Test summary

51 downloads 360 Views 136KB Size Report
Apr 30, 2013 ... Railway applications - IEC 61373: 2010-05. Durchgeführte Prüfungen I Tests conducted: Refer to Test summary. Prüfergebnis / Iesf resu/fs;.
Prüf-Nr./Q-Nr.:

SIEMENS

Ceñificate No.: Dienststelle:

Depaftment:

2525a I ¡A CE CP R&D-VI4 / Pester

Ort PIace:

Amberg

Anlagen: Enclosures.

Test

rag: Date:

Summary

12.04.2013

2525a

Pri,ïfuescheinigung I Test - Cert-fræte tProduct:

Erzeusnis

COntaCtOrS SIRIUS SiZe 56

Iyp, Type:3RT10S / 3RT145 Art der Prüfung I Type of test:

Prüfer/ Tested by:

Hersteller: SiemenS AG

rech...Daten: Referto Catalogue

Manufacturer:

Specification:

I lA CE

Vibration- and Shock test Earthquake (KWU) / Railway applications Labor/ LOVAG registered and DAkkS accredited Laboratory: Testing Laboratory Siemens AG, Amberg

R&D-VI4

Angewandte Prüfbestimmungen / Iesf specifications applied:

Earthquake - KWU ASV ZEN000 DD/7080.9/1: Entwurf 1987-07 Railway applications - IEC 61373: 2010-05 I Tests Refer to Test summary

Durchgeführte Prüfungen

Prüfergebnis

conducted:

/ Iesf resu/fs;

All requirements of the test specification are met.

Bemerkungen

I

Remarks:

lSSUed: 21.02.2011

This Test-Certificate covers contactors type 3RT1.5 (SlR|US 56), for all different operating mechanisms, inclusive the electronic coil control unit type 3RT19, with or without top / side mounted auxiliary switch blocks type 3RH19, with or without surge suppressolls type 3RTl9. lndex a, dated 12.04.2013= Standard update in accordance with IEC 61373: 2010-05

Unterschrift I Signature

-)

E-

vr"

Gegengezeichnet

I

Released by:

ì

l. L( IIACE

t, VI

Schweiger

k

I lA CE CP

Mr. Knauer

ustry Sector

SIEMENS AG S. Russwurm (Head) Siemens Aktiengesellschaft: Chairman of the Superv¡sory Board: Gerhard Cromme; Manag¡ng Board: Peter Loescher, Chairman, President and Ch¡ef Executive Off¡cer; Roland Busch, Brigitte Ederer, Klaus Helmrich, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, PeterY Solmssen, Michael Suess Registered off¡ces: Berl¡n and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg -No. DE 23691 322

Formular: Jen 2012

Test summary

Certificate No.: 2525a

Manufacturer:

Siemens AG, I IA CE CP 93413 Cham, Werner-von-Siemens-Str. 29

Test device:

Contactor size S6

Type:

3RT105… 3RT145…

Test specification:

DIN EN 61373 (2011-04) IEC 61373 (2010-05) KWU ASV ZEN000 DD/7080.9/1 (1987-07)

Test report No.:

00075TQV; 13023ENV

Test report no.: 00075TQV Tested devices: 3RT1054-1AF3 3RT1054-1NP3 3RT1054-1PP3

air-break contactor with conventional coil unit air-break contactor with electronic coil unit air-break contactor with electronic coil unit, SPS terminal and remaining lifetime indication

Other characteristic marks: - equipped according to instruction manual with sided and front-sided auxiliary switch 3RH1921.... - connection with box terminal 3RT1956-4G - screw mounted on assembly plate - tested single mounted

Required test values:

Resonance search

Test values:

floating sine excitation level frequency changing speed

4...35 Hz 2.5 m/s² 1 oct/min

floating sine

4 ... 35 Hz device switched on 35 ... 4 Hz device switched off 4 ... 35 Hz with switching operations

excitation level

continuous changing of the excitation in accordance with ZEN000 DD/7080.9/1 appendix B, Tab 1b raising factor: 1

frequency changing speed

1 oct/min

Load:

