Technical Catalogue HMI

54 downloads 339 Views 7MB Size Report
The products section of the MITSUBISHI home site includes various documentations ... Texts, figures and diagrams shown in this product catalogue are intended ...
MITSUBISHI ELECTRIC HMI Human Machine Interface

GOT, MAC

Technical Catalogue

2004

New Items in this Catalogue

ts New Produc 04/2004

왘 Software MX4 SCADA’s exceptional flexibility maximizes your productivity by allowing optimal system architecture in the way that best suits you giving you access to powerful, dynamic features for both centralised and distributed processing.

Further Publications within the PLC Range Technical catalogues System Q, AnU/QnA, AnS/QnAS, FX family

Technical Catalogues

Product catalogues for programmable logic controllers and accessories for the MELSEC series

Technical catalogue Networks Product catalogue for Master and Slave modules as well as accessories for the use of programmable logic controllers in open networks and MELSEC networks

Additional Services You will find current information on updates, alterations, new items, and technical support on MITSUBISHI ELECTRIC's web pages (www.mitsubishi-automation.com). The products section of the MITSUBISHI home site includes various documentations of the whole product range by MITSUBISHI ELECTRIC as well as the current version of this catalogue on hand. All manuals and catalogues can be downloaded. The content is updated daily and to date is provided in German and English.

About this product catalogue Due to the constantly growing product range, technical alteration, and new or changed characteristical features, this catalogue is updated frequently. Texts, figures and diagrams shown in this product catalogue are intended exclusively for explanation and assistance in planning and ordering the operator terminals of the HMI series and the associated accessories. Only the manuals supplied with the units are relevant for installation, commissioning and handling of the units and the accessories. The information given in these documentations must be read before installation and commissioning of the units or software. Should questions arise with regard to the planning of modules described in this product catalogue, do not hesitate to contact the german branch of the MITSUBISHI ELECTRIC EUROPE B.V. in Ratingen or one of its distributors (see cover page). © MITSUBISHI ELECTRIC EUROPE B.V. 04/2004 (10th edition)

2

HMI

MITSUBISHI ELECTRIC

CONTENTS

HMI BASICS

INTRODUCTION AND CONFIGURATION

웇 Introduction of the HMI control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 웇 HMI and networks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

GOT SERIES CONTROL TERMINALS 웇 웇 웇 웇

System description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Text display units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Panel description and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Communications modules und adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

MAC E SERIES OPERATOR TERMINALS

웇 System description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 웇 Panel description and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 웇 Industrial PC’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

ACCESSORIES 웇 웇 웇 웇 웇 웇

Backlights, protective film sheets, keyboard extension. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 PROFIBUS/DP adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Profibus connector, interface boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Storage media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Interface converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

DIMENSIONS

웇 GOT series control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 웇 MAC E series control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 웇 Industrial PC’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

PROGRAMMING SOFTWARE 웇 Visualisation software for GOT and FX-DU control units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 웇 Programming software for GOT series control units GT-Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 웇 Programming software for MAC E series control units E-Designer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 웇 Programming software for MAC E series control units E-View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 웇 Software-based HMI solution GT SoftGOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 웇 Process visualisation software MX4 SCADA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

APPENDIX 웇 Order form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 웇 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

MITSUBISHI ELECTRIC

HMI

3

INTRODUCTION AND CONFIGURATION

BASICS

HMI Control Units for Human-Machine Communication The interface between human and technology Users of today’s factory automation systems want more and clearer information on the control systems of their plant and machinery. HMI control terminals and process visualisation software enable an informative dialogue between operator and machine, making them the ideal complement to the MELSEC PLC systems. HMI control units make factory system functions transparent, enabling the operator to monitor and edit process data quickly and easily. You can choose between HMI control units with text and graphical displays. Fully programmable function keys and displays make the units even more user-friendly. The units can be programmed and configured with a PC running the intuitive Windows-based programming software package. HMI units can be installed directly on your machines and require nearly no additional modules for connection to the PLC. They provide direct access to all information and process data, with text or graphical displays. An IP65 rating (and higher) ensures that the HMIs will always perform reliably, even under the toughest conditions.

