Mariner Stainless Steel Floodlight

26 downloads 26842 Views 4MB Size Report
APPLICATIONS. The Hubbell Lighting Mariner Flood is ideal for the following marine applications: • Offshore production platforms. • FPSOs. • Jetties. • Refineries.
HUBBELL LIGHTING

The Mariner™ Stainless Steel Floodlight UL LISTED AND CSA CERTIFIED FOR MARINE AND HAZARDOUS ENVIRONMENTS

®

features & benefits FEATURES & BENEFITS

• Elevated Ambient Suitability

Meets requirements in high temperature environments

• “Restricted Breathing” listed Provides lower, safer T-Ratings

• Superior Lighting Performance and High Wattage Capability up to 1000W

Lowers installation and maintenance costs and improves lighting with asymmetric distribution and higher efficiencies • Marine Listed for hosedown capability and reliability, American Bureau of Shipping (ABS) listed for shipboard use Multiple listings support broader range of applications • Remote ballast 316 SS housing Delivers high ambient capability (up to 65°C), high wattage, minimal pole loading, reduced installed cost, and performance reliability • Universal Remote Head with adjustable lamp socket Accepts various HID lamps, reducing inventory costs • 800W MH Remote Ballast drives 2x400W MH Remote Heads

Why Mariner?

Reduces installed cost • Low EPA of 2.9 ft2 Minimizes pole loading, reducing installed cost • Electro-Reg® and Pulse Start metal halide ballast systems

Rugged and tough.

Reduces installation, maintenance and operating costs • Type 316 Stainless Steel Housing – 16 gauge

All 316 stainless steel.

Ensures low corrosion, long life, and durability, reducing maintenance costs • Rugged, quick release 316 SS Lens Latches

Versatile.

No hardware seizing or disassembly during relamping, saving maintenance time and money Only a screwdriver or blunt tool is needed • 316 SS Safety Lens Door Chains

High ambient.

Enables hands-free relamping during electrical maintenance Saves time, money, and provides safety • 316 SS Mounting Yoke Reliable, safe installation

Lower T-Ratings.

• Highly efficient (above 85%) photometrics Excellent asymmetric/forward throw distribution Minimizes number of required fixtures to deliver desired

Marine and Shipboard listed.

light levels, better uniformity and savings in energy costs • 316 SS Cord Grip 1⁄ 2 " Connector (SFMM) Provides watertight seal, corrosion resistant

Corrosion resistant.

• 316 SS Conduit Hub 3 ⁄ 4 " (SFM2/SFMH2/SSRB)

Lower costs.

• Hot-Dipped Galvanized Steel Mounting Accessories

Maintains grounding continuity Provides watertight seal, corrosion resistant

Corrosion resistant in marine and corrosive environments assuring reliable installation

The Mariner™ THE MOST VERSATILE, COMPLETE STAINLESS STEEL FLOODLIGHT IN THE INDUSTRY Available in three styles: SFMM for marine and non-hazardous environments SFM2 for marine/Class I, Division 2 / Class I, Zone 2 environments SFMH2/SSRB remote ballast box/remote head system Each delivers: • High ambient capability for improved performance and increased reliability in high temperature applications • Electro-Reg® and Pulse Start metal halide lamp source options – proven ballast technology for reduced operating costs • American Bureau of Shipping (ABS) listing – rated and ready for shipboard use • High wattages and increased light levels – universal remote ballast capability provides minimal pole loading, ease of installation • Global voltages – floodlights for use almost anywhere in the world • “Restricted Breathing” – means lower T-Ratings to meet hazardous location applications • Superior optical performance

APPLICATIONS

applications

The Hubbell Lighting Mariner Flood • Offshore production platforms • FPSOs • • Refineries • • Offshore drilling rigs • • Barges • • Pulp and paper • • Ocean going vessels • Commercial fishing vessels

is ideal for the following marine applications: Jetties Ports Wharfs Waste water and sewage treatment Any type of marine, washdown, corrosive, abrasive, or dirty environment where dependable afloodlighting is needed

The Mariner is manufactured under the ISO 9002 Quality

System Certification Program

More

LISTINGS

Rugged, yet easy-to-open 316 SS Latches. No hardware involved.

Two 316 SS Lens Chains allow hands-free maintenance

SFMM comes with 316 SS Cord Grip. SFM2 comes with 316 SS Conduit Hub.

