Feb 5, 2010 - cycle has 3 high-pressure and 3 low-pressure surface heat ... generator, where it generates steam from liquid water at inlet (secondary circuit). ... Under such conditions the collectors are driven to stagnation conditions, that is, ... a large combined-cycle gas turbine exhaust. .... LP Turbine ...... Compressor,.
Entropy 2010, 12, 243-261; doi:10.3390/e12020243 OPEN ACCESS

entropy ISSN 1099-4300 www.mdpi.com/journal/entropy Article

Improvement of Energy Conversion/Utilization by Exergy Analysis: Selected Cases for Non-Reactive and Reactive Systems Daniele Fiaschi and Giampaolo Manfrida * Dipartimento di Energetica “Sergio Stecco”, Università degli Studi di Firenze, Via C. Lombroso 6/17, 50135 Firenze, Italy; E-Mail: [email protected] * Author to whom correspondence should be addressed; E-Mail: [email protected]. Received: 29 December 2009; in revised form: 2 February 2010 / Accepted: 4 February 2010 / Published: 5 February 2010

Abstract: Exergy analysis is a powerful and systematic tool for the improvement of energy systems, with many possible applications in both conversion and utilization of energy. Here we present selected applications, with a special attention to renewable energy systems (solar), covering both design and operation/control. After these applications to non-reactive systems, potential ways of reducing the large irreversibilities connected to reactive systems (combustion) are considered, with special reference to chemically-recuperated gas turbine cycles and topping high-temperature fuel cells. Keywords: exergy; optimization; energy systems

Nomenclature ηex,dir ηex,ind ρflow Δppcc Δptot ηpump θ Ac , ,

Direct expression of collector exergy efficiency Indirect expression of collector exergy efficiency Flow density [kg/m3] circuit lumped head losses [bar] Overall circuit head losses [bar] Efficiency of circulating pump collector tilt angle [°] Collector surface area [m2] Exergy destruction due to the absorber plate – luid temperature difference W Exergy destruction due to the pump work [W]

Entropy 2010, 12

244

Exergy destruction due to the sun – absorber plate temperature difference [W]

,

, , , ,

I Ib Id mflow Qu S Ta Tfi Tfo Tml Tp Tsun Utot vflow vwind Wpump

Overall exergy input to solar collector [W] Circulation pump exergy inlet [W] Exergy from the sun [W] Exergy loss due to incomplete absorption of the incident radiation [W] Exergy loss due to heat lost to the environment [W] Overall exergy losses and destructions [W] useful exergy extracted from the collector [W] Overall incident solar radiation per square meter [W/m2] Beam incident solar radiation per square meter [W/m2] Diffused incident solar radiation per square meter [W/m2] Water mass flowrate [kg/s] Useful heat extracted by the working fluid [W] Solar radiation actually absorbed by the collector [W/m2] Environmental temperature [C] collector inlet temperature [C] collector outlet temperature [C] Log-mean inlet—outlet fluid temperature difference [K] Collector plate temperature [C] Sun temperature [K] Overall plate—environment heat transfer coefficient Flow velocity [m/s] Wind velocity [m/s] Pump work [W]

1. Introduction Exergy analysis is a recognized method for the analysis and optimization of energy systems [1–6]. It is widely documented both in energy conversion (with special reference to thermal or thermochemical options) and energy utilization (from cooling to industrial heat/process applications). Without pretending to be exhaustive, the present paper presents some applications ranging from design to control, applied to non-reactive and reactive energy systems. 2. Non-Reactive Energy Systems 2.1. Case 1—332 MWe Steam Power Plant (Energy Conversion; Design/Optimization) The first test case is a reference 332 MWe Power plant (Figure 1). Its layout has been slightly simplified with respect to a true power plant, basically neglecting shaft seal steam recovery. The steam cycle has 3 high-pressure and 3 low-pressure surface heat exchangers (HP_ST1-3; LP_ST1-3); a Mixing Feedwater Heater (MFH, serving also as de-aerator for removal of non-consensable gases) separates the feedwater line in the high and low-pressure sections. The main data are collected in Table 1. The system is simulated using EES32 [7]; from the base case (ENEL power plant data), a

Entropy 2010, 12

245

genetic algorithm optimization was run in order to determine the set of the seven extraction pressures (Table 1) that optimize the plant thermal efficiency. A small margin for improvement was found, with some adjustments of extraction pressures that should not impair the assumed values of the steam turbine efficiencies. Figure 2 collects the results of the 19 exergy destructions and losses calculated for the steam power plant. The inlet exergy is assumed at steam cycle level, that is, the exergy difference between points (12)–(10) for the main flow stream and points (15)–(14) for the RH flow stream; exergy destructions/losses were calculated according to standard practice [1,2,5]. It is interesting to notice that the optimization process leads to the reduction of some exergy destructions, and to the increase of some others. The optimized set of extractions sees a notably lower value of the LP1 pressure, and an increase in the HP extraction pressures; indirectly, varying the mass flow rates of the extractions causes a variation of the steam turbine exergy destructions. Figure 1. Schematic of 332 MWe Power Plant.

2.2. Case 2—Solar Thermal Steam Power Plant (Energy Conversion; Standard/Optimum Control) The second test case is a solar thermal energy conversion plant, whose schematic is shown in Figure 3. The arrangement corresponds to common practice encountered in large solar thermal fields, such as is documented in references [8–10]. The solar collector field is usually arranged as a solar farm of parabolic-trough collectors, which are heating a high-temperature heat transfer fluid. The heat transfer fluid is maintained in liquid conditions even at very high temperatures (up to 400 °C for silicon oils such as Therminol VP-1 [13]); it is circulated through a primary circuit to the steam generator, where it generates steam from liquid water at inlet (secondary circuit). Steam is then expanded in a traditional superheated steam cycle, usually including a Mixing Feed-water Heater (MFH) for an effective removal of non-condensable gases. This is the typical layout for reference power sizes larger than 1 MWe, while for lower power ratings Rankine Organic Cycles (ROC)

Entropy 2010, 12

246

[8,13,18] are gaining increasing popularity. The discussion in the following is aimed at control applications, and it applies both to steam and ROC power cycles. Figure 2. Relative exergy destructions/losses for the 332 MWe Power Plant.