Features 앬 Simple installation and user-friendly operation 앬 Broad range of applications 앬 Clear text and graphics process displays

앬 Report generation for quality control

and process data exchange

앬 Precise, informative messages and

instructions in error situations

TERMINAL GRAPHIC OPERATION

M CE A

E X T

POWER

MITSUBISHI

-. 0

POWER

NUM

F1

F2

F3

7

8

1

6

F4

3

2

4

5

9

Specifications

A985GOT

A975GOT

A970GOT

A950GOT A953GOT

F940WGOT

F940GOT

F940/943GOT F930GOT Handy-GOT

F930GOT

F920GOT

Display unit

TFT, 256-col.

TFT, 256-col.

SBD: STN, SBA: STN, 8-col. 8-col. LBA: EL, 2-col. LBD: STN, mono

TFT, 256-col.

STN, 8-col./mono backlit

STN, 8-col./mono backlit

STN, 2-col.

STN, 2-col. backlit

STN,2-col./ white/red backlit

Display format (W x H) / mm character height Resolution; characters x lines (pixles) Applicable PLC Applicable third party manufact.

246 x 184.5

211 x 158

211 x 158

115 x 86

155.5 x 87.8

115 x 86

115 x 86

117 x 42

117 x 42

60 x 30

200 x 75 160 x 60 (800 x 600) (640 x 480) All MELSEC PLC systems All major PLC manufacturers

160 x 60 (640 x 480)

40 x 15 (320 x 240)

60 x 14 (horiz.) 40 x 15 29 x 30 (vert.) (320 x 240)

40 x 15 (320 x 240)

15 x 5 (240 x 80)

30 x 5 (240 x 80)

16 x 4 (128 x 64)

Printer interface

Integrated

Integrated

Integrated

RS232C

RS232C

RS232C

RS232C

RS232C

Memory type External I/O connectors Real-time clock

Flash-RAM 8 Via PLC

Flash-RAM 8 Via PLC

Flash-RAM 8 Via PLC

Flash-RAM 2 Via PLC

Flash-RAM 3 Integrated

Flash-RAM 2 Integrated

Flash-RAM 2 Integrated

Flash-RAM 2 Integrated

Keyboard

Touch-panel

Touch-panel

Touch-panel

Touch-panel

Function keys

Up to 1900 touch-keys 1 (POWER) 2.35 kg

Up to 1200 touch-keys 1 (POWER) 1.7 kg

Up to 1200 touch-keys 1 (POWER) 1.78 kg

Up to 3000 touch-keys 1 (POWER) 1.0 kg

LED indicators Weight

4

HMI

— RS232C

Flash-ROM 2 Integrated Touch-panel Touch-panel Touch-panel Touch-panel Membrane/ Touch-panel Max. 50 touch- Max. 50 touch- Max. 50 touch- Max. 50 touch- 8/max. 50 touchkeys/screen keys/screen keys/screen keys/screen keys/screen 1 (POWER) 1 (POWER) 6 — 8 (green) 0.79 kg 1.0 kg 0.79 kg 0.3 kg 0.6 kg

RS232C Flash-ROM 2 Integrated Membrane 6 — 0.3 kg

MITSUBISHI ELECTRIC

INTRODUCTION AND CONFIGURATION

ETHERNET

MELSECNET

P R O F

I

PROCESS FIELD BUS

B U S

Supported Networks 앬 Modem Links Enables connections over larger distances. 앬 Ethernet and MAC-Net For connection of multiple MAC E control units to the PLC system in installations extending over larger areas. 앬 MELSECNET Enables high-speed access (up to 10 Mbaud) to the PLC from multiple locations via the A900GOT or the MAC E900T/E900VT/ E910T. 앬 Dual Driver support The MAC E series control units can be used e.g. as an interface between 2 systems. This feature is supported from O/S version 6 (not for MAC E50)

앬 PROFIBUS/DP

MAC E series control units can be connected as slaves in systems using the open field bus protocol. 앬 Multidrop-Net Enables programming and data logging from a central location using a PC; the individual stations operate autonomously and independently of one another. 앬 No-Protocoll-Link Enables connection of barcode readers and other serial devices to the PLC via the MAC E series control units. 앬 A-BUS/Q-BUS Direct connection of the A900GOT and MAC E900T/900VT/910T (A-BUS only) to the PLC’s expansion port for fast communications.