Page 1 / 9 Siemens_TYF01_Ind00

Test summary

Certificate No.: 2525a

Additional load (ao): permanent sine

2s device on, 2s device off

driving frequency

X and Z-axis 12.2 Hz each, Y-axis see following table

excitation level

X and Z-axis 84 m/s² each , Y-axis see table test result

Test results: Resonance frequencies in range up to 35 Hz: kind of mounting

output state

screwed on mounting plate

3RT1054-1NP3

3RT1054-1PP3

tested device

3RT1054-2AF3

resonance frequency Hz

raising factor

X

Y

Z

X

Y

Z

on

35

-

-

9.6

-

-

screwed on mounting plate

on

-

32

-

-

2

-

screwed on mounting plate

on

33

-

-

2

-

-

Determined excitation level with the additional load (a0): tested device

axis fe

3RT1054-1AF3 screwed on mounting plate

3RT1054-1NP3 screwed on mounting plate

3RT1054-1PP3 screwed on mounting plate

a0 -device device on device off a (m/s²) f e 0 (Hz) a (m/s²) 0 (Hz)

X Y Z

12.2 5.45 12.2

84 22* 84

12.2 5.45 12.2

84 22* 84

X Y Z

12.2 5.45 12.2

84 22* 84

12.2 5.45 12.2

84 22* 84

X Y Z

12.2 5.45 12.2

84 20* 84

12.2 5.45 12.2

84 20* 84

* test facility limit, tested device still without malfunction. At loading and additional load test there was no malfunction out of the permissible tolerance. The tested device passed the repeat routine test. Page 2 / 9 Siemens_TYF01_Ind00

Test summary

Certificate No.: 2525a

Test report no.: 13023ENV Tested devices: Sample No. 13023EN

001

002

003

Device no

Tested device

Type designation

Date code

-001

contactor

3RT1056-2AB36

E01; G/130128

-002

auxiliary switch block front mounted

3RH1921-1CA10

E06; LO121127

-003

auxiliary switch block front mounted

3RH1921-1CA01

E06; LO121119

-004

auxiliary switch block front mounted

3RH1921-1CA10

E06; LO121127

-005

auxiliary switch block front mounted

3RH1921-1CA01

E06; LO121119

-007

terminal cover

3RT1956-4EA1

G/121213

-008

terminal cover

3RT1956-4EA1

G/121213

-009

contactor

3RT1056-6PP35

E01; G/130128

-010

auxiliary switch block front mounted

3RH1921-1CA10

E06; LO121127

-011

auxiliary switch block front mounted

3RH1921-1CA01

E06; LO121119

-013

terminal cover

3RT1956-4EA2

E01; G/121205

-014

terminal cover

3RT1956-4EA2

E01; G/121205

-015

contactor

3RT1056-6NB36

E01; G/130128

-016

solid-state time-delay auxiliary switch block

3RT1926-2EJ11

E01; LO121031

-017

surge suppressor

3RT1956-1CB00

MRE/ 121211

-018

terminal cover

3RT1956-4EA1

G/121213

-019

terminal cover

3RT1956-4EA1

G/121213

mounting

monitoring

all contacts screw mounted

mechanic function

all contacts screw mounted mechanic function

all contacts

screw mounted

electric function

mechanic function

Page 3 / 9 Siemens_TYF01_Ind00

Test summary

Certificate No.: 2525a

Required test values: long life test according to DIN EN 61373 part 9.1 and IEC 61373 part 9.1

category 1 , class B

test

frequency range Hz

load duration each axis

ASD – level (m/s²)²/Hz

RMS value m/s²

long life test

5 – 150Hz

5h

0,964

5,72

orientation Vertical Transverse Longitudinal

functional test according to DIN EN 61373 part 8.1 and IEC 61373 part 8.1

test

functional test

category 1 , class B

frequency range Hz

load duration each axis

ASD – level (m/s²)²/Hz

RMS value m/s²

5 – 150Hz

10 min

0,0301

1,01

orientation Vertical Transverse Longitudinal

shock test according to DIN EN 61373 part 10.5 and IEC 61373 part 10.5

test

orientation

peak acceleration m/s²

nominal duration ms

standard specific. paragraph

shock test

Vertical Transverse Longitudinal

30 30 50

30

10.5

Page 4 / 9 Siemens_TYF01_Ind00

Test summary

Certificate No.: 2525a

Test results: Tests shock

Long life test

Functional test

according to: DIN EN 61373 part 9.1

according to: DIN EN 61373 part 8.1

according to: DIN EN 61373 part 10.5 1)

001

passed

passed

50m/s²

002

passed

passed

50m/s²

003

passed

passed

50m/s²

Sample No. 13023EN

1) shock passed by this test sample, shock duration: 30ms

The tests according to KWU ASV ZEN000 DD/7080.9/1 (1987-07) were carried out on devices, representative for the whole series, fixed on page 6 up to 7. The tests according to DIN EN 61373 (2011-04) and IEC 61373 (2010-05) were carried out on devices, representative for the whole series, fixed on page 6 up to 8. The tests were carried out in the accredited laboratory: Type Test Center Siemens AG Amberg Werner-von-Siemens-Str. 48, 92220 Amberg Accredited-No.: D-PL-11055-04-01