SFMM •ANSI/UL 1572 HID Fixtures for Marine Outdoor and Wet Locations •CSA C22.2 9.0-96 General Requirements •Type Approval American Bureau of Shipping (ABS) •IP66/67 •NEMA 4X SFM2/SFMH2/SSRB •ANSI/UL 844 Hazardous Locations Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Groups IIC, IIB, IIA* •CSA C22.2 137-M1981 Hazardous Locations Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Groups IIC, IIB, IIA* ExnR, AxnR Restricted Breathing (SFM2/SFMH2) •ANSI/UL 1572 HID Fixtures for Marine Outdoor and Wet Locations •Type Approval American Bureau of Shipping (ABS) •IP66/67 •NEMA 4X

listin

* Safe installation of light fixtures in Class I, Division 2/Zone 2 classified areas depends on many factors, including operating temperature ratings. See T-Rating charts.

e Power. More Perf DIMENSIONS: SFMM, SFM2, SFMH2 18.3" (465mm)

CATALOG LOGIC (INTEGRAL BALLAST 150W - 400W) 8.6" (220mm)

19.7" (500mm) 25.2" (640mm)

11.0" (279.4mm) 4.2" (106.3mm)

10.16"(258.06mm) Center Hole 0.88" (22.2mm) 1.5" (39.75mm)

10.8" (274.3mm)

2 Holes 0 56" (14.3mm)

2.0" (50.8mm)

3.1" (79.5mm)

ENTRY SFMM: 1/2" CORD GRIP SFM2: 3/4" CONDUIT HUB

X

X

XX

Series

Wattage

Lamp Type

Voltage

Options

SERIES SFMM Stainless Flood Marine SFM2 Stainless Flood Marine Class I, Division 2

VOLTAGE 55 480V 6 Tri-Tap® (120/277/347V) 8 Quad-Tap® (120/208/240/277V) E 220/240V, 50 Hz P 220V, 60 Hz

WATTAGE 15 150W HPS, PS 17 175W MH, MV 5 25 250W HPS, MH, MV, PS 40 400W HPS, MH, MV, PS

OPTIONS F(X)1,2,3 Fusing (X indicates voltage) RS Hot Re-Strike (150W HPS) QS4 Quartz Standby PCR(X)1,2,3,4 Photo Control EA6 Elevated Ambient (40°C, 55°C, 65°C) capabilities, see chart for applicable wattages RB Restricted Breathing Housing allowing lower T-Ratings for SFM2 Series only. Fixture provided with test port entry on side.

1 To specify correct voltage, replace X with 1-120V, 2-208V, 3-240V, 4-277V, 5-480V, 6-347V. 2 Not UL 1572 Marine Outdoor Listed. 3 Fixture not CSA listed with these options. 4 Available in SFMM only. Not suitable for hazardous locations. 5 250W Pulse Start not available in 480 volt. 6 See table for Supply Wire Ratings

SFMM/SFM2 INTEGRAL BALLAST SUPPLY WIRE RATINGS (SUFFIX “EA”)

SFMM/SFM2* INTEGRAL BALLAST AMBIENT SUITABILITIES & T-RATINGS* (SUFFIX “EA”)

175W MH 250W MH, PS 400W MH, PS

AMBIENT TEMPERATURE 40°C 55°C 65°C 90°C 110°C 90°C 110°C 110°C — 110°C — —

150W HPS 250W HPS 400W HPS

90°C 90°C 110°C

90°C 110°C —

110°C — —

175W MV 250W MV 400W MV

90°C 90°C 110°C

110°C 110°C —

110°C — —

WATTAGE/LAMP TYPE

XX

LAMP TYPE H Metal Halide S High Pressure Sodium C Mercury Vapor W Pulse Start (PS) Metal Halide (lamp included)

2.0" (50.8mm)

20.2" (513mm)

SFMM

WATTAGE/ LAMP TYPE

T-RATINGS & AMBIENT TEMPERATURE 40°C 55°C 65°C CLASS I DIV 2/ ZONE 2

CLASS I ZONE 2 ExnR AExnR

CLASS I DIV 2/ ZONE 2

CLASS I ZONE 2 ExnR AExnR

CLASS1 DIV 2/ ZONE 2

CLASS I ZONE 2 ExnR AExnR

T1 T1 T1 T1

T4 T4 T3 T3

T1 T1 T1 —

T3 T3 T1 —

T1 T1 — —

T3 T3 — —

150W HPS 250W HPS 400W HPS

T2A/T2 T1 T1

T4 T3 T3

T2 T1 —

T4 T3 —

T2 — —

T3 — —

175W MV 250W MV 400W MV

T1 T1 T1

T4 T3 T3

T1 T1 —

T4 T3 —

T1 — —

T3 — —

150W 175W 250W 400W

PS MH MH, PS MH, PS

* For standard SFM2 (less suffix EA), apply T-Ratings from 40°C column above.