FX-10DU-E FX-10DM-E MAC E50 MAC E100 MAC E150 MAC E200 MAC E300

HMI and networks Network support, communication between devices and data exchange are all standard features in today’s factory automation systems. The HMI control units and process visualisation software provide full support for the commonest standard networks. The control units are normally connected to the PLC’s RS422 port, which provides a 1:1 link. In MELSECNET the control units can be configured as slaves. If you require a standard open network you can choose between PROFIBUS/DP, CC-Link and Ethernet TCP/IP. A unique option is the 1:n link provided by MAC-Net and the fast Ethernet (up to 100Mbits) for MAC E series, a configuration which enables several MAC E units to access the PLC simultaneously. Data communications over longer distances via modem are also possible – this means you can monitor and edit your configuration, programs and data from the comfort of your desk. Interfaces 앬 RS422 앬 RS232C 앬 RS485/RS422 (optional) 앬 MELSEC A-BUS (optional) 앬 MELSEC Q-BUS (optional) 앬 PROFIBUS/DP (optional) 앬 Ethernet TP (coaxial or twisted pair, optional) 앬 CC-Link (optional)

MAC E600

MAC E610/ MAC E615

MAC E700

MAC E710

MAC E900T MAC E900VT

MAC E910T

LCD

LCD

LCD, mono, backlit

LCD, momo, backlit

LCD, mono, LCD backlit

LCD, mono, backlit

LCD, mono, backlit

LCD, 16 graysc./ 256 colours, backlit

LCD, 256colours, backlit

LCD, 256colours, backlit

TFT/ TFT/ 256 colours, 256 colours, backlit backlit

TFT/ 256 colours, backlit

8

8

5

5

5

132 x 38

132 x 38

115 x 86

120 x 90

120 x 90

214 x 161

214 x 161

214 x 161

16 x 2

16 x 2

FX family —

FX family —





EEPROM — Via PLC

EEPROM — Via PLC

20 x 4 / 40 x 8 (240 x 64) All MELSEC PLC systems (MAC E50: only MELSEC FX, AnS, AnU) All major PLC manufacturers RS232C, — RS232C, RS232C, — RS422 RS422 RS422 Flash-RAM Flash-RAM Flash-RAM Flash-RAM Flash-RAM 2 2 2 2 2 — Integrated Integrated Integrated Integrated

Membrane Membrane

16 x 2

20 x 2

20 x 2

5 20 x 4

Membrane Membrane Membrane Membrane Membrane





4 soft keys 4

4 soft keys 5

— 0.2 kg

— 0.15 kg

— 0.2 kg

— 0.5 kg

— 0.25 kg

MITSUBISHI ELECTRIC

5 (2-col.) 0.7 kg

8/max. 128 (opt.) 16 (2-col.) 1.5 kg

20 x 8 / 40 x 16 320 x 240 (240 x 128)

40 x 30 40 x 30 (320 x 240) (320 x 240)

80 x 60 (640 x 480)

80 x 60 (640 x 480)

80 x 60 (640 x 480)

RS232C, RS422 Flash-RAM 2 Integrated

RS232C, RS422 Flash-RAM 2 Integrated

RS232C, RS422 Flash-RAM 2 Integrated

RS232C, RS422 Flash-RAM 2 Integrated

RS232C, RS422 Flash-RAM 2 Integrated

RS232C, RS422 Flash-RAM 2 Integrated

RS232C, RS422 Flash-RAM 2 Integrated

Membrane

Touch-panel

Membrane Touch-panel

Membrane

Membrane

Touch-panel

16/max. 128 (opt.) 16 (2-col.) 1.6 kg

touch-keys/ max. 128 (opt.) 1 (POWER) 1.7 kg

16/max. 128 (opt.) 14 (2-col.) 1.7 kg

22 /max. 128 (opt.) 20 (2-col.) 3.5 kg

22 + 28 / max. 128 (opt.) 20 + 28 (1-col.) 3.5 kg

touch-keys / max. 128 (opt.) — 3.5 kg

8/touch-keys/ max. 128 (opt.) 8 (2-col.) 1.7 kg

HMI

5

BASICS

PLC, HMI and different Networks in Cooperation

OPERATOR TERMINALS GOT

BASICS

A900GOT Series Operator Terminals Complex processes displayed simply The graphic operator terminals of the A900GOT series represent the top products by MITSUBISHI ELECTRIC. They provide a high-resolution touchsensitive screen. State changes and user inputs can be entered easily. A vast number of indicating instruments like indicators, pressure gauges, analog and digital