0,030 0,025 Original

0,020

Gen_26

0,015 0,010

Table 1. Steam Cycle parameters (bold = calculated). Variable

Base Case

Optimized

ηHPT ηIPT ηLPT TSH = TRH °C pCond bar pSH bar p13 bar p14 bar p16 bar p18 bar p19 bar p21 bar p23 bar η ηx Generation

0,88 0,89 0,90 538 0,05 170 78,3 37,75 16,94 7,24 2,6 0,76 0,29 0,4687 0,869 1

0,88 0,89 0,90 538 0,05 170 88,03 49,91 19,02 6,454 2,661 0,7295 0,1481 0,4710 0,871 26

HP3_SE_ EXD

MFH

HP2_SE_ EXD

HP1_SE_ EXD

LP_DRAIN_REC_ EXD

LP3_SE_ EXD

LP2_SE_ EXD

LP1_SE_ EXD

Feed_P_ EXD

Cond_ExtrP_ EXD

Cond_ EXL

LP_ST4_ EXD

LP_ST3_ EXD

LP_ST2_ EXD

LP_ST1_ EXD

IP_ST2_ EXD

IP_ST1_EXD

HP_ST2_EXD

0,000

HP_ST1_EXD

0,005

Entropy 2010, 12

247 Figure 3. Solar Thermal Energy conversion plant.

Tfo

MFH

Tfi Control of solar thermal power plants has not up to now received much attention from the scientific community. As these power plants are still in the start-up phase, the first goal is to demonstrate that they are efficient and reliable: in order to do that, and considering the variability of the solar source over time, the steam plant is usually operated under fixed thermodynamic conditions (pressure and temperature). A typical current control law [10,15] uses a fixed set-point temperature at collector outlet, Tfo; consequently, the temperature of superheated steam T6 is also fixed; the flow rates in the primary and secondary system circuits are adjusted according to the availability of solar radiation. Seasonal adjustments to Tfo and T6 are usually necessary. This operation law has some technical sense, as it minimizes thermal expansion problems - a common critical issue in solar farms using a large number of parabolic-trough collectors. However, a strong reduction of the flow rate through the primary and secondary loops results when the solar radiation is very low, at morning or in the evening. Under such conditions the collectors are driven to stagnation conditions, that is, operation with a very high heat loss to the environment, and efficiency close to zero [11]. In order to minimize such problems, storage devices are added to the circuit, or external heating integration is used (e.g., with an auxiliary burner using a conventional fuel). In some cases, silicon oil is substituted with molten salts [14], which must be maintained under liquid conditions even at night: this is obtained using heat from a large combined-cycle gas turbine exhaust. The authors believe that when trying to efficiently use natural energy resources that are subject to large and/or un-expectable variations in time, such as solar, wind or wave energy, the energy conversion plant should be operated following as close as possible the conditions dictated by nature. In the case of solar energy, this means that when radiation is low we should accept operation of the solar thermal conversion plant not only with reduced flow rate, but also with adjusted (reduced) parameters (steam pressure and temperature). Exergy is a very useful tool in this case [13,16,17]. The data presented in Figure 4 was calculated for a typical commercial parabolic trough collector. It demonstrates that the collector outlet temperature (for fixed inlet temperature conditions) should be chosen in order to maximize the exergy efficiency of the collector. The maximum exergy condition (ME) is strongly affected by solar radiation. From the curves shown in Figure 4, the following conclusions can be drawn:

Entropy 2010, 12

248

- In order to have low thermal losses and transfer most of the heat to the fluid, the solar collector should be operated at a high thermal efficiency, with a low average absorber temperature (Tfo + Tfi)/2. The collector transfers large quantities of heat to the fluid, but it is low-quality heat. - If the average absorber temperature is raised, the collector transfers less heat to the fluid (but with a higher quality); the heat loss to the environment is increased. If I is low or Tfo is raised too much, the collector reaches shut-off conditions (no useful energy output, zero efficiency) - Between these two conditions (which depend on Ta and I, as well as on Tfo), a condition of maximum exergy output (referring to the collector) must exist. Referring to the plant schematic in Figure 3, the collector inlet temperature Tfi is determined by two conditions: - The pinch temperature difference in the steam generator. - The operating pressure of the MFH, which in turn determines the saturated liquid conditions at its outlet. Figure 4. (a) Exergy efficiency of a parabolic trough solar collector under different radiation conditions. (b) Thermal efficiency of the collector. 0,3

ηx

I = 800 W/m

2

I = 600 W/m

0,26

A = 0,75

ηcoll

2

B=0,0001123 [kW/m K]

2

2

Tfo = 650 K

I = 400 W/m

2

Tfo = 580 K

0,56

Tfo = 505 K

(a)

[(Tfo + Tfi)/2-Ta ] / I 300

350

400

450

500

(a)

550

2

C=0,00000128 [kW/m K ]

0,6

0,22

0,18 250

0,64

Tfi = 500 K

600

650

700

750

0,52 250

[(Tfo + Tfi)/2-Ta ] / I 275

300

325

350

375

400 [K] 425

(b)

