

DCT1501

79

98

Alpha-Numeric index Order codes DCT1519

38

DCT2196

89

FAN0055

24

FAN0282

94

FAN0519

28

DCT1520

38

DCT2197

89

FAN0060

46

FAN0325

95

FAN0520

28

DCT1521

38

DCT2198

89

FAN0061

46

FAN0325

96

FAN0521

28

DCT1522

38

DCT2199

89

FAN0064

36

FAN0326

48

FAN0529

56

DCT1979

80

DCT2200

78

FAN0065

36

FAN0327

48

FAN0530

56

DCT1981

81

DCT2201

78

FAN0071

14

FAN0328

36

FAN0531

56

DCT2066

79

DCT2202

78

FAN0072

14

FAN0329

36

FAN0532

56

DCT2066

91

DCT2204

81

FAN0074

14

FAN0330

50

FAN0533

56

DCT2067

79

DCT2205

91

FAN0075

14

FAN0337

95

FAN0534

56

DCT2092

78

DCT2206

78

FAN0080

24

FAN0337

96

FAN0535

56

DCT2095

77

DCT2208

84

FAN0082

24

FAN0338

95

FAN0589

12

DCT2096

77

DCT2223

82

FAN0083

24

FAN0338

96

FAN0590

12

DCT2097

76

DCT2224

82

FAN0085

44

FAN0346

16

FAN0591

12

DCT2098

76

DCT2225

82

FAN0090

46

FAN0348

16

FAN0594

12

DCT2099

76

DCT2236

83

FAN0091

46

FAN0355

26

FAN0595

12

DCT2101

93

DCT2237

83

FAN0101

36

FAN0357

50

FAN0596

12

DCT2101

95

DCT2263

94

FAN0102

36

FAN0358

50

FAN0598

12

DCT2120

40

DCT2276

93

FAN0107

26

FAN0360

50

FAN0598

22

DCT2121

40

DCT2299

94

FAN0109

26

FAN0361

50

FAN0598

82

DCT2122

79

DCT2323

92

FAN0110

26

FAN0372

62

FAN0604

12

DCT2122

91

DCT2324

92

FAN0119

14

FAN0374

16

FAN0605

12

DCT2139

84

DCT2325

92

FAN0120

14

FAN0397

60

FAN0606

12

DCT2140

84

DCT2592

92

FAN0121

14

FAN0400

94

FAN0609

12

DCT2141

84

DCT2594

85

FAN0122

14

FAN0405

46

FAN0610

12

DCT2145

81

DCT2595

85

FAN0123

14

FAN0406

46

FAN0611

12

DCT2146

81

DCT2608

85

FAN0124

14

FAN0409

24

FAN0613

12

DCT2147

81

DCT2609

85

FAN0126

14

FAN0410

24

FAN0613

22

DCT2151

87

FAN0005

95

FAN0127

14

FAN0411

24

FAN0613

82

DCT2152

87

FAN0012

46

FAN0135

24

FAN0412

60

FAN0614

22

DCT2153

87

FAN0013

46

FAN0136

24

FAN0413

60

FAN0615

22

DCT2157

88

FAN0015

63

FAN0137

24

FAN0420

40

FAN0616

34

DCT2158

88

FAN0016

63

FAN0138

24

FAN0431

38

FAN0617

34

DCT2159

88

FAN0017

36

FAN0140

24

FAN0431

40

FAN0618

34

DCT2185

83

FAN0018

36

FAN0141

24

FAN0438

40

FAN0619

34

DCT2186

83

FAN0021

26

FAN0146

28

FAN0452

26

FAN0620

22

DCT2187

83

FAN0038

20

FAN0148

28

FAN0455

16

FAN0621

22

DCT2188

89

FAN0041

20

FAN0153

63

FAN0467

50

FAN0623

22

DCT2189

89

FAN0042

20

FAN0155

63

FAN0481

28

FAN0625

61

DCT2190

89

FAN0044

14

FAN0156

63

FAN0482

28

FAN0626

61

DCT2191

89

FAN0046

14

FAN0157

63

FAN0499

20

FAN0644

82

DCT2192

89

FAN0047

14

FAN0159

89

FAN0501

20

FAN0656

82

DCT2193

89

FAN0048

14

FAN0213

78

FAN0504

20

FAN0685

61

DCT2194

89

FAN0053

24

FAN0274

94

FAN0505

20

FAN0686

61

DCT2195

89

FAN0054

24

FAN0281

94

FAN0518

28

FAN0690

61

Thomas and Betts | www.manrose.com.au | [email protected]