gs

formance. More Ve CATALOG LOGIC (REMOTE HEAD 350W - 1000W) ADJUSTABLE LAMP SOCKET

SFMH2

XX

XX

Series

Entries

SERIES SFMH2 Stainless Steel Remote Head, Class I, Div. 2 Marine ENTRIES 3/4" Conduit Hub C1 C2 20mm Conduit Hub 3/4" Conduit Hub C3 Restricted Breathing C4 20mm Conduit Hub Restricted Breathing

Lamp Type LAMP TYPE* UH Universal Head 350W Pulse Start 400W HPS, MH, Electro-Reg,® Pulse Start 1000W HPS HH 1000W MH

* Mandatory to designate for listed light sources. Lamps not included.

Universal head provides adjustable lamp socket which allows multiple lamp flexibility

CATALOG LOGIC (REMOTE BALLAST 350W - 1000W)

SSRB

XX

XXXX

X

X

XX

Series

Entries

Wattage

Lamp Type

Voltage

Options

SERIES SSRB Stainless Steel Remote Box, Class I, Div. 2 Marine Class I, Div 2/Zone 2 Marine ENTRIES 3/4" Conduit Hub C1 C2 20mm Conduit Hub WATTAGE 0350 350W Pulse Start only 0400 400W HPS. MH, PS, E-Reg 0800 One ballast for two 400W MH remote heads (120/277V, 480V only) 1000 1000W HPS, MH LAMP TYPE E Electro-Reg® Metal Halide (400W only) H Metal Halide S High Pressure Sodium W Pulse Start (PS) 350/400W

SSRB 316SS remote ballast box with reversible door

DIMENSIONS: SSRB 20.0" (508mm)

1 To specify correct voltage, replace X with 1-120V, 2-208V, 3-240V, 4-277V, 5-480V, 6-347V. Fixtures with Fusing option will not be UL 1572 Marine Outdoor certified, as the UL 1572 spec does not allow marine listing of fixtures with fusing. Fixtures with Fusing not CSA listed.

WATTAGE 350W PS* 400W MH

0.62" diameter (16mm)

9.25 (235mm) 6.0 (152mm)

11.25 (286mm)

OPTIONS F(X)1 Fusing (X indicates voltage)

SSRB MOUNTING DISTANCES

6.63" (168mm)

15.25" (387mm)

VOLTAGE 1 120V (for Electro-Reg only) 2 208V (for Electro-Reg only) 3 240V (for Electro-Reg only) 4 277V (for Electro-Reg only) 5 480V 6 Tri-Tap® (120/277/347V) 8 Quad-Tap® (120/208/240/277V) 9 120/277V 60 Hz (for Dual 400W MH only) E 220/240V, 50 Hz F 347V (for Electro-Reg only) P 220V, 60 Hz

400W 400W 400W 800W

PS* E-REG HPS MH

1000W MH Supply wire rating is 90°C

1.5" (38mm)

1000W HPS * Consult factory for mounting distances longer than 15'

MAX. DIST. (ft.) 15* 75 (#14 wire) 125 (#12 wire) 15* 15 50 75 (#14 wire) 125 (#12 wire) 125 (#14 wire) 205 (#12 wire) 75

PHOTOMETRICS

WATTAGE/ LAMP TYPE

T-RATINGS & AMBIENT TEMPERATURE 40°C 55°C 65°C CLASS I DIV 2/ ZONE 2

350W PS 400W MH, PS 400W E-REG 1000W MH* 400W HPS 1000W HPS

T1 T1 T1 T1 T1 T1

CLASS I ZONE 2 ExnR AExnR

T3 T3 T3 T2 T3 T2

CLASS I DIV 2/ ZONE 2

T1 T1 T1 T1* T1 T1

CLASS I ZONE 2 ExnR AExnR

T3 T3 T3 T2* T3 T2

CLASS1 DIV 2/ ZONE 2

T1 T1 T1 —

CLASS I ZONE 2 ExnR AExnR

T3 T3 T3 —

T1 T1

T3 T2

* 1000W MH has maximum ambient capability of 50°C.