Looking at the steam generator temperature/surface diagram, it makes sense that, when radiation is low and it is not possible to reach the design value of the collector outlet temperature Tfo, the plant operator should accept to operate the steam circuit with a lower pressure (and consequently a lower T4), and a lower superheated steam temperature T6 (e.g., maintaining the same values of the approach and pinch temperature differences, respectively DTa and DTp). It is true that the steam turbine would operate under off-design; however, a reduced mass (and volume) flow rate would result also if the plant were controlled with fixed set-point temperatures (Tfo and T6), so anyway off-design operation is unavoidable (without a heat storage for short time periods, or external heat integration for longer periods). In Rankine Organic Cycles [13,18], the turbine exit conditions are usually in the super-heated state, and a Regenerative Heat Exchanger (RHE) pre-heating the liquid before entry to the steam generator must be added. The effectiveness of the RHE and the condenser pressure substitute the MFH condition (steam case). The maximum exergy operating conditions (shown graphically in Figure 4) can be determined by recursive analytical solution [16] only when the thermal efficiency curve of the collector (Figure 4b) is linearized. However, it is relatively simple to develop a numerical procedure, starting from a guess value (for example, obtained by linearization of the efficiency curve, such as in [16]), and searching

Entropy 2010, 12

249

directly for the maximum exergy condition. In the present case a chord iterative method is applied. A typical result is shown for a typical day in June in Figure 6; fixed set-point control (Figure 6a) is compared to ME control (Figure 6b). The value of the fixed DT was chosen as that maximizing efficiency at noon. It is clear that ME control causes a remarkable decrease of the collector exergy loss (heat released to the environment), at the expense of a larger collector heat transfer exergy destruction. The result is a higher overall efficiency of the whole energy conversion plant (Figure 7). Figure 5. Pinch diagram of the steam generator.

Figure 6. Solar thermal power plant exergy destructions/losses. (a) Fixed-DT control 1

0,8 0,6

Rel. exergy destruction

C o lle cto r He a t L o ss C o lle cto r He a t tra n sfe r S G H e a t T ra n s fe r H P Tu rb i n e L P Tu r b in e C o nd e n s er

J u n e D T _ f ix

0,4 0,2

Collector Heat Loss Collector Heat Transfer

0,8

SG Het Transfer HP Turbine LP Turbine

0,6

Condenser

0,4

June ME

0,2 0

0 6

8

10

12

14

16

6

18

8

T im e of th e da y ( Ju ne )

10

12

14

Time of the day (June)

Figure 7. Solar thermal power plant efficiency (a) Fixed-DT control (b) ME control. Overall conversion efficiency

Rel. exergy destruction

1

(b) ME control

0,18

DT_fix ME

0,15 0,12 0,09 0,06 0,03 0 6

8

10

12

14

Time of the day (June)

16

18

16

18

Entropy 2010, 12

250

2.3. Case 3—Solar Collector Design (Thermal Utilization/Heat Transfer; Design) Exergy analysis of solar collectors—calculation model Solar collectors are designed to collect heat from the sun and not to convert heat into mechanical or electrical work; however, exergy analysis is interesting for three reasons: 1. To determine the quality of collected heat, on the basis of its temperature, in order to somehow merge the two main performance parameters of solar collectors: efficiency and temperature rise of the fluid; 2. To assess the main sources of collector exergy destructions and losses and their amount, which is closely related to temperature levels of the fluid and of the environment (the latter is the reference restricted dead state); 3. To keep the exergy consumption of the pump (mechanical work) in consideration when the collector thermal performance is determined. This can be of great help in collector design because it could suggest, for example, to limit some design parameters (diameters of tube, roughness, piping layout, etc.) that lead to high values of pressure losses, and consequently, to high energy consumption of the pump. The model for exergy analysis was added to a design tool of solar collectors, developed in EES environment [7], on the basis of a classic approach [19]. The total exergy input to the collector is the sum of two terms: 1. Exergy from the sun

,

with sun temperature defined as the 75% of the

1

sun considered as a black body, in agreement with [20]: 0,75 5777 , Ta is the environmental reference temperature. I is the overall radiation (beam + diffused) per unit surface and AC is the collector surface area. 2. Work Exergy from the circulating pump (Wpump): The overall exergy input is then given by: ,

,

,

.

The useful exergy extracted from the collector system is the amount related to the fluid (water) temperature increase: . Where Tfi and Tfo are inlet and outlet flow temperature, respectively, whereas cp is the constant pressure fluid specific heat. Thus, the direct expression of collector exergy efficiency is: ,

The indirect exergy balance can be built by the calculation of the following detailed exergy losses/destructions: a) Exergy loss due to incomplete absorption of the incident radiation coming from sun (a fraction is reflected by the cover—in case of glazed collectors—and the transmitted fraction is not

Entropy 2010, 12

251

completely absorbed by the plate). Thus, the loss is given by the difference between incident and actually absorbed radiation (S): 1

,

1

b) Exergy loss due to heat dispersed to the environment: 1

,

Where Utot is the overall plate—environment heat transfer coefficient and Ac the collector surface area. c) Exergy destruction due to the temperature difference between the sun and the absorber plate: 1

,

;

1

d) Exergy destruction due to the temperature difference between the absorber plate and the fluid: 1

,

1

;

where Tml is the log-mean inlet—outlet fluid temperature difference: . e) Exergy destruction due to pump work, whose only purpose is to ensure fluid motion against the piping head losses, with no additional useful effect: .

,

f) The collector friction loss is the sum of distributed and lumped losses; these last are due to curves, corners, etc. and are globally evaluated as ∆

2 · 1,0

. The coefficient 2

accounts for a T connection (or a 90° curve) at inlet and one at outlet. Thus, the complete expression of the friction loss—which must be compensated by direct pump work, equivalent to exergy; with a compensation for pump efficiency—is given by: .



ηpump (here assumed 0.6) is the overall pump efficiency (including fluid dynamics and electrical engine efficiency). The final expression of the sum of the exergy losses and destructions is then: ,

,

,

,

,

and the indirect expression of the collector exergy efficiency is: ,

1

.