99

Alpha-Numeric index Order codes FAN0691

61

FAN1053

42

FAN2127

42

FAN0732

22

FAN1060

56

FAN2162

30

FAN0735

22

FAN1096

63

FAN2200

30

FAN0738

22

FAN2029

38

FAN2205

103

FAN0739

56

FAN2030

38

FAN2206

103

FAN0740

56

FAN2031

38

FAN2213

102

FAN0748

82

FAN2032

38

FAN2214

102

FAN0750

82

FAN2033

38

FAN2229

104

FAN0755

12

FAN2034

38

FAN2230

104

FAN0755

22

FAN2035

38

FAN2286

58

FAN0755

82

FAN2036

38

FAN2287

58

FAN0757

12

FAN2037

40

FAN2303

54

FAN0757

22

FAN2038

40

FAN2402

62

FAN0757

82

FAN2040

16

FAN2423

54

FAN0803

40

FAN2040

16

FAN2424

54

FAN0804

40

FAN2041

16

FAN2425

54

FAN0827

40

FAN2042

16

FAN2426

54

FAN0829

52

FAN2043

16

FAN2444

62

FAN0830

52

FAN2049

32

FAN2465

18

FAN0841

60

FAN2050

32

FAN2902

58

FAN0884

18

FAN2051

32

FAN2903

58

FAN0885

18

FAN2066

48

FAN4395

58

FAN0916

44

FAN2067

48

FAN4396

58

FAN0921

49

FAN2068

12

FAN4397

58

FAN0940

30

FAN2068

22

LHT0081

30

FAN0963

62

FAN2068

82

LHT0140

30

FAN0967

56

FAN2069

12

FAN0981

63

FAN2069

22

FAN0982

63

FAN2069

82

FAN0983

63

FAN2070

12

FAN0995

30

FAN2070

22

FAN0997

49

FAN2070

82

FAN1002

56

FAN2071

12

FAN1004

42

FAN2071

22

FAN1005

42

FAN2071

82

FAN1006

42

FAN2076

40

FAN1007

42

FAN2078

46

FAN1009

56

FAN2101

38

FAN1014

30

FAN2101

40

FAN1015

30

FAN2101

62

FAN1043

60

FAN2104

63

FAN1048

42

FAN2124

42

FAN1050

42

FAN2125

42

FAN1051

42

FAN2126

42

100

Energy Efficient Ventilation Solutions

Lo-Carbon

Lo-Carbon fans from Vent-Axia offer up to 70% energy savings by utilising market leading motor technology, to help reduce your carbon footprint.

Lo-Carbon Thomas & Betts are proud to be the distributor of the Vent-Axia Lo-Carbon range of ventilation fans. MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens.

Vent-Axia Lo-Carbon long life motors last 5 times longer than conventional AC motors. The extended life of the Lo-Carbon fans is due to the use of a new generation of high quality ball bearing motor. These high quality ventilation fans are specifically designed for bathrooms, extracting moisture laden air quietly & effectively.

Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141 Western Australia

South Australia

Unit 2, 22 Hammond Rd Cockburn Central WA 6164

86A Richmond Rd Keswick SA 5035

Victoria

Queensland

2/13-15 Brough St Springvale VIC 3171

26 Turbo Drive Cooparoo QLD 4151

Tasmania

Newcastle

Electrical Agencies 4 Linear Court Moonah TAS 7009

Nick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322

National Support Centre Phone: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Web: www.manrose.com.au

Energy Efficient Ventilation Solutions

67% en savin ergy g

The distributors of Manrose Ventilation fans are proud to distribute the Vent-Axia Lo-Carbon range. These fans offer up to 70% energy savings, utilising market leading motor technology, which lasts considerably longer than conventional AC motors. These high quality ventilation fans are specifically designed to extract moisture-laden air quietly and efficiently. The Vent-Axia Lo-Carbon range includes solutions for wall, ceiling, window and roof mounted applications. With energy savings in mind these models operate efficiently at lower wattage levels, the Silhouette LCS150 for example operates at 8.2W as opposed to a standard ceiling fan which operates at 25W, a saving of 67%.

Lo-Carbon

VENT-AXIA LO CARBON vent-a-light fan 100 VENT-A-Light

Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 70% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearing motors. 100mm Lo Carbon axial in-line shower fan and light kit. Suitable for shower enclosures and wet areas. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation.