10

60

3

12

1

1

1

34

6

2

1

213 203 177 144 78

28

3

1

847

405 391 352 277 146 56

10

1

1638 2927

33 465

50 40 750 718 647 485 234 75

17

1

950 957 893 642 279 87

22

1

889 937 883 627 255 85

25

1

81

26

1

319 314 283 223 146 79

26

1

258 243 207 170 125 72

24

1

297 283 223 159 107 61

19

228 214 186 140 91

49

13

1

922

188 187 105 101 50

35

7

1

674

32

56

16

20

10

16

2

1

153

22

18

16

8

4

4

1

73

7

8

5

3

3

1

1

28

30 20

32045

10

23490

0

17219 573 592 556 403 186 12622

9253

10 20

9253

30

3645

40

60 70 80

WATTAGE 150/175W HPS, MH, PS 250W MH, PS 250W HPS 400W MH, PS 400W HPS — 350 PS 400 MH, PS 400 HPS 400 E-REG 800W MH 1000W MH 1000W HPS

WEIGHT 42 lbs. 44 lbs. 46 lbs. 47 lbs. 49 lbs. 35 lbs. 32 lbs. 32 lbs. 34 lbs. 47 lbs. 49 lbs. 41 lbs. 48 lbs.

5286 5223 4668 3478 1749 736 199 12 VERTICAL TOTALS 80 70 60 50 40 30 20 10 0 10 20 30 43 50 60 70 80 90

TEST NO.: SOURCE: LAMP: LAMP WATTS: LCL:

BEAM FIELD

HP-07477 HPS ED-18 clear 400 5.75"

2418 1391 1100 1149

21,351

LUMENS: IES/NEMA TYPE: MAX. BEAM CANDLEPOWER: AVG. MAX. CANDLEPOWER: TOTAL EFFICIENCY:

50,000 6H X 6V 36,447 32,045 85%

HORIZONTALLY

VERTICALLY

LUMENS

EFFICIENCY

81.8 118.4

41.0 118.6

22,196 40,591

44% 81%

AXIAL CANDELA TRACES

31999 28799 25600 LUMINOUS INTENSITY - CANDELA

1 Not UL 1572 Marine Outdoor listed. 2 Available in SFMM only. Not suitable for hazardous locations.

3702

ANGLE FROM BEAM AXIS (DEGREES HORIZONTAL)

ACCESSORIES Catalog No. Description 4024C-M38 Hot-Dipped Galvanized Steel Slipfitter for 2" pipe (23⁄8" O.D.) tenon, includes hardware 4040-M38 Hot-Dipped Galvanized Steel Wall/Pole Bracket, includes hardware 4090-M38 Hot-Dipped Galvanized Cross Arm Fitting for horizontal trunnion, includes hardware PTL11,2 Photocontrol - Twist-Lock® Cell 120V 1,2 PTL8 Photocontrol - Twist-Lock Cell 120-277V PTL51,2 Photocontrol - Twist-Lock Cell 480V PTL61,2 Photocontrol - Twist-Lock Cell 347V PSC1,2 Photocontrol Shorting Cap -Twist-Lock Mount (completes circuit) 1 SFM-LR ⁄8" diameter, 3' Steel Safety Cable, Hot-Dipped Galvanized

3831

6783 4972

50

WEIGHTS DESCRIPTION SFMM/SFM2 SFMM/SFM2 SFMM/SFM2 SFMM/SFM2 SFMM/SFM2 SFMH2 Remote Head SSRB SSRB SSRB SSRB SSRB SSRB SSRB

5

145 99 107 71

70

HORIZONTAL TOTALS

SFMH2 REMOTE HEAD AMBIENT SUITABILITIES & T-RATINGS

LUMEN DISTRIBUTION

80 ANGLE FROM BEAM AXIS (DEGREES VERTICAL)

ersatility.

AVERAGE OF RIGHT-LEFT SIDES ISO CANDELA CURVES

22400 19200 16000 12800 9600 6400

4024C-M38 (includes hardware)

4040-M38 (includes hardware)

4090-M38 (includes hardware)

3200

0 90

70

50

30

LEFT/DOWN VERTICAL - HEAVY LINE

PTL

PSC

10

10

DEGREES

30

50

70

90

UP/RIGHT HORIZONTAL - THIN LINE

HUBBELL LIGHTING’S FULL LINE OF ENVIRONMENTAL LIGHTING

EWL

SSHZ

HLF

PERFORMER

N4E

N4E

KEMLUX

KEMLUX

HLEZ

NVQ

HLMB

HLE

HUBBELL LIGHTING, INC. 2000 Electric Way Christiansburg, VA 24073-2500 PHONE: (540) 382-6111 FAX: (540) 382-1526 VISIT OUR WEB SITE:

HUBBELL CANADA, INC. 870 Brock Road South Pickering, Ontario L1W 1Z8 PHONE: (905) 839-1138 FAX: (905) 839-9108

www.hubbell-ltg.com © HUBBELL INCORPORATED

Printed in USA DECEMBER 2000

HAZ-030 R