Lockable Carry Case. Operating Manual. Certificate of Calibration. Accessories.
RC-102 Rubber Field Case with built-in prop stand, adjustable hand & neck.
S p e c i f i c a t i o n s
DMS2E
Probe Zero Adjustment Automatic microprocessor controlled V-Path Correction Automatic microprocessor controlled Measuring Range .025" to 25.00" (.66 to 635 mm); depends on material, probe, sur face, condition, and temperature Digital Displayed Resolution .001 or .01 inches; .01 or .1 mm Reading Update Rate 4 or 8 Hz; 32 Hz in Min Cap Mode Gain Automatic or adjustable in 1 dB steps Receiver Bandwidth 500 KHz to 15 MHz
Base Instrument Package DMS 2E A-Scan Ultrasonic Thickness Gauge 4 AA Alkaline Batteries Lockable Carry Case Operating Manual Cer tificate of Calibration
Accessories RC-102 Rubber Field Case with built-in prop stand, adjustable hand & neck straps, & waist belt PCCBL-841 9 Pin Serial PC Cable PRTCBL-842 Parallel Printer Interface Cable PRTCBL-518 Serial Printer Cable FB-143 Field Accessor y belt with removable pouches LCD-124 Tearaway protective screen overlays LCC-315 Locking Transpor t Case UltraMATE® Windows™95/NT Data Control Software Program
Options EM-166 Expanded Memor y AC-214 A/C Power
Specifications Operating Principle Ultrasonic pulse/echo Measurement Modes Dual-element, Dual-element thru coat Big Digits Display Mode Selectable .75" thickness digits easily seen at a quick glance
Material Velocity Range 39,400 to 393, 662 in/sec.; 1000 to 9999 m/sec. Power Supply 4 ea. Standard, AA size, alkaline or nicad rechargeable batteries
Ultrasonic Thickness Gauge
Memory Retention 5 years File Structures Linear,Grid, Custom Linear, and UltraPIPE files Microgrids Creatable on the job for all file structures from 2 x 2 to 9 x 9 symmetrical sizes Alphanumeric Input On-command vir tual keyboard at press of direct access key Inspection Comments/Notes 1 to 16 user-defined, 16 character comments per reading
Fast Battery Charger External, 5 hour maximum charge time
Store/Recall A-Scans Recall A-Scans for viewing, printing, re-setting instrument or deleting
Battery Life (operating time) 40 hours continuous use at 4 Hz update and backlight & Min Cap of f
Special Functions
Instrument Shut-off Manual or automatic after 1 to 15 minutes of non-use I/O Port Bidirectional RS232 selectable: baud rate (maximum 115,200), printer, direct repor ts Multilingual Operation English, German, French, Italian, and Spanish Operating Temperature Range +10° to +120°F (–10° to + 50°C) Size 10.1" H x 5.1" W x 1.2" D (256 mm x 129 mm x 30 mm) Weight 1.6 lbs. (725 g) with batteries Hazardous Area Operation Safe operation as defined by MIL-STD810E, Method 511.3, Procedure 1. Warranty A full two-year warranty on par ts and labor
Data Recorder Memory Capacity Up to 150,000 thickness readings/1100 A-Scan waveforms with full instrument parameters (expandable up to 318,000 thickness readings/2400 A-Scan waveforms)
Last reading comparison T-Min/T-Max with LED and horn alarms Send/advance controls File copy, insert, append and delete locations Date and time documentation Programmable from a PC or on-site
Software Products UltraMATE®LITE Data Control Program UltraMATE®Data Control & Analysis Program UltraPIPE® Engineering-based, Analysis, Inspection Scheduling & Management program for piping and plant equipment
Display Type: High-resolution, ¼ VGA, 240 x 320 pixels, graphic waveform LCD, 2.8" x 3.75" (71 x 95 mm) backlight, adjustable contrast Thickness Display 5 digit, .5" (12.7 mm) or .75" (19 mm) Range .115" to 25.000"(2.9 to 635 mm) in steel