Exergy efficiency curves of solar collectors In 1974, the National Bureau of Standards published a procedure for testing the thermal performance of solar collectors, that was later modified by ASHRAE in 1977 [11]. The procedure is

E Entropy 20110, 12

2552

aaimed to deetermine thee collector efficiency e c curve (η) vss. X = (Tfi – Ta)/I. It pprovides th he fraction of o s solar radiatiion that is usefully exxtracted byy the workiing fluid flowing in thhe collecto ors (Qu) as a fu function of fluid f inlet teemperature,, environmeental temperrature and collector c dessign parameeters: ,

,

where FR is the collectoor heat remooval factor. w In a simiilar manner, the exergyy efficiencyy (ηex) has been b considdered and aapplied to characterize a r relatively innnovative model m of un-glazed u soolar collecttor, havingg interestingg aesthetic features foor b building inntegration, when com mpared to traditional ones. It is a rectanngular cop pper modulle (2.5 × 0.32 m surface) with 4 ductts (58.5 × 8.5 8 mm crosss section) where w the w working fluiid flows. Thhe r resulting currve is show wn in Figure 8a and com mpared with h the standaard thermal efficiency characteristi c ic o Figure 8bb, under the same workking and dessign conditiions: beam (Ib) and difffuse (Id) rad of diation, winnd v velocity (vwind ( Also thhe influencee of a glasss cover on the perform mance of thhe w ) and colllector tilt (θ). p proposed coollector was evaluated (glazed/un-g ( glazed colleectors). As discuussed in secction 2.2 foor control applications a , the trend of the colllector exerg gy efficienccy c curve vs. X is comppletely diffe ferent from m the ever--decreasing trend of the thermaal efficienccy (Figure 8). The T fact thaat a maximuum efficienccy condition n exists can be explaineed as follow ws: 1) at low w values of the t fluid inlet temperature Tfi, the thermal effficiency reacches its max ximum valuue (Figurre 8b). On the t contraryy, exergy efficiency e (F Figure 8a) is low becaause the flu uid and platte temperatures (verry close eacch other) aree small. A consistent c frraction of thhe original sun radiatioon exergyy is destroyyed becausee of heat degradation th he absorberr plate tempperature lev vel, while thhe loss too the environnment is maarginal (Figgure 9a). 2) at highh fluid tem mperatures Tfi, the exerrgy produced by the collector c is reduced on n account of o large radiation/th r ermal losses to the envvironment (F Figure 8a). The sun—pplate exergy y degradatioon is still large, but not n dominannt in defininng the collecctor perform mance loss (Figure 9a)). 3) at inteermediate values v of tem mperature Tfi, the colllector exerggy efficienccy shows an n optimizinng value (Figure 8a)); this happeens both for the un-glaazed and glazed cases, correspond ding to abouut 60–700 °C for the first one annd 70–80 °C C for the seccond one. Differenttly from the energy effiiciency, the exergy effiiciency is noot optimized at the max ximum valuue o ΔTf = Tfo-Tfi but at of a higher values of innlet temperaature Tfi, correspondin c ng in the specific s casse e examined too a temperaature rise of about 7 °C ° (Figure 9b)). This behavior iss in agreem ment with thhe m model propoosed by Bej ejan [19], who w applies a model to o determinee the collecttor inlet tem mperature Tfi w which optim mizes exerggy efficienncy (un-glazzed collecttor under the t same ffluid inlet temperaturre, e environment tal temperatture and inssulation). Thhe comparisson is show wn in Figure 10. When comparing c e exergy and thermal eff fficiencies of o solar colllectors, anoother interessting point is thheir behaviior with varriable masss flow rate mflow (Figu ure 11). Whhen mflow iss increased,, the thermal e efficiency iss also increaased, becausse of the im mproved con nvection heaat transfer ccoefficient between b platte a flow. Thhe oppositee behavior is found forr exergy effficiency, beccause of thee effect of the and t increaseed f friction lossses and of the reduceed temperaature rise at a high flow wrates, whiich imply large l exerggy c consumption n for fluid circulation c a a lower quality of the and t collectedd heat.

Entropy 2010, 12

253

Figure 8. Exergy and energy characteristic curves of glazed and un-glazed solar (I = 1000 W/m2, Ib = 800 W/m2, Id = 200 W/m2). (a) Exergy efficiency 0,1

ηex = 0,0136301 + 1,80442·(Tfi -Ta)/I - 0,0148826·[(Tfi -Ta) /I ]

0,09

0,7

2

ηex = 0,0130772 + 1,80878·(Tfi -Ta)/I - 0,0191448·[(Tfi -Ta) /I ]

0,08

2

η = 0,602821 - 3,19172·(Tfi -Ta)/I - 0,0145333·[(Tfi -Ta) /I ] 2

η = 0,608003 - 4,74038·(Tfi -Ta)/I - 0,011596·[(Tfi -Ta) /I ]

0,65

0,07

2

I = 1000 W/m 2 Ib = 800 W/m

0,6

Glazed Collector

0,06

Glazed Collector

0,55

0,05

2

Id = 200 W/m

η

η ex

(b) Energy efficiency 0,75

2

θ = 0° vwind = 1 m/s

0,5

0,04

Unglazed Collector

0,45

0,03 0,02

0,4

2

0,01 0 0

I=1000 W/m 2 Ib=800 W/m 2 Id=200 W/m

0,02

0,04

Unglazed Collector

0,35

0,06

0,08 2

0,1

0,12

0,3 0

0,14

(T fi - T a)/I [(K m )/W]

0,01

0,02

0,03

2

0,04

0,05

0,06

(T fi - T a)/I [(K m )/W]

Figure 9. Exergy destruction/loss, useful exergy and temperature rise of solar collectors.