• Low Power consumption - 70% energy savings. • Complete with 3m flexible ducting, white grille and light transformer. • 1 of 2 speeds selectable at installation. • High quality ball bearing motors. • Modern aesthetics, includes blue neon “on light”. • Fan IPX4 rated. • 5 Year Warranty. 70% sav energy ing s

Performance Size (mm)

Model No.

100

Vent-a-light B

100

Vent-a-light T

Extract Performance* Watts

Sound

(m3/hr)

(l/s)

(W)

dB(A) @3m

Lo-Carbon Vent-a-Light Standard

110

31

6.5 +35

23

FAN2229

Lo-Carbon Vent-a-Light Timer

110

31

6.5 +35

23

FAN2230

Description

Order Code

* 1 of 2 speeds selectable at installation * Please note the energy savings only apply to the fan motor, there is still a 35W centre lamp.

Switching Options 1. Standard Model - operates from remote switch (not supplied).

NOTE: All fan flow rates quoted are free air delivery.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

Thomas & Betts | www.manrose.com.au | [email protected]

VENT-AXIA LO CARBON wall/ceiling mounted fans Silhouette® 150

Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 67% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearing motors. With a slim profile of only 19mm, Silhouette blends in with the wall surface to provide an unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run to exhaust outside. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. • 19mm stylish low profile grille. • Low Power consumption - 67% energy savings. • Downstream airflow guide vanes for improved pressure development. • 1 of 2 speeds selectable at installation. • High quality ball bearing motors. • Modern aesthetics, includes blue neon ‘on light’. • Fan IPX4 rated. • 5 Year Warranty.

67% sav energy ing s

Performance Extract Performance* Watts Sound

Size (mm)

Model No.

Description

150

LCS150B

150

LCS150T

(m3/hr)

(l/s)

(W)

dB(A) @3m

Lo-Carbon Wall/Ceiling Silhouette Standard

165

46

5

35

241

67

8.2

43

Lo-Carbon Wall/Ceiling Silhouette Timer

165

46

5

35

241

67

8.2

43

Order Code

FAN2213

FAN2214

* 1 of 2 speeds selectable at installation

Wattage Comparison Size (mm)

Model No.

Description

Wattage

150

XFLP150

Manrose Pro-Series Wall/Ceiling Fan

25W

150

LCS150

Vent-Axia Lo-Carbon Wall/Ceiling Fan

8.2W

Energy Savings

16.8W

67% ENERGY SAVINGS

Switching Options 1. Standard Model - operates from remote switch (not supplied).

NOTE: All fan flow rates quoted are free air delivery.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

Thomas & Betts | www.manrose.com.au | [email protected]

VENT-AXIA LO CARBON wall/ceiling mounted fans Silhouette® 100

Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to 63% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball bearing motors. With a slim profile of only 17mm, Silhouette blends in with the wall surface to provide an unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run to exhaust outside. Models include 2 speeds selectable at installation to customise the fan to each application and come complete with a neon to indicate operation. • 17mm stylish low profile grille. • Low Power consumption - 63% energy savings. • Downstream airflow guide vanes for improved pressure development. • 1 of 2 speeds selectable at installation. • High quality ball bearing motors. • Modern aesthetics, includes blue neon “on light”. • Fan IPX4 rated. • 5 Year Warranty.

63% sav energy ing s

Performance Extract Performance* Watts Sound

Size (mm)

Model No.

Description

100

LCS100B

100

LCS100T

(m3/hr)

(l/s)

(W)

dB(A) @3m

Lo-Carbon Wall/Ceiling Silhouette Standard

95

26

7.5

34

60

16

3.4

38

Lo-Carbon Wall/Ceiling Silhouette Timer

95

26

7.5

34

60

16

3.4

38

Order Code

FAN2205

FAN2206

* 1 of 2 speeds selectable at installation

Wattage Comparison Size (mm)

Model No.

Description

Wattage

100

XF100

Manrose Wall/Ceiling Fan

20W

100

LCS100

Vent-Axia Lo-Carbon Wall/Ceiling Fan

7.5W

Energy Savings

12.5W

63% ENERGY SAVINGS

Switching Options 1. Standard Model - operates from remote switch (not supplied).

NOTE: All fan flow rates quoted are free air delivery.

2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.

Thomas & Betts | www.manrose.com.au | [email protected]