Extension slot for memory card

measuring devices, etc. can be replaced by corresponding graphical objects. Lots of ready-to-use practical objects are included in the MS Windows® compatible programming software and reduce program development time.

Moreover, the A900GOT is capable of displaying texts with up to 26,000 international characters. With the GOT the user accesses all special function modules in order to test individual parts of the plant. The PLC programs can be monitored graphically (ladder diagram).

Touch-sensitive screen

Network interface

TERMINAL GRAPHIC OPERATION

M CE A

M-CARD ACCESS ON RESET

E X T

POWER

MITSUBISHI MEMORY CASSETTE A9GT-FNB4M

MODEL

4Mbytes

DATE

INPUT 100-240VAC

~

MITSUBISHI

RUN OUTPUT (LG)

(FG)

L

L

12/24VDC 0,1A + -

RS-232-C

9811A

MITSUBISHI ELECTRIC

CORPORATION

MADE IN JAPAN

BD992C032H12

PARALLEL

Power indicator Speaker connection

RS232C interface

Interface for future expansions

Dust cover – Behind the dust cover is the mounting place for the memory cartridge.

M-CARD ACCESS

M-CARD ACCESS

ON

ON RESET

RESET

MITSUBISHI MEMORY CASSETTE A9GT-FNB4M

MODEL

4Mbytes

DATE

9811A

CORPORATION MITSUBISHI ELECTRIC BD992C032H12 MADE IN JAPAN

MITSUBISHI A BUS INTERFACE UNIT A9GT-BUS2S

MODEL

MITSUBISHI MEMORY CASSETTE MODEL A9GT-FNB4M INPUT 100-240VAC

~

RUN OUTPUT (LG)

(FG)

L

L

12/24VDC 0,1A + -

RS-232-C

Extension No. Switch 1~7 “EXTENSION NO.” 8,9,0 “Use prohibited”

4Mbytes

PARALLEL

DATE

9811A

CORPORATION MITSUBISHI ELECTRIC BD992C032H12 MADE IN JAPAN

INPUT 100-240VAC

~

RUN OUTPUT (LG)

(FG)

L

L

12/24VDC 0,1A + -

RS-232-C

PARALLEL II // OO 0~7 8,9

Slot Switch I / O SLOT “Use prohibited”

DATE

9806A

CORPORATION MITSUBISHI ELECTRIC BD992C032H08 MADE IN JAPAN

REAR SIDE IN OUT DISPLAY SIDE

Insert the memory cartridge Power supply terminal bar – The power supply unit is already integrated

6

HMI

Parallel printer interface

Insert the communications module

MITSUBISHI ELECTRIC

OPERATOR TERMINALS GOT

Provided Connections for A900GOT

GRAPHIC OPERATION

BASICS

A900GOT TERMINAL

M CE A

E X T

POWER

MITSUBISHI

Q06HCPU

POWER

5 6 7 8

BASE UNIT MODEL Q38B SERIAL 0205020E

9 A B PULL

C D

USB

USB

2

E F

0 1 2 3 4 5 6 7 8 9

4

L 5

L

6

L 7

L

8

L 9

L

A

L L

B C

L L

D E

L L

F COM

PULL

RUN T.PASS SD ERR.

QC30R2

MNG D.LINK RD L ERR.

0 1 2 3 4 5 6 7 8 9

X1

V+ C VH 2

I+

SLD V+ C VH 3

I+

SLD V+ C VH 4

I+

0 1 2 3 4 5 6 7 8 9

MODE

AC30/300R4-25P

SLD A.G.