ExDsun-plate

ExLenv

0,02

0,04

0,06

0,08

40

10

Exout

35

8

30 25

6

Δ Tf =Tfo-Tfi

20 15

4

10

2

5 0 0

0,1

0,02

2

0,04

0,06

0,08

0,1

2

(T fi -T a)/I [(K m /W]

(Tfi - Ta)/I [(K m )/W]

Figure 10. Exergy efficiency of solar collector-Comparison between current model and Bejan’s [19]. 0,1 2

0,09

ηex = 0,0130772 + 1,80878·(Tfi -Ta)/I - 0,0191448·[(Tfi -Ta) /I ]

0,08 0,07 0,06

Unglazed Collector

0,05 0,04 0,03 0,02 0,01 0 -0,01 0

Current model Bejan Model

0,02

0,04

0,06

0,08 2

(T fi - T a)/I [(K m )/W]

0,1

0,12

0

ΔTf [C]

Tp

(b) Useful exergy and fluid temperature increase

Exout [W]

130 120 110 100 90 80 70 60 50 40 30

Tp [C]

1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0 0

η ex

Relative Exergy destruction or loss [%]

(a) Exergy destruction/loss and plate temperature

Entropy 2010, 12

254

Figure 11. Energy (η) and exergy (ηex) efficiency of solar collector vs. collector inlet flowrate (n = number of ducts, Wduct = duct section wide). 0,63

0,018 0,016

0,62 η

0,61

0,014

n=4

0,012

η ex

η

Wduct=0,060 m

0,6

0,01 0,59

η ex

0,008 0,58 0,006 0,57 0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,1

m flow[kg/s]

Finally, exergy accounting can be applied to qualify the amount of thermal energy captured by the collector covering a relatively long time period, like months or seasons. It is interesting to notice that the highest amount of exergy is collected in spring months like April and May, whereas in summer and winter worse performance levels are achieved (figure 12). This is attributable to the following reasons: 1) in winter the fluid temperature rise across the collector is modest, consequently the exergy collected is reduced. 2) in summer, in spite of larger temperature rise, the higher environmental temperature (representing the reference state) is responsible for reduced exergy performance. On the whole, the moderate levels of environmental temperatures in spring are responsible for a good exergy performance of solar collector in this season. The effect of the environmental temperature Ta is remarkable for moderate temperature rise of the working fluid (ΔTf), whereas at high ΔTf the influence of Ta on the exergy collected is reduced. For a fixed collector surface area, ΔTf increases with reducing flowrate, resulting in an increase of exergy collected per square meter, as shown in Figure 12b). Moreover, in midsummer months like July, the worst performance is registered at high flowrate, whereas high levels of collected exergy can still be achieved at low flowrates in spring months like May. This suggests that the effect of increasing ΔTf at reduced flowrate prevails over the effect of higher environmental temperatures in summer. On the whole, we can say that environmental temperature plays an appreciable effect on collected exergy when the temperature rise is relatively low, whereas it is of minor importance at relatively high ΔTf. From this point of view, exergy analysis applied to an existing solar collectors field can be regarded as an useful tool to adjust the flow rate according to the different energy demand and seasonal conditions: the guideline being to collect the highest possible amount of exergy. In fact, in cold time periods, when collectors heat losses to the environment are consistent, it may often be useful to reduce flow rate in order to achieve interesting values of ΔTf, rather than working at design flow rate but with extremely modest values of ΔTf (0–2 °C). The indication is further complicated by the addition of a storage system (usually a sensible heat device), where transient behavior must also be considered, and of external heat integration (usually provided by fossil fuels); in this case, the optimal size of the

Entropy 2010, 12

255

storage can be determined with exergy principles, with different results with respect to application of energy/primary resource balances [21]. Figure 12. Daily collected exergy per square meter of collector area. (a) Commercial glazed vs un-glazed collector mflow=0.01 kg/s Tfi=30 °C

5

Glazed Collector Unglazed collector

Dec

Nov

Oct

Jul

Sep

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Month

Aug

0,05

Jan

0

0,0274

Jun

1

0,005 0,01

Apr

2

May

3

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Mar

4

Feb

Collected Exergy [kWh/m2]

Collected Exergy [kWh/m2]

6

(b) Commercial collector: Influence of flowrate

Month

3. Reactive Systems 3.1. Case 4—Fuel Cell/Gas Turbine Integration—Reforming of Methanol The conversion of the chemical exergy of a fuel into electricity implies large irreversibilities, which can be reduced through a careful application of exergy analysis including reactive sub-systems and components. The reference cases here proposed considers Fuel Cell/Gas Turbine power cycle integration. The first case (A) is based on a pressurized Solid Oxide Fuel Cell (SOFC) coupled to a GTCC power cycle (Figure 13), whereas in the second case (B, Figure 14), the SOFC is placed downstream the gas turbine (GT) at atmospheric conditions, and the exhaust of the GT is directed to the SOFC cathode. The GT is a GE10 model fuelled with methanol, which is attractive because of its low reforming temperature (about 300 °C) and good storability, as it is in liquid state at environmental conditions; moreover, it can be produced as a synthetic fuel from a number of natural resources, including coal and biomass. An extensive description of the proposed power cycles is reported in [22]. Here, the discussion is only focused on exergy analysis and the data shown on figures 13 and 14 are referred to optimized working conditions. In Figure 13 and Figure 14, Wel,tot is the overall power plant electric power output, ηtot the overall power plant efficiency, Ua is the oxidizer utilization factor (the ratio between the actual mass of reactive oxidizer and the overall input) and Vcell is the fuel cell potential. Exergy analysis applied to these reactive power cycles is able to assess the influence of SOFC and of the heat exchangers network on the overall power plant efficiency at variable working conditions (i.e., pressure ratio β, Figure 15). Three pressure ratios were taken into account: very low value (β = 6), which optimizes the efficiency at low SOFC size (mfuel,2 = 1 kg/s), β = 10 for SOFC-GTCC-A and β = 12 for SOFC-GTCC-B, the optimizing values at high SOFC size (mfuel,2 = 3 kg/s) and β = 15, the design value of GT10 [22].

Entropy 2010, 12

256

Figure 13. Layout and main parameters for the pressurized SOFC-GTCC-A power cycle.