A-Scan Display Grid Graticule: edge, partial, dots, full Trigger echo indicator: carat(s) at top A-Scan waveform: solid or hollow adjustable gates and thresholds to select proper echo(es) and prevent unwanted echo(es) from affecting the thickness measurement
Freeze: quick capture of coupled A-Scan and thickness reading Status Symbols: Indicate measurement status Data Recorder Display: Data files, 4 lines of inspection data, in linear or spreadsheet view, file type specific information
Select from a large variety of dual element probes
M
G
O
J K P
L H
F
B
A
Q D
C N
I
E M odel
D e s ig n a tio n
P r o b e C a b le
C o n ta c t D ia m e te r
M e a s u r in g R a n g e in S te e l
TC –560
TopC O AT
K BA –531A 532
.6 2 5 ” (1 3 .9 m m )
C o a tin g .0 0 2 – .0 8 0 ” (.0 5 – 2 .0 m m )
D M - 4 0 1 -G P *
G e n e ra l P u r p o s e
K B A -5 3 3 / 5 3 3 A
.7 0 0 " (1 7 .8 m m )
.0 6 0 " -8 .0 " (1 .5 -2 0 0 m m )
< 1 3 0 ºF (5 4 ºC ) º1 3 0 ºF (5 4 ºC )
D M -4 0 1 - G P REM*
G e n e ra l P u r p o s e R e m o te S end
K B A -5 3 3 / 5 3 3 A
.7 0 0 " (1 7 .8 m m )
.0 6 0 " -8 .0 " (1 .5 -2 0 0 m m )
< 1 3 0 ºF (5 4 ºC )
A
FH2E
F in g e rtip
P o tte d
B
F H 2 E -D *
F in g e rtip
P o tte d
C
F H 2 E -D -R E M *
R e m o te S e n d
P o tte d
D
K B 5 5 0 F H **
F in g e rtip
P o tte d
.3 8 0 " (9 .6 m m ) .3 8 0 " (9 .6 m m ) .3 8 0 " (9 .6 m m ) .3 7 5 " (9 .5 m m ) .3 0 0 " (7 .6 m m ) .2 0 0 " (5 m m ) .1 2 0 " (3 m m ) .6 2 5 " (1 5 .9 m m ) .6 2 5 " (1 5 .9 m m ) .4 7 5 " (1 2 .1 m m ) .6 3 5 " (1 6 .2 m m ) 1 .2 5 " (3 1 .8 m m ) .5 5 0 " (1 4 .0 m m ) .7 0 0 " (1 7 .8 m m ) .5 5 0 " (1 4 .0 m m ) .5 0 0 " (1 2 .7 m m ) .3 7 5 " (9 .5 m m )
.0 3 0 " -2 .0 " (.7 5 -5 0 m m ) .0 3 0 " -2 .0 " ( .7 5 50m m ) .0 3 0 " -2 .0 " ( .7 5 50m m ) .0 6 0 " -2 .0 " ( 1 .5 50m m ) .0 2 5 " -1 .0 " (.6 25m m ) .0 2 5 " -1 .0 " (.6 25m m ) .0 2 5 " -.5 0 " (.6 13m m ) .0 6 0 " -8 .0 " ( 1 .5 200m m ) .0 6 0 " -8 .0 " ( 1 .5 200m m ) .0 5 0 " -8 .0 " ( 1 .2 200m m ) .2 0 0 "m in . (5 m m m in ) .2 0 0 "m in . (5 m m m in ) .0 3 0 " -2 .0 " ( .7 5 50m m ) .0 6 0 " -8 .0 " ( 1 .5 200m m ) .0 3 0 " -2 .0 " ( .7 5 50m m ) .0 4 0 " -1 0 .0 " (1 .0 254m m ) .0 6 0 " -2 .0 " ( 1 .5 50m m )
E
DA312
T h in M a te r ia ls
K BA 532
F
K BA 525
5 m m F o o tp r in t
P o tte d
G
D A 3 1 2 B 1 6 **
3 m m F o o tp r in t
P o tte d
H
K BA 560
G e n e ra l P u r p o s e
K BA 531
I
K B A 5 6 0 -D *
G e n e ra l P u r p o s e
K BA 531
J
DA301
G e n e ra l P u r p o s e
K BA 533
K
DA303
P e n e tr a tio n
K BA 533
L
D P -1 0 4
H ig h P e n e tra tio n
K BA 532
M
F H 2 E -W R
W e a r R e s is ta n t
P o tte d
N
K B A 5 6 0 -W R
W e a r R e s is ta n t
K BA 531
O
F H 2 E -D -W R *
W e a r R e s is ta n t
P o tte d
P
H T 4 0 0 /4 0 0 A ^
H ig h T e m p .
K BA 535 / 536
Q
K B 5 5 0 B T H **
S tu d d e d B o ile r Tube
C -B T H
AgfaNDT .com AgfaNDT.com
Tem p R ang e
< 1 3 0 ºF < 1 3 0 ºF < 1 3 0 ºF < 1 3 0 ºF < 1 3 0 ºF < 1 3 0 ºF < 1 3 0 ºF < 4 5 0 ºF < 2 5 0 ºF < 1 4 0 ºF < 1 4 0 ºF < 1 3 0 ºF < 1 3 0 ºF < 4 5 0 ºF < 1 3 0 ºF < 1 0 0 0 ºF < 1 3 0 ºF
Visit the NDT Super Site, AgfaNDT.com, for more information on Krautkramer's DMS2 Thickness Gauge and to learn more about Agfa NDT's complete line of Ultrasonic, X-ray, Digital and Film systems
Agfa NDT Inc.
Agfa NDT GmbH
Agfa NDT Ltd.
Agfa NDT SA
50 Industrial Park Road Lewistown, PA 17044 Tel : (717)242-0327 Fax : 717/242-2606
Robert-Bosch-Str 3 D–50354 Huerth (Efferen) Germany Tel : +49-2233-6010 Fax: +49-2233-601402
Millburn Hill Road University of Warwick Science Park Coventry, England CV4 7HS United Kingdom Tel : +44 (0) 24 7669 0069 Fax : +44 (0) 24 7685 3016
68, Chemin des Ormeaux F–69760, Limonest France Tel : +33-472-179220 Fax : +33-478-475698 E-mail:
[email protected]