NC (FG)

COM

RS-232

RS-232

24VDC 4mA

FX-232CAB1

STATION NO. X10 I+

SLD

3

L

3

QJ71BR11 RUN

C VH 1

1

L

2

ERROR V+

L L

1

4

PULL

01234567 89ABCDEF FUSE

01234567 89ABCDEF

MODE RUN ERR. USER BAT. BOOT

Q64AD

QY80

QX80

Q06HCPU

MODE RUN ERR. USER BAT. BOOT

Q61P-A2

12VDC 24VDC 0.5A

A/D 0~±10V 0~20mA

QJ71BR11

MITSUBISHI

System Q FX9GT-CAB0

100-240 VAC

S/S L

N

X1 X0

MITSUBISHI

X3 X2

X5 X4

X6

X15 X7 X11 X13 X10 X12 X14

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IN

POWER RUN ERROR

FX1N-24MR OUT

0 1 2 3 4 5 6 7 10 11 Y6 Y10 Y5 Y3 Y2 Y1 Y11 Y0 0V COM4 Y7 COM2 COM3 Y4 24+ COM0 COM1

MELSEC AnS/QnAS series

24MR -ES/UL

Personal Computer

MELSEC FX family

General Operating Conditions Item

Display

Main body

Ambient temperature in operation

0 – +40 °C

0 – +55 °C

Ambient relative humidity

10 – 90 % (non-condensing)

Storage temperature

-20 – +60 °C

Noise durability

1000 Vpp tested by noise generator; 1 µs at 30 – 100 Hz

Dielectric withstand voltage

1500 V AC, > 1 min / 500 V DC, > 1 min

Shock resistance

15 G (3 times each in 3 directions)

Vibration resistance

1 G: resistant to vibrations from 57 – 150 Hz for 80 min. along all 3 axes

Altitude

Max. 2000 m above NN

Over-voltage category

Max. 11

Pollution level

Max. 2

EMC

89 / 336 / EEC and 93 / 68 / EEC

Environment

Avoid environments containing aggressive gases

Cooling

Self-cooling

Certifications

UL / CSA / CE

MITSUBISHI ELECTRIC

HMI

7

OPERATOR TERMINALS GOT

BASICS

Operator Terminals F900GOT The F900GOT Series - A Window through to Your MELSEC PLC Would you like to cut your costs and improve efficiency? You can with the F900GOT series control units. The graphic display configuration on the touch screen is variable, giving the operating staff quick, clear and easily-comprehensible access to information on machine functions. The graphical control unit F900GOT combines particularly easy operation with maximum functionality and modest space requirements.

In addition to standard display and diagnostics functions this unit also supports fully-programmable graphical images and ”touch-keys”. You can store up to 500 user-defined screens, up to three of which can be displayed simultaneously and overlapping on the backlit LC display. The units feature an integrated real-time clock, password access control and alarm and recipe handling.

Data communication with the MELSEC FX-, MELSEC AnS/QnAS or MELSEC AnU/QnAseries is performed via the RS422 port as standard. A printer can be connected to the integrated RS232 port. The control unit is programmed with the FX-PCS/DU-WIN-E or GT-Works software package running on a PC under MS Windows®. Programs can be stored either in the control unit’s integrated, battery-powered RAM or in plug-in EPROM modules.

F940GOT

F930GOT

Touch screen

POWER

Power indicator

RS232C interface

RS232C

RS422 PROGRAMMABLE

CAUTION

Lithium

COM1 RS232C

Backup battery PROGRAMMABLE

CONTROLLER MITSUBISHI MODEL F940GOT-SWD TERMINAL

CONTROLLER MITSUBISHI MODEL F930GOT-BWD GRAPHIC OPERATION TERMINAL

. 11 SERIAL NO. 970340 V.1 ION MITSUBISHI ELECTRIC CORPORAT

GRAPHIC OPERATION

. 11 SERIAL NO. 912370 V.1 ION MITSUBISHI ELECTRIC CORPORAT

EXP-I/F

COM0 RS422 CN-OP

CAUTION

Extension slots for communication modules Power supply terminal bar*

RS422 interface *The power supply unit is already integrated

8

HMI

MITSUBISHI ELECTRIC

OPERATOR TERMINALS GOT

BASICS

Provided Connections of F900GOT Units to a MELSEC PLC System

F940GOT

POWER

FX-232-CAB1

FX-50DU-CAB0/EN

QC30R2

FX-40DU-CAB/EN

Q06HCPU

POWER

5 6 7 8

BASE UNIT MODEL Q38B SERIAL 0205020E

9 A B PULL

C D

USB

USB

2

E

0 1 2 3 4 5 6 7 8 9

F

4

L 5

L

6

L 7

L

8

L 9

L

A

L L

B C

L L

D E

L L

F COM

PULL

RUN T.PASS SD ERR.