3,465 [kg/s] 425,7 [K] 65 [bar] 425 [K] 5 [bar]

DEG

384,8 [K] 1,02 [bar]

553,4 [K] 64,35 [bar]

0,5588 [kg/s]

2,906 [kg/s] 323,1 [K]

ECO CH3OH

563,4 [K] 1,041 [bar]

THP 63,71 [bar]

3192 [kW] 679,3 [K] 29,7 [bar]

585,7 [K] 30 [bar]

679,3 [K] 63,07 [bar]

RH

SH

12,01 [bar] 417,3 [K]

427,3 [K] 1,03 [bar]

EVA H2O

TLP

3,001 [kg/s] 298 [K] 12,13 [bar]

ECO H2O

0,1234 [bar] 323,1 [K] Quality= 0,9116

26,62 [kg/s] 495,2 [K] 1,03 [bar]

EVA CH3 OH

49,5 [kg/s] 657,4 [K] 1,051 [bar]

563,4 [K] M g6 = 22,88 [kg/s] 11,89 [bar] 518,1 [K]

1,056 [bar] 583,4 [K] M g2 = 16,37 [kg/s] 666,1 [K] 1,067 [bar]

1,056 [bar] 681,5 [K] M g4 = 23,45 [kg/s]

M g3 = 9,676 [kg/s]

Wel,tot = 44535 [kW] η tot = 0,7461 Ua = 0,4083 Vcell = 0,6818 [V]

33,13 [kg/s]

828,7 [K]

709,3 [K] 1,067 [bar]

9,826 [bar]

-0,00 [kg/s]

10,13 [bar] 9,589 [kg/s] 616,1 [K]

HE2

HE1

654,7 [K] 10,13 [bar]

CC1 9,826 [bar] 799,8 [K]

0,00 [kg/s]

REF

10,65 [kg/s] 9,728 [bar] SPC

42,02 [kg/s]

M fuel2 = 3 [kg/s]

1,062 [kg/s]

9,197 [bar] 6,589 [kg/s]

14,53 [kg/s] 49,5 [kg/s]

anode

SOFC

CC2

CC3

1376 [K] 9,105 [bar]

878,7 [K] 1,1 [bar]

cathode

799,8 [K] 40,96 [kg/s] 9,826 [bar]

DC/AC

1376 [K] 9,197 [bar]

10118 [kW]

31225 [kW] C

GT

4,48 [kg/s] 46,5 [kg/s]

3.2. Exergy Analysis of SOFC-GTCC-A (Pressurized SOFC). It is interesting to observe the trend of the exergy efficiency of each component under the different working conditions (Figure 15b). The less efficient ones are the combustion chambers, the de-aerator and the methanol economizer. Anyway, the last two have a modest influence on the overall power cycle (less than 0.5%, see Figure 15a). Into the Syngas Pre Combustor (SPC), partial combustion of the produced syngas takes place to reach the required anode temperature if the exhaust temperature is not enough (depending on the GT pressure ratio and firing temperature) to achieve the required value of syngas temperature at anode inlet by heat recovery in HE2. It is the less efficient component (exergy efficiency lower than 50%). Also the combustion chambers show relatively low exergy efficiencies (70%), as well as the reformer and the GT compressor (80%). The heat exchangers showing the highest values of exergy destructions are HE1, HE2 and the vaporizers. The accurate choice of matched heat capacities on the two sides of HE2 , which involved adjusting the hot stream flow rate [22], leads to a high exergy efficiency level (90%). Also the heat capacities on the two sides of HE1 are well matched, as it shows rather good efficiency (85%) except at relatively high pressure ratios. At β = 15, the efficiency of HE1 drops to 30%, but the heat transferred in this case is relatively modest, which implies a very reduced contribution to the overall power cycle exergy destruction (0.29%). The choice of using the whole exhaust flow rate to feed the vaporizer of

Entropy 2010, 12

257

the bottoming cycle improved the matching of gas/steam heat capacities [22], which lead to high efficiency level (about 90%) of the vaporizer (EVAH2O). Low efficiency level is achieved into the methanol economizer (ECOCH3OH), due to the high difference between exhausts and fuel and not high matching of heat capacities. Figure 14. Layout and main parameters for the atmospheric SOFC-GTCC-B power cycle. Mfuel2 = 3 [kg/s] Mfuel1 = 0,2226 [kg/s]

753,2 [K]

Mg1 =36,71 [kg/s]

12,3 [bar] 753,2 [K]

63,07 [bar]

1381 [K] 1,128 [bar]

RHb SHb

63,07 [bar] 753,2 [K]

Wel,ST = 5985 [kW] HPT

HE3 714,3 [K] 1,045 [bar]

63,71 [bar] 552,7 [K]

13,87 [bar] 24,44 [kg/s] 568,7 [K] 1,035 [bar] 25,29 [kg/s]

424,5 [K] 14,01 [bar]

EVA H2O 64,35 [bar] 554 [K]

ECO H2O

455,7 [K] 1,025 [bar]

848,6 [K] 46,72 [kg/s]

638,6 [K] 0,7854 [kg/s]

744,7 [K] 1,061 [bar]

HE1 694,7 [K] 12,16 [bar] 42,22 [kg/s]

389,1 [K]

46,72 [kg/s] 836,5 [K] 1,23 [bar]

HE4 694,7 [K] 12,16 [bar]

1288 [K] 11,79 [bar]

CC1

1376 [K] 11,67 [bar]

Wel,GT = 6964 [kW]

1,014 [bar]

C

CH3OH

1,128 [bar] 1381 [K] 49,72 [kg/s]

DC/AC

DEG

425,7 [K] 5,454 [kg/s] 65 [bar]

CC2

Wel,FC = 32737 [kW]

836,5 [K] 46,72 [kg/s] 1,23 [bar]

5 [bar]

anode

cathode

1368 [K] 1,094 [bar]

323,1 [K] 4,668 [kg/s] XBP,out = 0,9993

4,682 [kg/s]

SOFC

1,193 [bar]

12,43 [bar] 552,7 [K]

434,5 [K] 1,025 [bar]