Page 5 / 9 Siemens_TYF01_Ind00

Nomenclature breakdown 3RT10

54

I

II

Certificate No.: 2525a

-

1

A

B3

6

III

IV

V

VI

I

Basic type designation 3RT10, motor contactor

II

Power rating: 54 55 56

III

Type of terminals: 1 2 3 6

IV

main contacts: box terminal, control terminals: screw type main contacts: screw terminal, control terminals: spring type main contacts: box terminal, control terminals: spring type main contacts: screw terminal, control terminals: screw type

-

ac/dc operating system with EMC protective unit - varistor without operating system ac/dc electronic operating system with PLC input ac/dc electronic operating system with RLT

Rated operating voltage: A.. N.. P.. Q..

VI

-

Operating system: A L N P

IV+V

- 55 kW - 75 kW - 90 kW

-

23 up to 600V, conventional operating system 21 up to 277V, electronic operating system 96 up to 277V, electronic operating system 96 up to 277V, electronic operating system

Auxiliary contact arrangement: 0 4 5 6

-

no auxiliary contact 2 NO + 2 NC top mounted 1 NO + 1 NC left side mounted 2 NO + 2 NC side mounted

Page 6 / 9 Siemens_TYF01_Ind00

Nomenclature breakdown

Certificate No.: 2525a

Continuation nomenclature breakdown:

3RT1456

-

I

1

A

B3

6

II

III

IV

V

I

Basic type designation 3RT1456, contactor with 3 main contacts for resistive load

II

Type of terminals: 1 2 3 6

III

-

ac/dc operating system with EMC protective unit - varistor without operating system ac/dc electronic operating system with PLC input ac/dc electronic operating system with RLT

Rated operating voltage: A.. N.. P.. Q..

V

main contacts: box terminal, control terminals: screw type main contacts: screw terminal, control terminals: spring type main contacts: box terminal, control terminals: spring type main contacts: screw terminal, control terminals: screw type

Operating system: A L N P

III+IV

-

-

23 up to 600V, conventional operating system 21 up to 277V, electronic operating system 96 up to 277V, electronic operating system 96 up to 277V, electronic operating system

Auxiliary contact arrangement: 0 4 5 6

3RT1955-4G 3RT1956-4G 3RT1956-4EA2 3RT1956-4EA1 3RT1956-4EA4

-

no auxiliary contact 2 NO + 2 NC top mounted 1 NO + 1 NC left side mounted 2 NO + 2 NC side mounted

Box terminal block for round and ribbon cables size up to 70 mm² Box terminal block for round and ribbon cables size up to to 120 mm² Terminal cover for box terminals Terminal cover for cable lugs and busbar connection Length: 120mm Terminal cover for cable lugs and busbar connection Length: 38mm

Page 7 / 9 Siemens_TYF01_Ind00

Nomenclature breakdown

Certificate No.: 2525a

Continuation nomenclature breakdown:

3RT19 I

26 II

-

2E III

J IV

1 V

1 VI

I.

Basic Type 3RT19 – Accessory for 3RT1 or 3RH1

II.

Size 26 - Suitable for use with devices Type 3RT Size S6

III.

Type of Function -2E - Auxiliary Contact On-Delay -2F - Auxiliary Contact Off-Delay without control voltage

IV.

Voltage Ratings C - 100 through 127 V ac D - 200 through 240 V ac J - 24 V ac/dc K - 100 through 127 V ac/dc L - 200 through 240 V ac/dc

V.

Time Range 1 - 0.05 to 1 s 2 - 0.5 to 10 s 3 - 5 to 100 s

VI.

Terminal 1 - Screw terminal

Page 8 / 9 Siemens_TYF01_Ind00

SIEMENS

AA L

\./A

DAKKS Deutsche Akkreditieru ngsstelle

G

D-PL-11055-04-01

Certificate No.: 2525a

Remarks

00075TQV:

Type test of contactor 3RT105... and 3RT145... according to KWU ASV ZEN000 DD/7080.9/1 (1987-07) and DIN EN 50155 (1996-05) The test results are in accordance with the test specification.

13023ENV:

Update type test of contactor 3RT105... and 3RT145... according to DIN EN 50155 (1996-05) to DIN EN 61373 (2011-04) and IEC 61373 (2010-05). The test results are in accordance with the test specification.

,

du,t

o.o,.

.

ffiils-æ - û^ bv)

Mrs. Herger

bv)

Manager Bogner