MNG D.LINK RD L ERR. 100-240 VAC

STATION NO. X10

0 1 2 3 4 5 6 7 8 9

S/S L

N

X1 X0

I+

SLD

3

L

3

QJ71BR11 RUN

C VH 1

1

L L

2

ERROR V+

L

1

4

PULL

01234567 89ABCDEF FUSE

01234567 89ABCDEF

MODE RUN ERR. USER BAT. BOOT

Q64AD

QY80

QX80

Q06HCPU

MODE RUN ERR. USER BAT. BOOT

Q61P-A2

I+

SLD V+ C VH 3

I+

SLD V+ C VH 4

MITSUBISHI

X1

V+ C VH 2

I+

0 1 2 3 4 5 6 7 8 9

X3 X2

X5 X4

X6

X15 X7 X11 X13 X10 X12 X14

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IN

POWER RUN ERROR

MODE

FX1N-24MR OUT

0 1 2 3 4 5 6 7 10 11 Y6 Y10 Y5 Y3 Y2 Y1 Y11 Y0 0V COM4 Y7 COM2 COM3 Y4 24+ COM0 COM1

24MR -ES/UL

SLD A.G.

NC (FG)

COM

RS-232

RS-232

24VDC 4mA

12VDC 24VDC 0.5A

A/D 0~±10V 0~20mA

QJ71BR11

MITSUBISHI

MELSEC System Q

MELSEC AnS/QnAS series

MELSEC FX family

General Operating Conditions Item

F900GOT

Ambient temperature in operation

0 – +50 °C

Ambient relative humidity

35 – 85 %

Storage temperature

-20 – +70 °C

Noise durability

1000 Vpp tested by noise generator; 1 µs at 30 – 100 Hz

Dielectric withstand voltage

1500 V AV, > 1 min.

Shock resistance

10 G (3 times each in 3 directions)

Vibration resistance

2 G: resistant to vibrations from 10 – 55 Hz for 2 h. along all 3 axes; 0.5 G when mounted on a DIN-rail

Insulation resistance

> 5 MΩ (500 V DC)

Grounding

Class 3 (100 Ω)

Environment

Avoid environments containing aggressive gases

Cooling

Self-cooling

Certifications

UL / CSA / CE

MITSUBISHI ELECTRIC

HMI

9

OPERATOR TERMINALS GOT

왎 Text Control Panels FX-10 D첸-E Text control panels FX-10 DM-E / FX-10 DU-E BASICS

FX-10 DU-E

CLR

ENT

FNC

FX-10 DM-E

Specifications

FX-10 DM-E

Applicable PLC

MELSEC FX

Power supply

V DC 5 ± 5 % (via PLC)

The text control panels FX-10 DM-E and FX-10 DU-E make the funtions of the controlled system transparent to the user. They provide a key-oriented user-interface each and enable the user to monitor and edit process data in the PLC. The displays are arranged in 2 rows for 16 characters each. Functions can be invoked and values can be edited via keys. The application will be stored in the integrated EEPROM. Special features: 앬 Word device monitoring 앬 Comments or message can be attached to up to 8 devices 앬 Current and set values can be altered for the displayed device 앬 Display of actual values and editing of setting values of timers and counters, of data registers and file registers 앬 Display of the current operation of the sequential program instructions 앬 Password protection 앬 Current time of the real-time clock can be displayed and set 앬 Display of text, programmable via the keyboard or the FX-PCS/DU-WIN-E software (only for FX-10DU-E)

FX-10 DU-E MELSEC FX 5 ± 5 % (via PLC)

Power consumption

mA 220

220

Compensation time after voltage loss

ms