ECO CH3OH

525,4 [K] 7,682 [kg/s] 1,23 [bar] REF

7,682 [kg/s] 1,193 [bar] 923 [K]

LPT

RHa SHa

EVA CH3OH

Mg2 =13,01 [kg/s]

HE2

12,3 [bar] 753,2 [K]

523,6 [K]

1,094 [bar] 983 [K]

V cell = 0,6817 [V] Ua = 0,3885 η tot = 0,712

GT

4,282 [kg/s] 46,5 [kg/s]

With increasing SOFC size (which is reflected by the fuel input mfuel,2), the stack exergy loss, and the reformer and combustion chamber CC2 exergy destructions increase, whereas the compressor and expander ones remain practically unchanged (Figure 15c). The combustor CC3 is still inactive, whereas CC1 is only activated at β = 15, but the power output in this case is lower than in the case with low SOFC size; consequently the relative exergy destruction is much reduced. The Pre-combustor relative exergy destruction (SPC) is higher than 2%, as the syngas flow rate—which must be preheated—is increased. The exergy efficiency of the SPC is still very low (50%). The exergy efficiency of power plant components like compressor, expanders, is at the same level of the case with mfuel,2 = 1 kg/s, which reveals a modest influence of SOFC size on their performance (Figure 15d). On the whole, the overall performance of the power plant is improved increasing the SOFC size (the SOFC is a very exergy-efficient component). 3.3. Exergy Analysis of SOFC-GTCC-B (Atmospheric SOFC) The relative exergy destructions and the exergy efficiency of SOFC-GTCC-B components (atmospheric SOFC) at small and large SOFC size (mfuel,2 = 1 and 3 kg/s respectively) are shown in Figure 16. At low SOFC size, the highest exergy destruction is located at the GT combustion chamber CC1. Like in the previous case A, at low SOFC size the temperature required at the cathode inlet is increased, thus heat exchanger HE3 is activated and hot exhausts coming from CC2 get into HE4 with

Entropy 2010, 12

258

reduced temperature values, thus the GT heat recuperation is reduced as well. In this way, a higher amount of fuel is required and consequently CC1 shows a larger exergy destruction. Compressor, reformer, GT expander, and SOFC have a significant weight in the overall power plant exergy balance, even though the last ones have a relatively high efficiency (93–94%, Figures 16b, 16d). In the heat exchangers network, HE3 and HE4 have the highest influence on overall exergy destructions, in spite of their high efficiency (>90%). Figure 15. Relative exergy destruction and exergy efficiency of the SOFC-GTCC-A power cycle components (pressurized SOFC). (a) Relative exergy destruction, low SOFC size. mfuel,2=1 kg/s Pressurised SOFC

β=6

90

β=10

80

β=15

70

REFORMER

SOFC

STACK

SH H2O

RH H2O

Reformer

SPC

Mix. Mg2,3,4

HE1

HE2

Expander

Ev. H2O

Ev. CH3OH

Eco. H2O

Eco. CH3OH

Deaerator

CC3

Comp.

CC1

0

(d) Exergy efficiency of components, high SOFC size [%] 100

β=6

β=10

mfuel,2=3 kg/s

β=15

90

SOFC

REFORMER

Expander

80 70 50 30

SPC

STACK

SOFC

SH H2O

RH H2O

REFORMER

SPC

Mix Mg2,3,4

HE2

HE1

GT

Evap. CH3OH

Evap. H2O

Eco. CH3OH

Eco. H2O

CC2

CC3

0

Deaerator

10 CC1

STACK

SH H2O

20

RH H2O

HE2 Mixing Mg2,3,4

40

HE1

Exhaust mg5

10

CC2

SOFC STACK

SH H2O

20

RH H2O

SPC

HE2 Mixing Mg2,3,4

Expander HE1

30

60

Exhaust mg6

Evap. CH3OH

mfuel,2=1 kg/s

β=15

40

Compressor

0

CC3

1

CC1

2

Condenser

3

Econom. CH3OH

4

Deaerator Econom. H2O

CC2

5

Compressor

6

Evaporator

7

mfuel,2=3 kg/s Pressurised SOFC

Electric Conversion

β=6 β=10 β=15

β=10

50

(c) Relative exergy destruction, high SOFC size 8 [%]

β=6

60

Exhaust mg6

Electric Conversion Evaporator Evap. CH3OH Exhaust mg5

Econom. CH3OH

Deaerator

Econom. H2O

Compressor

Condenser

CC1

(%) 100

CC2 CC3

[%] 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

(b) Exergy efficiency of components, low SOFC size.

Like in the case of pressurized SOFC, increasing the SOFC size leads to an increase in SOFC and reformer relative exergy destructions (Figures 16a, 16c), with contributions at the same levels as those found in case A with a pressurized SOFC. The exergy destruction in CC1 is strongly reduced because the GT cycle heat recovery level through HE4 is consistently increased. The exergy destruction in HE2 increases due to the higher flowrate of reformed gas. Also HE1 (when activated, β = 6) provides an appreciable contribution of 2% to the overall exergy destruction. Generally, for higher SOFC flow rates, the power cycle efficiency is improved, mainly due to the higher weight of reformer and SOFC, which are the most efficient components (Figures 16b, 16d). The exergy efficiency of HE2 is lower compared to the cycle with pressurized SOFC (76% vs. 92%), due to the much larger average temperature difference between the hot and cold streams (400 °C vs. 50 °C).

Entropy 2010, 12

259

Figure 16. Relative exergy destructions and exergy efficiency of the SOFC-GTCC-B power cycle components (Atmospheric SOFC). (a) Relative exergy destructions, low SOFC size

40 30 20

STACK

SHb/RHb

SOFC

SHa/RHa

REFORMER

Mix. Mg4,5

HE3

HE4

HE1

HE2

GT

Evap. CH3OH

Evap. H2O

Eco. H2O

Eco. CH3OH

Deaerator

CC2

CC1 [%] 100

SOFC (stack)

REFORMER

(d) Exergy efficiency of components, high SOFC size β=6

β=12

mfuel,2=3 kg/s

β=15

90 80 70 60 50

20

STACK

SHb/RHb

SHa/RHa

SOFC

REFORMER

Mix. Mg4,5

HE3

HE4

HE2

HE1

Expander

Eva. H2O

Eva. CH3OH

Eco. CH3OH

Eco. H2O

CC1

0

Comp.

10 CC2

STACK

30 SHb/RH b H2O

SHa/RHa H2O

HE3

HE4 Mixing Mg4,5

40

HE1 HE2

Exhaust mg5

β=6 β=12 β=15

0

Compressor

10

STACK

SHb/RHb H2O SOFC (stack)

REFORMER SHa/RHa H2O

HE4 Mixing Mg4,5

HE1

HE2 HE3

Exhaust mg5

50

Expander

Evap. CH3OH Exhaust mg4

mfuel,2=1 kg/s

70

Deaerator

0

Electric Conversion Evap. H2O

Econom. CH3OH

Compressor Deaerator

1

Econom. H2O

2

CC1

3

CC2

4

Condenser

5

β=15

60

mfuel,2=3 kg/s, Atmospheric SOFC

6

β=12

80

β=15

[%]

7

β=6

90

β=12

(c) Relative exergy destructions, high SOFC size 8

(b) Exergy efficiency of components, low SOFC size (%) 100

β=6

Expander

Evap. CH3OH Exhaust mg4

Electric Conversion Evap. H2O

Deaerator

Econom. H2O Econom. CH3OH

Compressor Condenser

CC1

mfuel,2=1 kg/s Atmospheric SOFC

CC2

[%] 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

4. Conclusions Several cases of possible improvement of energy conversion/utilization systems through exergy analysis have been presented and discussed. The selected cases range from conventional power plants (with application of optimization tools), to renewable energy systems (solar energy, with attention to control law for solar thermal conversion; and solar collectors design and operation); finally, more complicated applications involving reactive systems–using methanol and an hybrid GT/SOFC chemically recuperated cycle-have been presented. The purpose of this paper—which presents mostly un-published material from a long time span of the Authors’ research—is to demonstrate the potential of exergy analysis applied to energy conversion/utilization systems. The use of the exergy method is much more widespread in the scientific community than 20 or 30 years ago, and a solid scientific background has been developed, as confirmed by the existence of several reference textbooks [1–4,18]; however, the potential of exergy analysis has not yet been completely demonstrated and the Authors hope that this paper can represent a small contribution to this end.

Entropy 2010, 12

260

References 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21.

Bejan, A.; Tsatsaronis, G.; Moran, M. Thermal Design and Optimization; Wiley Interscience: New York, NY, USA, 1996. Kotas T.J. The Exergy Method of Thermal Plant Analysis; Krieger: New York, NY, USA, 1995. Szargut, J.; Morris, D.R.; Stewart, F.R. Exergy Analysis of Thermal, Chemical and Metallurgical Processes; Hemisphere: New York, NY, USA, 1988. Moran, M. Availability Analysis: A Guide to Efficient Energy Usage; Prentice-Hall: Upper Saddle River, NJ, USA, 1982. Ahern, J.E. The Exergy Method of Energy System Analysis; Wiley: New York, NY, USA, 1980. Kotas, T.J. The Exergy Method of Thermal Plant Analysis, Reprint ed.; Krieger: Malabar, FL, USA, 1995. F-Chart Software. Available online: http://www.fchart.com/ees/ees.shtml (accessed on December 31, 2009). Odeh, S.D. Unified model of solar thermal electric generation systems. Renewable Energy 2003, 28, 755–767. Mills, D. Advances in solar thermal electricity technology. Sol. Energy 2004, 76, 19–31. Camacho, E.; Berenguel, M.; Rubio, F.R.; Advanced Control of Solar Plants; Springer-Verlag: London, UK, 1997. Duffie, J.A.; Beckman, W.A. Solar Energy Thermal Processes; Wiley: New York, NY, USA, 1984. Therminol. Heat Transfer Fluids by Solutia. Available online: http://www.therminol.com (accessed on 31 December, 2009). Manfrida, G.; Kawambwa, S. A two-phase solar collector powering a rankine organic cycle. Presented at World Renewable Energy Congress, Reading, UK, September 1990. ARCHIMEDE—ENEA Grande Progetto Solare Termodinamico. Available online: http://www.enea.it/com/solar/index.html (accessed on 31 December, 2009). Valenzuela, M.; Zarza, E.; Berenguel, M.; Camacho, E.F. Control concepts for direct steam generation in parabolic troughs. Sol. Energy 2005, 78, 301–311. Manfrida, G. The choice of the optimal working point for solar collectors. Sol. Energy 1985, 34, 6. Manfrida, G.; Kawambwa, S. Exergy control for a flat-plate collector/Rankine cycle solar power system. J. Sol. Energy Eng. 1991, 113, 89–93. Schuster, A.; Karellas, S; Kakaras, E.; Spliethoff, H. Energetic and economic investigation of Organic Rankine Cycle applications. Appl. Therm. Eng. 2009, 29, 8–9, 1809–1817. Bejan, A. Entropy Generation Through Heat and Fluid Flow; Wiley: New York, NY, USA, 1982. Farahat, S.; Sarhaddi, F.; Ajam, F. Exergetic optimization of flat plate solar collector. Renewable Energy 2008, 34, 1169–1174. Baldini, A.; Manfrida, G.; Tempesti, D. Model of a solar collector/storage system for industrial thermal applications. In ECOS Conference, Krakow, Poland, June 2008.

Entropy 2010, 12

261

22. Fiaschi, D.; Manfrida, G.; Anselmi, S. Performance analysis and comparison of hybrid SOFC-GT cycles fuelled with methanol. In ASME paper IGTI Turbo GT2008-51367, Berlin, Germany, June 2008. © 2010 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).